{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,16]],"date-time":"2026-09-16T07:37:24Z","timestamp":1789544244022,"version":"build-2803163510"},"reference-count":18,"publisher":"Elsevier BV","issue":"2","license":[{"start":{"date-parts":[[2026,8,1]],"date-time":"2026-08-01T00:00:00Z","timestamp":1785542400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,8,1]],"date-time":"2026-08-01T00:00:00Z","timestamp":1785542400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2026,4,1]],"date-time":"2026-04-01T00:00:00Z","timestamp":1775001600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100001691","name":"Japan Society for the Promotion of Science","doi-asserted-by":"publisher","award":["23K07573"],"award-info":[{"award-number":["23K07573"]}],"id":[{"id":"10.13039\/501100001691","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","journal-of-cardiology.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Cardiology"],"published-print":{"date-parts":[[2026,8]]},"DOI":"10.1016\/j.jjcc.2026.02.001","type":"journal-article","created":{"date-parts":[[2026,2,6]],"date-time":"2026-02-06T17:06:32Z","timestamp":1770397592000},"page":"95-101","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":1,"title":["Gap between guideline-based indications and real-world implementation of wearable cardioverter-defibrillators after acute myocardial infarction"],"prefix":"10.1016","volume":"88","author":[{"given":"Terumori","family":"Satoh","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yoshihisa","family":"Naruse","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yusuke","family":"Mizuno","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yuichi","family":"Suzuki","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ryota","family":"Sato","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Satoshi","family":"Mogi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Atsushi","family":"Sakamoto","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nobuyuki","family":"Wakahara","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shigetaka","family":"Kageyama","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Masayoshi","family":"Asai","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Keita","family":"Kodama","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hiroyuki","family":"Takase","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kohei","family":"Sawasaki","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yoshitaka","family":"Kawaguchi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yuichiro","family":"Maekawa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"issue":"25","key":"10.1016\/j.jjcc.2026.02.001_bb0005","doi-asserted-by":"crossref","first-page":"2581","DOI":"10.1056\/NEJMoa043938","article-title":"Sudden death in patients with myocardial infarction and left ventricular dysfunction, heart failure, or both","volume":"352","author":"Solomon","year":"2005","journal-title":"N. Engl. J. Med."},{"issue":"7","key":"10.1016\/j.jjcc.2026.02.001_bb0010","doi-asserted-by":"crossref","first-page":"1539","DOI":"10.1253\/circj.CJ-16-0183","article-title":"Clinical impact of ventricular tachycardia and\/or fibrillation during the acute phase of acute myocardial infarction on in-hospital and 5-year mortality rates in the percutaneous coronary intervention era","volume":"80","author":"Masuda","year":"2016","journal-title":"Circ. J."},{"issue":"1","key":"10.1016\/j.jjcc.2026.02.001_bb0015","doi-asserted-by":"crossref","DOI":"10.1136\/openhrt-2016-000405","article-title":"Mortality pattern and cause of death in a long-term follow-up of patients with STEMI treated with primary PCI","volume":"3","author":"Doost Hosseiny","year":"2016","journal-title":"Open Heart"},{"issue":"24","key":"10.1016\/j.jjcc.2026.02.001_bb0020","doi-asserted-by":"crossref","first-page":"2481","DOI":"10.1056\/NEJMoa041489","article-title":"Prophylactic use of an implantable cardioverter-defibrillator after acute myocardial infarction","volume":"351","author":"Hohnloser","year":"2004","journal-title":"N. Engl. J. Med."},{"issue":"15","key":"10.1016\/j.jjcc.2026.02.001_bb0025","doi-asserted-by":"crossref","first-page":"1427","DOI":"10.1056\/NEJMoa0901889","article-title":"Defibrillator implantation early after myocardial infarction","volume":"361","author":"Steinbeck","year":"2009","journal-title":"N. Engl. J. Med."},{"issue":"7","key":"10.1016\/j.jjcc.2026.02.001_bb0030","doi-asserted-by":"crossref","first-page":"1104","DOI":"10.1253\/circj.CJ-20-0637","article-title":"JCS\/JHRS 2019 guideline on non-pharmacotherapy of cardiac arrhythmias","volume":"85","author":"Nogami","year":"2021","journal-title":"Circ. J."},{"issue":"2","key":"10.1016\/j.jjcc.2026.02.001_bb0035","doi-asserted-by":"crossref","first-page":"381","DOI":"10.1253\/circj.CJ-14-0925","article-title":"Current status of primary prevention of sudden cardiac death with implantable cardioverter defibrillator in patients with chronic heart failure--a report from the CHART-2 Study","volume":"79","author":"Satake","year":"2015","journal-title":"Circ. J."