{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,18]],"date-time":"2026-04-18T07:57:43Z","timestamp":1776499063286,"version":"3.51.2"},"reference-count":34,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2014,3,1]],"date-time":"2014-03-01T00:00:00Z","timestamp":1393632000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2014,3,1]],"date-time":"2014-03-01T00:00:00Z","timestamp":1393632000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of the Mechanical Behavior of Biomedical Materials"],"published-print":{"date-parts":[[2014,3]]},"DOI":"10.1016\/j.jmbbm.2013.03.011","type":"journal-article","created":{"date-parts":[[2013,4,17]],"date-time":"2013-04-17T15:16:59Z","timestamp":1366211819000},"page":"100-106","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":12,"special_numbering":"C","title":["Grafting of poly(2-methacryloyloxyethyl phosphorylcholine) on polyethylene liner in artificial hip joints reduces production of wear particles"],"prefix":"10.1016","volume":"31","author":[{"given":"Toru","family":"Moro","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Masayuki","family":"Kyomoto","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kazuhiko","family":"Ishihara","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kenichi","family":"Saiga","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Masami","family":"Hashimoto","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sakae","family":"Tanaka","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hideya","family":"Ito","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takeyuki","family":"Tanaka","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hirofumi","family":"Oshima","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hiroshi","family":"Kawaguchi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yoshio","family":"Takatori","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.jmbbm.2013.03.011_bib1","first-page":"128","article-title":"The epidemiology of revision total hip arthroplasty in the United States","volume":"91","author":"Bozic","year":"2009","journal-title":"Journal of Bone & Joint Surgery"},{"issue":"Suppl. 1","key":"10.1016\/j.jmbbm.2013.03.011_bib2","doi-asserted-by":"crossref","first-page":"S33","DOI":"10.5435\/00124635-200800001-00008","article-title":"How have alternative bearings (such as metal-on-metal, highly cross-linked polyethylene, and ceramic-on-ceramic) affected the prevention and treatment of osteolysis?","volume":"16","author":"Callaghan","year":"2008","journal-title":"Journal of the American Academy of Orthopaedic Surgeons"},{"key":"10.1016\/j.jmbbm.2013.03.011_bib3","doi-asserted-by":"crossref","first-page":"167","DOI":"10.1243\/PIME_PROC_1996_210_409_02","article-title":"Wear and morphology of ultra-high molecular weight polyethylene wear particles from total hip replacements","volume":"210","author":"Campbell","year":"1996","journal-title":"Proceedings of the Institution of Mechanical Engineers Part H"},{"key":"10.1016\/j.jmbbm.2013.03.011_bib4","first-page":"3","article-title":"Biologic activity of wear particles","volume":"59","author":"Catelas","year":"2010","journal-title":"Instructional Course Lectures"},{"key":"10.1016\/j.jmbbm.2013.03.011_bib5","doi-asserted-by":"crossref","first-page":"1129","DOI":"10.1016\/S0140-6736(61)92063-3","article-title":"Arthroplasty of the hip. A new operation","volume":"1","author":"Charnley","year":"1961","journal-title":"Lancet"},{"key":"10.1016\/j.jmbbm.2013.03.011_bib6","first-page":"452","article-title":"The effect of ultra-high molecular weight polyethylene wear debris on MG63 osteosarcoma cells in vitro","volume":"81","author":"Dean","year":"1999","journal-title":"Journal of Bone and Joint Surgery\u2014American Volume"},{"key":"10.1016\/j.jmbbm.2013.03.011_bib7","doi-asserted-by":"crossref","first-page":"265","DOI":"10.1097\/01.blo.0000238856.61862.7d","article-title":"The basis for a second-generation highly cross-linked UHMWPE","volume":"453","author":"Dumbleton","year":"2006","journal-title":"Clinical Orthopaedics and Related Research"},{"key":"10.1016\/j.jmbbm.2013.03.011_bib8","doi-asserted-by":"crossref","first-page":"114","DOI":"10.1097\/01.blo.0000148783.20469.4c","article-title":"Wear, debris, and biologic activity of cross-linked polyethylene in the knee: benefits and potential concerns","volume":"428","author":"Fisher","year":"2004","journal-title":"Clinical Orthopaedics and Related Research"},{"key":"10.1016\/j.jmbbm.2013.03.011_bib9","doi-asserted-by":"crossref","first-page":"464","DOI":"10.1016\/S0883-5403(98)90016-X","article-title":"Early osteolysis with Hylamer acetabular liners","volume":"13","author":"Graeter","year":"1998","journal-title":"Journal of Arthroplasty"},{"key":"10.1016\/j.jmbbm.2013.03.011_bib10","doi-asserted-by":"crossref","first-page":"39","DOI":"10.1097\/01.blo.0000149821.72760.39","article-title":"Conquest