{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T04:02:16Z","timestamp":1790827336897,"version":"4.1.0"},"reference-count":78,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2023,11,1]],"date-time":"2023-11-01T00:00:00Z","timestamp":1698796800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2023,11,1]],"date-time":"2023-11-01T00:00:00Z","timestamp":1698796800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2023,8,29]],"date-time":"2023-08-29T00:00:00Z","timestamp":1693267200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/100014013","name":"UK Research and Innovation","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100014013","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100000266","name":"Engineering and Physical Sciences Research Council","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100000266","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100018955","name":"NIHR Leeds Musculoskeletal Biomedical Research Unit","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100018955","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of the Mechanical Behavior of Biomedical Materials"],"published-print":{"date-parts":[[2023,11]]},"DOI":"10.1016\/j.jmbbm.2023.106084","type":"journal-article","created":{"date-parts":[[2023,8,25]],"date-time":"2023-08-25T12:04:36Z","timestamp":1692965076000},"page":"106084","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":16,"special_numbering":"C","title":["Highly lubricious SPMK-g-PEEK implant surfaces to facilitate rehydration of articular cartilage"],"prefix":"10.1016","volume":"147","author":[{"ORCID":"https:\/\/orcid.org\/0009-0009-0229-4931","authenticated-orcid":false,"given":"Robert J.","family":"Elkington","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Richard M.","family":"Hall","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andrew R.","family":"Beadling","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hemant","family":"Pandit","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael G.","family":"Bryant","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"issue":"10","key":"10.1016\/j.jmbbm.2023.106084_b1","doi-asserted-by":"crossref","first-page":"658","DOI":"10.1136\/ard.44.10.658","article-title":"Direct measurement of local pressures in the cadaveric human hip joint during simulated level walking","volume":"44","author":"Adams","year":"1985","journal-title":"Ann. Rheumat. Dis."},{"key":"10.1016\/j.jmbbm.2023.106084_b2","first-page":"1","article-title":"Rapid acetabular chondrolysis following hemiarthroplasty of the hip: A poor prognostic sign","volume":"2019","author":"Adenikinju","year":"2019","journal-title":"Case Rep. Orthop."},{"issue":"2","key":"10.1016\/j.jmbbm.2023.106084_b3","doi-asserted-by":"crossref","first-page":"165","DOI":"10.1115\/1.3138475","article-title":"An analysis of the unconfined compression of articular cartilage","volume":"106","author":"Armstrong","year":"1984","journal-title":"J. Biomech. Eng."},{"issue":"1","key":"10.1016\/j.jmbbm.2023.106084_b4","doi-asserted-by":"crossref","first-page":"88","DOI":"10.2106\/00004623-198264010-00013","article-title":"Variations in the intrinsic mechanical properties of human articular cartilage with age, degeneration, and water content","volume":"64","author":"Armstrong","year":"1982","journal-title":"J. Bone Joint Surg.. Am. Vol."},{"issue":"1","key":"10.1016\/j.jmbbm.2023.106084_b5","doi-asserted-by":"crossref","first-page":"81","DOI":"10.1115\/1.2796069","article-title":"A theoretical formulation for boundary friction in articular cartilage","volume":"119","author":"Ateshian","year":"1997","journal-title":"J. Biomech. Eng."