{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,7,4]],"date-time":"2025-07-04T04:08:00Z","timestamp":1751602080946,"version":"3.41.0"},"reference-count":8,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2025,6,1]],"date-time":"2025-06-01T00:00:00Z","timestamp":1748736000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2025,6,1]],"date-time":"2025-06-01T00:00:00Z","timestamp":1748736000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2025,4,30]],"date-time":"2025-04-30T00:00:00Z","timestamp":1745971200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100007128","name":"Shaanxi Province Natural Science Foundation","doi-asserted-by":"publisher","award":["2024 JC-YBMS-630"],"award-info":[{"award-number":["2024 JC-YBMS-630"]}],"id":[{"id":"10.13039\/501100007128","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["jisakos.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of ISAKOS"],"published-print":{"date-parts":[[2025,6]]},"DOI":"10.1016\/j.jisako.2025.100893","type":"journal-article","created":{"date-parts":[[2025,5,5]],"date-time":"2025-05-05T23:44:52Z","timestamp":1746488692000},"page":"100893","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"special_numbering":"C","title":["Pretibial abscess associated with instrumentation-specific infection after anterior cruciate ligament reconstruction: A case report"],"prefix":"10.1016","volume":"12","author":[{"given":"Xian","family":"Zhang","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Cong","family":"Qiao","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jiang","family":"Zheng","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9068-3735","authenticated-orcid":false,"given":"Bo","family":"Ren","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"issue":"8","key":"10.1016\/j.jisako.2025.100893_bib1","doi-asserted-by":"crossref","first-page":"911.e1","DOI":"10.1016\/j.arthro.2006.07.025","article-title":"Sterile pretibial abscess after anterior cruciate reconstruction from bioabsorbable interference screws: a report of 2 cases","volume":"23","author":"Busfield","year":"2007","journal-title":"Arthroscopy"},{"issue":"9","key":"10.1016\/j.jisako.2025.100893_bib2","doi-asserted-by":"crossref","first-page":"E133","DOI":"10.1016\/j.arthro.2003.09.017","article-title":"Transcutaneous migration of a tibial bioabsorbable interference screw after anterior cruciate ligament reconstruction","volume":"19","author":"Sassmannshausen","year":"2003","journal-title":"Arthroscopy"},{"issue":"12","key":"10.1016\/j.jisako.2025.100893_bib3","doi-asserted-by":"crossref","first-page":"1710","DOI":"10.1016\/j.arthro.2010.04.074","article-title":"Extrusion of tibial tunnel bioabsorbable screw 15 months after anterior cruciate ligament reconstruction","volume":"26","author":"Anakwenze","year":"2010","journal-title":"Arthroscopy"},{"issue":"4","key":"10.1016\/j.jisako.2025.100893_bib4","doi-asserted-by":"crossref","first-page":"806","DOI":"10.1177\/0363546520902716","article-title":"Screw and sheath tibial fixation associated with a higher likelihood of deep infection after hamstring graft anterior cruciate ligament reconstruction","volume":"48","author":"Hurvitz","year":"2020","journal-title":"Am J Sports Med"},{"issue":"11","key":"10.1016\/j.jisako.2025.100893_bib5","doi-asserted-by":"crossref","first-page":"1375","DOI":"10.1007\/s00256-012-1486-2","article-title":"Tibial tunnel and pretibial cysts following ACL graft reconstruction: MR imaging diagnosis","volume":"41","author":"Ghazikhanian","year":"2012","journal-title":"Skelet Radiol"},{"issue":"12","key":"10.1016\/j.jisako.2025.100893_bib6","doi-asserted-by":"crossref","first-page":"1179","DOI":"10.1086\/662712","article-title":"Outbreak of Pseudomonas aeruginosa surgical site infections after arthroscopic procedures: Texas, 2009","volume":"32","author":"Tosh","year":"2011","journal-title":"Infect Control Hosp Epidemiol"},{"issue":"2","key":"10.1016\/j.jisako.2025.100893_bib7","doi-asserted-by":"crossref","first-page":"173","DOI":"10.1016\/S0749-8063(00)90032-X","article-title":"An unusual epidemic of Staphylococcus-negative infections involving anterior cruciate ligament reconstruction with salvage of the graft and function","volume":"16","author":"Viola","year":"2000","journal-title":"Arthroscopy"},{"issue":"6","key":"10.1016\/j.jisako.2025.100893_bib8","doi-asserted-by":"crossref","first-page":"481","DOI":"10.1177\/1941738109347975","article-title":"Instrumentation-specific infection after anterior cruciate ligament reconstruction","volume":"1","author":"Parada","year":"2009","journal-title":"Sport Health"}],"container-title":["Journal of ISAKOS"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2059775425005103?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2059775425005103?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,7,3]],"date-time":"2025-07-03T14:39:31Z","timestamp":1751553571000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2059775425005103"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,6]]},"references-count":8,"alternative-id":["S2059775425005103"],"URL":"https:\/\/doi.org\/10.1016\/j.jisako.2025.100893","relation":{},"ISSN":["2059-7754"],"issn-type":[{"type":"print","value":"2059-7754"}],"subject":[],"published":{"date-parts":[[2025,6]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Pretibial abscess associated with instrumentation-specific infection after anterior cruciate ligament reconstruction: A case report","name":"articletitle","label":"Article Title"},{"value":"Journal of ISAKOS","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jisako.2025.100893","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2025 The Author(s). Published by Elsevier Inc. on behalf of International Society of Arthroscopy, Knee Surgery and Orthopedic Sports Medicine.","name":"copyright","label":"Copyright"}],"article-number":"100893"}}