{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,15]],"date-time":"2026-07-15T16:36:29Z","timestamp":1784133389192,"version":"3.55.0"},"reference-count":30,"publisher":"Elsevier BV","issue":"6","license":[{"start":{"date-parts":[[2016,6,1]],"date-time":"2016-06-01T00:00:00Z","timestamp":1464739200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2016,6,1]],"date-time":"2016-06-01T00:00:00Z","timestamp":1464739200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2017,6,1]],"date-time":"2017-06-01T00:00:00Z","timestamp":1496275200000},"content-version":"vor","delay-in-days":365,"URL":"http:\/\/www.elsevier.com\/open-access\/userlicense\/1.0\/"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","journal-of-cardiology.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Cardiology"],"published-print":{"date-parts":[[2016,6]]},"DOI":"10.1016\/j.jjcc.2015.12.008","type":"journal-article","created":{"date-parts":[[2016,1,27]],"date-time":"2016-01-27T11:33:31Z","timestamp":1453894411000},"page":"513-518","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":11,"title":["Implantation depth measured by 64-slice computed tomography is associated with permanent pacemaker requirement following transcatheter aortic valve implantation with the Core Valve\u00ae system"],"prefix":"10.1016","volume":"67","author":[{"given":"J\u00fcrgen","family":"Kammler","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hermann","family":"Blessberger","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Franz","family":"Fellner","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alexander","family":"Kypta","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thomas","family":"Lambert","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Magdalena","family":"Engl","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Simon","family":"H\u00f6nig","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael","family":"Lichtenauer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael","family":"Grund","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Klaus","family":"Kerschner","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Karim","family":"Saleh","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Clemens","family":"Steinwender","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.jjcc.2015.12.008_bib0155","doi-asserted-by":"crossref","first-page":"951","DOI":"10.1161\/CIRCULATIONAHA.109.927152","article-title":"Permanent pacemaker insertion after CoreValve transcatheter aortic valve implantation: incidence and contributing factors (the UK Core-Valve Collaborative)","volume":"123","author":"Khawaja","year":"2011","journal-title":"Circulation"},{"key":"10.1016\/j.jjcc.2015.12.008_bib0160","doi-asserted-by":"crossref","first-page":"310","DOI":"10.1016\/j.jcin.2008.04.007","article-title":"Early and persistent intraventricular conduction abnormalities and requirements for pacemaking after percutaneous replacement of the aortic valve","volume":"1","author":"Piazza","year":"2008","journal-title":"JACC Cardiovasc Interv"},{"key":"10.1016\/j.jjcc.2015.12.008_bib0165","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1038\/nrcardio.2011.164","article-title":"Transcatheter aortic valve implantation: current and future approaches","volume":"9","author":"Rodes-Cabau","year":"2011","journal-title":"Nat Rev Cardiol"},{"key":"10.1016\/j.jjcc.2015.12.008_bib0170","doi-asserted-by":"crossref","first-page":"1597","DOI":"10.1056\/NEJMoa1008232","article-title":"Transcatheter aortic valve implantation for aortic stenosis in patients who cannot undergo surgery","volume":"363","author":"Leon","year":"2010","journal-title":"N Engl J Med"},{"key":"10.1016\/j.jjcc.2015.12.008_bib0175","doi-asserted-by":"crossref","first-page":"2187","DOI":"10.1056\/NEJMoa1103510","article-title":"Transcatheter versus surgical aortic valve replacement in high-risk patients","volume":"364","author":"Smith","year":"2011","journal-title":"N Engl J Med"},{"key":"10.1016\/j.jjcc.2015.12.008_bib0180","doi-asserted-by":"crossref","first-page":"112","DOI":"10.1016\/j.jjcc.2014.05.001","article-title":"First direct comparison of clinical outcomes between European and Asian cohorts in transcatheter aortic valve implantation: the Massy study group vs. the PREVAIL JAPAN trial","volume":"65","author":"Watanabe","year":"2015","journal-title":"J Cardiol"},{"key":"10.1016\/j.jjcc.2015.12.008_bib0185","doi-asserted-by":"crossref","first-page":"167","DOI":"10.1161\/CIRCINTERVENTIONS.108.819839","article-title":"Progress and current status of percutaneous aortic valve replacement: results of three device generations of the CoreValve Revalving system","volume":"1","author":"Grube","year":"2008","journal-title":"Circ Cardiovasc