{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,26]],"date-time":"2026-02-26T01:16:09Z","timestamp":1772068569493,"version":"3.50.1"},"reference-count":31,"publisher":"Elsevier BV","issue":"3","license":[{"start":{"date-parts":[[2021,9,1]],"date-time":"2021-09-01T00:00:00Z","timestamp":1630454400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":["clinicalkey.jp","clinicalkey.com","clinicalkey.es","jmirs.org","clinicalkey.com.au","clinicalkey.fr","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Medical Imaging and Radiation Sciences"],"published-print":{"date-parts":[[2021,9]]},"DOI":"10.1016\/j.jmir.2021.06.004","type":"journal-article","created":{"date-parts":[[2021,7,3]],"date-time":"2021-07-03T11:37:53Z","timestamp":1625312273000},"page":"409-416","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":5,"title":["Comparison of technical success and safety of transbronchial versus percutaneous CT-guided fiducial placement for SBRT of lung tumors"],"prefix":"10.1016","volume":"52","author":[{"given":"D.E.","family":"Moran","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"M.","family":"Parikh","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"R.G.","family":"Sheiman","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"O.R.","family":"Brook","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"M.R.M.","family":"Sun","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"A.","family":"Mahadevan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"B.","family":"Siewert","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"issue":"1-4 Pt 2","key":"10.1016\/j.jmir.2021.06.004_bib0001","doi-asserted-by":"crossref","first-page":"124","DOI":"10.1159\/000099863","article-title":"The Cyberknife: a frameless robotic system for radiosurgery","volume":"69","author":"Adler","year":"1997","journal-title":"Stereotact Funct Neurosurg"},{"issue":"7","key":"10.1016\/j.jmir.2021.06.004_bib0002","doi-asserted-by":"crossref","first-page":"859","DOI":"10.1016\/j.jvir.2009.03.037","article-title":"A primer on image-guided radiation therapy for the interventional radiologist","volume":"20","author":"Kothary","year":"2009","journal-title":"J Vasc Interv Radiol"},{"issue":"4","key":"10.1016\/j.jmir.2021.06.004_bib0003","doi-asserted-by":"crossref","first-page":"1090","DOI":"10.2214\/AJR.08.1399","article-title":"Percutaneous implantation of fiducial markers for imaging-guided radiation therapy","volume":"192","author":"Kothary","year":"2009","journal-title":"AJR Am J Roentgenol"},{"issue":"2","key":"10.1016\/j.jmir.2021.06.004_bib0004","doi-asserted-by":"crossref","first-page":"207","DOI":"10.1111\/j.1754-9485.2012.02445.x","article-title":"Planting the seeds of success: CT-guided gold seed fiducial marker placement to guide robotic radiosurgery","volume":"57","author":"Patel","year":"2013","journal-title":"J Med Imaging Radiat Oncol"},{"issue":"1","key":"10.1016\/j.jmir.2021.06.004_bib0005","doi-asserted-by":"crossref","first-page":"240","DOI":"10.1016\/S0360-3016(03)00076-2","article-title":"Feasibility of insertion\/implantation of 2.0-mm-diameter gold internal fiducial markers for precise setup and real-time tumor tracking in radiotherapy","volume":"56","author":"Shirato","year":"2003","journal-title":"Int J Radiat Oncol Biol Phys"},{"issue":"1","key":"10.1016\/j.jmir.2021.06.004_bib0006","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1016\/j.ijrobp.2010.04.037","article-title":"High retention and safety of percutaneously implanted endovascular embolization coils as fiducial markers for image-guided stereotactic ablative radiotherapy of pulmonary tumors","volume":"81","author":"Hong","year":"2011","journal-title":"Int J Radiat Oncol Biol Phys"},{"issue":"1","key":"10.1016\/j.jmir.2021.06.004_bib0007","doi-asserted-by":"crossref","first-page":"i61","DOI":"10.1093\/jrr\/rrt071","article-title":"Evaluation of different fiducial markers for image-guided radiotherapy and particle therapy","volume":"54","author":"Habermehl","year":"2013","journal-title":"J Radiat Res"},{"issue":"6","key":"10.1016\/j.jmir.2021.06.004_bib0008","doi-asserted-by":"crossref","first-page":"1186","DOI":"10.1007\/s00270-010-9949-0","article-title":"Complications associated with the percutaneous insertion of fiducial markers in the thorax","volume":"33","author":"Bhagat","year":"2010","journal-title":"Cardiovasc Intervent Radiol"},{"issue":"2","key":"10.1016\/j.jmir.2021.06.004_bib0009","doi-asserted-by":"crossref","first-page":"235","DOI":"10.1016\/j.jvir.2008.09.026","article-title":"Safety and efficacy of percutaneous fiducial marker implantation for image-guided radiation