of a worldwide human disease: particle-induced periprosthetic osteolysis","volume":"429","author":"Harris","year":"2004","journal-title":"Clinical Orthopaedics and Related Research"},{"key":"10.1016\/j.jmbbm.2013.03.011_bib11","doi-asserted-by":"crossref","first-page":"526","DOI":"10.3109\/17453674.2010.519169","article-title":"Effects of metal-on-metal wear on the host immune system and infection in hip arthroplasty","volume":"81","author":"Hosman","year":"2010","journal-title":"Acta Orthopaedica"},{"key":"10.1016\/j.jmbbm.2013.03.011_bib12","doi-asserted-by":"crossref","first-page":"203","DOI":"10.1016\/j.arth.2009.02.006","article-title":"Hylamer vs conventional polyethylene in primary total hip arthroplasty: a long-term case-control study of wear rates and osteolysis","volume":"25","author":"Huddleston","year":"2010","journal-title":"Journal of Arthroplasty"},{"key":"10.1016\/j.jmbbm.2013.03.011_bib13","doi-asserted-by":"crossref","first-page":"325","DOI":"10.1016\/S0927-7765(99)00158-7","article-title":"Photoinduced graft polymerization of 2-methacryloyloxyethyl phosphorylcholine on polyethylene membrane surface for obtaining blood cell adhesion resistance","volume":"18","author":"Ishihara","year":"2000","journal-title":"Colloids and Surfaces B: Biointerfaces"},{"key":"10.1016\/j.jmbbm.2013.03.011_bib14","doi-asserted-by":"crossref","first-page":"355","DOI":"10.1295\/polymj.22.355","article-title":"Preparation of phospholipid polymers and their properties as polymer hydrogel membrane","volume":"22","author":"Ishihara","year":"1990","journal-title":"Polymer Journal"},{"key":"10.1016\/j.jmbbm.2013.03.011_bib15","doi-asserted-by":"crossref","first-page":"71","DOI":"10.1097\/00003086-200112000-00008","article-title":"Osteolysis: basic science","volume":"393","author":"Jacobs","year":"2001","journal-title":"Clinical Orthopaedics and Related Research"},{"key":"10.1016\/j.jmbbm.2013.03.011_bib16","first-page":"1","article-title":"Wear and osteolysis in total joint replacements","volume":"278","author":"Kadoya","year":"1998","journal-title":"Acta Orthopaedica Scandinavica"},{"key":"10.1016\/j.jmbbm.2013.03.011_bib17","doi-asserted-by":"crossref","first-page":"188","DOI":"10.1046\/j.1525-1594.2003.t01-2-06993.x","article-title":"In vivo evaluation of a MPC polymer coated continuous flow left ventricular assist system","volume":"27","author":"Kihara","year":"2003","journal-title":"Artificial Organs"},{"key":"10.1016\/j.jmbbm.2013.03.011_bib18","doi-asserted-by":"crossref","first-page":"10260","DOI":"10.1021\/la0349673","article-title":"Structure of water in the vicinity of phospholipid analogue copolymers as studied by vibrational spectroscopy","volume":"19","author":"Kitano","year":"2003","journal-title":"Langmuir"},{"key":"10.1016\/j.jmbbm.2013.03.011_bib19","doi-asserted-by":"crossref","first-page":"698","DOI":"10.1016\/S0002-9149(99)00843-7","article-title":"Early mobilization after protamine reversal of heparin following implantation of phosphorylcholine-coated stents in totally occluded coronary arteries","volume":"85","author":"Kuiper","year":"2000","journal-title":"American Journal of Cardiology"},{"key":"10.1016\/j.jmbbm.2013.03.011_bib20","first-page":"1809","article-title":"Effects of photo-induced graft polymerization of 2-methacryloyloxyethyl phosphorylcholine on physical properties of cross-linked polyethylene in artificial hip joints","volume":"18","author":"Kyomoto","year":"2007","journal-title":"Journal of Materials Science: Materials in Medicine"},{"key":"10.1016\/j.jmbbm.2013.03.011_bib21","doi-asserted-by":"crossref","first-page":"320","DOI":"10.1002\/jbm.b.30874","article-title":"Enhanced wear resistance of orthopaedic bearing due to the cross-linking of poly(MPC) graft chains induced by gamma-ray irradiation","volume":"84","author":"Kyomoto","year":"2008","journal-title":"Journal of Biomedical Materials Research Part B: Applied Biomaterials"},{"key":"10.1016\/j.jmbbm.2013.03.011_bib22","doi-asserted-by":"crossref","first-page":"2327","DOI":"10.1007\/s11999-010-1718-5","article-title":"Cartilage-mimicking, high-density brush structure improves wear resistance of crosslinked polyethylene: a pilot study","volume":"469","author":"Kyomoto","year":"2011","journal-title":"Clinical Orthopaedics and Related Research"},{"key":"10.1016\/j.jmbbm.2013.03.011_bib23","doi-asserted-by":"crossref","first-page":"2995","DOI":"10.1016\/j.biomaterials.2009.02.020","article-title":"Wear resistance of artificial hip joints with poly(2-methacryloyloxyethyl phosphorylcholine) grafted polyethylene: comparisons with the effect of polyethylene cross-linking and ceramic femoral heads","volume":"30","author":"Moro","year":"2009","journal-title":"Biomaterials"},{"key":"10.1016\/j.jmbbm.2013.03.011_bib24","doi-asserted-by":"crossref","first-page":"829","DOI":"10.1038\/nmat1233","article-title":"Surface grafting of artificial joints