Interv"},{"key":"10.1016\/j.jjcc.2015.12.008_bib0190","first-page":"610","article-title":"Novel therapeutic aspects of percutaneous aortic valve replacement with the 21F CoreValve Revalving System","volume":"70","author":"Berry","year":"2007","journal-title":"Catheter Cardiovasc Interv"},{"key":"10.1016\/j.jjcc.2015.12.008_bib0195","doi-asserted-by":"crossref","first-page":"475","DOI":"10.4244\/EIJ30V6I4A80","article-title":"Persistent conduction abnormalities and requirements for pacemaking six months after transcatheter aortic valve implantation","volume":"6","author":"Piazza","year":"2010","journal-title":"EuroIntervention"},{"key":"10.1016\/j.jjcc.2015.12.008_bib0200","doi-asserted-by":"crossref","first-page":"3437","DOI":"10.1093\/eurheartj\/eht408","article-title":"Clinical outcomes of patients with low-flow, low-gradient, severe aortic stenosis and either preserved or reduced ejection fraction undergoing transcatheter aortic valve implantation","volume":"34","author":"O'Sullivan","year":"2013","journal-title":"Eur Heart J"},{"key":"10.1016\/j.jjcc.2015.12.008_bib0205","doi-asserted-by":"crossref","first-page":"178","DOI":"10.1016\/j.jjcc.2013.11.005","article-title":"Who is the right patient for TAVI?","volume":"63","author":"Arai","year":"2013","journal-title":"J Cardiol"},{"key":"10.1016\/j.jjcc.2015.12.008_bib0210","doi-asserted-by":"crossref","first-page":"293","DOI":"10.1016\/j.jcct.2011.04.007","article-title":"Computed tomography evaluation for transcatheter aortic valve implantation (TAVI): imaging of the aortic root and iliac arteries","volume":"5","author":"Schoenhagen","year":"2011","journal-title":"J Cardiovasc Comput Tomogr"},{"key":"10.1016\/j.jjcc.2015.12.008_bib0215","doi-asserted-by":"crossref","first-page":"650","DOI":"10.1148\/radiol.13120696","article-title":"CT in transcatheter aortic valve replacement","volume":"269","author":"Blanke","year":"2013","journal-title":"Radiology"},{"key":"10.1016\/j.jjcc.2015.12.008_bib0220","doi-asserted-by":"crossref","first-page":"1600","DOI":"10.1016\/j.amjcard.2011.07.020","article-title":"Predictors and course of high-degree atrio-ventricular block after transcatheter aortic valve implantation using the Core Valve Revalving System","volume":"108","author":"Guetta","year":"2011","journal-title":"Am J Cardiol"},{"key":"10.1016\/j.jjcc.2015.12.008_bib0225","doi-asserted-by":"crossref","first-page":"837","DOI":"10.1016\/j.jcin.2015.02.005","article-title":"Optimal implantation depth and adherence to guidelines on permanent pacing to improve the results of transcatheter aortic valve replacement with the Medtronic CoreValve system: the CoreValve Prospective, International, Post-Market ADVANCE-II Study","volume":"8","author":"Petronio","year":"2015","journal-title":"JACC Cardiovasc Interv"},{"key":"10.1016\/j.jjcc.2015.12.008_bib0230","doi-asserted-by":"crossref","first-page":"1687","DOI":"10.1136\/heartjnl-2011-300308","article-title":"Permanent pacemaker implantation following isolated aortic valve replacement in a large cohort of elderly patients with severe aortic stenosis","volume":"97","author":"Bagur","year":"2011","journal-title":"Heart"},{"key":"10.1016\/j.jjcc.2015.12.008_bib0235","doi-asserted-by":"crossref","first-page":"475","DOI":"10.1510\/icvts.2010.254607","article-title":"In patients undergoing aortic valve replacement, what factors predict the requirement for permanent pacemaker implantation?","volume":"12","author":"Matthews","year":"2011","journal-title":"Interact Cardiovasc Thorac Surg"},{"key":"10.1016\/j.jjcc.2015.12.008_bib0240","doi-asserted-by":"crossref","first-page":"391","DOI":"10.1111\/j.1540-8167.2011.02211.x","article-title":"Risk for permanent pacemaker after transcatheter aortic valve implantation: a comprehensive analysis of the literature","volume":"23","author":"Erkapic","year":"2012","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.jjcc.2015.12.008_bib0245","doi-asserted-by":"crossref","first-page":"488","DOI":"10.1007\/s11936-013-0245-6","article-title":"Conduction disorders after transcatheter aortic valve implantation: a focused review","volume":"15","author":"McDonnell","year":"2013","journal-title":"Curr Treat Options Cardiovasc Med"},{"key":"10.1016\/j.jjcc.2015.12.008_bib0250","doi-asserted-by":"crossref","first-page":"140","DOI":"10.1093\/eurheartj\/ehq453","article-title":"Percutaneous transarterial aortic valve implantation: what do we know?","volume":"32","author":"Webb","year":"2011","journal-title":"Eur Heart J"},{"key":"10.1016\/j.jjcc.2015.12.008_bib0255","doi-asserted-by":"crossref","first-page":"1753","DOI":"10.1016\/j.jacc.2012.07.034","article-title":"Left bundle branch block after transcatheter aortic valve implantation: inconsequential or a clinically important