{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,29]],"date-time":"2025-10-29T03:13:14Z","timestamp":1761707594631,"version":"build-2065373602"},"reference-count":27,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2018,3,1]],"date-time":"2018-03-01T00:00:00Z","timestamp":1519862400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2018,3,1]],"date-time":"2018-03-01T00:00:00Z","timestamp":1519862400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"funder":[{"DOI":"10.13039\/100012895","name":"Zoetis","doi-asserted-by":"crossref","award":["SFMVRE29"],"award-info":[{"award-number":["SFMVRE29"]}],"id":[{"id":"10.13039\/100012895","id-type":"DOI","asserted-by":"crossref"}]},{"DOI":"10.13039\/501100000038","name":"NSERC","doi-asserted-by":"crossref","award":["RGPIN-2016-05472"],"award-info":[{"award-number":["RGPIN-2016-05472"]}],"id":[{"id":"10.13039\/501100000038","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of the Mechanical Behavior of Biomedical Materials"],"published-print":{"date-parts":[[2018,3]]},"DOI":"10.1016\/j.jmbbm.2017.12.024","type":"journal-article","created":{"date-parts":[[2017,12,26]],"date-time":"2017-12-26T13:09:22Z","timestamp":1514293762000},"page":"239-245","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":5,"special_numbering":"C","title":["Quasi-static tensile properties of the Cranial Cruciate Ligament (CrCL) in adult cattle: towards the design of a prosthetic CrCL"],"prefix":"10.1016","volume":"79","author":[{"given":"Lucien","family":"Diotalevi","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yvan","family":"Petit","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Vladimir","family":"Brailovski","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sylvain","family":"Nichols","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Emma","family":"Marchionatti","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"\u00c9ric","family":"Wagnac","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"issue":"5","key":"10.1016\/j.jmbbm.2017.12.024_bib1","doi-asserted-by":"crossref","first-page":"151","DOI":"10.1111\/j.1740-8261.1975.tb00696.x","article-title":"Femoral-tibial osteoarthrosis in the bull: I. Clinical survey and radiologic interpretation","volume":"16","author":"Bartels","year":"1975","journal-title":"Vet. Radiol."},{"issue":"5","key":"10.1016\/j.jmbbm.2017.12.024_bib2","doi-asserted-by":"crossref","first-page":"159","DOI":"10.1111\/j.1740-8261.1975.tb00697.x","article-title":"Femoral-tibial osteoarthrosis in the bull: II. A correlation of the radiographic and pathologic findings of the torn meniscus and ruptured cranial cruciate ligament","volume":"16","author":"Bartels","year":"1975","journal-title":"Vet. Radiol."},{"issue":"3","key":"10.1016\/j.jmbbm.2017.12.024_bib3","doi-asserted-by":"crossref","first-page":"328","DOI":"10.1177\/036354659402200306","article-title":"The effects of donor age and strain rate on the biomechanical properties of bone-patellar tendon-bone allografts","volume":"22","author":"Blevins","year":"1994","journal-title":"Am. J. Sports Med."},{"issue":"6","key":"10.1016\/j.jmbbm.2017.12.024_bib4","doi-asserted-by":"crossref","first-page":"573","DOI":"10.3928\/0147-7447-20000601-15","article-title":"Mechanisms of anterior cruciate ligament injury","volume":"23","author":"Boden","year":"2000","journal-title":"Orthopedics"},{"key":"10.1016\/j.jmbbm.2017.12.024_bib5","doi-asserted-by":"crossref","first-page":"261","DOI":"10.1016\/j.jmbbm.2014.07.004","article-title":"Strain-rate sensitivity of the lateral collateral ligament of the knee","volume":"41","author":"Bonner","year":"2015","journal-title":"J. Mech. Behav. Biomed. Mater."},{"issue":"16","key":"10.1016\/j.jmbbm.2017.12.024_bib6","doi-asserted-by":"crossref","first-page":"2943","DOI":"10.1016\/j.jbiomech.2005.10.031","article-title":"Sex-based differences in the tensile properties of the human anterior cruciate ligament","volume":"39","author":"Chandrashekar","year":"2006","journal-title":"J. Biomech."