{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,25]],"date-time":"2026-10-25T19:33:11Z","timestamp":1792956791077,"version":"4.5.0"},"reference-count":61,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2022,3,1]],"date-time":"2022-03-01T00:00:00Z","timestamp":1646092800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2022,3,1]],"date-time":"2022-03-01T00:00:00Z","timestamp":1646092800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2022,1,4]],"date-time":"2022-01-04T00:00:00Z","timestamp":1641254400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100001867","name":"Malta Council for Science and Technology","doi-asserted-by":"publisher","award":["R&I-2015-023T"],"award-info":[{"award-number":["R&I-2015-023T"]}],"id":[{"id":"10.13039\/501100001867","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of the Mechanical Behavior of Biomedical Materials"],"published-print":{"date-parts":[[2022,3]]},"DOI":"10.1016\/j.jmbbm.2021.105072","type":"journal-article","created":{"date-parts":[[2022,1,3]],"date-time":"2022-01-03T18:51:04Z","timestamp":1641235864000},"page":"105072","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":26,"special_numbering":"C","title":["A novel hip joint prosthesis with uni-directional articulations for reduced wear"],"prefix":"10.1016","volume":"127","author":[{"given":"Donald","family":"Dalli","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6517-7331","authenticated-orcid":false,"given":"Joseph","family":"Buhagiar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4234-0754","authenticated-orcid":false,"given":"Pierluigi","family":"Mollicone","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pierre","family":"Schembri Wismayer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.jmbbm.2021.105072_bib2","first-page":"71","article-title":"Finite element study of acetabular cup contact region for Total Hip Replacement (THR)","volume":"2","author":"Abd Manap","year":"2017","journal-title":"J. Mech. Eng. SI"},{"issue":"8","key":"10.1016\/j.jmbbm.2021.105072_bib3","doi-asserted-by":"crossref","first-page":"1282","DOI":"10.3390\/ma11081282","article-title":"Development of a novel in silico model to investigate the influence of radial clearance on the acetabular cup contact pressure in hip implants","volume":"11","author":"Affatato","year":"2018","journal-title":"Materials (Basel)"},{"key":"10.1016\/j.jmbbm.2021.105072_bib4","first-page":"31","article-title":"An advanced thermomechanical constitutive model for UHMWPE","volume":"2","author":"Bergstr\u00f6m","year":"2010","journal-title":"Int. J. Struct. Chang. Solids."},{"key":"10.1016\/j.jmbbm.2021.105072_bib6","first-page":"838","article-title":"Morphology of wear particles of heavily cross linked polyethylene","volume":"24","author":"Bhambri","year":"1999","journal-title":"Trans Orthop Res Soc"},{"key":"10.1016\/j.jmbbm.2021.105072_bib8","doi-asserted-by":"crossref","first-page":"369","DOI":"10.1177\/1071100714558507","article-title":"Influence of crosslinking on the wear performance of polyethylene within total ankle arthroplasty","volume":"36","author":"Bischoff","year":"2015","journal-title":"Foot Ankle Int."