{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,2]],"date-time":"2026-06-02T01:22:32Z","timestamp":1780363352982,"version":"3.54.1"},"reference-count":18,"publisher":"Elsevier BV","issue":"6","license":[{"start":{"date-parts":[[2014,11,1]],"date-time":"2014-11-01T00:00:00Z","timestamp":1414800000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":["jmig.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Minimally Invasive Gynecology"],"published-print":{"date-parts":[[2014,11]]},"DOI":"10.1016\/j.jmig.2014.05.004","type":"journal-article","created":{"date-parts":[[2014,5,22]],"date-time":"2014-05-22T07:46:56Z","timestamp":1400744816000},"page":"1103-1109","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":13,"title":["Greater Surgical Precision of a Flexible Carbon Dioxide Laser Fiber Compared to Monopolar Electrosurgery in Porcine Myometrium"],"prefix":"10.1016","volume":"21","author":[{"given":"Amelia P.","family":"Bailey","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Luca","family":"Lancerotto","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chad","family":"Gridley","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dennis P.","family":"Orgill","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hiep","family":"Nguyen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Elena","family":"Pescarini","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gianluigi","family":"Lago","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Antonio R.","family":"Gargiulo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.jmig.2014.05.004_bib1","series-title":"Lasers in Gynecology","author":"McLaughlin","year":"1991"},{"key":"10.1016\/j.jmig.2014.05.004_bib2","doi-asserted-by":"crossref","first-page":"434","DOI":"10.3171\/2009.7.JNS09356","article-title":"Application of a flexible CO2 laser fiber for neurosurgery: laser-tissue interactions","volume":"112","author":"Ryan","year":"2010","journal-title":"J Neurosurg"},{"key":"10.1016\/j.jmig.2014.05.004_bib3","doi-asserted-by":"crossref","first-page":"1025","DOI":"10.1016\/S0015-0282(16)59603-4","article-title":"A comparison of thermal energy, healing patterns, and postoperative adhesion formation following CO2 laser and electromicrosurgery","volume":"48","author":"Luciano","year":"1987","journal-title":"Fertil Steril"},{"key":"10.1016\/j.jmig.2014.05.004_bib4","first-page":"1350","article-title":"Results of electron microscopy studies of the uterine horn of New Zealand rabbit following use of 4 different coagulation methods [in German]","volume":"109","author":"Riedel","year":"1987","journal-title":"Zentralbl Gynakol"},{"key":"10.1016\/j.jmig.2014.05.004_bib5","doi-asserted-by":"crossref","first-page":"806","DOI":"10.1016\/S0015-0282(00)01785-4","article-title":"Gross and histologic characteristics of laparoscopic injuries with four different energy sources","volume":"75","author":"Tulikangas","year":"2001","journal-title":"Fertil Steril"},{"key":"10.1016\/j.jmig.2014.05.004_bib6","doi-asserted-by":"crossref","first-page":"95","DOI":"10.1002\/micr.1920130209","article-title":"Fertility and histology after rabbit ovarian wedge resection with CO2 laser or electrocautery using posterior reconstruction with nylon or polyglactin sutures","volume":"13","author":"Arnau Rivera","year":"1992","journal-title":"Microsurgery"},{"key":"10.1016\/j.jmig.2014.05.004_bib7","doi-asserted-by":"crossref","first-page":"327","DOI":"10.1016\/S0002-9378(84)80078-2","article-title":"Carbon dioxide laser and electrosurgical wound study with an animal model: a comparison of tissue damage and healing patterns in peritoneal tissue","volume":"148","author":"Bellina","year":"1984","journal-title":"Am J Obstet Gynecol"},{"key":"10.1016\/j.jmig.2014.05.004_bib8","doi-asserted-by":"crossref","first-page":"717","DOI":"10.1016\/S0015-0282(16)48196-3","article-title":"Tubal patency and pelvic adhesions at early second-look laparoscopy following intraabdominal use of the carbon dioxide laser: initial report of the intraabdominal laser study group","volume":"42","author":"Diamond","year":"1984","journal-title":"Fertil Steril"},{"key":"10.1016\/j.jmig.2014.05.004_bib9","doi-asserted-by":"crossref","first-page":"407","DOI":"10.1016\/S0015-0282(16)49226-5","article-title":"The