},{"issue":"18","key":"10.1016\/j.jjcc.2026.02.001_bb0040","doi-asserted-by":"crossref","first-page":"2231","DOI":"10.1016\/j.jacc.2018.08.1038","article-title":"Fourth universal definition of myocardial infarction (2018)","volume":"72","author":"Thygesen","year":"2018","journal-title":"J. Am. Coll. Cardiol."},{"issue":"7578","key":"10.1016\/j.jjcc.2026.02.001_bb0045","doi-asserted-by":"crossref","first-page":"1091","DOI":"10.1136\/bmj.38985.646481.55","article-title":"Prediction of risk of death and myocardial infarction in the six months after presentation with acute coronary syndrome: prospective multinational observational study (GRACE)","volume":"333","author":"Fox","year":"2006","journal-title":"BMJ"},{"issue":"17","key":"10.1016\/j.jjcc.2026.02.001_bb0050","doi-asserted-by":"crossref","first-page":"1779","DOI":"10.1001\/jama.2009.600","article-title":"Incidence of and outcomes associated with ventricular tachycardia or fibrillation in patients undergoing primary percutaneous coronary intervention","volume":"301","author":"Mehta","year":"2009","journal-title":"Jama"},{"issue":"6","key":"10.1016\/j.jjcc.2026.02.001_bb0055","doi-asserted-by":"crossref","first-page":"805","DOI":"10.1016\/j.amjcard.2011.10.043","article-title":"Prognostic significance of postprocedural sustained ventricular tachycardia or fibrillation in patients undergoing primary percutaneous coronary intervention (from the HORIZONS-AMI trial)","volume":"109","author":"Mehta","year":"2012","journal-title":"Am. J. Cardiol."},{"issue":"3","key":"10.1016\/j.jjcc.2026.02.001_bb0060","doi-asserted-by":"crossref","first-page":"170","DOI":"10.1016\/j.jjcc.2024.02.006","article-title":"Long-term prognosis and prognostic factors after primary prophylactic implantable cardioverter-defibrillator therapy","volume":"84","author":"Sugawara","year":"2024","journal-title":"J. Cardiol."},{"issue":"13","key":"10.1016\/j.jjcc.2026.02.001_bb0065","first-page":"e272","volume":"138","author":"Al-Khatib","year":"2018","journal-title":"Circulation"},{"issue":"40","key":"10.1016\/j.jjcc.2026.02.001_bb0070","doi-asserted-by":"crossref","first-page":"3997","DOI":"10.1093\/eurheartj\/ehac262","article-title":"2022 ESC guidelines for the management of patients with ventricular arrhythmias and the prevention of sudden cardiac death","volume":"43","author":"Zeppenfeld","year":"2022","journal-title":"Eur. Heart J."},{"issue":"6","key":"10.1016\/j.jjcc.2026.02.001_bb0075","doi-asserted-by":"crossref","first-page":"1462","DOI":"10.1002\/joa3.13158","article-title":"Clinical outcomes during and after wearable cardioverter defibrillator use in Japanese patients with heart failure: a single-center experience","volume":"40","author":"Kikuchi","year":"2024","journal-title":"J Arrhythm."},{"issue":"4","key":"10.1016\/j.jjcc.2026.02.001_bb0080","doi-asserted-by":"crossref","first-page":"998","DOI":"10.1002\/joa3.13113","article-title":"Current status of wearable cardioverter-defibrillator use in Japan","volume":"40","author":"Tonegawa-Kuji","year":"2024","journal-title":"J Arrhythm"},{"issue":"1","key":"10.1016\/j.jjcc.2026.02.001_bb0085","doi-asserted-by":"crossref","first-page":"117","DOI":"10.1161\/CIRCEP.112.973552","article-title":"Early risk of mortality after coronary artery revascularization in patients with left ventricular dysfunction and potential role of the wearable cardioverter defibrillator","volume":"6","author":"Zishiri","year":"2013","journal-title":"Circ. Arrhythm. Electrophysiol."},{"issue":"1","key":"10.1016\/j.jjcc.2026.02.001_bb0090","doi-asserted-by":"crossref","first-page":"53","DOI":"10.1007\/s12928-021-00788-1","article-title":"Wearable cardioverter-defibrillators after myocardial infarction: a review of its clinical utility and unmet needs in current clinical practice","volume":"37","author":"Hioki","year":"2022","journal-title":"Cardiovasc. Interv. Ther."}],"container-title":["Journal of Cardiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0914508726000298?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0914508726000298?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,8,1]],"date-time":"2026-08-01T01:41:38Z","timestamp":1785548498000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0914508726000298"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,8]]},"references-count":18,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2026,8]]}},"alternative-id":["S0914508726000298"],"URL":"https:\/\/doi.org\/10.1016\/j.jjcc.2026.02.001","relation":{},"ISSN":["0914-5087"],"issn-type":[{"value":"0914-5087","type":"print"}],"subject":[],"published":{"date-parts":[[2026,8]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Gap between guideline-based indications and real-world implementation of wearable cardioverter-defibrillators after acute myocardial infarction","name":"articletitle","label":"Article Title"},{"value":"Journal of Cardiology","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jjcc.2026.02.001","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2026 The Authors. Published by Elsevier Ltd on behalf of Japanese College of Cardiology.","name":"copyright","label":"Copyright"}]}}