{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,9]],"date-time":"2026-10-09T17:55:36Z","timestamp":1791568536346,"version":"4.3.4"},"reference-count":47,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2021,1,1]],"date-time":"2021-01-01T00:00:00Z","timestamp":1609459200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2021,1,1]],"date-time":"2021-01-01T00:00:00Z","timestamp":1609459200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of the Mechanical Behavior of Biomedical Materials"],"published-print":{"date-parts":[[2021,1]]},"DOI":"10.1016\/j.jmbbm.2020.104145","type":"journal-article","created":{"date-parts":[[2020,10,17]],"date-time":"2020-10-17T02:20:31Z","timestamp":1602901231000},"page":"104145","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":87,"special_numbering":"C","title":["Surface modification for osseointegration of Ti6Al4V ELI using powder mixed sinking EDM"],"prefix":"10.1016","volume":"113","author":[{"given":"Mohammad Pervez","family":"Mughal","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4139-2082","authenticated-orcid":false,"given":"Muhammad Umar","family":"Farooq","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jabir","family":"Mumtaz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8351-1871","authenticated-orcid":false,"given":"Mozammel","family":"Mia","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Madiha","family":"Shareef","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mahnoor","family":"Javed","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Muhammad","family":"Jamil","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4926-2189","authenticated-orcid":false,"given":"Catalin I.","family":"Pruncu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.jmbbm.2020.104145_bib1","doi-asserted-by":"crossref","first-page":"1319","DOI":"10.1007\/s00170-018-1574-0","article-title":"Electric discharge machining of titanium and its alloys: review","volume":"96","author":"Abu Qudeiri","year":"2018","journal-title":"Int. J. Adv. Manuf. Technol."},{"key":"10.1016\/j.jmbbm.2020.104145_bib2","series-title":"The Design and Manufacture of Medical Devices","first-page":"1","article-title":"Characteristics and applications of titanium oxide as a biomaterial for medical implants","author":"Ahmed","year":"2012"},{"key":"10.1016\/j.jmbbm.2020.104145_bib3","doi-asserted-by":"crossref","first-page":"167","DOI":"10.1007\/s00170-017-0103-x","article-title":"Optimization of process parameters in micro-EDM of Ti-6Al-4V based on full factorial design","volume":"92","author":"Alavi","year":"2017","journal-title":"Int. J. Adv. Manuf. Technol."},{"key":"10.1016\/j.jmbbm.2020.104145_bib4","author":"Azom Materials"},{"key":"10.1016\/j.jmbbm.2020.104145_bib5","doi-asserted-by":"crossref","first-page":"136","DOI":"10.1016\/j.colsurfb.2006.02.016","article-title":"Does the nanometre scale topography of titanium influence protein adsorption and cell proliferation?","volume":"49","author":"Cai","year":"2006","journal-title":"Colloids Surf. B Biointerfaces"},{"key":"10.1016\/j.jmbbm.2020.104145_bib6","doi-asserted-by":"crossref","first-page":"413","DOI":"10.1016\/j.jallcom.2007.02.055","article-title":"Effect of electro-discharging on formation of biocompatible layer on implant surface","volume":"456","author":"Chen","year":"2008","journal-title":"J. Alloys Compd."},{"key":"10.1016\/j.jmbbm.2020.104145_bib7","doi-asserted-by":"crossref","first-page":"1035","DOI":"10.1243\/09544054JEM320","article-title":"An experimental investigation on the effect of powder mixed dielectric on machining performance in electric discharge machining","volume":"220","author":"\u00c7ogun","year":"2006","journal-title":"Proc. IME B J. Eng. Manufact."},{"key":"10.1016\/j.jmbbm.2020.104145_bib8","doi-asserted-by":"crossref","first-page":"364","DOI":"10.1016\/j.measurement.2014.11.025","article-title":"Study of surface integrity and dimensional accuracy in EDM using Fuzzy TOPSIS and sensitivity analysis","volume":"63","author":"Dewangan","year":"2015","journal-title":"Measurement"},{"key":"10.1016\/j.jmbbm.2020.104145_bib9","series-title":"Titanium and its Alloy in Biomedical Engineering. Sci. And Tech","first-page":"1","author":"Freese","year":"2001"},{"key":"10.1016\/j.jmbbm.2020.104145_bib10","doi-asserted-by":"crossref","first-page":"2093","DOI":"10.1007\/s00170-017-1399-2","article-title":"Experimental investigation of the effects of tool initial surface roughness on the electrical discharge machining (EDM) performance","volume":"95","author":"Hadad","year":"2018","journal-title":"Int. J. Adv. Manuf. Technol."