},{"issue":"3","key":"10.1016\/j.jmbbm.2017.12.024_bib7","doi-asserted-by":"crossref","first-page":"270","DOI":"10.1111\/j.1532-950X.2010.00653.x","article-title":"Cranial cruciate ligament disease in dogs: biology versus biomechanics","volume":"39","author":"Cook","year":"2010","journal-title":"Vet. Surg."},{"issue":"7","key":"10.1016\/j.jmbbm.2017.12.024_bib8","first-page":"212","article-title":"Stifle lameness in cattle at two veterinary teaching hospitals: a retrospective study of forty-two cases","volume":"26","author":"Ducharme","year":"1985","journal-title":"Can. Vet. J."},{"issue":"8","key":"10.1016\/j.jmbbm.2017.12.024_bib9","doi-asserted-by":"crossref","first-page":"579","DOI":"10.1016\/0021-9290(84)90090-3","article-title":"Effects of structure and strain measurement technique on the material properties of young human tendons and fascia","volume":"17","author":"Grood","year":"1984","journal-title":"J. Biomech."},{"issue":"2","key":"10.1016\/j.jmbbm.2017.12.024_bib10","doi-asserted-by":"crossref","first-page":"178","DOI":"10.2460\/javma.1971.158.02.178","article-title":"Anterior cruciate ligament repair in cattle","volume":"158","author":"Hamilton","year":"1971","journal-title":"J. Am. Vet. Med. Assoc."},{"issue":"9","key":"10.1016\/j.jmbbm.2017.12.024_bib11","doi-asserted-by":"crossref","first-page":"1135","DOI":"10.1016\/S0021-9290(01)00078-1","article-title":"Circumferential measurement and analysis of strain distribution in the human ACL using a photoelastic coating method","volume":"34","author":"Hirokawa","year":"2001","journal-title":"J. Biomech."},{"issue":"6","key":"10.1016\/j.jmbbm.2017.12.024_bib12","doi-asserted-by":"crossref","first-page":"184","DOI":"10.1111\/j.1740-8261.1986.tb00033.x","article-title":"Radiographic assessment of cranial cruciate ligament rupture in the dairy cow","volume":"27","author":"Huhn","year":"1986","journal-title":"Vet. Radiol."},{"issue":"8","key":"10.1016\/j.jmbbm.2017.12.024_bib13","doi-asserted-by":"crossref","first-page":"1193","DOI":"10.1002\/jor.21373","article-title":"The effects of multiple freeze-thaw cycles on the biomechanical properties of the human bone-patellar tendon-bone allograft","volume":"29","author":"Jung","year":"2011","journal-title":"J. Orthop. Res."},{"issue":"2","key":"10.1016\/j.jmbbm.2017.12.024_bib14","doi-asserted-by":"crossref","first-page":"147","DOI":"10.1115\/1.2891165","article-title":"The effects of temperature on the viscoelastic properties of the rabbit medial collateral ligament","volume":"112","author":"Lam","year":"1990","journal-title":"J. Biomech. Eng."},{"issue":"4","key":"10.1016\/j.jmbbm.2017.12.024_bib15","doi-asserted-by":"crossref","first-page":"350","DOI":"10.1115\/1.3168390","article-title":"A new device to measure the structural properties of the femur-anterior cruciate ligament-tibia complex","volume":"111","author":"Lyon","year":"1989","journal-title":"J. Biomech. Eng."},{"issue":"6","key":"10.1016\/j.jmbbm.2017.12.024_bib16","doi-asserted-by":"crossref","first-page":"1153","DOI":"10.1016\/j.jbiomech.2005.02.012","article-title":"The effects of refreezing on the viscoelastic and tensile properties of ligaments","volume":"39","author":"Moon","year":"2006","journal-title":"J. Biomech."},{"issue":"9","key":"10.1016\/j.jmbbm.2017.12.024_bib17","doi-asserted-by":"crossref","first-page":"1408","DOI":"10.2460\/ajvr.1980.41.09.1408","article-title":"Tensile strength of the cranial cruciate ligament in cattle","volume":"41","author":"Moss","year":"1980","journal-title":"Am. J. Vet. Res."},{"issue":"2","key":"10.1016\/j.jmbbm.2017.12.024_bib18","first-page":"157","article-title":"Experimental cranial cruciate replacement in cattle using a patellar ligament graft","volume":"29","author":"Moss","year":"1988","journal-title":"Can. Vet. J."