{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,7]],"date-time":"2026-09-07T22:52:05Z","timestamp":1788821525363,"version":"build-2803163510"},"reference-count":46,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2020,11,1]],"date-time":"2020-11-01T00:00:00Z","timestamp":1604188800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2020,11,1]],"date-time":"2020-11-01T00:00:00Z","timestamp":1604188800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of the Mechanical Behavior of Biomedical Materials"],"published-print":{"date-parts":[[2020,11]]},"DOI":"10.1016\/j.jmbbm.2020.104007","type":"journal-article","created":{"date-parts":[[2020,8,6]],"date-time":"2020-08-06T21:15:51Z","timestamp":1596748551000},"page":"104007","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":25,"special_numbering":"C","title":["Biomechanical comparison of titanium miniplates versus a variety of CAD\/CAM plates in mandibular reconstruction"],"prefix":"10.1016","volume":"111","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-4221-4878","authenticated-orcid":false,"given":"Claudius","family":"Steffen","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kay","family":"Sellenschloh","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Matthias","family":"Vollmer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael M.","family":"Morlock","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Max","family":"Heiland","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gerd","family":"Huber","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Carsten","family":"Rendenbach","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.jmbbm.2020.104007_bib1","doi-asserted-by":"crossref","first-page":"759","DOI":"10.1067\/moe.2000.105942","article-title":"Effect of interference of metallic objects on interpretation of T1-weighted magnetic resonance images in the maxillofacial region","volume":"89","author":"Abbaszadeh","year":"2000","journal-title":"Oral Surg. Oral Med. Oral Pathol. Oral Radiol. Endod."},{"key":"10.1016\/j.jmbbm.2020.104007_bib2","doi-asserted-by":"crossref","first-page":"314","DOI":"10.1097\/SAP.0000000000000497","article-title":"Miniplates versus reconstruction bars for oncologic free fibula flap mandible reconstruction","volume":"77","author":"Al-Bustani","year":"2016","journal-title":"Ann. Plast. Surg."},{"key":"10.1016\/j.jmbbm.2020.104007_bib3","doi-asserted-by":"crossref","first-page":"217","DOI":"10.1080\/17453674.2016.1256940","article-title":"Modulation of fixation stiffness from flexible to stiff in a rat model of bone healing","volume":"88","author":"Bartnikowski","year":"2017","journal-title":"Acta Orthop."},{"key":"10.1016\/j.jmbbm.2020.104007_bib4","doi-asserted-by":"crossref","first-page":"113","DOI":"10.1016\/j.bjoms.2016.12.010","article-title":"Mandibular reconstruction with vascularised bone flaps: a systematic review over 25 years","volume":"55","author":"Brown","year":"2017","journal-title":"Br. J. Oral Maxillofac. Surg."},{"key":"10.1016\/j.jmbbm.2020.104007_bib5","doi-asserted-by":"crossref","first-page":"S132","DOI":"10.1097\/00003086-199810001-00015","article-title":"Effects of mechanical factors on the fracture healing process","author":"Claes","year":"1998","journal-title":"Clin. Orthop. Relat. Res."},{"key":"10.1016\/j.jmbbm.2020.104007_bib6","first-page":"S17","article-title":"The concept of locking plates","volume":"96","author":"Cronier","year":"2010","journal-title":"J. Orthop. Traumatol.: Surg. Res."