{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,31]],"date-time":"2026-07-31T20:50:33Z","timestamp":1785531033765,"version":"3.56.0"},"reference-count":28,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2024,12,1]],"date-time":"2024-12-01T00:00:00Z","timestamp":1733011200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2024,12,1]],"date-time":"2024-12-01T00:00:00Z","timestamp":1733011200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2024,12,1]],"date-time":"2024-12-01T00:00:00Z","timestamp":1733011200000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-017"},{"start":{"date-parts":[[2024,12,1]],"date-time":"2024-12-01T00:00:00Z","timestamp":1733011200000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-037"},{"start":{"date-parts":[[2024,12,1]],"date-time":"2024-12-01T00:00:00Z","timestamp":1733011200000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-012"},{"start":{"date-parts":[[2024,12,1]],"date-time":"2024-12-01T00:00:00Z","timestamp":1733011200000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-029"},{"start":{"date-parts":[[2024,12,1]],"date-time":"2024-12-01T00:00:00Z","timestamp":1733011200000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-004"}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of the Mechanical Behavior of Biomedical Materials"],"published-print":{"date-parts":[[2024,12]]},"DOI":"10.1016\/j.jmbbm.2024.106789","type":"journal-article","created":{"date-parts":[[2024,10,28]],"date-time":"2024-10-28T17:21:37Z","timestamp":1730136097000},"page":"106789","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":8,"special_numbering":"C","title":["Comparison of tendon attachment to 3D printed Ti6Al4V implant versus Trevira\u00ae implant: A paired experimental animal study"],"prefix":"10.1016","volume":"160","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-9471-296X","authenticated-orcid":false,"given":"Sarah S.","family":"Freund","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anna B.","family":"Borgognoni","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael M.","family":"Bendtsen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0000-3828-3796","authenticated-orcid":false,"given":"J\u00f8rgen","family":"Baas","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jeppe S.","family":"Byskov","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0919-5145","authenticated-orcid":false,"given":"Bahram","family":"Ranjkesh","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Steen","family":"B\u00e6rentzen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8084-4646","authenticated-orcid":false,"given":"Jens R.","family":"Nyengaard","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thomas","family":"Baad-Hansen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"issue":"2","key":"10.1016\/j.jmbbm.2024.106789_bib1","doi-asserted-by":"crossref","first-page":"155","DOI":"10.3109\/17453674.2011.572251","article-title":"Comparison of trabecular metal cups and titanium fiber-mesh cups in primary hip arthroplasty","volume":"82","author":"Baad-Hansen","year":"2011","journal-title":"Acta Orthop."},{"issue":"7","key":"10.1016\/j.jmbbm.2024.106789_bib2","doi-asserted-by":"crossref","first-page":"856","DOI":"10.1054\/arth.2001.25502","article-title":"Reconstruction of the extensor mechanism after proximal tibia endoprosthetic replacement","volume":"16","author":"Bickels","year":"2001","journal-title":"J. Arthroplasty"},{"issue":"8","key":"10.1016\/j.jmbbm.2024.106789_bib3","doi-asserted-by":"crossref","first-page":"592","DOI":"10.1016\/S0268-0033(00)00021-8","article-title":"Gait and electromyographic analysis of patients recovering after limb-saving surgery","volume":"15","author":"De Visser","year":"2000","journal-title":"Clin. BioMech."},{"issue":"1","key":"10.1016\/j.jmbbm.2024.106789_bib4","doi-asserted-by":"crossref","DOI":"10.1038\/s41598-020-80299-w","article-title":"Effect of storage and preconditioning of healing rat Achilles tendon on structural and mechanical properties","volume":"11","author":"Dietrich-Zagonel","year":"2021","journal-title":"Sci. Rep."},{"issue":"8","key":"10.1016\/j.jmbbm.2024.106789_bib5","doi-asserted-by":"crossref","first-page":"1156","DOI":"10.1302\/0301-620X.83B8.0831156","article-title":"Modular prosthetic replacement of the proximal femur after resection of a bone tumour a long-term follow-up","volume":"83","author":"Donati","year":"2001","journal-title":"J. Bone Joint Surg."