{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,6]],"date-time":"2026-11-06T15:49:47Z","timestamp":1793980187966,"version":"4.8.0"},"reference-count":27,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2025,2,1]],"date-time":"2025-02-01T00:00:00Z","timestamp":1738368000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2025,2,1]],"date-time":"2025-02-01T00:00:00Z","timestamp":1738368000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2024,9,3]],"date-time":"2024-09-03T00:00:00Z","timestamp":1725321600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["jisakos.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of ISAKOS"],"published-print":{"date-parts":[[2025,2]]},"DOI":"10.1016\/j.jisako.2024.100317","type":"journal-article","created":{"date-parts":[[2024,9,7]],"date-time":"2024-09-07T21:53:30Z","timestamp":1725746010000},"page":"100317","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":17,"special_numbering":"C","title":["Is bicortical femoral pin insertion safe for image-based robotic knee arthroplasty surgery ? A comparative complications analysis in 970 consecutive cases"],"prefix":"10.1016","volume":"10","author":[{"given":"Christos","family":"Koutserimpas","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0008-1487-5066","authenticated-orcid":false,"given":"Cl\u00e9ment","family":"Favroul","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"C\u00e9cile","family":"Batailler","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Elvire","family":"Servien","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"S\u00e9bastien","family":"Lustig","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.jisako.2024.100317_bib1","doi-asserted-by":"crossref","first-page":"3369","DOI":"10.1007\/s00402-022-04632-w","article-title":"The evolution of robotic systems for total knee arthroplasty, each system must be assessed for its own value: a systematic review of clinical evidence and meta-analysis","volume":"143","author":"Vermue","year":"2023","journal-title":"Arch Orthop Trauma Surg"},{"key":"10.1016\/j.jisako.2024.100317_bib2","doi-asserted-by":"crossref","first-page":"2677","DOI":"10.1007\/s00167-021-06464-4","article-title":"Robotic-arm assisted total knee arthroplasty is associated with improved accuracy and patient reported outcomes: a systematic review and meta-analysis","volume":"30","author":"Zhang","year":"2022","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"10.1016\/j.jisako.2024.100317_bib3","doi-asserted-by":"crossref","first-page":"3585","DOI":"10.1007\/s00167-020-06283-z","article-title":"MAKO CT-based robotic arm-assisted system is a reliable procedure for total knee arthroplasty: a systematic review","volume":"29","author":"Batailler","year":"2021","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"10.1016\/j.jisako.2024.100317_bib4","doi-asserted-by":"crossref","first-page":"961","DOI":"10.1302\/0301-620X.105B9.BJJ-2023-0006.R3","article-title":"Robotic Arm-assisted versus Manual (ROAM) total knee arthroplasty: a randomized controlled trial","volume":"105-B","author":"Clement","year":"2023","journal-title":"Bone Joint Lett J"},{"key":"10.1016\/j.jisako.2024.100317_bib5","doi-asserted-by":"crossref","first-page":"930","DOI":"10.1302\/0301-620X.100B7.BJJ-2017-1449.R1","article-title":"Robotic-arm assisted total knee arthroplasty is associated with improved early functional recovery and reduced time to hospital discharge compared with conventional jig-based total knee arthroplasty: a prospective cohort study","volume":"100-B","author":"Kayani","year":"2018","journal-title":"Bone Joint Lett J"},{"key":"10.1016\/j.jisako.2024.100317_bib6","doi-asserted-by":"crossref","first-page":"252","DOI":"10.1302\/2058-5241.6.200071","article-title":"A\u00a0clinical review of robotic navigation in total knee arthroplasty: historical systems to modern design","volume":"6","author":"Siddiqi","year":"2021","journal-title":"EFORT Open