},{"key":"10.1016\/j.jmbbm.2021.105072_bib9","doi-asserted-by":"crossref","first-page":"541","DOI":"10.1302\/2058-5241.4.180045","article-title":"Dual mobility total hip arthroplasty: should everyone get one?","volume":"4","author":"Blakeney","year":"2019","journal-title":"EFORT Open Rev"},{"key":"10.1016\/j.jmbbm.2021.105072_bib69","doi-asserted-by":"crossref","first-page":"511","DOI":"10.1007\/s00264-011-1289-4","article-title":"Primary total hip arthroplasty with dual mobility socket to prevent dislocation: a 22-year follow-up of 240 hips","volume":"36","author":"Boyer","year":"2012","journal-title":"Int. Orthop (SICOT)"},{"key":"10.1016\/j.jmbbm.2021.105072_bib11","doi-asserted-by":"crossref","first-page":"128","DOI":"10.2106\/JBJS.H.00155","article-title":"The epidemiology of revision total hip arthroplasty in the United States","volume":"91","author":"Bozic","year":"2009","journal-title":"J. Bone Jt. Surgery-American"},{"key":"10.1016\/j.jmbbm.2021.105072_bib12","doi-asserted-by":"crossref","first-page":"68","DOI":"10.1097\/01.blo.0000150124.34906.34","article-title":"Fatigue crack propagation resistance of highly crosslinked polyethylene","author":"Bradford","year":"2004","journal-title":"Clin. Orthop. Relat. Res."},{"key":"10.1016\/j.jmbbm.2021.105072_bib13","first-page":"1999","article-title":"The effect of load plus motion versus load alone on fluid inbibition into UHMWPE","volume":"22","author":"Bragdon","year":"1999","journal-title":"Trans. Soc. Biomater."},{"key":"10.1016\/j.jmbbm.2021.105072_bib14","doi-asserted-by":"crossref","first-page":"1129","DOI":"10.1016\/S0140-6736(61)92063-3","article-title":"Arthroplasty of the hip: a new operation","volume":"277","author":"Charnley","year":"1961","journal-title":"Lancet"},{"key":"10.1016\/j.jmbbm.2021.105072_bib66","series-title":"UHMWPE biomaterials for joint implants: Structures, properties and clinical performace","first-page":"1","article-title":"Clinical applications of UHMWPE joint implants","author":"Chen","year":"2019"},{"key":"10.1016\/j.jmbbm.2021.105072_bib15","doi-asserted-by":"crossref","first-page":"21","DOI":"10.1002\/9781118831328.ch2","article-title":"Ultra high molecular weight polyethylene (UHMWPE) for orthopaedic devices: structure\/property relationships","volume":"1","author":"Collins","year":"2015","journal-title":"Polyethylene-Based Blends, Compos. Nanocomposites."},{"key":"10.1016\/j.jmbbm.2021.105072_bib16","doi-asserted-by":"crossref","first-page":"180","DOI":"10.5312\/wjo.v5.i3.180","article-title":"Dual mobility cups in total hip arthroplasty","volume":"5","author":"De Martino","year":"2014","journal-title":"World J. Orthoped."},{"key":"10.1016\/j.jmbbm.2021.105072_bib17","doi-asserted-by":"crossref","first-page":"2495","DOI":"10.1007\/s00264-017-3523-1","article-title":"Retrieval evidence of impingement at the third articulation in contemporary dual mobility cups for total hip arthroplasty","volume":"41","author":"Di Laura","year":"2017","journal-title":"Int. Orthop."},{"key":"10.1016\/j.jmbbm.2021.105072_bib18","doi-asserted-by":"crossref","first-page":"616","DOI":"10.1016\/S0883-5403(99)90086-4","article-title":"Plasticity-induced damage layer is a precursor to wear in radiation-cross-linked UHMWPE acetabular components for total hip replacement","volume":"14","author":"Edidin","year":"1999","journal-title":"J. Arthroplasty"},{"key":"10.1016\/j.jmbbm.2021.105072_bib19","doi-asserted-by":"crossref","first-page":"647","DOI":"10.1016\/S0140-6736(18)31665-9","article-title":"How long does a hip replacement last? A systematic review and meta-analysis of case series and national registry reports with more than 15 years of follow-up","volume":"393","author":"Evans","year":"2019","journal-title":"Lancet"},{"key":"10.1016\/j.jmbbm.2021.105072_bib20","doi-asserted-by":"crossref","first-page":"73","DOI":"10.1243\/PIME_PROC_1991_205_271_02","article-title":"Tribology of total artificial joints","volume":"205","author":"Fisher","year":"1991","journal-title":"Proc. Inst. Mech. Eng. Part H J. Eng. Med."