{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,7]],"date-time":"2026-01-07T23:19:43Z","timestamp":1767827983703,"version":"3.49.0"},"reference-count":15,"publisher":"Elsevier BV","issue":"1","license":[{"start":{"date-parts":[[2017,1,1]],"date-time":"2017-01-01T00:00:00Z","timestamp":1483228800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2017,1,1]],"date-time":"2017-01-01T00:00:00Z","timestamp":1483228800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2018,1,1]],"date-time":"2018-01-01T00:00:00Z","timestamp":1514764800000},"content-version":"vor","delay-in-days":365,"URL":"http:\/\/www.elsevier.com\/open-access\/userlicense\/1.0\/"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","journal-of-cardiology.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Cardiology"],"published-print":{"date-parts":[[2017,1]]},"DOI":"10.1016\/j.jjcc.2016.08.004","type":"journal-article","created":{"date-parts":[[2016,9,9]],"date-time":"2016-09-09T00:44:20Z","timestamp":1473381860000},"page":"359-363","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":9,"title":["Potential roles of the wearable cardioverter-defibrillator in acute phase care of patients at high risk of sudden cardiac death: A single-center Japanese experience"],"prefix":"10.1016","volume":"69","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-9866-2325","authenticated-orcid":false,"given":"Shingo","family":"Sasaki","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yoshihiro","family":"Shoji","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yuji","family":"Ishida","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takahiko","family":"Kinjo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yuichi","family":"Tsushima","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Maiko","family":"Seno","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Fumie","family":"Nishizaki","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Taihei","family":"Itoh","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kei","family":"Izumiyama","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takashi","family":"Yokota","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hiroaki","family":"Yokoyama","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Masahiro","family":"Yamada","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Daisuke","family":"Horiuchi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Masaomi","family":"Kimura","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takumi","family":"Higuma","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hirofumi","family":"Tomita","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ken","family":"Okumura","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.jjcc.2016.08.004_bib0080","doi-asserted-by":"crossref","first-page":"4","DOI":"10.1111\/j.1540-8159.2004.00378.x","article-title":"Use of a wearable defibrillator in terminating tachyarrhythmias in patients at high risk for sudden death: results of the WEARIT\/BIROAD","volume":"27","author":"Feldman","year":"2004","journal-title":"Pacing Clin Electrophysiol"},{"key":"10.1016\/j.jjcc.2016.08.004_bib0085","doi-asserted-by":"crossref","first-page":"194","DOI":"10.1016\/j.jacc.2010.04.016","article-title":"Aggregate national experience with the wearable cardioverter-defibrillator: event rates, compliance, and survival","volume":"56","author":"Chung","year":"2010","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.jjcc.2016.08.004_bib0090","doi-asserted-by":"crossref","first-page":"2000","DOI":"10.1016\/j.jacc.2013.05.086","article-title":"Wearable cardioverter-defibrillator use in patients perceived to be at high risk early post-myocardial infarction","volume":"62","author":"Epstein","year":"2013","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.jjcc.2016.08.004_bib0095","doi-asserted-by":"crossref","first-page":"1613","DOI":"10.1161\/CIRCULATIONAHA.115.015677","article-title":"Use of the wearable cardioverter defibrillator in high-risk cardiac patients: data from the Prospective Registry of Patients Using the Wearable Cardioverter Defibrillator (WEARIT-II Registry)","volume":"132","author":"Kutyifa","year":"2015","journal-title":"Circulation"},{"key":"10.1016\/j.jjcc.2016.08.004_bib0100","unstructured":"Niwano S, Kurita T, Katou R, Okamura H, Sekiguchi Y, Iwasaki M, Ishii Y, Matsumoto M, Nitta T, Okumura K. The second statement of clinical use of WCD. Japanese Heart Rhythm Society. http:\/\/new.jhrs.or.jp\/guideline\/com_device201401_01\/ [accessed 22.04.16]."