},{"issue":"4 Suppl. 1","key":"10.1016\/j.jmbbm.2024.106789_bib6","first-page":"37","article-title":"Soft tissue adhesion patterns over Trevira tube on modular endoprosthesis for malignant bone tumours: an in vitro study","volume":"31","author":"D\u2019Adamio","year":"2017","journal-title":"J. Biol. Regul. Homeost. Agents"},{"issue":"1","key":"10.1016\/j.jmbbm.2024.106789_bib7","doi-asserted-by":"crossref","DOI":"10.1088\/1748-6041\/6\/1\/015007","article-title":"The effect of pore size on tissue ingrowth and neovascularization in porous bioceramics of controlled architecture in vivo","volume":"6","author":"Feng","year":"2011","journal-title":"Biomed. Mater."},{"issue":"393","key":"10.1016\/j.jmbbm.2024.106789_bib8","doi-asserted-by":"crossref","first-page":"264","DOI":"10.1097\/00003086-200112000-00030","article-title":"Soft tissue reconstruction of megaprostheses using a trevira tube","volume":"393","author":"Gosheger","year":"2001","journal-title":"Clin. Orthop. Relat. Res."},{"issue":"1","key":"10.1016\/j.jmbbm.2024.106789_bib9","doi-asserted-by":"crossref","DOI":"10.1186\/s13018-022-02960-6","article-title":"3D-printed porous Ti6Al4V scaffolds for long bone repair in animal models: a systematic review","volume":"17","author":"Gu","year":"2022","journal-title":"J. Orthop. Surg. Res."},{"issue":"5","key":"10.1016\/j.jmbbm.2024.106789_bib10","doi-asserted-by":"crossref","first-page":"379","DOI":"10.1111\/j.1699-0463.1988.tb05320.x","article-title":"Some new, simple and efficient stereological methods and their use in pathological research and diagnosis","volume":"96","author":"Gundersen","year":"1988","journal-title":"Apmis"},{"key":"10.1016\/j.jmbbm.2024.106789_bib11","doi-asserted-by":"crossref","DOI":"10.1155\/2022\/2801229","article-title":"Effect of pore size of porous-structured titanium implants on tendon ingrowth","volume":"2022","author":"Guo","year":"2022","journal-title":"Appl. Bionics Biomech."},{"issue":"11","key":"10.1016\/j.jmbbm.2024.106789_bib12","doi-asserted-by":"crossref","first-page":"3041","DOI":"10.1007\/s11999-012-2382-8","article-title":"Tantalum acetabular cups provide secure fixation in THA after pelvic irradiation at minimum 5-year followup","volume":"470","author":"Joglekar","year":"2012","journal-title":"Clin. Orthop. Relat. Res."},{"issue":"8","key":"10.1016\/j.jmbbm.2024.106789_bib13","doi-asserted-by":"crossref","first-page":"1193","DOI":"10.1002\/jor.21373","article-title":"The effects of multiple freeze\u2013thaw cycles on the biomechanical properties of the human bone\u2010patellar tendon\u2010bone allograft","volume":"29","author":"Jung","year":"2011","journal-title":"J. Orthop. Res."},{"issue":"1","key":"10.1016\/j.jmbbm.2024.106789_bib14","doi-asserted-by":"crossref","first-page":"47","DOI":"10.1007\/BF01552654","article-title":"Measurement of stress-strain relationship and stress relaxation in various synthetic ligaments","volume":"2","author":"Kdolsky","year":"1994","journal-title":"Knee Surg. Sports Traumatol. Arthrosc."},{"issue":"10","key":"10.1016\/j.jmbbm.2024.106789_bib15","doi-asserted-by":"crossref","first-page":"3861","DOI":"10.3390\/ma16103861","article-title":"Comparative analysis of bone ingrowth in 3D-printed titanium lattice structures with different patterns","volume":"16","author":"Kov\u00e1cs","year":"2023","journal-title":"Materials"},{"key":"10.1016\/j.jmbbm.2024.106789_bib16","series-title":"Comprehensive Materials Processing","first-page":"93","article-title":"10.05 - selective laser sintering\/melting","author":"Kumar","year":"2014"},{"issue":"1","key":"10.1016\/j.jmbbm.2024.106789_bib17","doi-asserted-by":"crossref","DOI":"10.1186\/s12913-023-10511-w","article-title":"First experiences of a hospital-based 3D printing facility \u2013 an analytical observational study","volume":"24","author":"Kveller","year":"2024","journal-title":"BMC Health Serv. Res."