},{"key":"10.1016\/j.jmbbm.2020.104007_bib7","doi-asserted-by":"crossref","first-page":"287","DOI":"10.1002\/(SICI)1097-0347(199707)19:4<287::AID-HED7>3.0.CO;2-X","article-title":"A comparison of masticatory function in patients with or without reconstruction of the mandible","volume":"19","author":"Curtis","year":"1997","journal-title":"Head Neck"},{"key":"10.1016\/j.jmbbm.2020.104007_bib8","doi-asserted-by":"crossref","first-page":"18","DOI":"10.1186\/s12880-017-0190-z","article-title":"Distal radius plate of CFR-PEEK has minimal effect compared to titanium plates on bone parameters in high-resolution peripheral quantitative computed tomography: a pilot study","volume":"17","author":"de Jong","year":"2017","journal-title":"BMC Med. Imag."},{"key":"10.1016\/j.jmbbm.2020.104007_bib9","doi-asserted-by":"crossref","first-page":"S34","DOI":"10.1016\/S0020-1383(17)30655-1","article-title":"PEEK radiolucent plate for distal radius fractures: multicentre clinical results at 12 months follow up","volume":"48","author":"Di Maggio","year":"2017","journal-title":"Injury"},{"key":"10.1016\/j.jmbbm.2020.104007_bib10","first-page":"373","article-title":"Technical difficulties in hardware removal in titanium compression plates with locking screws","volume":"95","author":"Ehlinger","year":"2009","journal-title":"J. Orthop. Traumatol.: Surg. Res."},{"key":"10.1016\/j.jmbbm.2020.104007_bib11","doi-asserted-by":"crossref","first-page":"1463","DOI":"10.1007\/s00270-018-1987-z","article-title":"New implant-based technologies in the spine","volume":"41","author":"Filippiadis","year":"2018","journal-title":"Cardiovasc. Intervent. Radiol."},{"key":"10.1016\/j.jmbbm.2020.104007_bib12","doi-asserted-by":"crossref","first-page":"203","DOI":"10.1016\/j.clinbiomech.2008.11.002","article-title":"Relative stability of conventional and locked plating fixation in a model of the osteoporotic femoral diaphysis","volume":"24","author":"Fitzpatrick","year":"2009","journal-title":"Clin. Biomech. (Bristol, Avon)"},{"key":"10.1016\/j.jmbbm.2020.104007_bib13","doi-asserted-by":"crossref","first-page":"942","DOI":"10.1016\/j.bjoms.2013.07.004","article-title":"Experimental biomechanical study of the primary stability of different osteosynthesis systems for mandibular reconstruction with an iliac crest graft","volume":"51","author":"Grohmann","year":"2013","journal-title":"Br. J. Oral Maxillofac. Surg."},{"key":"10.1016\/j.jmbbm.2020.104007_bib14","doi-asserted-by":"crossref","first-page":"741","DOI":"10.1016\/j.bjoms.2015.05.022","article-title":"Biomechanical loading test on reconstructed mandibles with fibular, iliac crest or scapula graft: a comparative study","volume":"53","author":"Grohmann","year":"2015","journal-title":"Br. J. Oral Maxillofac. Surg."},{"key":"10.1016\/j.jmbbm.2020.104007_bib15","doi-asserted-by":"crossref","first-page":"21","DOI":"10.2302\/kjm.52.21","article-title":"Principle and stability of locking plates","volume":"52","author":"Gutwald","year":"2003","journal-title":"Keio J. Med."},{"key":"10.1016\/j.jmbbm.2020.104007_bib16","doi-asserted-by":"crossref","first-page":"1249","DOI":"10.1016\/j.injury.2017.03.035","article-title":"Comparison between carbon-peek plate and conventional stainless steal plate in ankle fractures. A prospective study of two years follow up","volume":"48","author":"Guzzini","year":"2017","journal-title":"Injury"},{"key":"10.1016\/j.jmbbm.2020.104007_bib17","doi-asserted-by":"crossref","first-page":"351","DOI":"10.1007\/s00590-016-1891-7","article-title":"Outcomes of proximal humeral fracture fixation with locked CFR-PEEK plating","volume":"27","author":"Katthagen","year":"2017","journal-title":"Eur. J. Orthop. Surg. Traumatol. : Orthop. Traumatol."},{"key":"10.1016\/j.jmbbm.2020.104007_bib18","doi-asserted-by":"crossref","first-page":"1302","DOI":"10.1001\/archotol.133.12.1302","article-title":"Evaluation of hardware-related complications in vascularized bone grafts with locking mandibular reconstruction plate fixation","volume":"133","author":"Knott","year":"2007","journal-title":"Arch. Otolaryngol. Head Neck Surg."