{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,2]],"date-time":"2026-06-02T02:06:58Z","timestamp":1780366018143,"version":"3.54.1"},"reference-count":16,"publisher":"Elsevier BV","issue":"7","license":[{"start":{"date-parts":[[2017,11,1]],"date-time":"2017-11-01T00:00:00Z","timestamp":1509494400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"funder":[{"name":"NIH","award":["P30 CA008748"],"award-info":[{"award-number":["P30 CA008748"]}]},{"name":"NCI"}],"content-domain":{"domain":["clinicalkey.jp","clinicalkey.com","clinicalkey.es","clinicalkey.fr","clinicalkey.com.au","jmig.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Minimally Invasive Gynecology"],"published-print":{"date-parts":[[2017,11]]},"DOI":"10.1016\/j.jmig.2017.04.009","type":"journal-article","created":{"date-parts":[[2017,4,28]],"date-time":"2017-04-28T20:02:42Z","timestamp":1493409762000},"page":"1229-1233","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":8,"title":["Bilateral Otorrhagia after Robotically Assisted Gynecologic Surgery in the Setting of a Reduced Trendelenburg Position and Low-Pressure Pneumoperitoneum: A Case Report and Review of the Literature"],"prefix":"10.1016","volume":"24","author":[{"given":"Alessia","family":"Aloisi","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Julianna E.","family":"Pesce","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sarah E.","family":"Paraghamian","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dennis S.","family":"Chi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Elizabeth F.","family":"Rieth","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.jmig.2017.04.009_bib1","doi-asserted-by":"crossref","first-page":"549","DOI":"10.1016\/S0750-7658(01)00420-8","article-title":"Postoperative otorrhagia: an unknown complication of Trendelenburg position during laparoscopic surgery","volume":"20","author":"Aunac","year":"2001","journal-title":"Ann Fr Anesth Reanim"},{"key":"10.1016\/j.jmig.2017.04.009_bib2","doi-asserted-by":"crossref","first-page":"627","DOI":"10.1111\/j.1365-2044.2005.04249.x","article-title":"Bilateral otorrhagia during emergence from anaesthesia","volume":"60","author":"D'souza","year":"2005","journal-title":"Anaesthesia"},{"key":"10.1016\/j.jmig.2017.04.009_bib3","doi-asserted-by":"crossref","first-page":"982","DOI":"10.1016\/j.athoracsur.2011.07.017","article-title":"Spontaneous ear hemorrhage during cardiac surgery","volume":"93","author":"Singh","year":"2012","journal-title":"Ann Thorac Surg"},{"key":"10.1016\/j.jmig.2017.04.009_bib4","doi-asserted-by":"crossref","DOI":"10.1136\/bcr-2014-206118","article-title":"Bilateral otorrhagia: a rare complication of laparoscopic abdominopelvic surgery","volume":"2014","author":"Addison","year":"2014","journal-title":"BMJ Case Rep"},{"key":"10.1016\/j.jmig.2017.04.009_bib5","doi-asserted-by":"crossref","first-page":"e6","DOI":"10.1097\/SPV.0000000000000088","article-title":"Intraoperative ear bleeding with bilateral otorrhagia during laparoscopic sacrocolpopexy","volume":"21","author":"Chan","year":"2015","journal-title":"Female Pelvic Med Reconstr Surg"},{"key":"10.1016\/j.jmig.2017.04.009_bib6","first-page":"7834","article-title":"Bloody otorrhea after robotically assisted laparoscopic prostatectomy","volume":"22","author":"Cohen","year":"2015","journal-title":"Can J Urol"},{"key":"10.1016\/j.jmig.2017.04.009_bib7","doi-asserted-by":"crossref","first-page":"91","DOI":"10.1213\/XAA.0000000000000185","article-title":"Bilateral Bloody otorrhagia after robotic-assisted laparoscopic prostatectomy","volume":"5","author":"Jones","year":"2015","journal-title":"A A Case Rep"},{"key":"10.1016\/j.jmig.2017.04.009_bib8","doi-asserted-by":"crossref","first-page":"70","DOI":"10.1089\/gyn.2015.0075","article-title":"Bilateral otorrhagia discovered at the completion of a robotic bilateral salpingo-oophorectomy","volume":"32","author":"Owens","year":"2016","journal-title":"J Gynecol