},{"key":"10.1016\/j.jmbbm.2021.105072_bib21","series-title":"Friction, Lubrication and Wear of Total Joint Replacements (Doctoral dissertation)","author":"Flanagan","year":"2010"},{"key":"10.1016\/j.jmbbm.2021.105072_bib23","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1007\/s11249-009-9563-y","article-title":"Molecular deformation mechanisms in UHMWPE during tribological loading in artificial joints","volume":"38","author":"Galetz","year":"2010","journal-title":"Tribol. Lett."},{"key":"10.1016\/j.jmbbm.2021.105072_bib24","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1243\/09544119JEIM99","article-title":"Wear and biological activity of highly crosslinked polyethylene in the hip under low serum protein concentrations","volume":"221","author":"Galvin","year":"2007","journal-title":"Proc. Inst. Mech. Eng. Part H J. Eng. Med."},{"key":"10.1016\/j.jmbbm.2021.105072_bib25","series-title":"U.S. Patent No. US20040193282A1","article-title":"Reduced wear orthopaedic implant apparatus and method","author":"Hanes","year":"2004"},{"key":"10.1016\/j.jmbbm.2021.105072_bib26","doi-asserted-by":"crossref","first-page":"2325","DOI":"10.2106\/00004623-200312000-00009","article-title":"Comparison of the wear rates of twenty-eight and thirty-two-millimeter femoral heads on cross-linked polyethylene acetabular cups in a wear simulator","volume":"85","author":"Hermida","year":"2003","journal-title":"J. Bone Jt. Surg."},{"key":"10.1016\/j.jmbbm.2021.105072_bib27","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1016\/S0928-4931(01)00328-9","article-title":"A two-dimensional finite element model for frictional heating analysis of total hip prosthesis","volume":"17","author":"Hu","year":"2001","journal-title":"Mater. Sci. Eng. C"},{"key":"10.1016\/j.jmbbm.2021.105072_bib28","doi-asserted-by":"crossref","first-page":"721","DOI":"10.1016\/j.arth.2007.05.043","article-title":"Highly crosslinked vs conventional polyethylene particles-an in vitro comparison of biologic activities","volume":"23","author":"Illgen","year":"2008","journal-title":"J. Arthroplasty"},{"key":"10.1016\/j.jmbbm.2021.105072_bib33","doi-asserted-by":"crossref","first-page":"409","DOI":"10.1243\/0954406021525205","article-title":"Transient elastohydrodynamic lubrication analysis of ultra-high molecular weight polyethylene hip joint replacements","volume":"216","author":"Jalali-Vahid","year":"2001","journal-title":"Proc. Inst. Mech. Eng. Part C J. Mech. Eng. Sci."},{"key":"10.1016\/j.jmbbm.2021.105072_bib34","doi-asserted-by":"crossref","first-page":"317","DOI":"10.1243\/0954411991535158","article-title":"An axisymmetric contact model of ultra high molecular weight polyethylene cups against metallic femoral heads for artificial hip joint replacements","volume":"213","author":"Jin","year":"1999","journal-title":"Proc. Inst. Mech. Eng. Part H-Journal Eng. Med."},{"key":"10.1016\/j.jmbbm.2021.105072_bib35","doi-asserted-by":"crossref","first-page":"912","DOI":"10.1016\/j.jbiomech.2009.01.005","article-title":"Enhanced computational prediction of polyethylene wear in hip joints by incorporating cross-shear and contact pressure in additional to load and sliding distance: effect of head diameter","volume":"42","author":"Kang","year":"2009","journal-title":"J. Biomech."},{"issue":"32","key":"10.1016\/j.jmbbm.2021.105072_bib36","first-page":"1","article-title":"The effect of geometry and abduction angle on the stresses in cemented UHMWPE acetabular cups - finite element simulations and experimental tests","volume":"4","author":"Korhonen","year":"2005","journal-title":"Biomed. Eng. OnLine"},{"key":"10.1016\/j.jmbbm.2021.105072_bib37","doi-asserted-by":"crossref","first-page":"492","DOI":"10.1002\/jbm.10309","article-title":"Deconvolution of surface topology for quantification of initial wear in highly cross-linked acetabular components for THA","volume":"63","author":"Kurtz","year":"2002","journal-title":"J. Biomed. Mater. Res."