Rev"},{"key":"10.1016\/j.jisako.2024.100317_bib7","doi-asserted-by":"crossref","first-page":"1088","DOI":"10.1302\/0301-620X.103B6.BJJ-2020-1355.R2","article-title":"Robotic arm-assisted versus conventional medial unicompartmental knee arthroplasty: five-year clinical outcomes of a randomized controlled trial","volume":"103-B","author":"Banger","year":"2021","journal-title":"Bone Joint Lett J"},{"key":"10.1016\/j.jisako.2024.100317_bib8","doi-asserted-by":"crossref","first-page":"926","DOI":"10.1016\/j.arth.2019.01.018","article-title":"Revision analysis of robotic arm-assisted and manual unicompartmental knee arthroplasty","volume":"34","author":"Cool","year":"2019","journal-title":"J\u00a0Arthroplasty"},{"key":"10.1016\/j.jisako.2024.100317_bib9","doi-asserted-by":"crossref","first-page":"541","DOI":"10.1302\/0301-620X.104B5.BJJ-2021-1506.R1","article-title":"Robotic arm-assisted versus manual unicompartmental knee arthroplasty : a systematic review and meta-analysis of the MAKO robotic system","volume":"104-B","author":"Zhang","year":"2022","journal-title":"Bone Joint Lett J"},{"key":"10.1016\/j.jisako.2024.100317_bib10","doi-asserted-by":"crossref","first-page":"736","DOI":"10.1007\/s00167-022-07031-1","article-title":"Complications and downsides of the robotic total knee arthroplasty: a systematic review","volume":"31","author":"Nogalo","year":"2023","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"10.1016\/j.jisako.2024.100317_bib11","doi-asserted-by":"crossref","first-page":"2043","DOI":"10.1007\/s00402-021-04208-0","article-title":"The MAKO robotic-arm knee arthroplasty system","volume":"141","author":"Roche","year":"2021","journal-title":"Arch Orthop Trauma Surg"},{"key":"10.1016\/j.jisako.2024.100317_bib12","unstructured":"MAKO TKA e Stryker surgical guide. https:\/\/www.strykermeded.com\/media\/2223\/mako-tka-surgical-guide.pdf. [Accessed 31 March 2024]."},{"key":"10.1016\/j.jisako.2024.100317_bib13","doi-asserted-by":"crossref","first-page":"262","DOI":"10.3390\/medicina60020262","article-title":"Pitfalls with the MAKO robotic-arm-assisted total knee arthroplasty","volume":"60","author":"Dretakis","year":"2024","journal-title":"Medicina"},{"key":"10.1016\/j.jisako.2024.100317_bib14","doi-asserted-by":"crossref","first-page":"2604","DOI":"10.1016\/j.arth.2017.02.005","article-title":"Arthrofibrosis associated with total knee arthroplasty","volume":"32","author":"Cheuy","year":"2017","journal-title":"J\u00a0Arthroplasty"},{"key":"10.1016\/j.jisako.2024.100317_bib15","doi-asserted-by":"crossref","DOI":"10.2106\/JBJS.RVW.22.00128","article-title":"Local soft-tissue thickness vs. Body mass index as predictors of complications after total knee or hip arthroplasty: a literature review","volume":"11","author":"Parikh","year":"2023","journal-title":"JBJS Rev"},{"key":"10.1016\/j.jisako.2024.100317_bib16","article-title":"Saw-box osteotomy versus reamer-box osteotomy in posterior stabilized total knee arthroplasty: a retrospective study of an average five year follow-up","volume":"22","author":"Abdelbadie","year":"2024","journal-title":"Int Orthop"},{"key":"10.1016\/j.jisako.2024.100317_bib17","article-title":"The cost-effectiveness of robotic-assisted versus manual total knee arthroplasty: a markov model-based evaluation","volume":"30","author":"Rajan","year":"2022","journal-title":"J\u00a0Am Acad Orthop Surg"},{"key":"10.1016\/j.jisako.2024.100317_bib18","doi-asserted-by":"crossref","first-page":"180","DOI":"10.1016\/j.artd.2020.03.014","article-title":"Increased intercondylar femoral box cut-to-femur size ratio during posterior-stabilized total knee arthroplasty increases risk for intraoperative fracture","volume":"6","author":"Sherman","year":"2020","journal-title":"Arthroplast Today"},{"key":"10.1016\/j.jisako.2024.100317_bib19","doi-asserted-by":"crossref","first-page":"25","DOI":"10.1186\/s42836-021-00082-8","article-title":"Do bicortical diaphyseal array pins create the risk of periprosthetic fracture in robotic-assisted knee