{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,10]],"date-time":"2026-11-10T22:21:09Z","timestamp":1794349269134,"version":"4.9.0"},"reference-count":29,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2023,10,1]],"date-time":"2023-10-01T00:00:00Z","timestamp":1696118400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2023,10,1]],"date-time":"2023-10-01T00:00:00Z","timestamp":1696118400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2023,10,1]],"date-time":"2023-10-01T00:00:00Z","timestamp":1696118400000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-017"},{"start":{"date-parts":[[2023,10,1]],"date-time":"2023-10-01T00:00:00Z","timestamp":1696118400000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-037"},{"start":{"date-parts":[[2023,10,1]],"date-time":"2023-10-01T00:00:00Z","timestamp":1696118400000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-012"},{"start":{"date-parts":[[2023,10,1]],"date-time":"2023-10-01T00:00:00Z","timestamp":1696118400000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-029"},{"start":{"date-parts":[[2023,10,1]],"date-time":"2023-10-01T00:00:00Z","timestamp":1696118400000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-004"}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of the Mechanical Behavior of Biomedical Materials"],"published-print":{"date-parts":[[2023,10]]},"DOI":"10.1016\/j.jmbbm.2023.106076","type":"journal-article","created":{"date-parts":[[2023,8,14]],"date-time":"2023-08-14T01:50:39Z","timestamp":1691977839000},"page":"106076","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":11,"special_numbering":"C","title":["Static compression and fatigue behavior of heat-treated selective laser melted titanium alloy (Ti6Al4V) gyroid cylinders"],"prefix":"10.1016","volume":"146","author":[{"ORCID":"https:\/\/orcid.org\/0009-0003-3333-1236","authenticated-orcid":false,"given":"Sydney","family":"Hitchon","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"William","family":"Anderson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jaques S.","family":"Milner","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9680-952X","authenticated-orcid":false,"given":"Gregory","family":"Hong","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Todor","family":"Ivanov","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4127-8645","authenticated-orcid":false,"given":"Ryan","family":"Willing","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David","family":"Holdsworth","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.jmbbm.2023.106076_bib1","doi-asserted-by":"crossref","first-page":"262","DOI":"10.1016\/j.jmbbm.2017.07.035","article-title":"Finite element analysis of mechanical behaviour, permeability and fluid induced wall shear stress of high porosity scaffolds with gyroid and lattice-based architectures","volume":"75","author":"Ali","year":"2017","journal-title":"J. Mech. Behav. Biomed. Mater."},{"key":"10.1016\/j.jmbbm.2023.106076_bib2","first-page":"167","article-title":"Topology-mechanical property relationship of 3D-printed strut, skeletal, and sheet based periodic metallic cellular materials","volume":"19","author":"Al-Ketan","year":"2018","journal-title":"Addit. Manuf."},{"key":"10.1016\/j.jmbbm.2023.106076_bib3","doi-asserted-by":"crossref","first-page":"1774","DOI":"10.1002\/jor.23445","article-title":"Fully porous 3D printed titanium femoral stem to reduce stress shielding following total hip arthroplasty","volume":"35","author":"Arabnejad","year":"2017","journal-title":"J. Orthop. Res."},{"issue":"6","key":"10.1016\/j.jmbbm.2023.106076_bib4","doi-asserted-by":"crossref","first-page":"2141","DOI":"10.1002\/jbm.a.35358","article-title":"Controlled drug release from antibiotic-loaded layered double hydroxide coatings on porous titanium implants in a mouse model","volume":"103","author":"Badar","year":"2015","journal-title":"J. Biomed. Mater. Res., Part A"},{"key":"10.1016\/j.jmbbm.2023.106076_bib5","article-title":"A comparison of all-hexahedra and all-tetrahedra finite element meshes for elastic and elasto-plastic analysis","volume":"17","author":"Benzley","year":"1995","journal-title":"Proc. Fourth