},{"issue":"10077","key":"10.1016\/j.jmbbm.2023.106084_b6","doi-asserted-by":"crossref","first-page":"1424","DOI":"10.1016\/S0140-6736(17)30059-4","article-title":"The effect of patient age at intervention on risk of implant revision after total replacement of the hip or knee: A population-based cohort study","volume":"389","author":"Bayliss","year":"2017","journal-title":"Lancet"},{"key":"10.1016\/j.jmbbm.2023.106084_b7","series-title":"Surfactants in Tribology, Volume 3","author":"Biresaw","year":"2013"},{"key":"10.1016\/j.jmbbm.2023.106084_b8","first-page":"82","article-title":"Joint contact stress: A reasonable surrogate for biological processes?","volume":"25","author":"Brand","year":"2005","journal-title":"Iowa orthop. J."},{"issue":"September","key":"10.1016\/j.jmbbm.2023.106084_b9","doi-asserted-by":"crossref","first-page":"8","DOI":"10.1016\/j.biotri.2017.09.001","article-title":"Cartilage and joint lubrication: New insights into the role of hydrodynamics","volume":"12","author":"Burris","year":"2017","journal-title":"Biotribology"},{"key":"10.1016\/j.jmbbm.2023.106084_b10","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1007\/s11249-019-1158-7","article-title":"How sliding and hydrodynamics contribute to articular cartilage fluid and lubrication recovery","volume":"67","author":"Burris","year":"2019","journal-title":"Tribol. Lett."},{"issue":"4","key":"10.1016\/j.jmbbm.2023.106084_b11","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1115\/1.4004760","article-title":"Friction and wear of hemiarthroplasty biomaterials in reciprocating sliding contact with articular cartilage","volume":"133","author":"Chan","year":"2011","journal-title":"J. Tribol."},{"issue":"9","key":"10.1016\/j.jmbbm.2023.106084_b12","doi-asserted-by":"crossref","first-page":"1303","DOI":"10.1002\/cphc.200700131","article-title":"Robust, biomimetic polymer brush layers grown directly from a planar mica surface","volume":"8","author":"Chen","year":"2007","journal-title":"ChemPhysChem"},{"issue":"12","key":"10.1016\/j.jmbbm.2023.106084_b13","doi-asserted-by":"crossref","DOI":"10.1063\/1.4916133","article-title":"Excluded volume effects in compressed polymer brushes: A density functional theory","volume":"142","author":"Chen","year":"2015","journal-title":"J. Chem. Phys."},{"key":"10.1016\/j.jmbbm.2023.106084_b14","doi-asserted-by":"crossref","first-page":"549","DOI":"10.1016\/j.polymer.2017.02.085","article-title":"Aqueous lubrication of poly(etheretherketone) via surface-initiated polymerization of electrolyte monomers","volume":"116","author":"Chouwatat","year":"2017","journal-title":"Polymer"},{"issue":"74 -Lub-37","key":"10.1016\/j.jmbbm.2023.106084_b15","first-page":"358","article-title":"Friction and wear studies of articular cartilage: A scanning electron microscopic study","author":"Clarke","year":"1974","journal-title":"Am. Soc. Mech. Eng. (Paper)"},{"issue":"1","key":"10.1016\/j.jmbbm.2023.106084_b16","doi-asserted-by":"crossref","first-page":"147","DOI":"10.2106\/00004623-197254010-00014","article-title":"A comparison of the physical behavior of normal articular cartilage and the arthroplasty surface","volume":"54","author":"Coletti","year":"1972","journal-title":"J. Bone Joint Surg."},{"issue":"3","key":"10.1016\/j.jmbbm.2023.106084_b17","doi-asserted-by":"crossref","first-page":"196","DOI":"10.1067\/mse.2000.105137","article-title":"Quantitative determination of articular pressure in the human shoulder joint","volume":"9","author":"Conzen","year":"2000","journal-title":"J. Shoulder Elbow Surg."},{"issue":"4","key":"10.1016\/j.jmbbm.2023.106084_b18","doi-asserted-by":"crossref","first-page":"456","DOI":"10.1016\/S0749-8063(97)90124-9","article-title":"Cartilage injuries: A review of 31,516 knee arthroscopies","volume":"13","author":"Curl","year":"1997","journal-title":"Arthroscopy: J. Arthrosc. Related Surg."},{"issue":"3","key":"10.1016\/j.jmbbm.2023.106084_b19","doi-asserted-by":"crossref","first-page":"377","DOI":"10.1016\/j.joca.2009.10.009","article-title":"Cartilage degeneration in the goat knee caused by treating localized cartilage defects with metal implants","volume":"18","author":"Custers","year":"2010","journal-title":"Osteoarthr. Cartil."