effectiveness of CO2 laser and electromicrosurgery in adhesiolysis: a comparative study","volume":"45","author":"Filmar","year":"1986","journal-title":"Fertil Steril"},{"key":"10.1016\/j.jmig.2014.05.004_bib10","doi-asserted-by":"crossref","first-page":"366","DOI":"10.1016\/S0015-0282(16)47301-2","article-title":"A comparison of the CO2 laser and electrocautery on postoperative intraperitoneal adhesion formation in rabbits","volume":"40","author":"Pittaway","year":"1983","journal-title":"Fertil Steril"},{"key":"10.1016\/j.jmig.2014.05.004_bib11","doi-asserted-by":"crossref","first-page":"704","DOI":"10.1016\/S0015-0282(16)59127-4","article-title":"Adhesion reformation after reproductive surgery with and without the carbon dioxide laser","volume":"47","author":"Tulandi","year":"1987","journal-title":"Fertil Steril"},{"key":"10.1016\/j.jmig.2014.05.004_bib12","first-page":"433","article-title":"Incidence of postoperative adhesions following use of various methods of coagulation: an animal experiment study [in German]","volume":"110","author":"Mecke","year":"1988","journal-title":"Zentralbl Gynakol"},{"key":"10.1016\/j.jmig.2014.05.004_bib13","doi-asserted-by":"crossref","first-page":"489","DOI":"10.1016\/S0015-0282(16)49274-5","article-title":"Salpingo-ovariolysis: a comparison between laser surgery and electrosurgery","volume":"45","author":"Tulandi","year":"1986","journal-title":"Fertil Steril"},{"key":"10.1016\/j.jmig.2014.05.004_bib14","doi-asserted-by":"crossref","first-page":"231","DOI":"10.1097\/AOG.0b013e3181af36e3","article-title":"Incidence and characteristics of patients with vaginal cuff dehiscence after robotic procedures","volume":"114","author":"Kho","year":"2009","journal-title":"Obstet Gynecol"},{"key":"10.1016\/j.jmig.2014.05.004_bib15","doi-asserted-by":"crossref","first-page":"311","DOI":"10.1016\/j.jmig.2006.11.005","article-title":"Incidence and patient characteristics of vaginal cuff dehiscence after different modes of hysterectomies","volume":"14","author":"Hur","year":"2007","journal-title":"J Minim Invasive Gynecol"},{"key":"10.1016\/j.jmig.2014.05.004_bib16","doi-asserted-by":"crossref","first-page":"551","DOI":"10.1016\/j.jmig.2010.04.015","article-title":"Risk factors for uterine rupture after laparoscopic myomectomy","volume":"17","author":"Parker","year":"2010","journal-title":"J Minim Invasive Gynecol"},{"key":"10.1016\/j.jmig.2014.05.004_bib17","doi-asserted-by":"crossref","first-page":"494.e1","DOI":"10.1016\/j.ajog.2011.07.009","article-title":"Laparoscopic hysterectomy using various energy sources in swine: a histopathologic assessment","volume":"205","author":"Gruber","year":"2011","journal-title":"Am J Obstet Gynecol"},{"key":"10.1016\/j.jmig.2014.05.004_bib18","doi-asserted-by":"crossref","first-page":"66","DOI":"10.1046\/j.1524-475x.2001.00066.x","article-title":"The pig as a model for human wound healing","volume":"9","author":"Sullivan","year":"2001","journal-title":"Wound Repair Regen"}],"container-title":["Journal of Minimally Invasive Gynecology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1553465014002908?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1553465014002908?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2018,10,4]],"date-time":"2018-10-04T01:25:51Z","timestamp":1538616351000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1553465014002908"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,11]]},"references-count":18,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2014,11]]}},"alternative-id":["S1553465014002908"],"URL":"https:\/\/doi.org\/10.1016\/j.jmig.2014.05.004","relation":{},"ISSN":["1553-4650"],"issn-type":[{"value":"1553-4650","type":"print"}],"subject":[],"published":{"date-parts":[[2014,11]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Greater Surgical Precision of a Flexible Carbon Dioxide Laser Fiber Compared to Monopolar Electrosurgery in Porcine Myometrium","name":"articletitle","label":"Article Title"},{"value":"Journal of Minimally Invasive Gynecology","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jmig.2014.05.004","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2014 AAGL. Published by Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}