{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,26]],"date-time":"2025-12-26T02:18:22Z","timestamp":1766715502837,"version":"3.45.0"},"reference-count":19,"publisher":"Elsevier BV","issue":"5","license":[{"start":{"date-parts":[[2023,9,1]],"date-time":"2023-09-01T00:00:00Z","timestamp":1693526400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2023,9,1]],"date-time":"2023-09-01T00:00:00Z","timestamp":1693526400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2023,5,6]],"date-time":"2023-05-06T00:00:00Z","timestamp":1683331200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["jhsgo.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Hand Surgery Global Online"],"published-print":{"date-parts":[[2023,9]]},"DOI":"10.1016\/j.jhsg.2023.04.013","type":"journal-article","created":{"date-parts":[[2023,5,30]],"date-time":"2023-05-30T00:31:41Z","timestamp":1685406701000},"page":"650-654","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":2,"title":["A Cadaveric Study Examining the Accuracy of Wireless Hand-Held Guided Ultrasound Injections Versus Blind Injections in the Flexor Tendon Sheath"],"prefix":"10.1016","volume":"5","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-6371-4041","authenticated-orcid":false,"given":"Ceyran","family":"Hamoudi","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Antoine","family":"Martins","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Pierre-Antoine","family":"Debordes","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Thibaut","family":"Goetsch","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Philippe","family":"Liverneaux","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sybille","family":"Facca","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"issue":"15","key":"10.1016\/j.jhsg.2023.04.013_bib1","doi-asserted-by":"crossref","first-page":"e642","DOI":"10.5435\/JAAOS-D-19-00614","article-title":"Current concepts in the management of trigger finger in adults","volume":"28","author":"Gil","year":"2020","journal-title":"J\u00a0Am Acad Orthop Surg"},{"issue":"9","key":"10.1016\/j.jhsg.2023.04.013_bib2","doi-asserted-by":"crossref","first-page":"e21","DOI":"10.2106\/JBJS.RVW.21.00006","article-title":"Current concepts in the management of advanced trigger finger: a critical analysis review","volume":"9","author":"Pompeu","year":"2021","journal-title":"JBJS Rev"},{"issue":"10","key":"10.1016\/j.jhsg.2023.04.013_bib3","doi-asserted-by":"crossref","first-page":"1333","DOI":"10.7863\/jum.2005.24.10.1333","article-title":"High-frequency ultrasonographic examination of the finger pulley system","volume":"24","author":"Boutry","year":"2005","journal-title":"J\u00a0Ultrasound Med"},{"issue":"2","key":"10.1016\/j.jhsg.2023.04.013_bib4","doi-asserted-by":"crossref","first-page":"204","DOI":"10.1177\/1753193415615076","article-title":"The thickness of the A2 pulley and the flexor tendon are related to the severity of trigger finger: results of a prospective study using high-resolution ultrasonography","volume":"41","author":"Kim","year":"2016","journal-title":"J\u00a0Hand Surg Eur Vol"},{"issue":"9","key":"10.1016\/j.jhsg.2023.04.013_bib5","doi-asserted-by":"crossref","first-page":"936","DOI":"10.1177\/1753193418756808","article-title":"A\u00a0randomized controlled trial comparing ketorolac and triamcinolone injections in adults with trigger digits","volume":"43","author":"Leow","year":"2018","journal-title":"J\u00a0Hand Surg Eur Vol"},{"issue":"2","key":"10.1016\/j.jhsg.2023.04.013_bib6","doi-asserted-by":"crossref","DOI":"10.1177\/2325967119901017","article-title":"Hand-held portable versus conventional cart-based ultrasound in musculoskeletal imaging","volume":"8","author":"Falkowski","year":"2020","journal-title":"Orthop J Sports Med"},{"issue":"1","key":"10.1016\/j.jhsg.2023.04.013_bib7","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1186\/s13089-022-00274-6","article-title":"Comparison of four handheld point-of-care ultrasound devices by expert users","volume":"14","author":"Le","year":"2022","journal-title":"Ultrasound J"},{"issue":"6","key":"10.1016\/j.jhsg.2023.04.013_bib8","doi-asserted-by":"crossref","first-page":"742","DOI":"10.1017\/cem.2020.449","article-title":"The future is in your hands\u2014handheld ultrasound in the emergency department","volume":"22","author":"Thavanathan","year":"2020","journal-title":"CJEM"},{"issue":"4","key":"10.1016\/j.jhsg.2023.04.013_bib9","doi-asserted-by":"crossref","first-page":"325","DOI":"10.1159\/000505698","article-title":"Is bigger really better? Comparison of ultraportable handheld ultrasound with standard point-of-care ultrasound for evaluating safe site