},{"key":"10.1016\/j.jmbbm.2020.104145_bib11","doi-asserted-by":"crossref","first-page":"9384","DOI":"10.1039\/C7TB02444D","article-title":"Stainless steel with tailored porosity using canister-free hot isostatic pressing for improved osseointegration implants","volume":"5","author":"Hassanin","year":"2017","journal-title":"J. Mater. Chem. B"},{"key":"10.1016\/j.jmbbm.2020.104145_bib12","doi-asserted-by":"crossref","first-page":"1575","DOI":"10.1007\/s00170-018-2697-z","article-title":"Evaluation of surface integrity after high energy machining with EDM, laser beam machining and abrasive water jet machining of alloy 718","volume":"100","author":"Holmberg","year":"2019","journal-title":"Int. J. Adv. Manuf. Technol."},{"key":"10.1016\/j.jmbbm.2020.104145_bib13","doi-asserted-by":"crossref","first-page":"3517","DOI":"10.1007\/s11665-019-04120-0","article-title":"A study on the surface composition and migration of materials and their effect on surface microhardness during micro-EDM of Ti-6Al-4V","volume":"28","author":"Jahan","year":"2019","journal-title":"J. Mater. Eng. Perform."},{"key":"10.1016\/j.jmbbm.2020.104145_bib14","first-page":"524","article-title":"Effect of dielectric fluid with surfactant and graphite powder on Electrical Discharge Machining of titanium alloy using Taguchi method","volume":"18","author":"Kolli","year":"2015","journal-title":"Eng Sci Tech, Int J"},{"key":"10.1016\/j.jmbbm.2020.104145_bib15","doi-asserted-by":"crossref","first-page":"1957","DOI":"10.1016\/j.mspro.2014.07.528","article-title":"Effect of boron carbide powder mixed into dielectric fluid on electrical discharge machining of titanium alloy","volume":"5","author":"Kolli","year":"2014","journal-title":"Procedia Mater Sci"},{"key":"10.1016\/j.jmbbm.2020.104145_bib16","doi-asserted-by":"crossref","first-page":"1429","DOI":"10.1080\/10426914.2017.1415439","article-title":"Multiobjective optimization and analysis of copper\u2013titanium diboride electrode in EDM of monel 400TM alloy","volume":"33","author":"Kumar","year":"2018","journal-title":"Mater. Manuf. Process."},{"key":"10.1016\/j.jmbbm.2020.104145_bib17","doi-asserted-by":"crossref","first-page":"3675","DOI":"10.1016\/j.jmatprotec.2008.09.032","article-title":"Surface modification by electrical discharge machining: a review","volume":"209","author":"Kumar","year":"2009","journal-title":"J. Mater. Process. Technol."},{"key":"10.1016\/j.jmbbm.2020.104145_bib18","doi-asserted-by":"crossref","first-page":"349","DOI":"10.1111\/j.1600-0501.2011.02172.x","article-title":"Early osseointegration to hydrophilic and hydrophobic implant surfaces in humans: early osseointegration on implant surfaces","volume":"22","author":"Lang","year":"2011","journal-title":"Clin. Oral Implants Res."},{"key":"10.1016\/j.jmbbm.2020.104145_bib19","doi-asserted-by":"crossref","first-page":"92","DOI":"10.1016\/j.jecm.2013.04.002","article-title":"Nanoporous biocompatible layer on Ti-6Al-4V alloys enhanced osteoblast-like cell response","volume":"5","author":"Lee","year":"2013","journal-title":"J. Exp. Clin. Med."},{"key":"10.1016\/j.jmbbm.2020.104145_bib20","doi-asserted-by":"crossref","first-page":"1743","DOI":"10.1007\/s00170-017-1315-9","article-title":"Study of the EDM performance to produce a stable process and surface modification","volume":"95","author":"Liang","year":"2018","journal-title":"Int. J. Adv. Manuf. Technol."},{"key":"10.1016\/j.jmbbm.2020.104145_bib21","doi-asserted-by":"crossref","first-page":"274","DOI":"10.1504\/IJMMM.2018.10014654","article-title":"Micro-EDM induced surface modification of titanium alloy for biocompatibility","volume":"20","author":"Mahbub","year":"2018","journal-title":"IJMMM"},{"key":"10.1016\/j.jmbbm.2020.104145_bib22","series-title":"IEEE SoutheastCon 2008","first-page":"599","article-title":"Improvements in performance of EDM-A review","author":"Malhotra","year":"2008"},{"key":"10.1016\/j.jmbbm.2020.104145_bib23","doi-asserted-by":"crossref","first-page":"255","DOI":"10.1111\/j.1551-2916.2010.04038.x","article-title":"Zn-releasing FHA coating and its enhanced osseointegration ability: Zn-releasing FHA coating and enhanced osseointegration ability","volume":"94","author":"Miao","year":"2011","journal-title":"J. Am. Ceram. Soc."