},{"issue":"3","key":"10.1016\/j.jmbbm.2024.106789_bib18","doi-asserted-by":"crossref","first-page":"1709","DOI":"10.3390\/ma7031709","article-title":"New developments of Ti-based alloys for biomedical applications","volume":"7","author":"Li","year":"2014","journal-title":"Materials"},{"issue":"10","key":"10.1016\/j.jmbbm.2024.106789_bib19","doi-asserted-by":"crossref","DOI":"10.3390\/bioengineering9100504","article-title":"Mechanical characterisation and numerical modelling of TPMS-based gyroid and diamond Ti6Al4V scaffolds for bone implants: an integrated approach for translational consideration","volume":"9","author":"Naghavi","year":"2022","journal-title":"Bioengineering"},{"issue":"4","key":"10.1016\/j.jmbbm.2024.106789_bib20","doi-asserted-by":"crossref","first-page":"371","DOI":"10.1007\/s00776-008-1242-6","article-title":"Effect of eccentric exercise on the healing process of injured patellar tendon in rats","volume":"13","author":"Nakamura","year":"2008","journal-title":"J. Orthop. Sci."},{"issue":"7","key":"10.1016\/j.jmbbm.2024.106789_bib21","article-title":"The ARRIVE guidelines 2.0: updated guidelines for reporting animal research","volume":"18","author":"Percie Du Sert","year":"2020","journal-title":"PLoS Biol."},{"issue":"3","key":"10.1016\/j.jmbbm.2024.106789_bib22","doi-asserted-by":"crossref","first-page":"489","DOI":"10.1038\/jcbfm.2011.151","article-title":"How stereological analysis of vascular morphology can quantify the blood volume fraction as a marker for tumor vasculature: comparison with magnetic resonance imaging","volume":"32","author":"Perles-Barbacaru","year":"2012","journal-title":"J. Cerebr. Blood Flow Metabol."},{"issue":"3","key":"10.1016\/j.jmbbm.2024.106789_bib23","first-page":"314","article-title":"Pull-out bond strength of titanium post cemented with novel fast-setting calcium silicate cement","volume":"6","author":"Ranjkesh","year":"2021","journal-title":"Eur Endod J"},{"issue":"4","key":"10.1016\/j.jmbbm.2024.106789_bib24","doi-asserted-by":"crossref","first-page":"439","DOI":"10.1080\/00016470216319","article-title":"Gait and function in patients with a femoral endoprosthesis after tumor resection","volume":"73","author":"Rompen","year":"2002","journal-title":"Acta Orthop. Scand."},{"issue":"1","key":"10.1016\/j.jmbbm.2024.106789_bib25","article-title":"Load and failure behavior of human muscle samples in the context of proximal femur replacement","volume":"17","author":"Schleifenbaum","year":"2016","journal-title":"BMC Muscoskel. Disord."},{"issue":"9","key":"10.1016\/j.jmbbm.2024.106789_bib28","doi-asserted-by":"crossref","first-page":"5671","DOI":"10.3390\/ma8095269","article-title":"Macrophages, foreign body giant Cells and their response to implantable biomaterials","volume":"8","author":"Sheikh","year":"2015","journal-title":"Materials"},{"issue":"5","key":"10.1016\/j.jmbbm.2024.106789_bib26","doi-asserted-by":"crossref","first-page":"399","DOI":"10.1016\/0021-9290(86)90016-3","article-title":"Effects of postmortem storage by freezing on ligament tensile behavior","volume":"19","author":"Woo","year":"1986","journal-title":"J. Biomech."},{"key":"10.1016\/j.jmbbm.2024.106789_bib27","series-title":"Promotion of Tendon Growth into Implant through Pore-Size Design of a Ti-6Al-4 V Porous Scaffold Prepared by 3D Printing","author":"Zheng","year":"2020"}],"container-title":["Journal of the Mechanical Behavior of Biomedical Materials"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1751616124004211?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1751616124004211?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2024,11,10]],"date-time":"2024-11-10T16:18:39Z","timestamp":1731255519000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1751616124004211"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,12]]},"references-count":28,"alternative-id":["S1751616124004211"],"URL":"https:\/\/doi.org\/10.1016\/j.jmbbm.2024.106789","relation":{},"ISSN":["1751-6161"],"issn-type":[{"value":"1751-6161","type":"print"}],"subject":[],"published":{"date-parts":[[2024,12]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Comparison of tendon attachment to 3D printed Ti6Al4V implant versus Trevira\u00ae implant: A paired experimental animal study","name":"articletitle","label":"Article Title"},{"value":"Journal of the Mechanical Behavior of Biomedical Materials","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jmbbm.2024.106789","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2024 Published by Elsevier Ltd.","name":"copyright","label":"Copyright"}],"article-number":"106789"}}