with a biocompatible polymer for preventing periprosthetic osteolysis","volume":"3","author":"Moro","year":"2004","journal-title":"Nature Materials"},{"key":"10.1016\/j.jmbbm.2013.03.011_bib25","doi-asserted-by":"crossref","first-page":"58","DOI":"10.1097\/01.blo.0000246553.33434.5f","article-title":"2006 Frank Stinchfield Award: grafting of biocompatible polymer for longevity of artificial hip joints","volume":"453","author":"Moro","year":"2006","journal-title":"Clinical Orthopaedics and Related Research"},{"key":"10.1016\/j.jmbbm.2013.03.011_bib26","doi-asserted-by":"crossref","first-page":"1174","DOI":"10.1016\/j.joca.2010.05.019","article-title":"Surface grafting of biocompatible phospholipid polymer MPC provides wear resistance of tibial polyethylene insert in artificial knee joints","volume":"18","author":"Moro","year":"2010","journal-title":"Osteoarthritis Cartilage"},{"key":"10.1016\/j.jmbbm.2013.03.011_bib27","doi-asserted-by":"crossref","first-page":"149","DOI":"10.1054\/arth.2001.20540","article-title":"A novel method of cross-linking ultra-high-molecular-weight polyethylene to improve wear, reduce oxidation, and retain mechanical properties. Recipient of the 1999 HAP Paul Award","volume":"16","author":"Muratoglu","year":"2001","journal-title":"Journal of Arthroplasty"},{"key":"10.1016\/j.jmbbm.2013.03.011_bib28","doi-asserted-by":"crossref","first-page":"580","DOI":"10.1016\/j.arth.2005.07.009","article-title":"Wear resistance and mechanical properties of highly cross-linked, ultrahigh-molecular weight polyethylene doped with vitamin E","volume":"21","author":"Oral","year":"2006","journal-title":"Journal of Arthroplasty"},{"key":"10.1016\/j.jmbbm.2013.03.011_bib29","doi-asserted-by":"crossref","first-page":"4785","DOI":"10.1016\/j.biomaterials.2003.12.034","article-title":"Biological evaluation and drug delivery application of cationically modified phospholipid polymers","volume":"25","author":"Palmer","year":"2004","journal-title":"Biomaterials"},{"key":"10.1016\/j.jmbbm.2013.03.011_bib30","first-page":"8","article-title":"Forces transmitted by joints in the human body","volume":"181","author":"Paul","year":"1967","journal-title":"Proceedings of the Institution of Mechanical Engineers"},{"key":"10.1016\/j.jmbbm.2013.03.011_bib31","doi-asserted-by":"crossref","first-page":"134","DOI":"10.1016\/j.ajo.2008.07.032","article-title":"Phosphorylcholine impairs susceptibility to biofilm formation of hydrogel contact lenses","volume":"147","author":"Selan","year":"2009","journal-title":"American Journal of Ophthalmology"},{"key":"10.1016\/j.jmbbm.2013.03.011_bib32","doi-asserted-by":"crossref","first-page":"395","DOI":"10.1007\/s11999-010-1555-6","article-title":"Wear versus thickness and other features of 5-Mrad crosslinked UHMWPE acetabular liners","volume":"469","author":"Shen","year":"2011","journal-title":"Clinical Orthopaedics and Related Research"},{"key":"10.1016\/j.jmbbm.2013.03.011_bib33","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1002\/jbm.a.31006","article-title":"Preclinical biocompatibility assessment of the EVAHEART ventricular assist device: coating comparison and platelet activation","volume":"81","author":"Snyder","year":"2007","journal-title":"Journal of Biomedical Materials Research Part A"},{"key":"10.1016\/j.jmbbm.2013.03.011_bib34","doi-asserted-by":"crossref","first-page":"473","DOI":"10.1002\/jbm.a.30824","article-title":"Isolation and characterization of UHMWPE wear particles down to ten nanometers in size from in vitro hip and knee joint simulators","volume":"78","author":"Tipper","year":"2006","journal-title":"Journal of Biomedical Materials Research Part A"}],"container-title":["Journal of the Mechanical Behavior of Biomedical Materials"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1751616113000970?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1751616113000970?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,28]],"date-time":"2025-10-28T22:02:53Z","timestamp":1761688973000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1751616113000970"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,3]]},"references-count":34,"alternative-id":["S1751616113000970"],"URL":"https:\/\/doi.org\/10.1016\/j.jmbbm.2013.03.011","relation":{},"ISSN":["1751-6161"],"issn-type":[{"value":"1751-6161","type":"print"}],"subject":[],"published":{"date-parts":[[2014,3]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Grafting of poly(2-methacryloyloxyethyl phosphorylcholine) on polyethylene liner in artificial hip joints reduces production of wear particles","name":"articletitle","label":"Article Title"},{"value":"Journal of the Mechanical Behavior of Biomedical Materials","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jmbbm.2013.03.011","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2013 Elsevier Ltd. All rights reserved.","name":"copyright","label":"Copyright"}]}}