},{"issue":"12","key":"10.1016\/j.jmbbm.2023.106084_b20","doi-asserted-by":"crossref","first-page":"2901","DOI":"10.1007\/s10439-020-02558-1","article-title":"The characteristic recovery time as a novel, noninvasive metric for assessing in vivo cartilage mechanical function","volume":"48","author":"Cutcliffe","year":"2020","journal-title":"Ann. Biomed. Eng."},{"issue":"3","key":"10.1016\/j.jmbbm.2023.106084_b21","doi-asserted-by":"crossref","first-page":"151","DOI":"10.1080\/17515831.2020.1720381","article-title":"Compliant-poroelastic lubrication in cartilage-on-cartilage line contacts","volume":"14","author":"De Boer","year":"2020","journal-title":"Tribol.-Mater., Surf. Interfaces"},{"issue":"May 2019","key":"10.1016\/j.jmbbm.2023.106084_b22","article-title":"A porohyperelastic lubrication model for articular cartilage in the natural synovial joint","volume":"149","author":"de Boer","year":"2020","journal-title":"Tribol. Int."},{"key":"10.1016\/j.jmbbm.2023.106084_b23","doi-asserted-by":"crossref","DOI":"10.1039\/C1SM06335A","article-title":"Biomimetic lubrication","author":"Dedinaite","year":"2012","journal-title":"Soft Matter"},{"issue":"1","key":"10.1016\/j.jmbbm.2023.106084_b24","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/s12891-020-03292-4","article-title":"Effects of focal metallic implants on opposing cartilage\u2013An in-vitro study with an abrasion test machine","volume":"21","author":"Diermeier","year":"2020","journal-title":"BMC Musculoskelet. Disord."},{"key":"10.1016\/j.jmbbm.2023.106084_b25","series-title":"The finctional behavior of human synovial joints-part I: Natural joints. (july)","first-page":"369","author":"Dowson","year":"1975"},{"key":"10.1016\/j.jmbbm.2023.106084_b26","doi-asserted-by":"crossref","DOI":"10.1016\/j.yrtph.2021.105004","article-title":"An integrated benefit-risk assessment of cobalt-containing alloys used in medical devices: Implications for regulatory requirements in the European union","volume":"125","author":"Eichenbaum","year":"2021","journal-title":"Regul. Toxicol. Pharmacol."},{"key":"10.1016\/j.jmbbm.2023.106084_b27","first-page":"34","article-title":"Biomimetic highly lubricious polyelectrolyte functionalized peek surfaces for novel hemiarthroplasty implants and focal resurfacing","volume":"vol. 103","author":"Elkington","year":"2021"},{"issue":"4","key":"10.1016\/j.jmbbm.2023.106084_b28","doi-asserted-by":"crossref","first-page":"329","DOI":"10.1243\/0954411991535167","article-title":"The influence of continuous sliding and subsequent surface wear on the friction of articular cartilage","volume":"213","author":"Forster","year":"1999","journal-title":"Proc. Inst. Mech. Eng., Part H: J. Eng. Med."},{"issue":"30","key":"10.1016\/j.jmbbm.2023.106084_b29","doi-asserted-by":"crossref","first-page":"5151","DOI":"10.1016\/j.biomaterials.2006.05.046","article-title":"Biomimetic phosphorylcholine polymer grafting from polydimethylsiloxane surface using photo-induced polymerization","volume":"27","author":"Goda","year":"2006","journal-title":"Biomaterials"},{"issue":"suppl_2","key":"10.1016\/j.jmbbm.2023.106084_b30","doi-asserted-by":"crossref","first-page":"25","DOI":"10.2106\/00004623-200300002-00004","article-title":"Autologous osteochondral mosaicplasty for the treatment of full-thickness defects of weight-bearing joints: Ten years of experimental and clinical experience","volume":"85","author":"Hangody","year":"2003","journal-title":"J. Bone Joint Surg."},{"issue":"7","key":"10.1016\/j.jmbbm.2023.106084_b31","doi-asserted-by":"crossref","first-page":"730","DOI":"10.1053\/jars.2002.32839","article-title":"Articular cartilage defects in 1,000 knee arthroscopies","volume":"18","author":"Hjelle","year":"2002","journal-title":"Arthroscopy: J. Arthrosc. Related Surg."