},{"key":"10.1016\/j.jmbbm.2020.104007_bib19","doi-asserted-by":"crossref","first-page":"4228","DOI":"10.1007\/s00330-018-5928-7","article-title":"Metal artifacts in patients with large dental implants and bridges: combination of metal artifact reduction algorithms and virtual monoenergetic images provides an approach to handle even strongest artifacts","volume":"29","author":"Laukamp","year":"2019","journal-title":"Eur. Radiol."},{"key":"10.1016\/j.jmbbm.2020.104007_bib20","doi-asserted-by":"crossref","first-page":"37","DOI":"10.1007\/s10006-005-0656-y","article-title":"Computergest\u00fctzte Kaukraftanalyse bei Patienten mit Unterkieferkontinuit\u00e4tsresektionen","volume":"10","author":"Maurer","year":"2006","journal-title":"Mund-, Kiefer- Gesichtschirurgie"},{"key":"10.1016\/j.jmbbm.2020.104007_bib21","doi-asserted-by":"crossref","first-page":"689","DOI":"10.1007\/s00264-012-1487-8","article-title":"Optimal mechanical environment of the healing bone fracture\/osteotomy","volume":"36","author":"Mavcic","year":"2012","journal-title":"Int. Orthop."},{"key":"10.1016\/j.jmbbm.2020.104007_bib22","doi-asserted-by":"crossref","first-page":"123","DOI":"10.1007\/s13246-015-0407-9","article-title":"The relationship between interfragmentary movement and cell differentiation in early fracture healing under locking plate fixation","volume":"39","author":"Miramini","year":"2016","journal-title":"Australas. Phys. Eng. Sci. Med."},{"key":"10.1016\/j.jmbbm.2020.104007_bib23","doi-asserted-by":"crossref","first-page":"877","DOI":"10.1016\/j.otsr.2018.05.002","article-title":"Biomechanical comparison between stainless steel, titanium and carbon-fiber reinforced polyetheretherketone volar locking plates for distal radius fractures","volume":"104","author":"Mugnai","year":"2018","journal-title":"Orthop. Traumatol. Surg. Res."},{"key":"10.1016\/j.jmbbm.2020.104007_bib24","doi-asserted-by":"crossref","first-page":"512","DOI":"10.1563\/aaid-joi-D-16-00072","article-title":"Bioactivity and osseointegration of PEEK are inferior to those of titanium: a systematic review","volume":"42","author":"Najeeb","year":"2016","journal-title":"J. Oral Implantol."},{"key":"10.1016\/j.jmbbm.2020.104007_bib25","doi-asserted-by":"crossref","first-page":"2182","DOI":"10.1016\/j.jcms.2018.09.030","article-title":"Feasibility of carbon-fiber-reinforced polymer fixation plates for treatment of atrophic mandibular fracture: a finite element method","volume":"46","author":"Nurettin","year":"2018","journal-title":"J. Cranio-Maxillo-Facial Surg.: Off. Publ. Eur. Assoc. Cranio-Maxillo-Facial Surg."},{"key":"10.1016\/j.jmbbm.2020.104007_bib26","doi-asserted-by":"crossref","first-page":"1093","DOI":"10.1302\/0301-620X.84B8.0841093","article-title":"Evolution of the internal fixation of long bone fractures. The scientific basis of biological internal fixation: choosing a new balance between stability and biology","volume":"84","author":"Perren","year":"2002","journal-title":"J. Bone Joint Surg. Br."},{"issue":"Suppl. 3","key":"10.1016\/j.jmbbm.2020.104007_bib27","doi-asserted-by":"crossref","first-page":"S24","DOI":"10.1016\/S0020-1383(17)30653-8","article-title":"Comparison between Carbon-Peek volar locking plates and titanium volar locking plates in the treatment of distal radius fractures","volume":"48","author":"Perugia","year":"2017","journal-title":"Injury"},{"key":"10.1016\/j.jmbbm.2020.104007_bib28","doi-asserted-by":"crossref","first-page":"1417","DOI":"10.1097\/PRS.0000000000006261","article-title":"Computer-assisted versus conventional freehand mandibular reconstruction with fibula free flap: a systematic review and meta-analysis","volume":"144","author":"Powcharoen","year":"2019","journal-title":"Plast. Reconstr. Surg."