},{"key":"10.1016\/j.jjcc.2016.08.004_bib0105","doi-asserted-by":"crossref","first-page":"2987","DOI":"10.1253\/circj.CJ-14-1098","article-title":"Usefulness of the wearable cardioverter-defibrillator in patients at high risk for sudden cardiac death","volume":"78","author":"Sasaki","year":"2014","journal-title":"Circ J"},{"key":"10.1016\/j.jjcc.2016.08.004_bib0110","doi-asserted-by":"crossref","first-page":"67","DOI":"10.1016\/j.joa.2015.08.003","article-title":"An appropriate shock of the wearable cardioverter-defibrillator in an outpatient setting","volume":"32","author":"Kishihara","year":"2016","journal-title":"J Arrhythm"},{"key":"10.1016\/j.jjcc.2016.08.004_bib0115","doi-asserted-by":"crossref","first-page":"353","DOI":"10.1111\/j.1540-8159.2009.02590.x","article-title":"Bridging a temporary high risk of sudden arrhythmic death. Experience with the wearable cardioverter defibrillator (WCD)","volume":"33","author":"Klein","year":"2010","journal-title":"Pacing Clin Electrophysiol"},{"key":"10.1016\/j.jjcc.2016.08.004_bib0120","doi-asserted-by":"crossref","first-page":"2230","DOI":"10.1093\/eurheartj\/eht167","article-title":"Risk stratification for implantable cardioverter defibrillator therapy: the role of the wearable cardioverter-defibrillator","volume":"34","author":"Klein","year":"2013","journal-title":"Eur Heart J"},{"key":"10.1016\/j.jjcc.2016.08.004_bib0125","doi-asserted-by":"crossref","first-page":"249","DOI":"10.1253\/circj.CJ-66-0054","article-title":"Guidelines for non-pharmacotherapy of cardiac arrhythmias (JCS 2011)","volume":"77","author":"Okumura","year":"2013","journal-title":"Circ J"},{"key":"10.1016\/j.jjcc.2016.08.004_bib0130","doi-asserted-by":"crossref","first-page":"2581","DOI":"10.1056\/NEJMoa043938","article-title":"Sudden death in patients with myocardial infarction and left ventricular dysfunction, heart failure, or both","volume":"352","author":"Solomon","year":"2005","journal-title":"N Engl J Med"},{"key":"10.1016\/j.jjcc.2016.08.004_bib0135","doi-asserted-by":"crossref","first-page":"216","DOI":"10.1136\/hrt.2008.145243","article-title":"Sudden cardiac death and left ventricular ejection fraction during long-term follow-up after acute myocardial infarction in the primary percutaneous coronary intervention era: results from the HIJAMI-II registry","volume":"95","author":"Shiga","year":"2009","journal-title":"Heart"},{"key":"10.1016\/j.jjcc.2016.08.004_bib0140","doi-asserted-by":"crossref","first-page":"743","DOI":"10.1161\/CIRCULATIONAHA.114.009924","article-title":"Evolution of left ventricular ejection fraction after acute myocardial infarction: implications for implantable cardioverter-defibrillator eligibility","volume":"130","author":"Sjoblom","year":"2014","journal-title":"Circulation"},{"key":"10.1016\/j.jjcc.2016.08.004_bib0145","doi-asserted-by":"crossref","first-page":"1186","DOI":"10.1001\/jamainternmed.2013.1026","article-title":"Association between a hospital's rate of cardiac arrest incidence and cardiac arrest survival","volume":"173","author":"Chen","year":"2013","journal-title":"JAMA Intern Med"},{"key":"10.1016\/j.jjcc.2016.08.004_bib0150","doi-asserted-by":"crossref","first-page":"12","DOI":"10.1186\/s40560-016-0134-7","article-title":"Use of a modified early warning score system to reduce the rate of in-hospital cardiac arrest","volume":"4","author":"Nishijima","year":"2016","journal-title":"J Intensive Care"}],"container-title":["Journal of Cardiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0914508716301794?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0914508716301794?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,12]],"date-time":"2025-10-12T12:58:07Z","timestamp":1760273887000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0914508716301794"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,1]]},"references-count":15,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2017,1]]}},"alternative-id":["S0914508716301794"],"URL":"https:\/\/doi.org\/10.1016\/j.jjcc.2016.08.004","relation":{},"ISSN":["0914-5087"],"issn-type":[{"value":"0914-5087","type":"print"}],"subject":[],"published":{"date-parts":[[2017,1]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Potential roles of the wearable cardioverter-defibrillator in acute phase care of patients at high risk of sudden cardiac death: A single-center Japanese experience","name":"articletitle","label":"Article Title"},{"value":"Journal of Cardiology","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jjcc.2016.08.004","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2016 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.","name":"copyright","label":"Copyright"}]}}