{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,22]],"date-time":"2026-08-22T11:24:35Z","timestamp":1787397875916,"version":"build-2736575974"},"reference-count":19,"publisher":"Elsevier BV","issue":"5","license":[{"start":{"date-parts":[[2026,9,1]],"date-time":"2026-09-01T00:00:00Z","timestamp":1788220800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,9,1]],"date-time":"2026-09-01T00:00:00Z","timestamp":1788220800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2027,7,10]],"date-time":"2027-07-10T00:00:00Z","timestamp":1815177600000},"content-version":"am","delay-in-days":312,"URL":"http:\/\/www.elsevier.com\/open-access\/userlicense\/1.0\/"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","jmirs.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Medical Imaging and Radiation Sciences"],"published-print":{"date-parts":[[2026,9]]},"DOI":"10.1016\/j.jmir.2026.102491","type":"journal-article","created":{"date-parts":[[2026,7,10]],"date-time":"2026-07-10T00:26:11Z","timestamp":1783643171000},"page":"102491","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"title":["Geometric distortion in MRI for radiotherapy planning: A narrative review"],"prefix":"10.1016","volume":"57","author":[{"ORCID":"https:\/\/orcid.org\/0009-0005-9997-5151","authenticated-orcid":false,"given":"Masahiro","family":"Yuasa","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hiromasa","family":"Kurosaki","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"issue":"11","key":"10.1016\/j.jmir.2026.102491_bib0001","doi-asserted-by":"crossref","first-page":"1551","DOI":"10.1080\/0284186X.2023.2266560","article-title":"Geometric distortions in clinical MRI sequences for radiotherapy: insights gained from a multicenter investigation","volume":"62","author":"Hasler","year":"2023","journal-title":"Acta Oncol"},{"issue":"1","key":"10.1016\/j.jmir.2026.102491_bib0002","doi-asserted-by":"crossref","first-page":"39","DOI":"10.1007\/s00066-023-02120-7","article-title":"Impact of magnetic resonance imaging-related geometric distortion of dose distribution in fractionated stereotactic radiotherapy in patients with brain metastases","volume":"200","author":"Ohira","year":"2024","journal-title":"Strahlenther Onkol"},{"issue":"4","key":"10.1016\/j.jmir.2026.102491_bib0003","doi-asserted-by":"crossref","first-page":"477","DOI":"10.1016\/j.zemedi.2022.04.004","article-title":"Accuracy of MRI-CT registration in brain stereotactic radiotherapy: impact of MRI acquisition setup and registration method","volume":"32","author":"Masitho","year":"2022","journal-title":"Z Med Phys"},{"issue":"2","key":"10.1016\/j.jmir.2026.102491_bib0004","doi-asserted-by":"crossref","first-page":"388","DOI":"10.1118\/1.2402331","article-title":"Characterization, prediction, and correction of geometric distortion in 3 T MR images","volume":"34","author":"Baldwin","year":"2007","journal-title":"Med Phys"},{"key":"10.1016\/j.jmir.2026.102491_bib0005","doi-asserted-by":"crossref","first-page":"58","DOI":"10.1016\/j.phro.2021.01.003","article-title":"Determination of acceptance criteria for geometric accuracy of magnetic resonance imaging scanners used in radiotherapy planning","volume":"17","author":"Kavaluus","year":"2021","journal-title":"Phys Imaging Radiat Oncol"},{"issue":"11","key":"10.1016\/j.jmir.2026.102491_bib0006","doi-asserted-by":"crossref","first-page":"322","DOI":"10.1002\/acm2.13065","article-title":"Technical note: extended field-of-view (FOV) MRI distortion determination through multi-positional phantom imaging","volume":"21","author":"Sch\u00fcler","year":"2020","journal-title":"J Appl Clin Med Phys"},{"issue":"6","key":"10.1016\/j.jmir.2026.102491_bib0007","doi-asserted-by":"crossref","first-page":"606","DOI":"10.1016\/j.rpor.2019.09.011","article-title":"Evaluating the accuracy of geometrical distortion correction of magnetic resonance images for use in intracranial brain tumor radiotherapy","volume":"24","author":"Bagherimofidi","year":"2019","journal-title":"Rep Pr Oncol Radiother"},{"issue":"7","key":"10.1016\/j.jmir.2026.102491_bib0008","doi-asserted-by":"crossref","first-page":"e636","DOI":"10.1002\/mp.14695","article-title":"Task group 284 report: magnetic resonance imaging simulation in radiotherapy: considerations for clinical implementation, optimization, and quality assurance","volume":"48","author":"Glide-Hurst","year":"2021","journal-title":"Med Phys"},{"key":"10.1016\/j.jmir.2026.102491_bib0009","doi-asserted-by":"crossref","DOI":"10.1016\/j.radonc.2023.109504","article-title":"An ESTRO-ACROP guideline on quality assurance and medical physics commissioning of online MRI guided radiotherapy systems based on a consensus expert opinion","volume":"181","author":"Tanadini-Lang","year":"2023","journal-title":"Radiother