},{"key":"10.1016\/j.jmbbm.2023.106084_b32","series-title":"Contact pressures in the human hip joint measured in vivo, vol. 83 (May)","first-page":"2879","author":"Hodge","year":"1986"},{"issue":"9","key":"10.1016\/j.jmbbm.2023.106084_b33","doi-asserted-by":"crossref","first-page":"585","DOI":"10.1038\/pj.2015.45","article-title":"Highly lubricated polymer interfaces for advanced artificial hip joints through biomimetic design","volume":"47","author":"Ishihara","year":"2015","journal-title":"Polym. J."},{"key":"10.1016\/j.jmbbm.2023.106084_b34","series-title":"Highly lubricated polymer interfaces for advanced artificial hip joints through biomimetic design, no. March","first-page":"1","author":"Ishihara","year":"2015"},{"issue":"1","key":"10.1016\/j.jmbbm.2023.106084_b35","doi-asserted-by":"crossref","first-page":"498","DOI":"10.1080\/14686996.2022.2119883","article-title":"Biomimetic materials based on zwitterionic polymers toward human-friendly medical devices","volume":"23","author":"Ishihara","year":"2022","journal-title":"Sci. Technol. Adv. Mater."},{"issue":"18","key":"10.1016\/j.jmbbm.2023.106084_b36","doi-asserted-by":"crossref","first-page":"7361","DOI":"10.1021\/acs.macromol.7b01423","article-title":"Cross-linking highly lubricious phosphocholinated polymer brushes: Effect on surface interactions and frictional behavior","volume":"50","author":"Iuster","year":"2017","journal-title":"Macromolecules"},{"issue":"15","key":"10.1016\/j.jmbbm.2023.106084_b37","doi-asserted-by":"crossref","first-page":"5059","DOI":"10.1021\/acs.macromol.5b00327","article-title":"Hydration lubrication: The macromolecular domain","volume":"48","author":"Jahn","year":"2015","journal-title":"Macromolecules"},{"issue":"71","key":"10.1016\/j.jmbbm.2023.106084_b38","article-title":"Lubrication of articular cartilage","volume":"48","author":"Jahn","year":"2018","journal-title":"Phys. Today"},{"key":"10.1016\/j.jmbbm.2023.106084_b39","doi-asserted-by":"crossref","first-page":"235","DOI":"10.1146\/annurev-bioeng-081514-123305","article-title":"Lubrication of articular cartilage","volume":"18","author":"Jahn","year":"2016","journal-title":"Ann. Rev. Biomed. Eng."},{"issue":"1","key":"10.1016\/j.jmbbm.2023.106084_b40","doi-asserted-by":"crossref","first-page":"38","DOI":"10.1016\/j.mporth.2014.11.006","article-title":"(vi) focal resurfacing implants in the knee and partial knee replacements","volume":"29","author":"Jermin","year":"2015","journal-title":"Orthop. Trauma"},{"issue":"3","key":"10.1016\/j.jmbbm.2023.106084_b41","doi-asserted-by":"crossref","first-page":"175","DOI":"10.1243\/13506501JET240","article-title":"Effect of load variation on the friction properties of articular cartilage","volume":"221","author":"Katta","year":"2007","journal-title":"Proc. Inst. Mech. Eng., Part J: J. Eng. Tribol."},{"issue":"10","key":"10.1016\/j.jmbbm.2023.106084_b42","doi-asserted-by":"crossref","first-page":"2015","DOI":"10.1007\/s00264-012-1567-9","article-title":"The cartilage degeneration and joint motion of bipolar hemiarthroplasty","volume":"36","author":"Kim","year":"2012","journal-title":"Int. Orthop."},{"issue":"4","key":"10.1016\/j.jmbbm.2023.106084_b43","doi-asserted-by":"crossref","first-page":"208","DOI":"10.1002\/tcr.201000001","article-title":"Tribological properties of hydrophilic polymer brushes under wet conditions","volume":"10","author":"Kobayashi","year":"2010","journal-title":"Chem. Rec."},{"key":"10.1016\/j.jmbbm.2023.106084_b44","series-title":"Polyelectrolyte brushes : A novel stable lubrication system in aqueous conditions","first-page":"403","author":"Kobayashi","year":"2012"},{"issue":"3","key":"10.1016\/j.jmbbm.2023.106084_b45","doi-asserted-by":"crossref","first-page":"565","DOI":"10.1016\/j.orthres.2003.07.002","article-title":"Experimental verification of the role of interstitial fluid pressurization in cartilage lubrication","volume":"22","author":"Krishnan","year":"2004","journal-title":"J. Orthop. Res."