},{"key":"10.1016\/j.jmbbm.2021.105072_bib38","doi-asserted-by":"crossref","first-page":"2262","DOI":"10.1007\/s11999-011-1872-4","article-title":"History and systematic review of wear and osteolysis outcomes for first-generation highly crosslinked polyethylene","volume":"469","author":"Kurtz","year":"2011","journal-title":"Clin. Orthop. Relat. Res."},{"key":"10.1016\/j.jmbbm.2021.105072_bib39","doi-asserted-by":"crossref","first-page":"16","DOI":"10.1243\/09544119JEIM819","article-title":"A new formulation for the prediction of polyethylene wear in artificial hip joints","volume":"225","author":"Liu","year":"2011","journal-title":"Proc. Inst. Mech. Eng. Part H J. Eng. Med."},{"key":"10.1016\/j.jmbbm.2021.105072_bib40","series-title":"19th Ann. Mtg. Soc. Biomater. Birmingham, AL","first-page":"184","article-title":"Evidence for the generation of sub-micron polyethylene wear particles by micro-adhesive wear in acetabular cups","author":"McKellop","year":"1993"},{"key":"10.1016\/j.jmbbm.2021.105072_bib7","series-title":"G7 Dual Mobility Construct - Surgical Technique","author":"Zimmer Biomet","year":"2015"},{"key":"10.1016\/j.jmbbm.2021.105072_bib41","unstructured":"Medacta, \"Versafitcup - A New Generation\", Rose & Associates, Inc, (n.d."},{"key":"10.1016\/j.jmbbm.2021.105072_bib42","doi-asserted-by":"crossref","first-page":"1756","DOI":"10.2106\/JBJS.J.01858","article-title":"Comparison of ten-year survivorship of hip prostheses with use of conventional polyethylene, metal-on-metal, or ceramic-on-ceramic bearings","volume":"94","author":"Milo\u0161ev","year":"2012","journal-title":"J. Bone Jt. Surg. - Ser. A."},{"key":"10.1016\/j.jmbbm.2021.105072_bib43","doi-asserted-by":"crossref","first-page":"149","DOI":"10.1054\/arth.2001.20540","article-title":"A novel method of cross-linking ultra-high-molecular-weight polyethylene to improve wear, reduce oxidation, and retain mechanical properties: recipient of the 1999 HAP Paul Award","volume":"16","author":"Muratoglu","year":"2001","journal-title":"J. Arthroplasty"},{"key":"10.1016\/j.jmbbm.2021.105072_bib44","doi-asserted-by":"crossref","first-page":"580","DOI":"10.1016\/j.arth.2005.07.009","article-title":"Wear resistance and mechanical properties of highly cross-linked, ultrahigh--molecular weight polyethylene doped with vitamin E","volume":"21","author":"Oral","year":"2006","journal-title":"J. Arthroplasty"},{"key":"10.1016\/j.jmbbm.2021.105072_bib45","series-title":"Proc. Inst. Mech. Eng. Conf. Proc","first-page":"8","article-title":"Forces transmitted by joints in the human body","author":"Paul","year":"1966"},{"key":"10.1016\/j.jmbbm.2021.105072_bib46","first-page":"1","article-title":"Contact stress assessment of conventional and highly crosslinked ultra high molecular weight polyethylene acetabular liners with finite element analysis and pressure sensitive film","volume":"80","author":"Plank","year":"2007","journal-title":"J. Biomed. Mater. Res. Part B Appl. Biomater. An Off. J. Soc. Biomater. Japanese Soc. Biomater. Aust. Soc. Biomater. Korean Soc. Biomater."},{"key":"10.1016\/j.jmbbm.2021.105072_bib47","doi-asserted-by":"crossref","first-page":"111","DOI":"10.1016\/j.jmbbm.2013.10.028","article-title":"Impact resistance and fractography in ultra high molecular weight polyethylenes","volume":"30","author":"Pu\u00e9rtolas","year":"2014","journal-title":"J. Mech. Behav. Biomed. Mater."},{"key":"10.1016\/j.jmbbm.2021.105072_bib48","doi-asserted-by":"crossref","first-page":"S116","DOI":"10.2106\/00004623-200100022-00009","article-title":"Relationship between gravimetric wear and particle generation in hip simulators: conventional compared with cross-linked polyethylene","volume":"83","author":"Ries","year":"2001","journal-title":"J. Bone Jt. Surg."