Oncol"},{"issue":"2","key":"10.1016\/j.jmir.2026.102491_bib0010","doi-asserted-by":"crossref","first-page":"375","DOI":"10.1002\/mp.12068","article-title":"Stereotactic radiosurgery planning of vestibular schwannomas: is MRI at 3 tesla geometrically accurate?","volume":"44","author":"Schmidt","year":"2017","journal-title":"Med Phys"},{"issue":"4","key":"10.1016\/j.jmir.2026.102491_bib0011","doi-asserted-by":"crossref","first-page":"529","DOI":"10.1016\/j.mri.2004.01.008","article-title":"A novel phantom and method for comprehensive 3-dimensional measurement and correction of geometric distortion in magnetic resonance imaging","volume":"22","author":"Wang","year":"2004","journal-title":"Magn Reson Imaging"},{"key":"10.1016\/j.jmir.2026.102491_bib0012","article-title":"A comparison of the distortion in the same field MRI and MR-linac system with a 3D printed phantom","volume":"11","author":"Liu","year":"2021","journal-title":"Front Oncol"},{"issue":"6","key":"10.1016\/j.jmir.2026.102491_bib0013","doi-asserted-by":"crossref","first-page":"1120","DOI":"10.1177\/1533034617735454","article-title":"MRI-related geometric distortions in stereotactic radiotherapy treatment planning: evaluation and dosimetric impact","volume":"16","author":"Pappas","year":"2017","journal-title":"Technol Cancer Res Treat"},{"key":"10.1016\/j.jmir.2026.102491_bib0014","doi-asserted-by":"crossref","first-page":"212","DOI":"10.1016\/j.ejmp.2019.12.002","article-title":"Geometric inaccuracy and co-registration errors for CT, DynaCT and MRI images used in robotic stereotactic radiosurgery treatment planning","volume":"69","author":"Aldosary","year":"2020","journal-title":"Phys Med"},{"issue":"5","key":"10.1016\/j.jmir.2026.102491_bib0015","doi-asserted-by":"crossref","first-page":"645","DOI":"10.1016\/j.mri.2016.01.001","article-title":"Characterization of 3D geometric distortion of magnetic resonance imaging scanners commissioned for radiation therapy planning","volume":"34","author":"Torfeh","year":"2016","journal-title":"Magn Reson Imaging"},{"key":"10.1016\/j.jmir.2026.102491_bib0016","doi-asserted-by":"crossref","first-page":"100","DOI":"10.1016\/j.phro.2020.07.007","article-title":"Tumor-site specific geometric distortions in high field integrated magnetic resonance linear accelerator radiotherapy","volume":"15","author":"Hasler","year":"2020","journal-title":"Phys Imaging Radiat Oncol"},{"issue":"10","key":"10.1016\/j.jmir.2026.102491_bib0017","doi-asserted-by":"crossref","DOI":"10.1002\/acm2.70199","article-title":"Characterizing geometrical distortions in MRI for radiotherapy: evaluating MR-SIM protocols and dose accuracy in stereotactic radiosurgery using AAPM TG-284 criteria","volume":"26","author":"Barzegar","year":"2025","journal-title":"J Appl Clin Med Phys"},{"issue":"1","key":"10.1016\/j.jmir.2026.102491_bib0018","first-page":"29","article-title":"Evaluation of system-related magnetic resonance imaging geometric distortion in radiation therapy treatment planning: two approaches and effectiveness of three-dimensional distortion correction","volume":"84","author":"Kato","year":"2022","journal-title":"Nagoya J Med Sci"},{"key":"10.1016\/j.jmir.2026.102491_bib0019","doi-asserted-by":"crossref","first-page":"255","DOI":"10.1186\/s13244-024-01799-1","article-title":"The role of MRI in radiotherapy planning: a narrative review \u201cfrom head to toe\u201d","volume":"15","author":"De Pietro","year":"2024","journal-title":"Insights Imaging"}],"container-title":["Journal of Medical Imaging and Radiation Sciences"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S193986542600305X?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S193986542600305X?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,8,22]],"date-time":"2026-08-22T11:04:44Z","timestamp":1787396684000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S193986542600305X"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9]]},"references-count":19,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2026,9]]}},"alternative-id":["S193986542600305X"],"URL":"https:\/\/doi.org\/10.1016\/j.jmir.2026.102491","relation":{},"ISSN":["1939-8654"],"issn-type":[{"value":"1939-8654","type":"print"}],"subject":[],"published":{"date-parts":[[2026,9]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Geometric distortion in MRI for radiotherapy planning: A narrative review","name":"articletitle","label":"Article Title"},{"value":"Journal of Medical Imaging and Radiation Sciences","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jmir.2026.102491","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2026 Published by Elsevier Inc. on behalf of Canadian Association of Medical Radiation Technologists.","name":"copyright","label":"Copyright"}],"article-number":"102491"}}