},{"key":"10.1016\/j.jmbbm.2023.106084_b46","doi-asserted-by":"crossref","DOI":"10.1016\/j.biotri.2020.100159","article-title":"Comparative tribology: Articulation-induced rehydration of cartilage across species","volume":"25","author":"Kupratis","year":"2021","journal-title":"Biotribology"},{"issue":"4","key":"10.1016\/j.jmbbm.2023.106084_b47","doi-asserted-by":"crossref","first-page":"658","DOI":"10.1016\/j.biomaterials.2009.09.083","article-title":"Lubricity and stability of poly ( 2-methacryloyloxyethyl phosphorylcholine ) polymer layer on Co \u2013 Cr \u2013 Mo surface for hemi-arthroplasty to prevent degeneration of articular cartilage","volume":"31","author":"Kyomoto","year":"2010","journal-title":"Biomaterials"},{"issue":"6","key":"10.1016\/j.jmbbm.2023.106084_b48","doi-asserted-by":"crossref","first-page":"1017","DOI":"10.1016\/j.biomaterials.2009.10.055","article-title":"Self-initiated surface grafting with poly(2-methacryloyloxyethyl phosphorylcholine) on poly(ether-ether-ketone)","volume":"31","author":"Kyomoto","year":"2010","journal-title":"Biomaterials"},{"key":"10.1016\/j.jmbbm.2023.106084_b49","doi-asserted-by":"crossref","first-page":"942","DOI":"10.1007\/s11999-014-3995-x","article-title":"Multidirectional wear and impact-to-wear tests of phospholipid-polymer-grafted and vitamin E-blended crosslinked polyethylene: a pilot study","volume":"473","author":"Kyomoto","year":"2015","journal-title":"Clin. Orthop. Relat. Res."},{"issue":"March","key":"10.1016\/j.jmbbm.2023.106084_b50","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.biotri.2018.08.001","article-title":"Lubricious ionic polymer brush functionalised silicone elastomer surfaces","volume":"16","author":"Lanigan","year":"2018","journal-title":"Biotribology"},{"issue":"4","key":"10.1016\/j.jmbbm.2023.106084_b51","doi-asserted-by":"crossref","first-page":"686","DOI":"10.1021\/jz402762h","article-title":"Definitions for hydrophilicity, hydrophobicity, and superhydrophobicity: Getting the basics right","volume":"5","author":"Law","year":"2014","journal-title":"J. Phys. Chem. Lett."},{"issue":"1","key":"10.1016\/j.jmbbm.2023.106084_b52","doi-asserted-by":"crossref","first-page":"110","DOI":"10.1007\/s40544-020-0468-y","article-title":"Investigation of role of cartilage surface polymer brush border in lubrication of biological joints","volume":"10","author":"Liao","year":"2022","journal-title":"Friction"},{"key":"10.1016\/j.jmbbm.2023.106084_b53","doi-asserted-by":"crossref","first-page":"94","DOI":"10.1016\/j.cocis.2019.10.001","article-title":"Control of surface forces through hydrated boundary layers","volume":"44","author":"Lin","year":"2019","journal-title":"Curr. Opin. Colloid Interface Sci."},{"issue":"2","key":"10.1016\/j.jmbbm.2023.106084_b54","doi-asserted-by":"crossref","first-page":"213","DOI":"10.1021\/accountsmr.1c00219","article-title":"Hydration lubrication in biomedical applications: From cartilage to hydrogels","volume":"3","author":"Lin","year":"2022","journal-title":"Accounts Mater. Res."},{"issue":"22","key":"10.1016\/j.jmbbm.2023.106084_b55","doi-asserted-by":"crossref","first-page":"20452","DOI":"10.1021\/am506026e","article-title":"Hairy polyelectrolyte brushes-grafted thermosensitive microgels as artificial synovial fluid for simultaneous biomimetic lubrication and arthritis treatment","volume":"6","author":"Liu","year":"2014","journal-title":"ACS Appl. Mater. Interfaces"},{"issue":"8","key":"10.1016\/j.jmbbm.2023.106084_b56","doi-asserted-by":"crossref","first-page":"865","DOI":"10.1002\/jbm.820280805","article-title":"The effect of additive hyaluronic acid on animal joints with experimentally reduced lubricating ability","volume":"28","author":"Mabuchi","year":"1994","journal-title":"J. Biomed. Mater. Res."},{"issue":"7","key":"10.1016\/j.jmbbm.2023.106084_b57","doi-asserted-by":"crossref","first-page":"529","DOI":"10.2106\/JBJS.M.00545","article-title":"Younger age is associated with a higher risk of early periprosthetic joint infection and aseptic mechanical failure after total knee arthroplasty","volume":"96","author":"Meehan","year":"2014","journal-title":"J. Bone Joint Surg."