Surg"},{"key":"10.1016\/j.jmig.2017.04.009_bib9","doi-asserted-by":"crossref","first-page":"112","DOI":"10.1016\/j.redar.2015.04.007","article-title":"Otorrhagia. A complication of laparoscopic hemicolectomy","volume":"63","author":"Espa\u00f1a Fuente","year":"2016","journal-title":"Rev Esp Anestesiol Reanim"},{"key":"10.1016\/j.jmig.2017.04.009_bib10","doi-asserted-by":"crossref","first-page":"833","DOI":"10.1152\/japplphysiol.00260.2002","article-title":"Syncope, cerebral perfusion, and oxygenation","volume":"94","author":"Van Lieshout","year":"2003","journal-title":"J Appl Physiol"},{"key":"10.1016\/j.jmig.2017.04.009_bib11","doi-asserted-by":"crossref","first-page":"1583","DOI":"10.1007\/s00464-016-5144-y","article-title":"Robotic partial nephrectomy performed with Airseal versus a standard CO(2) pressure pneumoperitoneum insufflator: a prospective comparative study","volume":"31","author":"Annino","year":"2017","journal-title":"Surg Endosc"},{"key":"10.1016\/j.jmig.2017.04.009_bib12","doi-asserted-by":"crossref","first-page":"801","DOI":"10.1089\/end.2014.0019","article-title":"Increase in intracranial pressure during carbon dioxide pneumoperitoneum with steep Trendelenburg positioning proven by ultrasonographic measurement of optic nerve sheath diameter","volume":"28","author":"Kim","year":"2014","journal-title":"J Endourol"},{"key":"10.1016\/j.jmig.2017.04.009_bib13","doi-asserted-by":"crossref","first-page":"1069","DOI":"10.1213\/ANE.0b013e3182075d1f","article-title":"Hemodynamic perturbations during robot-assisted laparoscopic radical prostatectomy in 45\u00b0 Trendelenburg position","volume":"113","author":"Lestar","year":"2011","journal-title":"Anesth Analg"},{"key":"10.1016\/j.jmig.2017.04.009_bib14","doi-asserted-by":"crossref","first-page":"737","DOI":"10.1097\/MAO.0000000000000604","article-title":"Effects of body tilt on multifrequency admittance tympanometry","volume":"36","author":"Franco-Vidal","year":"2015","journal-title":"Otol Neurotol"},{"key":"10.1016\/j.jmig.2017.04.009_bib15","doi-asserted-by":"crossref","first-page":"1126","DOI":"10.1016\/j.urology.2010.06.052","article-title":"Use of the valveless trocar system reduces carbon dioxide absorption during laparoscopy when compared with standard trocars","volume":"77","author":"Herati","year":"2011","journal-title":"Urology"},{"key":"10.1016\/j.jmig.2017.04.009_bib16","doi-asserted-by":"crossref","first-page":"1949","DOI":"10.1016\/j.jpedsurg.2016.09.016","article-title":"Pneumoperitoneum and hemodynamic stability during pediatric laparoscopic appendectomy","volume":"51","author":"Miyano","year":"2016","journal-title":"J Pediatr Surg"}],"container-title":["Journal of Minimally Invasive Gynecology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1553465017302650?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1553465017302650?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2018,9,2]],"date-time":"2018-09-02T07:55:20Z","timestamp":1535874920000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1553465017302650"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,11]]},"references-count":16,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2017,11]]}},"alternative-id":["S1553465017302650"],"URL":"https:\/\/doi.org\/10.1016\/j.jmig.2017.04.009","relation":{},"ISSN":["1553-4650"],"issn-type":[{"value":"1553-4650","type":"print"}],"subject":[],"published":{"date-parts":[[2017,11]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Bilateral Otorrhagia after Robotically Assisted Gynecologic Surgery in the Setting of a Reduced Trendelenburg Position and Low-Pressure Pneumoperitoneum: A Case Report and Review of the Literature","name":"articletitle","label":"Article Title"},{"value":"Journal of Minimally Invasive Gynecology","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jmig.2017.04.009","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2017 AAGL. All rights reserved.","name":"copyright","label":"Copyright"}]}}