IMR"},{"key":"10.1016\/j.jmbbm.2023.106076_bib6","doi-asserted-by":"crossref","first-page":"1","DOI":"10.3390\/ma12081313","article-title":"Permeability versus design in TPMS scaffolds","volume":"12","author":"Castro","year":"2019","journal-title":"Materials"},{"issue":"2","key":"10.1016\/j.jmbbm.2023.106076_bib7","first-page":"12","article-title":"Design and analysis of porous functionally graded femoral prostheses with improved stress shielding","volume":"4","author":"Chashmi","year":"2020","journal-title":"Design"},{"key":"10.1016\/j.jmbbm.2023.106076_bib8","doi-asserted-by":"crossref","DOI":"10.1016\/j.seppur.2020.117594","article-title":"The potential use of a gyroid structure to represent monolithic matrices for bioseparation purposes: fluid dynamics and mass transfer analysis via CFD","volume":"254","author":"Coimbra","year":"2021","journal-title":"Separ. Purif. Technol."},{"issue":"9","key":"10.1016\/j.jmbbm.2023.106076_bib9","doi-asserted-by":"crossref","first-page":"1299","DOI":"10.1016\/j.dental.2018.06.002","article-title":"Fatigue lifetime prediction of a reduced-diameter dental implant system: numerical and experimental study","volume":"34","author":"Duan","year":"2018","journal-title":"Dent. Mater."},{"key":"10.1016\/j.jmbbm.2023.106076_bib10","doi-asserted-by":"crossref","first-page":"166","DOI":"10.1016\/j.ijpharm.2013.04.076","article-title":"Porous orthopaedic steel implant as an antibiotic eluting device: prevention of post-surgical infection on an ovine model","volume":"452","author":"Gimeno","year":"2013","journal-title":"Int. J. Pharm."},{"key":"10.1016\/j.jmbbm.2023.106076_bib11","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1002\/adma.201705708","article-title":"An overview of materials with triply periodic minimal surfaces and related geometry: from biological structures to self-assembled Systems","volume":"30","author":"Han","year":"2018","journal-title":"Adv. Mater."},{"issue":"6","key":"10.1016\/j.jmbbm.2023.106076_bib12","doi-asserted-by":"crossref","first-page":"2947","DOI":"10.1002\/mrm.29136","article-title":"Effective magnetic susceptibility of 3D-printed porous metal scaffolds","volume":"87","author":"Hong","year":"2022","journal-title":"Magn. Reason Med."},{"key":"10.1016\/j.jmbbm.2023.106076_bib13","series-title":"Mechanical Testing of Metals \u2013 Ductility Testing \u2013 Compression Test for Porous and Cellular Metals","year":"2011"},{"key":"10.1016\/j.jmbbm.2023.106076_bib14","doi-asserted-by":"crossref","first-page":"4845","DOI":"10.1021\/acs.nanolett.8b01431","article-title":"Multiscale mechanics of triply periodic minimal surfaces of three-dimensional graphene foams","volume":"18","author":"Jung","year":"2018","journal-title":"Nano Lett."},{"key":"10.1016\/j.jmbbm.2023.106076_bib15","doi-asserted-by":"crossref","first-page":"610","DOI":"10.1016\/j.actbio.2019.05.046","article-title":"Fatigue behaviour of as-built selective laser melted titanium scaffolds with sheet-based gyroid microarchitecture for bone tissue engineering","volume":"94","author":"Kelly","year":"2019","journal-title":"Acta Biomater."},{"key":"10.1016\/j.jmbbm.2023.106076_bib16","article-title":"Processing, structure, and properties of additively manufactured titanium scaffolds with gyroid-sheet architecture","volume":"41","author":"Kelly","year":"2021","journal-title":"Addit. Manuf."},{"key":"10.1016\/j.jmbbm.2023.106076_bib17","first-page":"3","article-title":"Porous tantalum structure integrated on Ti6Al4V base by Laser Powder Bed Fusion for enhanced bony-ingrowth implants: in vitro and in vivo validation","volume":"7","author":"Lei","year":"2022","journal-title":"Bioact. Mater."},{"key":"10.1016\/j.jmbbm.2023.106076_bib18","article-title":"Mechanical interaction between additive-manufactured metal lattice structures and bone in compression: implications for stress shielding of orthopaedic implants","volume":"121","author":"Liverani","year":"2021","journal-title":"J. Mech. Behav. Biomater."},{"key":"10.1016\/j.jmbbm.2023.106076_bib19","doi-asserted-by":"crossref","DOI":"10.1016\/j.ijmecsci.2020.106180","article-title":"The influence of selective laser melting defects on the fatigue properties of Ti6Al4V porosity graded gyroids for bone implants","volume":"193","author":"Mahmoud","year":"2021","journal-title":"Int. J. Mech. Sci."