},{"issue":"2","key":"10.1016\/j.jmbbm.2023.106084_b58","doi-asserted-by":"crossref","first-page":"141","DOI":"10.1039\/C5ME00010F","article-title":"Tribology of surface-grafted polymer brushes","volume":"1","author":"Mocny","year":"2016","journal-title":"Mol. Syst. Des. Eng."},{"issue":"12","key":"10.1016\/j.jmbbm.2023.106084_b59","doi-asserted-by":"crossref","first-page":"1824","DOI":"10.1016\/j.joca.2013.08.024","article-title":"The clinical status of cartilage tissue regeneration in humans","volume":"21","author":"Mollon","year":"2013","journal-title":"Osteoarthritis Cartilage"},{"issue":"1","key":"10.1016\/j.jmbbm.2023.106084_b60","doi-asserted-by":"crossref","first-page":"99","DOI":"10.1016\/j.joca.2016.09.018","article-title":"Tribological rehydration of cartilage and its potential role in preserving joint health","volume":"25","author":"Moore","year":"2017","journal-title":"Osteoarthr. Cartil."},{"issue":"4","key":"10.1016\/j.jmbbm.2023.106084_b61","doi-asserted-by":"crossref","first-page":"202","DOI":"10.1080\/17515831.2017.1397329","article-title":"A review of methods to study hydration effects on cartilage friction","volume":"11","author":"Moore","year":"2017","journal-title":"Tribol.-Mater., Surf. Interfaces"},{"issue":"1","key":"10.1016\/j.jmbbm.2023.106084_b62","doi-asserted-by":"crossref","first-page":"73","DOI":"10.1115\/1.3138202","article-title":"Biphasic creep and stress relaxation of articular cartilage in compression: Theory and experiments","volume":"102","author":"Mow","year":"1980","journal-title":"J. Biomech. Eng."},{"key":"10.1016\/j.jmbbm.2023.106084_b63","series-title":"Highly durable lubricity of photo-cross-linked zwitterionic polymer brushes supported by poly(ether ether ketone) substrate","author":"Nakano","year":"2020"},{"issue":"7","key":"10.1016\/j.jmbbm.2023.106084_b64","doi-asserted-by":"crossref","first-page":"834","DOI":"10.1016\/j.clinbiomech.2007.03.008","article-title":"A multi-directional in vitro investigation into friction, damage and wear of innovative chondroplasty materials against articular cartilage","volume":"22","author":"Northwood","year":"2007","journal-title":"Clin. Biomech."},{"issue":"1","key":"10.1016\/j.jmbbm.2023.106084_b65","doi-asserted-by":"crossref","first-page":"96","DOI":"10.1016\/j.medengphy.2010.09.009","article-title":"Fluid load support and contact mechanics of hemiarthroplasty in the natural hip joint","volume":"33","author":"Pawaskar","year":"2011","journal-title":"Med. Eng. Phys."},{"issue":"9\u201310","key":"10.1016\/j.jmbbm.2023.106084_b66","doi-asserted-by":"crossref","first-page":"1745","DOI":"10.1016\/j.wear.2010.12.084","article-title":"The relationship between friction and wettability in aqueous environment","volume":"271","author":"Pawlak","year":"2011","journal-title":"Wear"},{"issue":"3","key":"10.1016\/j.jmbbm.2023.106084_b67","doi-asserted-by":"crossref","first-page":"217","DOI":"10.1136\/ard.41.3.217","article-title":"Modes of lubrication in human hip joints","volume":"41","author":"Roberts","year":"1982","journal-title":"Ann. Rheum. Dis."},{"issue":"4","key":"10.1016\/j.jmbbm.2023.106084_b68","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1007\/s40735-016-0053-0","article-title":"Advances in bio-inspired tribology for engineering applications","volume":"2","author":"Siddaiah","year":"2016","journal-title":"J. Bio- Tribo-Corrosion"},{"issue":"6","key":"10.1016\/j.jmbbm.2023.106084_b69","doi-asserted-by":"crossref","first-page":"461","DOI":"10.1177\/1941738109350438","article-title":"The basic science of articular cartilage: Structure, composition, and function","volume":"1","author":"Sophia Fox","year":"2009","journal-title":"Sports Health"},{"issue":"6","key":"10.1016\/j.jmbbm.2023.106084_b70","doi-asserted-by":"crossref","first-page":"435","DOI":"10.1016\/j.mporth.2010.08.002","article-title":"Tribology of artificial joints","volume":"24","author":"Stewart","year":"2010","journal-title":"Orthop. Trauma"},{"key":"10.1016\/j.jmbbm.2023.106084_b71","doi-asserted-by":"crossref","first-page":"597","DOI":"10.1016\/j.actbio.2019.06.015","article-title":"Tribocorrosion of a CoCrMo alloy sliding against articular cartilage and the impact of metal ion release on chondrocytes","volume":"94","author":"Stojanovi\u0107","year":"2019","journal-title":"Acta Biomater."