arthroplasties?","volume":"3","author":"Yun","year":"2021","journal-title":"Arthroplasty"},{"key":"10.1016\/j.jisako.2024.100317_bib20","doi-asserted-by":"crossref","first-page":"e20","DOI":"10.2106\/JBJS.RVW.20.00091","article-title":"Periprosthetic fractures through tracking pin sites following computer navigated\u00a0and robotic total and unicompartmental knee arthroplasty: a systematic review","volume":"9","author":"Smith","year":"2021","journal-title":"JBJS Rev"},{"key":"10.1016\/j.jisako.2024.100317_bib21","doi-asserted-by":"crossref","first-page":"2291","DOI":"10.1016\/j.arth.2022.05.012","article-title":"Pin-related complications in computer navigated and robotic-assisted knee arthroplasty: a systematic review","volume":"37","author":"Thomas","year":"2022","journal-title":"J\u00a0Arthroplasty"},{"key":"10.1016\/j.jisako.2024.100317_bib22","first-page":"1102","article-title":"Distal femoral tracker pin placement prevents delayed pin tract-induced fracture in robotic-assisted total knee arthroplasty: results of minimum 1-year follow-up","volume":"36","author":"Baek","year":"2023","journal-title":"J\u00a0Knee Surg"},{"key":"10.1016\/j.jisako.2024.100317_bib23","article-title":"Individualized functional knee alignment in total knee arthroplasty: a robotic-assisted technique","volume":"7","author":"Clark","year":"2021","journal-title":"Tech Orthop"},{"key":"10.1016\/j.jisako.2024.100317_bib24","doi-asserted-by":"crossref","first-page":"745","DOI":"10.1016\/j.knee.2019.02.005","article-title":"Low rate of iatrogenic complications during unicompartmental knee arthroplasty with two semiautonomous robotic systems","volume":"26","author":"Lonner","year":"2019","journal-title":"Knee"},{"key":"10.1016\/j.jisako.2024.100317_bib25","doi-asserted-by":"crossref","first-page":"195","DOI":"10.1016\/j.knee.2021.11.016","article-title":"Clinical and radiological outcomes of robotic-assisted unicompartmental knee arthroplasty: early lessons from the first 100 consecutive knees in 85 patients","volume":"34","author":"St","year":"2022","journal-title":"Knee"},{"key":"10.1016\/j.jisako.2024.100317_bib26","doi-asserted-by":"crossref","first-page":"910","DOI":"10.1016\/j.arth.2023.10.050","article-title":"Intraincisional pin placement is safe for robotic-assisted total knee arthroplasty","volume":"39","author":"Stetzer","year":"2024","journal-title":"J\u00a0Arthroplasty"},{"key":"10.1016\/j.jisako.2024.100317_bib27","doi-asserted-by":"crossref","first-page":"593","DOI":"10.1007\/s00167-020-06341-6","article-title":"Robot-assisted total knee arthroplasty is associated with a learning curve for surgical time but not for component alignment, limb alignment and gap balancing","volume":"30","author":"Vermue","year":"2022","journal-title":"Knee Surg Sports Traumatol Arthrosc"}],"container-title":["Journal of ISAKOS"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2059775424001640?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2059775424001640?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,2,17]],"date-time":"2025-02-17T17:28:10Z","timestamp":1739813290000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2059775424001640"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,2]]},"references-count":27,"alternative-id":["S2059775424001640"],"URL":"https:\/\/doi.org\/10.1016\/j.jisako.2024.100317","relation":{},"ISSN":["2059-7754"],"issn-type":[{"value":"2059-7754","type":"print"}],"subject":[],"published":{"date-parts":[[2025,2]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Is bicortical femoral pin insertion safe for image-based robotic knee arthroplasty surgery ? A comparative complications analysis in 970 consecutive cases","name":"articletitle","label":"Article Title"},{"value":"Journal of ISAKOS","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jisako.2024.100317","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2024 The Author(s). Published by Elsevier Inc. on behalf of International Society of Arthroscopy, Knee Surgery and Orthopedic Sports Medicine.","name":"copyright","label":"Copyright"}],"article-number":"100317"}}