},{"key":"10.1016\/j.jmbbm.2021.105072_bib68","series-title":"Surgery of the hip","first-page":"66","article-title":"Materials in hip surgery: Ultra-High-Molecular-Weight Polyethylene","author":"Rimnac","year":"2019"},{"key":"10.1016\/j.jmbbm.2021.105072_bib49","doi-asserted-by":"crossref","first-page":"72","DOI":"10.3390\/lubricants8070072","article-title":"A mixed elasto-hydrodynamic lubrication model for wear calculation in artificial hip joints","volume":"8","author":"Ruggiero","year":"2020","journal-title":"Lubricants"},{"key":"10.1016\/j.jmbbm.2021.105072_bib50","doi-asserted-by":"crossref","first-page":"203420","DOI":"10.1016\/j.wear.2020.203420","article-title":"In silico total hip replacement wear testing in the framework of ISO 14242-3 accounting for mixed elasto-hydrodynamic lubrication effects","volume":"460","author":"Ruggiero","year":"2020","journal-title":"Wear"},{"key":"10.1016\/j.jmbbm.2021.105072_bib51","doi-asserted-by":"crossref","first-page":"723","DOI":"10.1243\/09544119JEIM146","article-title":"Effect of contact pressure on wear and friction of ultra-high molecular weight polyethylene in multidirectional sliding","volume":"220","author":"Saikko","year":"2006","journal-title":"Proc. Inst. Mech. Eng. Part H J. Eng. Med."},{"key":"10.1016\/j.jmbbm.2021.105072_bib52","doi-asserted-by":"crossref","first-page":"1819","DOI":"10.1016\/S0021-9290(03)00228-8","article-title":"An improved method of computing the wear factor for total hip prostheses involving the variation of relative motion and contact pressure with location on the bearing surface","volume":"36","author":"Saikko","year":"2003","journal-title":"J. Biomech."},{"key":"10.1016\/j.jmbbm.2021.105072_bib53","first-page":"117","article-title":"Advances in tribological testing of artificial joint biomaterials using multidirectional pin-on-disk testers","volume":"31","author":"Saikko","year":"2013","journal-title":"J. Mech. Behav. Biomed. Mater."},{"key":"10.1016\/j.jmbbm.2021.105072_bib70","series-title":"International application published under the Patent Cooperation Treaty (PCT) with an International Publication Number WO 2020\/260206 A1","article-title":"A prosthetic implant","author":"Schembri Wismayer","year":"2020"},{"key":"10.1016\/j.jmbbm.2021.105072_bib54","doi-asserted-by":"crossref","first-page":"2660","DOI":"10.1016\/j.arth.2018.03.019","article-title":"A retrieval analysis of impingement in dual-mobility liners","volume":"33","author":"Scott","year":"2018","journal-title":"J. Arthroplasty"},{"key":"10.1016\/j.jmbbm.2021.105072_bib55","doi-asserted-by":"crossref","first-page":"81","DOI":"10.1002\/jbm.820280111","article-title":"Macrophage\/particle interactions: effect of size, composition and surface area","volume":"28","author":"Shanbhag","year":"1994","journal-title":"J. Biomed. Mater. Res."},{"key":"10.1016\/j.jmbbm.2021.105072_bib56","doi-asserted-by":"crossref","first-page":"1720","DOI":"10.3389\/fimmu.2020.01720","article-title":"Blockade of XCL1f\/lymphotactin ameliorates severity of periprosthetic osteolysis triggered by polyethylene-particles","volume":"11","author":"Tian","year":"2020","journal-title":"Front. Immunol."},{"key":"10.1016\/j.jmbbm.2021.105072_bib57","doi-asserted-by":"crossref","first-page":"38","DOI":"10.1016\/S0043-1648(00)00522-6","article-title":"A unified theory of wear for ultra-high molecular weight polyethylene in multi-directional sliding","volume":"248","author":"Wang","year":"2001","journal-title":"Wear"},{"key":"10.1016\/j.jmbbm.2021.105072_bib58","doi-asserted-by":"crossref","first-page":"619","DOI":"10.1002\/jbm.820290509","article-title":"Role of cyclic plastic deformation in the wear of UHMWPE acetabular cups","volume":"29","author":"Wang","year":"1995","journal-title":"J. Biomed. Mater. Res."