},{"key":"10.1016\/j.jmbbm.2020.104007_bib29","doi-asserted-by":"crossref","first-page":"676","DOI":"10.1016\/j.ijom.2017.11.013","article-title":"Free flap surgery in Europe: an interdisciplinary survey","volume":"47","author":"Rendenbach","year":"2018","journal-title":"Int. J. Oral Maxillofac. Surg."},{"key":"10.1016\/j.jmbbm.2020.104007_bib30","doi-asserted-by":"crossref","first-page":"20170361","DOI":"10.1259\/dmfr.20170361","article-title":"Evaluation and reduction of magnetic resonance imaging artefacts induced by distinct plates for osseous fixation: an in vitro study @ 3 T","volume":"47","author":"Rendenbach","year":"2018","journal-title":"Dentomaxillofacial Radiol."},{"key":"10.1016\/j.jmbbm.2020.104007_bib31","doi-asserted-by":"crossref","first-page":"1878","DOI":"10.1016\/j.jcms.2017.08.024","article-title":"CAD-CAM plates versus conventional fixation plates for primary mandibular reconstruction: a biomechanical in vitro analysis","volume":"45","author":"Rendenbach","year":"2017","journal-title":"J. Cranio-Maxillo-Fac. Surg."},{"key":"10.1016\/j.jmbbm.2020.104007_bib32","doi-asserted-by":"crossref","first-page":"1156","DOI":"10.1016\/j.ijom.2019.01.029","article-title":"Complication rates and clinical outcomes of osseous free flaps: a retrospective comparison of CAD\/CAM versus conventional fixation in 128 patients","volume":"48","author":"Rendenbach","year":"2019","journal-title":"Int. J. Oral Maxillofac. Surg."},{"key":"10.1016\/j.jmbbm.2020.104007_bib33","doi-asserted-by":"crossref","first-page":"212","DOI":"10.1016\/j.jmbbm.2018.12.014","article-title":"Patient specific glass fiber reinforced composite versus titanium plate: a comparative biomechanical analysis under cyclic dynamic loading","volume":"91","author":"Rendenbach","year":"2019","journal-title":"J. Mech. Behav. Biomed. Mater."},{"key":"10.1016\/j.jmbbm.2020.104007_bib34","doi-asserted-by":"crossref","first-page":"1733","DOI":"10.1097\/PRS.0b013e31818a9ac5","article-title":"Comparison of miniplates and reconstruction plates in fibular flap reconstruction of the mandible","volume":"122","author":"Robey","year":"2008","journal-title":"Plast. Reconstr. Surg."},{"key":"10.1016\/j.jmbbm.2020.104007_bib35","doi-asserted-by":"crossref","first-page":"1282","DOI":"10.1016\/j.jse.2014.12.028","article-title":"Treatment of proximal humerus fractures with a CFR-PEEK plate: 2-year results of a prospective study and comparison to fixation with a conventional locking plate","volume":"24","author":"Schliemann","year":"2015","journal-title":"J. Shoulder Elbow Surg."},{"key":"10.1016\/j.jmbbm.2020.104007_bib36","doi-asserted-by":"crossref","first-page":"63","DOI":"10.1007\/s00402-016-2620-8","article-title":"PEEK versus titanium locking plates for proximal humerus fracture fixation: a comparative biomechanical study in two- and three-part fractures","volume":"137","author":"Schliemann","year":"2017","journal-title":"Arch. Orthop. Trauma Surg."},{"key":"10.1016\/j.jmbbm.2020.104007_bib37","doi-asserted-by":"crossref","first-page":"456","DOI":"10.1002\/hed.10343","article-title":"Comparison of miniplates and reconstruction plates in mandibular reconstruction","volume":"26","author":"Shaw","year":"2004","journal-title":"Head Neck"},{"key":"10.1016\/j.jmbbm.2020.104007_bib38","doi-asserted-by":"crossref","first-page":"791","DOI":"10.1016\/0278-2391(95)90335-6","article-title":"Fracture line stability as a function of the internal fixation system: an in vitro comparison using a mandibular angle fracture model","volume":"53","author":"Shetty","year":"1995","journal-title":"J. Oral Maxillofac. Surg."},{"key":"10.1016\/j.jmbbm.2020.104007_bib39","doi-asserted-by":"crossref","first-page":"56","DOI":"10.1016\/S0278-2391(00)80017-8","article-title":"An in vitro study of the effect of bony buttressing on fixation strength of a fractured atrophic edentulous mandible model","volume":"58","author":"Sikes","year":"2000","journal-title":"J. Oral Maxillofac. Surg."