therapy","volume":"20","author":"Kothary","year":"2009","journal-title":"J Vasc Interv Radiol"},{"issue":"4","key":"10.1016\/j.jmir.2021.06.004_bib0010","doi-asserted-by":"crossref","first-page":"252","DOI":"10.3816\/CLC.2007.n.002","article-title":"Complications of thoracic computed tomography-guided fiducial placement for the purpose of stereotactic body radiation therapy","volume":"8","author":"Yousefi","year":"2007","journal-title":"Clin Lung Cancer"},{"issue":"5","key":"10.1016\/j.jmir.2021.06.004_bib0011","doi-asserted-by":"crossref","first-page":"760","DOI":"10.1016\/j.jvir.2014.01.004","article-title":"CT fluoroscopy-guided percutaneous fiducial marker placement for CyberKnife stereotactic radiosurgery: technical results and complications in 222 consecutive procedures","volume":"25","author":"Trumm","year":"2014","journal-title":"J Vasc Intervent Radiol"},{"key":"10.1016\/j.jmir.2021.06.004_bib0012","doi-asserted-by":"crossref","first-page":"368","DOI":"10.1016\/j.athoracsur.2009.09.048","article-title":"Fiducial marker placement using endobronchial ultrasound and navigational bronchoscopy for stereotactic radiosurgery: an alternative strategy","volume":"89","author":"Harley","year":"2010","journal-title":"Ann Thorac Surg"},{"issue":"4","key":"10.1016\/j.jmir.2021.06.004_bib0013","doi-asserted-by":"crossref","first-page":"271","DOI":"10.1097\/imi.0b013e31822c516f","article-title":"Use of navigation bronchoscopy for biopsy and endobronchial fiducial placement. Linden PA","volume":"6","author":"Linden","year":"2011","journal-title":"Innovations"},{"issue":"2","key":"10.1016\/j.jmir.2021.06.004_bib0014","doi-asserted-by":"crossref","first-page":"123","DOI":"10.1097\/LBR.0000000000000065","article-title":"Electromagnetic navigational bronchoscopy-guided fiducial markers for lung stereotactic body radiation therapy: analysis of safety, feasibility, and interfraction stability","volume":"21","author":"Nabavizadeh","year":"2014","journal-title":"J Bronchology Interv Pulmonol"},{"issue":"11","key":"10.1016\/j.jmir.2021.06.004_bib0015","doi-asserted-by":"crossref","first-page":"1070","DOI":"10.1001\/jama.2010.261","article-title":"Stereotactic body radiation therapy for inoperable early stage lung cancer","volume":"303","author":"Timmerman","year":"2010","journal-title":"JAMA"},{"issue":"1","key":"10.1016\/j.jmir.2021.06.004_bib0016","doi-asserted-by":"crossref","first-page":"59","DOI":"10.1097\/LBR.0b013e3180314694","article-title":"Real-time endobronchial ultrasound-guided implantation of radiotherapy monitoring devices","volume":"14","author":"McGuire","year":"2007","journal-title":"J Bronchol"},{"key":"10.1016\/j.jmir.2021.06.004_bib0017","doi-asserted-by":"crossref","first-page":"9","DOI":"10.3389\/fonc.2012.00009","article-title":"CyberKnife with tumor tracking: an effective treatment for high-risk surgical patients with stage I non-small cell lung cancer","volume":"2","author":"Chen","year":"2012","journal-title":"Front Oncol"},{"issue":"5","key":"10.1016\/j.jmir.2021.06.004_bib0018","doi-asserted-by":"crossref","first-page":"1820","DOI":"10.1016\/j.athoracsur.2006.11.077","article-title":"Stereotactic radiosurgery for the treatment of lung neoplasm: initial experience","volume":"83","author":"Pennathur","year":"2007","journal-title":"Ann Thorac Surg"},{"key":"10.1016\/j.jmir.2021.06.004_bib0019","doi-asserted-by":"crossref","first-page":"6","DOI":"10.1186\/1756-8722-3-6","article-title":"CyberKnife radiosurgery for inoperable stage IA non-small cell lung cancer: 18F-fluorodeoxyglucose positron emission tomography\/computed tomography serial tumor response assessment","volume":"3","author":"Vahdat","year":"2010","journal-title":"J Hematol Oncol"},{"issue":"6","key":"10.1016\/j.jmir.2021.06.004_bib0020","doi-asserted-by":"crossref","first-page":"630","DOI":"10.1016\/S1470-2045(15)70168-3","article-title":"Stereotactic ablative radiotherapy versus lobectomy for operable stage I non-small-cell lung cancer: a pooled analysis of two randomised trials","volume":"16","author":"Change","year":"2015","journal-title":"Lancet Oncol"},{"issue":"1","key":"10.1016\/j.jmir.2021.06.004_bib0021","doi-asserted-by":"crossref","first-page":"55","DOI":"10.1007\/s13566-014-0177-0","article-title":"Stereotactic body radiotherapy for early-stage non-small cell lung cancer: clinical outcomes from a National Patient Registry","volume":"4","author":"Davis","year":"2015","journal-title":"J Radiat Oncol"},{"key":"10.1016\/j.jmir.2021.06.004_bib0022","doi-asserted-by":"crossref","first-page":"146","DOI":"10.3389\/fonc.2015.00146","article-title":"Definitive treatment of early-stage non-small cell lung cancer with stereotactic ablative body