},{"key":"10.1016\/j.jmbbm.2021.105072_bib59","doi-asserted-by":"crossref","first-page":"141","DOI":"10.1243\/PIME_PROC_1996_210_407_02","article-title":"Mechanistic and morphological origins of ultra-high molecular weight polyethylene wear debris in total joint replacement prostheses","volume":"210","author":"Wang","year":"1996","journal-title":"Proc. Inst. Mech. Eng. Part H J. Eng. Med."},{"key":"10.1016\/j.jmbbm.2021.105072_bib60","doi-asserted-by":"crossref","first-page":"230","DOI":"10.1016\/S0043-1648(96)07362-0","article-title":"Orientation softening in the deformation and wear of ultra-high molecular weight polyethylene","volume":"203","author":"Wang","year":"1997","journal-title":"Wear"},{"key":"10.1016\/j.jmbbm.2021.105072_bib61","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1016\/S0301-679X(98)00005-X","article-title":"Lubrication and wear of ultra-high molecular weight polyethylene in total joint replacements","volume":"31","author":"Wang","year":"1998","journal-title":"Tribol. Int."},{"key":"10.1016\/j.jmbbm.2021.105072_bib62","doi-asserted-by":"crossref","first-page":"133","DOI":"10.1243\/0954411011533698","article-title":"Effect of contact stress on friction and wear of ultra-high molecular weight polyethylene in total hip replacement","volume":"215","author":"Wang","year":"2001","journal-title":"Proc. Inst. Mech. Eng. Part H J. Eng. Med."},{"key":"10.1016\/j.jmbbm.2021.105072_bib63","doi-asserted-by":"crossref","first-page":"3","DOI":"10.2495\/TD100011","article-title":"Tribological modelling of spherical bearings with complex spherical-based geometry and motion","volume":"66","author":"Wang","year":"2010","journal-title":"WIT Trans. Eng. Sci."},{"key":"10.1016\/j.jmbbm.2021.105072_bib67","series-title":"Surgery of the hip","first-page":"37","article-title":"Tribology of the artificial hip","author":"Wimmer","year":"2019"},{"key":"10.1016\/j.jmbbm.2021.105072_bib65","doi-asserted-by":"crossref","first-page":"1","DOI":"10.2474\/trol.10.1","article-title":"Investigation on oxidation of shelf-aged crosslinked Ultra-High Molecular Weight Polyethylene (UHMWPE) and its effects on wear characteristics","volume":"10","author":"Zhang","year":"2015","journal-title":"Tribol. Online"}],"container-title":["Journal of the Mechanical Behavior of Biomedical Materials"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1751616121006974?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1751616121006974?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,28]],"date-time":"2025-10-28T22:42:07Z","timestamp":1761691327000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1751616121006974"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,3]]},"references-count":61,"alternative-id":["S1751616121006974"],"URL":"https:\/\/doi.org\/10.1016\/j.jmbbm.2021.105072","relation":{},"ISSN":["1751-6161"],"issn-type":[{"value":"1751-6161","type":"print"}],"subject":[],"published":{"date-parts":[[2022,3]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"A novel hip joint prosthesis with uni-directional articulations for reduced wear","name":"articletitle","label":"Article Title"},{"value":"Journal of the Mechanical Behavior of Biomedical Materials","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jmbbm.2021.105072","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2022 The Authors. Published by Elsevier Ltd.","name":"copyright","label":"Copyright"}],"article-number":"105072"}}