},{"issue":"5","key":"10.1016\/j.jmbbm.2023.106084_b72","doi-asserted-by":"crossref","first-page":"329","DOI":"10.1016\/0021-9290(85)90288-X","article-title":"Elbow joint contact study: Comparison of techniques","volume":"18","author":"Stormont","year":"1985","journal-title":"J. Biomech."},{"key":"10.1016\/j.jmbbm.2023.106084_b73","doi-asserted-by":"crossref","DOI":"10.1016\/j.jmbbm.2022.105528","article-title":"Minimum design requirements for a poroelastic mimic of articular cartilage","volume":"137","author":"Tan","year":"2023","journal-title":"J. Mech. Behav. Biomed. Mater."},{"key":"10.1016\/j.jmbbm.2023.106084_b74","doi-asserted-by":"crossref","first-page":"277","DOI":"10.1136\/ard.34.4.277","article-title":"Some new evidence on human joint lubrication","volume":"34","author":"Unsworth","year":"1975","journal-title":"Ann. Rheumatic Dis."},{"issue":"3","key":"10.1016\/j.jmbbm.2023.106084_b75","doi-asserted-by":"crossref","first-page":"261","DOI":"10.1038\/s41592-019-0686-2","article-title":"Scipy 1.0: Fundamental algorithms for scientific computing in Python","volume":"17","author":"Virtanen","year":"2020","journal-title":"Nat. methods"},{"key":"10.1016\/j.jmbbm.2023.106084_b76","doi-asserted-by":"crossref","first-page":"390","DOI":"10.1016\/j.actbio.2021.11.014","article-title":"The modes and competing rates of cartilage fluid loss and recovery","volume":"138","author":"Voinier","year":"2022","journal-title":"Acta Biomater."},{"issue":"15","key":"10.1016\/j.jmbbm.2023.106084_b77","doi-asserted-by":"crossref","first-page":"4037","DOI":"10.1016\/j.jbiomech.2015.09.047","article-title":"Contact mechanics of reverse engineered distal humeral hemiarthroplasty implants","volume":"48","author":"Willing","year":"2015","journal-title":"J. Biomech."},{"issue":"5","key":"10.1016\/j.jmbbm.2023.106084_b78","doi-asserted-by":"crossref","first-page":"1693","DOI":"10.1529\/biophysj.106.088799","article-title":"Adsorption, lubrication, and wear of lubricin on model surfaces: Polymer brush-like behavior of a glycoprotein","volume":"92","author":"Zappone","year":"2007","journal-title":"Biophys. J."}],"container-title":["Journal of the Mechanical Behavior of Biomedical Materials"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S175161612300437X?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S175161612300437X?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,28]],"date-time":"2025-10-28T22:55:08Z","timestamp":1761692108000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S175161612300437X"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,11]]},"references-count":78,"alternative-id":["S175161612300437X"],"URL":"https:\/\/doi.org\/10.1016\/j.jmbbm.2023.106084","relation":{},"ISSN":["1751-6161"],"issn-type":[{"value":"1751-6161","type":"print"}],"subject":[],"published":{"date-parts":[[2023,11]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Highly lubricious SPMK-g-PEEK implant surfaces to facilitate rehydration of articular cartilage","name":"articletitle","label":"Article Title"},{"value":"Journal of the Mechanical Behavior of Biomedical Materials","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jmbbm.2023.106084","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2023 The Authors. Published by Elsevier Ltd.","name":"copyright","label":"Copyright"}],"article-number":"106084"}}