identification and image quality prior to pleurocentesis","volume":"99","author":"Newhouse","year":"2020","journal-title":"Respiration"},{"issue":"7","key":"10.1016\/j.jhsg.2023.04.013_bib10","doi-asserted-by":"crossref","first-page":"1139","DOI":"10.3390\/diagnostics11071139","article-title":"Performance of a handheld ultrasound device to assess articular and periarticular pathologies in patients with inflammatory arthritis","volume":"11","author":"Corte","year":"2021","journal-title":"Diagnostics"},{"issue":"5","key":"10.1016\/j.jhsg.2023.04.013_bib11","doi-asserted-by":"crossref","first-page":"524","DOI":"10.5005\/jp-journals-10071-23803","article-title":"Use of handheld ultrasound device with artificial intelligence for evaluation of cardiorespiratory system in COVID-19","volume":"25","author":"Maheshwarappa","year":"2021","journal-title":"Indian J Crit Care Med"},{"issue":"2","key":"10.1016\/j.jhsg.2023.04.013_bib12","doi-asserted-by":"crossref","first-page":"185","DOI":"10.1016\/j.ejim.2011.10.009","article-title":"Routinely adding ultrasound examinations by pocket-sized ultrasound devices improves inpatient diagnostics in a medical department","volume":"23","author":"Mjolstad","year":"2012","journal-title":"Eur J Intern Med"},{"key":"10.1016\/j.jhsg.2023.04.013_bib13","doi-asserted-by":"crossref","first-page":"87","DOI":"10.1016\/j.tmaid.2018.01.001","article-title":"Pocket-size point-of-care ultrasound in rural Uganda\u2014a unique opportunity \u201cto see\u201d, where no imaging facilities are available","volume":"23","author":"Epstein","year":"2018","journal-title":"Travel Med Infect Dis"},{"issue":"1","key":"10.1016\/j.jhsg.2023.04.013_bib14","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/s12880-020-00518-8","article-title":"Evaluating sensitivity and specificity of handheld point-of-care ultrasound testing for gynecologic pathology: a pilot study for use in low resource settings","volume":"20","author":"Toscano","year":"2020","journal-title":"BMC Med Imaging"},{"issue":"2","key":"10.1016\/j.jhsg.2023.04.013_bib15","doi-asserted-by":"crossref","first-page":"197","DOI":"10.7863\/jum.2011.30.2.197","article-title":"Sonographically guided tendon sheath injections are more accurate than blind injections: implications for trigger finger treatment","volume":"30","author":"Lee","year":"2011","journal-title":"J\u00a0Ultrasound Med"},{"author":"Urbaniak","key":"10.1016\/j.jhsg.2023.04.013_bib16"},{"issue":"12","key":"10.1016\/j.jhsg.2023.04.013_bib18","doi-asserted-by":"crossref","first-page":"2498","DOI":"10.1016\/j.jhsa.2014.09.027","article-title":"Ultrasound guidance of steroid injections","volume":"39","author":"Clain","year":"2014","journal-title":"J\u00a0Hand Surg Am Vol"},{"issue":"9","key":"10.1016\/j.jhsg.2023.04.013_bib19","doi-asserted-by":"crossref","first-page":"674","DOI":"10.1016\/j.diii.2012.06.010","article-title":"Ultrasound-guided injection in osteoarticular pathologies: general principles and precautions","volume":"93","author":"Guerini","year":"2012","journal-title":"Diagn Interv Imaging"},{"issue":"4","key":"10.1016\/j.jhsg.2023.04.013_bib20","doi-asserted-by":"crossref","first-page":"385","DOI":"10.1007\/s11552-009-9188-5","article-title":"The value of ultrasonography in hand surgery","volume":"4","author":"Furrer","year":"2009","journal-title":"Hand"}],"container-title":["Journal of Hand Surgery Global Online"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2589514123000774?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2589514123000774?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,11,11]],"date-time":"2025-11-11T18:59:02Z","timestamp":1762887542000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2589514123000774"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,9]]},"references-count":19,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2023,9]]}},"alternative-id":["S2589514123000774"],"URL":"https:\/\/doi.org\/10.1016\/j.jhsg.2023.04.013","relation":{},"ISSN":["2589-5141"],"issn-type":[{"type":"print","value":"2589-5141"}],"subject":[],"published":{"date-parts":[[2023,9]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"A Cadaveric Study Examining the Accuracy of Wireless Hand-Held Guided Ultrasound Injections Versus Blind Injections in the Flexor Tendon Sheath","name":"articletitle","label":"Article Title"},{"value":"Journal of Hand Surgery Global Online","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jhsg.2023.04.013","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2023 THE AUTHORS. Published by Elsevier Inc. on behalf of The American Society for Surgery of the Hand.","name":"copyright","label":"Copyright"}]}}