{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,13]],"date-time":"2025-10-13T00:36:40Z","timestamp":1760315800736,"version":"build-2065373602"},"reference-count":17,"publisher":"Elsevier BV","issue":"4","license":[{"start":{"date-parts":[[2022,10,1]],"date-time":"2022-10-01T00:00:00Z","timestamp":1664582400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2022,10,1]],"date-time":"2022-10-01T00:00:00Z","timestamp":1664582400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2023,10,7]],"date-time":"2023-10-07T00:00:00Z","timestamp":1696636800000},"content-version":"vor","delay-in-days":371,"URL":"http:\/\/www.elsevier.com\/open-access\/userlicense\/1.0\/"}],"funder":[{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["U1913210"],"award-info":[{"award-number":["U1913210"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","journal-of-cardiology.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Cardiology"],"published-print":{"date-parts":[[2022,10]]},"DOI":"10.1016\/j.jjcc.2022.05.004","type":"journal-article","created":{"date-parts":[[2022,5,31]],"date-time":"2022-05-31T17:07:43Z","timestamp":1654016863000},"page":"319-324","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"title":["Novel tissue-pressure sensing technology using a wide-band dielectric imaging system: An in vivo study"],"prefix":"10.1016","volume":"80","author":[{"given":"Lei","family":"Ding","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sixian","family":"Weng","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hongda","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Fengyuan","family":"Yu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yingjie","family":"Qi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shu","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Min","family":"Tang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.jjcc.2022.05.004_bb0005","doi-asserted-by":"crossref","first-page":"354","DOI":"10.1161\/CIRCEP.108.803650","article-title":"Novel contact force sensor incorporated in irrigated radiofrequency ablation catheter predicts lesion size and incidence of steam pop and thrombus","volume":"1","author":"Yokoyama","year":"2008","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"10.1016\/j.jjcc.2022.05.004_bb0010","doi-asserted-by":"crossref","first-page":"63","DOI":"10.1161\/CIRCEP.113.001137","article-title":"Target indices for clinical ablation in atrial fibrillation: insights from contact force, electrogram, and biophysical parameter analysis","volume":"7","author":"Ullah","year":"2014","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"10.1016\/j.jjcc.2022.05.004_bb0015","doi-asserted-by":"crossref","first-page":"56","DOI":"10.1093\/europace\/euu218","article-title":"Higher contact-force values associated with better mid-term outcome of paroxysmal atrial fibrillation ablation using the SmartTouch catheter","volume":"17","author":"Providencia","year":"2015","journal-title":"Europace"},{"key":"10.1016\/j.jjcc.2022.05.004_bb0020","doi-asserted-by":"crossref","first-page":"1789","DOI":"10.1016\/j.hrthm.2012.07.016","article-title":"The relationship between contact force and clinical outcome during radiofrequency catheter ablation of atrial fibrillation in the TOCCATA study","volume":"9","author":"Reddy","year":"2012","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.jjcc.2022.05.004_bb0025","doi-asserted-by":"crossref","first-page":"1504","DOI":"10.1111\/pace.14324","article-title":"High anatomical accuracy of a novel high-resolution wide-band dielectric imaging system in cryoballoon-based ablation","volume":"44","author":"Rottner","year":"2021","journal-title":"Pacing Clin Electrophysiol"},{"key":"10.1016\/j.jjcc.2022.05.004_bb0030","doi-asserted-by":"crossref","first-page":"1609","DOI":"10.1093\/europace\/euw295","article-title":"2016 ESC guidelines for the management of atrial fibrillation developed in collaboration with EACTS","volume":"18","author":"Kirchhof","year":"2016","journal-title":"Europace"},{"key":"10.1016\/j.jjcc.2022.05.004_bb0035","doi-asserted-by":"crossref","first-page":"347","DOI":"10.1111\/jce.12886","article-title":"Electromagnetic contact-force sensing electrophysiological catheters: how accurate is the technology?","volume":"27","author":"Bourier","year":"2016","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.jjcc.2022.05.004_bb0040","doi-asserted-by":"crossref","first-page":"109","DOI":"10.1111\/jce.13100","article-title":"Fiberoptic