endpoint?","volume":"60","author":"Colombo","year":"2012","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.jjcc.2015.12.008_bib0260","doi-asserted-by":"crossref","first-page":"1743","DOI":"10.1016\/j.jacc.2012.07.035","article-title":"Predictive factors and long-term clinical consequences of persistent left bundle branch block following transcatheter aortic valve implantation with a balloon-expandable valve","volume":"60","author":"Urena","year":"2012","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.jjcc.2015.12.008_bib0265","doi-asserted-by":"crossref","first-page":"285","DOI":"10.1016\/j.amjcard.2010.09.015","article-title":"Frequency of conduction abnormalities after transcatheter aortic valve implantation with the Medtronic-CoreValve and the effect on left ventricular ejection fraction","volume":"107","author":"Tzikas","year":"2011","journal-title":"Am J Cardiol"},{"key":"10.1016\/j.jjcc.2015.12.008_bib0270","doi-asserted-by":"crossref","first-page":"1300","DOI":"10.1161\/CIRCULATIONAHA.112.001099","article-title":"Clinical impact of persistent left bundle-branch block after transcatheter aortic valve implantation with CoreValve Revalving System","volume":"127","author":"Testa","year":"2013","journal-title":"Circulation"},{"key":"10.1016\/j.jjcc.2015.12.008_bib0275","doi-asserted-by":"crossref","first-page":"720","DOI":"10.1161\/CIRCULATIONAHA.112.101055","article-title":"Left bundle-branch block induced by transcatheter aortic valve implantation increases risk of death","volume":"126","author":"Houthuizen","year":"2012","journal-title":"Circulation"},{"key":"10.1016\/j.jjcc.2015.12.008_bib0280","doi-asserted-by":"crossref","first-page":"1864","DOI":"10.1016\/j.jacc.2012.08.960","article-title":"Long-term outcomes after transcatheter aortic valve implantation: insights on prognostic factors and valve durability from the Canadian multicenter experience","volume":"60","author":"Rod\u00e9s-Cabau","year":"2012","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.jjcc.2015.12.008_bib0285","doi-asserted-by":"crossref","first-page":"2067","DOI":"10.1093\/eurheartj\/ehr110","article-title":"Timing and potential mechanisms of new conduction abnormalities during the implantation of the Medtronic CoreValve System in patients with aortic stenosis","volume":"32","author":"Nuis","year":"2011","journal-title":"Eur Heart J"},{"key":"10.1016\/j.jjcc.2015.12.008_bib0290","doi-asserted-by":"crossref","first-page":"1364","DOI":"10.1111\/j.1540-8159.2010.02870.x","article-title":"Incidence and predictors of permanent pacemaker requirement after transcatheter aortic valve implantation with a self-expanding bioprosthesis","volume":"33","author":"Ferreira","year":"2010","journal-title":"PACE"},{"key":"10.1016\/j.jjcc.2015.12.008_bib0295","doi-asserted-by":"crossref","first-page":"280","DOI":"10.1161\/CIRCINTERVENTIONS.111.961649","article-title":"Atrioventricular conduction disturbance characterization in transcatheter aortic valve implantation with the Core valve prosthesis","volume":"4","author":"Rubin","year":"2011","journal-title":"Circ Cardiovasc Interv"},{"key":"10.1016\/j.jjcc.2015.12.008_bib0300","doi-asserted-by":"crossref","first-page":"1556","DOI":"10.1016\/j.amjcard.2014.08.020","article-title":"Insights into new-onset rhythm conduction disorders detected by multi-detector row computed tomography after transcatheter aortic valve implantation","volume":"114","author":"Katsanos","year":"2014","journal-title":"Am J Cardiol"}],"container-title":["Journal of Cardiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0914508716000071?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0914508716000071?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,12]],"date-time":"2025-10-12T12:55:10Z","timestamp":1760273710000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0914508716000071"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,6]]},"references-count":30,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2016,6]]}},"alternative-id":["S0914508716000071"],"URL":"https:\/\/doi.org\/10.1016\/j.jjcc.2015.12.008","relation":{},"ISSN":["0914-5087"],"issn-type":[{"value":"0914-5087","type":"print"}],"subject":[],"published":{"date-parts":[[2016,6]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Implantation depth measured by 64-slice computed tomography is associated with permanent pacemaker requirement following transcatheter aortic valve implantation with the Core Valve\u00ae system","name":"articletitle","label":"Article Title"},{"value":"Journal of Cardiology","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jjcc.2015.12.008","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2016 Japanese College of Cardiology. Published by Elsevier Ltd.","name":"copyright","label":"Copyright"}]}}