},{"key":"10.1016\/j.jmbbm.2023.106076_bib20","article-title":"Process-structure-Property relationships in selective laser melting of porosity graded gyroids","volume":"13","author":"Mahmoud","year":"2019","journal-title":"J. Med. Dev. Trans. ASME"},{"issue":"7","key":"10.1016\/j.jmbbm.2023.106076_bib21","doi-asserted-by":"crossref","first-page":"1076","DOI":"10.1016\/j.jse.2015.11.011","article-title":"Comparison of proximal humeral bone stresses between stemless, short stem, and standard stem length: a finite element analysis","volume":"25","author":"Razfar","year":"2016","journal-title":"J. Shoulder Elbow Surg."},{"key":"10.1016\/j.jmbbm.2023.106076_bib22","article-title":"The effect of inhomogenous trabecular stiffness relationship selection on finite element outcomes for shoulder arthroplasty","volume":"141","author":"Reeves","year":"2019","journal-title":"J. Biomed. Eng."},{"key":"10.1016\/j.jmbbm.2023.106076_bib23","series-title":"Fe-Safe User Manual Volume 2: Fatigue Theory Reference Manual","year":"2017"},{"issue":"4","key":"10.1016\/j.jmbbm.2023.106076_bib24","doi-asserted-by":"crossref","first-page":"199","DOI":"10.1520\/JTE11613J","article-title":"Generalized application of neuber's rule","volume":"8","author":"Seeger","year":"1980","journal-title":"J. Test. Eval."},{"key":"10.1016\/j.jmbbm.2023.106076_bib25","doi-asserted-by":"crossref","first-page":"657","DOI":"10.1007\/s00170-020-06174-0","article-title":"Modal characterization of additively manufactured TPMS structures: comparison between different modeling methods","volume":"115","author":"Simsek","year":"2021","journal-title":"Int. J. Adv. Manuf. Technol."},{"key":"10.1016\/j.jmbbm.2023.106076_bib26","doi-asserted-by":"crossref","DOI":"10.1016\/j.ijfatigue.2020.105702","article-title":"Surface roughness effects on fatigue behaviour of gyroid cellular structures obtained by additive manufacturing","volume":"138","author":"Y\u00e1nez","year":"2020","journal-title":"Int. J. Fatig."},{"key":"10.1016\/j.jmbbm.2023.106076_bib27","doi-asserted-by":"crossref","first-page":"49","DOI":"10.1016\/j.actamat.2019.09.042","article-title":"Compression-compression fatigue behaviour of gyroid-type triply periodic minimal surface porous structures fabricated by selective laser melting","volume":"181","author":"Yang","year":"2019","journal-title":"Acta Biomater."},{"key":"10.1016\/j.jmbbm.2023.106076_bib28","first-page":"27","article-title":"The effects of grit size and blasting pressure on the surface properties of grit blasted Ti6Al4V alloy","volume":"32","author":"Yetik","year":"2020","journal-title":"Mater. Today: Proc."},{"key":"10.1016\/j.jmbbm.2023.106076_bib29","doi-asserted-by":"crossref","DOI":"10.1016\/j.matdes.2020.108754","article-title":"The select of internal architecture for porous Ti alloy scaffold: a compromise between mechanical properties and permeability","volume":"192","author":"Yu","year":"2020","journal-title":"Mater. Des."}],"container-title":["Journal of the Mechanical Behavior of Biomedical Materials"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1751616123004290?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1751616123004290?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,28]],"date-time":"2025-10-28T22:51:05Z","timestamp":1761691865000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1751616123004290"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,10]]},"references-count":29,"alternative-id":["S1751616123004290"],"URL":"https:\/\/doi.org\/10.1016\/j.jmbbm.2023.106076","relation":{},"ISSN":["1751-6161"],"issn-type":[{"value":"1751-6161","type":"print"}],"subject":[],"published":{"date-parts":[[2023,10]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Static compression and fatigue behavior of heat-treated selective laser melted titanium alloy (Ti6Al4V) gyroid cylinders","name":"articletitle","label":"Article Title"},{"value":"Journal of the Mechanical Behavior of Biomedical Materials","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jmbbm.2023.106076","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2023 Elsevier Ltd. All rights reserved.","name":"copyright","label":"Copyright"}],"article-number":"106076"}}