},{"key":"10.1016\/j.jmbbm.2020.104007_bib40","doi-asserted-by":"crossref","first-page":"468","DOI":"10.1016\/S0278-2391(98)90715-7","article-title":"Comparison of fixation strengths of locking head and conventional screws, in fracture and reconstruction models","volume":"56","author":"Sikes","year":"1998","journal-title":"J. Oral Maxillofac. Surg."},{"key":"10.1016\/j.jmbbm.2020.104007_bib41","article-title":"Biomechanical comparison of polylactide-based versus titanium miniplates in mandible reconstruction in vitro","author":"Steffen","year":"2019","journal-title":"J. Stomatol. Oral Maxillofac. Surg."},{"key":"10.1016\/j.jmbbm.2020.104007_bib42","doi-asserted-by":"crossref","first-page":"221","DOI":"10.1016\/j.jmbbm.2012.09.013","article-title":"Carbon fiber reinforced PEEK Optima--a composite material biomechanical properties and wear\/debris characteristics of CF-PEEK composites for orthopedic trauma implants","volume":"17","author":"Steinberg","year":"2013","journal-title":"J. Mech. Behav. Biomed. Mater."},{"key":"10.1016\/j.jmbbm.2020.104007_bib43","doi-asserted-by":"crossref","first-page":"1291","DOI":"10.1007\/s00784-013-1105-1","article-title":"Locking versus nonlocking plates in mandibular reconstruction with fibular graft--a biomechanical ex vivo study","volume":"18","author":"Trainotti","year":"2014","journal-title":"Clin. Oral Invest."},{"key":"10.1016\/j.jmbbm.2020.104007_bib44","doi-asserted-by":"crossref","first-page":"2451","DOI":"10.1007\/s00264-013-2109-9","article-title":"Locking versus non-locking neutralization plates for treatment of lateral malleolar fractures: a randomized controlled trial","volume":"37","author":"Tsukada","year":"2013","journal-title":"Int. Orthop."},{"key":"10.1016\/j.jmbbm.2020.104007_bib45","doi-asserted-by":"crossref","first-page":"2035","DOI":"10.1007\/s11548-015-1193-2","article-title":"Multicenter study on the use of patient-specific CAD\/CAM reconstruction plates for mandibular reconstruction","volume":"10","author":"Wilde","year":"2015","journal-title":"Int. J. Comput. Assist. Radiol. Surg."},{"key":"10.1016\/j.jmbbm.2020.104007_bib46","doi-asserted-by":"crossref","first-page":"91","DOI":"10.1016\/j.oraloncology.2018.06.008","article-title":"Risk of plate removal in free flap reconstruction of the mandible","volume":"83","author":"Wood","year":"2018","journal-title":"Oral Oncol."}],"container-title":["Journal of the Mechanical Behavior of Biomedical Materials"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1751616120305580?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1751616120305580?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,28]],"date-time":"2025-10-28T22:35:04Z","timestamp":1761690904000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1751616120305580"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,11]]},"references-count":46,"alternative-id":["S1751616120305580"],"URL":"https:\/\/doi.org\/10.1016\/j.jmbbm.2020.104007","relation":{},"ISSN":["1751-6161"],"issn-type":[{"value":"1751-6161","type":"print"}],"subject":[],"published":{"date-parts":[[2020,11]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Biomechanical comparison of titanium miniplates versus a variety of CAD\/CAM plates in mandibular reconstruction","name":"articletitle","label":"Article Title"},{"value":"Journal of the Mechanical Behavior of Biomedical Materials","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jmbbm.2020.104007","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2020 Elsevier Ltd. All rights reserved.","name":"copyright","label":"Copyright"}],"article-number":"104007"}}