{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T00:31:49Z","timestamp":1790728309181,"version":"4.1.0"},"reference-count":13,"publisher":"Stanford University Press","license":[{"start":{"date-parts":[[2025,8,1]],"date-time":"2025-08-01T00:00:00Z","timestamp":1754006400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2025,8,1]],"date-time":"2025-08-01T00:00:00Z","timestamp":1754006400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2025,7,9]],"date-time":"2025-07-09T00:00:00Z","timestamp":1752019200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Mass Spectrometry and Advances in the Clinical Lab"],"published-print":{"date-parts":[[2025,8]]},"DOI":"10.1016\/j.jmsacl.2025.07.001","type":"journal-article","created":{"date-parts":[[2025,7,15]],"date-time":"2025-07-15T22:52:25Z","timestamp":1752619945000},"page":"49-55","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":5,"special_numbering":"C","title":["Urine methamphetamine-to-amphetamine ratio by LC-MS\/MS to differentiate methamphetamine use from pharmaceutical impurity in patients prescribed amphetamine"],"prefix":"10.21627","volume":"37","author":[{"given":"Lindsey","family":"Contella","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Phillip","family":"Kang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Clara E.","family":"Wolf","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Victoria L.","family":"Thomas","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0358-0381","authenticated-orcid":false,"given":"Melissa","family":"Gildenberg","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marion L.","family":"Snyder","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4209-6085","authenticated-orcid":false,"given":"Stacy E.F.","family":"Melanson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7239-1843","authenticated-orcid":false,"given":"Nicole V.","family":"Tolan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"4811","reference":[{"key":"10.1016\/j.jmsacl.2025.07.001_b0005","doi-asserted-by":"crossref","first-page":"479","DOI":"10.1177\/0269881113482532","article-title":"AMPH, past and present\u2013a pharmacological and clinical perspective","volume":"27","author":"Heal","year":"2013","journal-title":"Psychopharmacol"},{"key":"10.1016\/j.jmsacl.2025.07.001_b0010","series-title":"Disposition of Toxic Drugs and Chemicals in Man","author":"Baselt","year":"2017"},{"key":"10.1016\/j.jmsacl.2025.07.001_b0015","article-title":"STARD 2015: an updated list of essential items for reporting diagnostic accuracy studies","volume":"351","author":"Bossuyt","year":"2015","journal-title":"BMJ"},{"key":"10.1016\/j.jmsacl.2025.07.001_b0020","doi-asserted-by":"crossref","first-page":"283","DOI":"10.1007\/s11606-019-05514-5","article-title":"Provider misinterpretation, documentation and follow up of definitive urine drug testing results","volume":"35","author":"Chua","year":"2020","journal-title":"J. Gen. Int. Med."},{"key":"10.1016\/j.jmsacl.2025.07.001_b0025","doi-asserted-by":"crossref","first-page":"974","DOI":"10.1373\/jalm.2018.027342","article-title":"A rapid dilute-and-shoot UPLC-MS\/MS assay to simultaneously measure 37 drugs and related metabolites in human urine for use in clinical pain management","volume":"3","author":"Dahlin","year":"2019","journal-title":"J. Appl. Lab. Med."},{"key":"10.1016\/j.jmsacl.2025.07.001_b0030","unstructured":"S. Fleming, L. Wolfe, J. Meeker, Expanded evaluation of patients prescribed Adderall and Vyanse for the presence of METH, in: Poster presented at: Society of Forensic Toxicologists Annual Meeting, October 2015, Atlanta, GA."},{"key":"10.1016\/j.jmsacl.2025.07.001_b0035","unstructured":"L.E. Wolfe, S.W. Fleming, J.E. Meeker, Evaluation of patients prescribed Adderall for the presence of METH, in: Poster presented at: Society of Forensic Toxicologists Annual Meeting, October 2014, Grand Rapids, MI."},{"key":"10.1016\/j.jmsacl.2025.07.001_b0040","doi-asserted-by":"crossref","first-page":"170","DOI":"10.1093\/jat\/33.3.170","article-title":"Low concentrations of METH detectable in urine in the presence of high concentrations of METH","volume":"33","author":"Jemionek","year":"2009","journal-title":"J. Anal. Toxicol."},{"key":"10.1016\/j.jmsacl.2025.07.001_b0045","first-page":"583","article-title":"Clinical benefits of direct-to-definitive testing for monitoring compliance in pain management","volume":"21","author":"Gencheva","year":"2018","journal-title":"Pain Phys."},{"key":"10.1016\/j.jmsacl.2025.07.001_b0050","doi-asserted-by":"crossref","first-page":"489","DOI":"10.1373\/jalm.2017.023341","article-title":"Executive summary AACC LMPG: using clinical laboratory tests to monitor drug therapy in pain management patients","volume":"2","author":"Jannetto","year":"2018","journal-title":"J. Appl. Lab. Med."},{"key":"10.1016\/j.jmsacl.2025.07.001_b0055","first-page":"SE1","article-title":"Immunoassay-based drug tests are inadequately sensitive for medication compliance monitoring in patients treated for chronic pain","volume":"20","author":"Snyder","year":"2017","journal-title":"Pain Phys."},{"key":"10.1016\/j.jmsacl.2025.07.001_b0060","doi-asserted-by":"crossref","first-page":"83","DOI":"10.1093\/jat\/bks096","article-title":"Differentiating medicinal from illicit use in positive METH results in a pain population","volume":"37","author":"West","year":"2013","journal-title":"J. Anal. Toxicol."},{"key":"10.1016\/j.jmsacl.2025.07.001_b0065","unstructured":"Aegis Sciences Corporation. METH interpretation and D\/L isomer testing. PM155-Clinical-Reference-Guide-N.pdf. Accessed February 9, 2025."}],"container-title":["Journal of Mass Spectrometry and Advances in the Clinical Lab"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2667145X25000203?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2667145X25000203?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,1,7]],"date-time":"2026-01-07T07:22:51Z","timestamp":1767770571000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2667145X25000203"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,8]]},"references-count":13,"alternative-id":["S2667145X25000203"],"URL":"https:\/\/doi.org\/10.1016\/j.jmsacl.2025.07.001","relation":{},"ISSN":["2667-145X"],"issn-type":[{"value":"2667-145X","type":"print"}],"subject":[],"published":{"date-parts":[[2025,8]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Urine methamphetamine-to-amphetamine ratio by LC-MS\/MS to differentiate methamphetamine use from pharmaceutical impurity in patients prescribed amphetamine","name":"articletitle","label":"Article Title"},{"value":"Journal of Mass Spectrometry and Advances in the Clinical Lab","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jmsacl.2025.07.001","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2025 THE AUTHORS. Publishing services by ELSEVIER B.V. on behalf of MSACL.","name":"copyright","label":"Copyright"}]}}