},{"key":"10.1016\/j.jmbbm.2020.104145_bib24","first-page":"536","article-title":"Machinability behaviour of biocompatible Ti-6Al-4V ELI titanium alloy under flood cooling environment","volume":"23","author":"Mishra","year":"2019","journal-title":"Mater. Today: Proceedings"},{"key":"10.1016\/j.jmbbm.2020.104145_bib25","doi-asserted-by":"crossref","first-page":"231","DOI":"10.1016\/S0921-5093(97)00806-X","article-title":"Mechanical properties of biomedical titanium alloys","volume":"243","author":"Niinomi","year":"1998","journal-title":"Mater. Sci. Eng., A"},{"key":"10.1016\/j.jmbbm.2020.104145_bib26","doi-asserted-by":"crossref","first-page":"744","DOI":"10.1016\/j.jmapro.2018.01.002","article-title":"Particle migration and surface modification on Ti6Al4V in SiC powder mixed electrical discharge machining","volume":"31","author":"\u00d6p\u00f6z","year":"2018","journal-title":"J. Manuf. Process."},{"key":"10.1016\/j.jmbbm.2020.104145_bib27","doi-asserted-by":"crossref","first-page":"684","DOI":"10.1111\/j.1600-0501.2009.01714.x","article-title":"Enhanced osteoconductivity of micro-structured titanium implants (XiVE S CELLplus) by addition of surface calcium chemistry: a histomorphometric study in the rabbit femur","volume":"20","author":"Park","year":"2009","journal-title":"Clin. Oral Implants Res."},{"key":"10.1016\/j.jmbbm.2020.104145_bib28","doi-asserted-by":"crossref","first-page":"625","DOI":"10.1016\/j.jallcom.2009.11.197","article-title":"Effect of electrical-discharging on formation of nanoporous biocompatible layer on titanium","volume":"492","author":"Peng","year":"2010","journal-title":"J. Alloys Compd."},{"key":"10.1016\/j.jmbbm.2020.104145_bib29","doi-asserted-by":"crossref","first-page":"274","DOI":"10.1080\/10426914.2016.1198018","article-title":"Experimental investigations in powder mixed electric discharge machining of Ti\u201335Nb\u20137Ta\u20135Zr\u03b2-titanium alloy","volume":"32","author":"Prakash","year":"2017","journal-title":"Mater. Manuf. Process."},{"key":"10.1016\/j.jmbbm.2020.104145_bib30","doi-asserted-by":"crossref","first-page":"3622","DOI":"10.1007\/s11665-015-1619-6","article-title":"Processing and characterization of novel biomimetic nanoporous bioceramic surface on \u03b2-Ti implant by powder mixed electric discharge machining","volume":"24","author":"Prakash","year":"2015","journal-title":"J. Mater. Eng. Perform."},{"key":"10.1016\/j.jmbbm.2020.104145_bib31","doi-asserted-by":"crossref","first-page":"330","DOI":"10.1007\/s40430-018-1257-7","article-title":"Effect of using SiC powder-added dielectric media during electro-discharge machining of Inconel 718 superalloys","volume":"40","author":"Sahu","year":"2018","journal-title":"J. Braz. Soc. Mech. Sci. Eng."},{"key":"10.1016\/j.jmbbm.2020.104145_bib32","doi-asserted-by":"crossref","first-page":"2255","DOI":"10.1007\/s00170-018-1973-2","article-title":"Machining of biocompatible materials: a review","volume":"97","author":"Saptaji","year":"2018","journal-title":"Int. J. Adv. Manuf. Technol."},{"key":"10.1016\/j.jmbbm.2020.104145_bib33","doi-asserted-by":"crossref","first-page":"212","DOI":"10.1016\/j.jmapro.2016.11.016","article-title":"Investigation of carbon nanotube added dielectric on the surface characteristics and machining performance of Ti\u20136Al\u20134V alloy in EDM process","volume":"25","author":"Shabgard","year":"2017","journal-title":"J. Manuf. Process."},{"key":"10.1016\/j.jmbbm.2020.104145_bib34","doi-asserted-by":"crossref","first-page":"772","DOI":"10.1111\/j.1600-0501.2010.01912.x","article-title":"Long-term implant survival and success: a 10\u201316-year follow-up of non-submerged dental implants","volume":"21","author":"Simonis","year":"2010","journal-title":"Clin. Oral Implants Res."},{"key":"10.1016\/j.jmbbm.2020.104145_bib35","first-page":"182","article-title":"Effect of silicon powder mixed EDM on surface roughness of Al6063 aluminium alloy","volume":"2","author":"Singh","year":"2015","journal-title":"Int. J. Innovat. Res. Sci. Technol."},{"key":"10.1016\/j.jmbbm.2020.104145_bib36","series-title":"IOP Conference Series: Materials Science and Engineering","article-title":"Effect of dielectric on electrical discharge machining: a review","author":"Singh","year":"2018"},{"key":"10.1016\/j.jmbbm.2020.104145_bib37","doi-asserted-by":"crossref","first-page":"357","DOI":"10.1016\/j.dental.2007.06.003","article-title":"Zirconium oxide coating improves implant osseointegration in vivo","volume":"24","author":"Sollazzo","year":"2008","journal-title":"Dent. Mater."