},{"issue":"3","key":"10.1016\/j.jmbbm.2017.12.024_bib19","doi-asserted-by":"crossref","first-page":"381","DOI":"10.2460\/ajvr.74.3.381","article-title":"Comparison of the mechanical characteristics of polymerized caprolactam and monofilament nylon loops constructed in parallel strands or as braided ropes versus cranial cruciate ligaments of cattle","volume":"74","author":"Niehaus","year":"2013","journal-title":"Am. J. Vet. Res."},{"issue":"1","key":"10.1016\/j.jmbbm.2017.12.024_bib20","first-page":"265","article-title":"Stifle disorders: cranial cruciate ligament, meniscus, upward fixation of the patella","volume":"30","author":"Pentecost","year":"2014","journal-title":"Bov. Orthop."},{"issue":"2","key":"10.1016\/j.jmbbm.2017.12.024_bib21","doi-asserted-by":"crossref","first-page":"95","DOI":"10.1016\/S1350-4533(99)00028-4","article-title":"Strain rate effect on the mechanical behavior of the anterior cruciate ligament-bone complex","volume":"21","author":"Pioletti","year":"1999","journal-title":"Med. Eng. Phys."},{"issue":"4","key":"10.1016\/j.jmbbm.2017.12.024_bib22","doi-asserted-by":"crossref","first-page":"493","DOI":"10.1016\/j.knee.2011.07.005","article-title":"A comparative anatomical study of the human knee and six animal species","volume":"19","author":"Proffen","year":"2012","journal-title":"Knee"},{"issue":"4","key":"10.1016\/j.jmbbm.2017.12.024_bib23","doi-asserted-by":"crossref","first-page":"257","DOI":"10.1111\/j.1532-950X.1994.tb00480.x","article-title":"In vitro mechanical properties and failure mode of the equine (pony) cranial cruciate ligament","volume":"23","author":"Rich","year":"1994","journal-title":"Vet. Surg."},{"issue":"3","key":"10.1016\/j.jmbbm.2017.12.024_bib24","doi-asserted-by":"crossref","first-page":"217","DOI":"10.1177\/036354659101900303","article-title":"Tensile properties of the human femur-anterior cruciate ligament-tibia complex.\u00a0The effects of specimen age and orientation","volume":"19","author":"Woo","year":"1991","journal-title":"Am. J. Sports Med."},{"issue":"1","key":"10.1016\/j.jmbbm.2017.12.024_bib25","doi-asserted-by":"crossref","first-page":"68","DOI":"10.1115\/1.3138645","article-title":"Temperature dependent behavior of the canine medial collateral ligament","volume":"109","author":"Woo","year":"1987","journal-title":"J. Biomech. Eng."},{"issue":"5","key":"10.1016\/j.jmbbm.2017.12.024_bib26","doi-asserted-by":"crossref","first-page":"399","DOI":"10.1016\/0021-9290(86)90016-3","article-title":"Effects of postmortem storage by freezing on ligament tensile behavior","volume":"19","author":"Woo","year":"1986","journal-title":"J. Biomech."},{"issue":"1","key":"10.1016\/j.jmbbm.2017.12.024_bib27","doi-asserted-by":"crossref","first-page":"58","DOI":"10.1016\/S0934-8832(11)80138-1","article-title":"A scanning electron microscopic study of rabbit ligaments under strain","volume":"10","author":"Yahia","year":"1990","journal-title":"Matrix"}],"container-title":["Journal of the Mechanical Behavior of Biomedical Materials"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1751616117305702?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1751616117305702?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,28]],"date-time":"2025-10-28T22:18:47Z","timestamp":1761689927000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1751616117305702"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,3]]},"references-count":27,"alternative-id":["S1751616117305702"],"URL":"https:\/\/doi.org\/10.1016\/j.jmbbm.2017.12.024","relation":{},"ISSN":["1751-6161"],"issn-type":[{"type":"print","value":"1751-6161"}],"subject":[],"published":{"date-parts":[[2018,3]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Quasi-static tensile properties of the Cranial Cruciate Ligament (CrCL) in adult cattle: towards the design of a prosthetic CrCL","name":"articletitle","label":"Article Title"},{"value":"Journal of the Mechanical Behavior of Biomedical Materials","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jmbbm.2017.12.024","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2018 Elsevier Ltd. All rights reserved.","name":"copyright","label":"Copyright"}]}}