radiotherapy in a community cancer center setting","volume":"5","author":"Heal","year":"2015","journal-title":"Front Oncol"},{"issue":"1","key":"10.1016\/j.jmir.2021.06.004_bib0023","doi-asserted-by":"crossref","first-page":"167","DOI":"10.1186\/s13014-019-1373-2","article-title":"Safety and efficacy of fiducial marker implantation for robotic stereotactic body radiation therapy with fiducial tracking","volume":"14","author":"Scher","year":"2019","journal-title":"Radiat Oncol"},{"key":"10.1016\/j.jmir.2021.06.004_bib0024","doi-asserted-by":"crossref","first-page":"324","DOI":"10.1097\/JTO.0000000000000389","article-title":"Multi-modality guidance for accurate bronchoscopic insertion of fiducial markers","volume":"10","author":"Steinfort","year":"2015","journal-title":"J Thorac Oncol"},{"key":"10.1016\/j.jmir.2021.06.004_bib0025","doi-asserted-by":"crossref","first-page":"193","DOI":"10.1097\/01.lab.0000186345.85025.41","article-title":"The placement of gold fiducials for Cyberknife stereotactic radiosurgery using a modified transbronchial needle aspiration technique","volume":"12","author":"Reichner","year":"2005","journal-title":"J Bronchol"},{"issue":"3","key":"10.1016\/j.jmir.2021.06.004_bib0026","doi-asserted-by":"crossref","first-page":"930","DOI":"10.1378\/chest.07-0522","article-title":"Electromagnetic navigation bronchoscopy-guided fiducial placement for robotic stereotactic radiosurgery of lung tumors: a feasibility study","volume":"132","author":"Anantham","year":"2007","journal-title":"Chest"},{"issue":"6","key":"10.1016\/j.jmir.2021.06.004_bib0027","doi-asserted-by":"crossref","first-page":"640","DOI":"10.1164\/rccm.201311-2007CI","article-title":"Endobronchial ultrasound-guided transbronchial needle aspiration for non-small cell lung cancer staging","volume":"189","author":"Kinsey","year":"2014","journal-title":"Am J Respir Crit Care Med"},{"key":"10.1016\/j.jmir.2021.06.004_bib0028","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1177\/1753466619841234","article-title":"Fiducial marker placement with electromagnetic navigation bronchoscopy: a subgroup analysis of the prospective, multicenter NAVIGATE study","volume":"13","author":"Bowling","year":"2019","journal-title":"Ther Adv Respir Dis"},{"issue":"2","key":"10.1016\/j.jmir.2021.06.004_bib0029","doi-asserted-by":"crossref","first-page":"121","DOI":"10.1055\/s-0033-1342952","article-title":"Percutaneous lung biopsy: technique, efficacy, and complications","volume":"30","author":"Winokur","year":"2013","journal-title":"Semin Intervent Radiol"},{"issue":"1","key":"10.1016\/j.jmir.2021.06.004_bib0030","doi-asserted-by":"crossref","first-page":"30","DOI":"10.1186\/1755-7682-4-30","article-title":"Anteroposterior chest radiograph vs. chest CT scan in early detection of pneumothorax in trauma patients","volume":"4","author":"Omar","year":"2011","journal-title":"Int Arch Med"},{"issue":"12","key":"10.1016\/j.jmir.2021.06.004_bib0031","doi-asserted-by":"crossref","first-page":"1901","DOI":"10.1016\/j.jvir.2019.04.025","article-title":"Endovascular coils as lung tumor fiducial markers for real-time tumor tracking in stereotactic body radiotherapy: comparison of complication rates with transthoracic fiducial marker placement","volume":"30","author":"Baker","year":"2019","journal-title":"J Vasc Interv Radiol"}],"container-title":["Journal of Medical Imaging and Radiation Sciences"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1939865421001314?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1939865421001314?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2021,10,20]],"date-time":"2021-10-20T07:43:56Z","timestamp":1634715836000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1939865421001314"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,9]]},"references-count":31,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2021,9]]}},"alternative-id":["S1939865421001314"],"URL":"https:\/\/doi.org\/10.1016\/j.jmir.2021.06.004","relation":{},"ISSN":["1939-8654"],"issn-type":[{"value":"1939-8654","type":"print"}],"subject":[],"published":{"date-parts":[[2021,9]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Comparison of technical success and safety of transbronchial versus percutaneous CT-guided fiducial placement for SBRT of lung tumors","name":"articletitle","label":"Article Title"},{"value":"Journal of Medical Imaging and Radiation Sciences","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jmir.2021.06.004","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2021 Published by Elsevier Inc. on behalf of Canadian Association of Medical Radiation Technologists.","name":"copyright","label":"Copyright"}]}}