contact-force sensing electrophysiological catheters: how precise is the technology?","volume":"28","author":"Bourier","year":"2017","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.jjcc.2022.05.004_bb0045","doi-asserted-by":"crossref","first-page":"962","DOI":"10.1016\/j.hrthm.2013.03.022","article-title":"Predictive value of impedance changes for real-time contact force measurements during catheter ablation of atrial arrhythmias in humans","volume":"10","author":"Kumar","year":"2013","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.jjcc.2022.05.004_bb0050","doi-asserted-by":"crossref","first-page":"194","DOI":"10.1016\/j.hrthm.2013.10.048","article-title":"Initial impedance decrease as an indicator of good catheter contact: insights from radiofrequency ablation with force sensing catheters","volume":"11","author":"Reichlin","year":"2014","journal-title":"Heart Rhythm"},{"year":"2019","series-title":"Clinical arrhythmology and electrophysiology: A companion to Braunwald\u2019s Heart Disease","author":"Issa","key":"10.1016\/j.jjcc.2022.05.004_bb0055"},{"key":"10.1016\/j.jjcc.2022.05.004_bb0060","doi-asserted-by":"crossref","first-page":"1706","DOI":"10.1016\/0735-1097(93)90600-6","article-title":"Junctional tachycardia: a useful marker during radiofrequency ablation for atrioventricular node reentrant tachycardia","volume":"22","author":"Thakur","year":"1993","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.jjcc.2022.05.004_bb0065","doi-asserted-by":"crossref","first-page":"44","DOI":"10.1136\/heart.85.1.44","article-title":"Slow pathway modification for atriventricular node re-entrant tachycardia: fast juntional tachycardia predicts adverse prognosis","volume":"85","author":"Lipscomb","year":"2001","journal-title":"Heart"},{"key":"10.1016\/j.jjcc.2022.05.004_bb0070","doi-asserted-by":"crossref","first-page":"647","DOI":"10.1016\/j.jacc.2014.04.072","article-title":"Paroxysmal AF catheter ablation with a contact force sensing catheter: results of the prospective, multicenter SMART-AF trial","volume":"64","author":"Natale","year":"2014","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.jjcc.2022.05.004_bb0075","doi-asserted-by":"crossref","first-page":"1344","DOI":"10.1016\/j.jacep.2019.06.020","article-title":"High-resolution imaging of LA anatomy using a novel wide-band dielectric mapping system: first clinical experience","volume":"5","author":"Maurer","year":"2019","journal-title":"JACC Clin Electrophysiol"},{"key":"10.1016\/j.jjcc.2022.05.004_bb0080","doi-asserted-by":"crossref","first-page":"115","DOI":"10.1007\/s00380-021-01902-2","article-title":"Fluoroscopy and contrast media use in cryoballoon ablation of atrial fibrillation using a novel imaging system","volume":"37","author":"Schillaci","year":"2022","journal-title":"Heart Vessel"},{"key":"10.1016\/j.jjcc.2022.05.004_bb0085","doi-asserted-by":"crossref","first-page":"1661","DOI":"10.1016\/j.hrthm.2011.05.017","article-title":"Incidence and predictors of major complications from contemporary catheter ablation to treat cardiac arrhythmias","volume":"8","author":"Bohnen","year":"2011","journal-title":"Heart Rhythm"}],"container-title":["Journal of Cardiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0914508722001071?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0914508722001071?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,12]],"date-time":"2025-10-12T13:07:11Z","timestamp":1760274431000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0914508722001071"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,10]]},"references-count":17,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2022,10]]}},"alternative-id":["S0914508722001071"],"URL":"https:\/\/doi.org\/10.1016\/j.jjcc.2022.05.004","relation":{},"ISSN":["0914-5087"],"issn-type":[{"type":"print","value":"0914-5087"}],"subject":[],"published":{"date-parts":[[2022,10]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Novel tissue-pressure sensing technology using a wide-band dielectric imaging system: An in vivo study","name":"articletitle","label":"Article Title"},{"value":"Journal of Cardiology","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jjcc.2022.05.004","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2022 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.","name":"copyright","label":"Copyright"}]}}