},{"key":"10.1016\/j.jmbbm.2020.104145_bib38","doi-asserted-by":"crossref","first-page":"467","DOI":"10.1080\/10426910903365760","article-title":"Optimization of material removal rate in micro-EDM using artificial neural network and genetic algorithms","volume":"25","author":"Somashekhar","year":"2010","journal-title":"Mater. Manuf. Process."},{"key":"10.1016\/j.jmbbm.2020.104145_bib39","series-title":"Emerging Nanotechnologies in Dentistry","first-page":"99","article-title":"Titanium surface modification techniques for dental implants\u2014from microscale to nanoscale","author":"Subramani","year":"2018"},{"key":"10.1016\/j.jmbbm.2020.104145_bib40","doi-asserted-by":"crossref","first-page":"534","DOI":"10.18517\/ijaseit.6.4.902","article-title":"Optimization of electrode material for EDM die-sinking of titanium alloy grade 5 - Ti6Al4V","volume":"6","author":"Suresh","year":"2016","journal-title":"Int. J. Adv. Sci. Eng. Inf. Technol."},{"key":"10.1016\/j.jmbbm.2020.104145_bib41","doi-asserted-by":"crossref","first-page":"861","DOI":"10.1007\/s00170-017-1231-z","article-title":"Investigation on the effect of dielectrics during micro-electro-discharge machining of Ti-6Al-4V","volume":"95","author":"Tiwary","year":"2018","journal-title":"Int. J. Adv. Manuf. Technol."},{"key":"10.1016\/j.jmbbm.2020.104145_bib42","doi-asserted-by":"crossref","DOI":"10.3390\/ma13071549","article-title":"On the investigation of surface integrity of Ti6Al4V ELI using Si-mixed electric discharge machining","volume":"13","author":"Umar Farooq","year":"2020","journal-title":"Materials"},{"key":"10.1016\/j.jmbbm.2020.104145_bib43","series-title":"Advances in Metallic Biomaterials","first-page":"181","article-title":"Functionally graded metallic biomaterials","author":"Watanabe","year":"2015"},{"key":"10.1016\/j.jmbbm.2020.104145_bib44","doi-asserted-by":"crossref","first-page":"374","DOI":"10.1097\/ID.0b013e31829a170a","article-title":"Effect of electrical discharging on formation of nanoporous biocompatible layer on Ti-6Al-4V alloys","volume":"22","author":"Yang","year":"2013","journal-title":"Implant Dent."},{"key":"10.1016\/j.jmbbm.2020.104145_bib45","doi-asserted-by":"crossref","first-page":"2111","DOI":"10.1007\/s00170-017-0675-5","article-title":"Experimental investigation of fabricating diamond abrasive layers by EDM","volume":"93","author":"Ying","year":"2017","journal-title":"Int. J. Adv. Manuf. Technol."},{"key":"10.1016\/j.jmbbm.2020.104145_bib46","doi-asserted-by":"crossref","DOI":"10.3390\/ijms20051127","article-title":"Optimized surface characteristics and enhanced in vivo osseointegration of alkali-treated titanium with nanonetwork structures","volume":"20","author":"Zeng","year":"2019","journal-title":"Int. J. Mol. Sci."},{"key":"10.1016\/j.jmbbm.2020.104145_bib47","doi-asserted-by":"crossref","first-page":"43","DOI":"10.1016\/j.jmatprotec.2016.01.027","article-title":"Influence of porous structure on the machining performance of micro EDM","volume":"232","author":"Zou","year":"2016","journal-title":"J. Mater. Process. Technol."}],"container-title":["Journal of the Mechanical Behavior of Biomedical Materials"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1751616120306913?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1751616120306913?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,28]],"date-time":"2025-10-28T22:40:16Z","timestamp":1761691216000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1751616120306913"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,1]]},"references-count":47,"alternative-id":["S1751616120306913"],"URL":"https:\/\/doi.org\/10.1016\/j.jmbbm.2020.104145","relation":{},"ISSN":["1751-6161"],"issn-type":[{"value":"1751-6161","type":"print"}],"subject":[],"published":{"date-parts":[[2021,1]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Surface modification for osseointegration of Ti6Al4V ELI using powder mixed sinking EDM","name":"articletitle","label":"Article Title"},{"value":"Journal of the Mechanical Behavior of Biomedical Materials","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jmbbm.2020.104145","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2020 Elsevier Ltd. All rights reserved.","name":"copyright","label":"Copyright"}],"article-number":"104145"}}