{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,30]],"date-time":"2025-10-30T11:14:46Z","timestamp":1761822886415,"version":"3.44.0"},"reference-count":19,"publisher":"Elsevier BV","issue":"1-2","license":[{"start":{"date-parts":[[2006,6,1]],"date-time":"2006-06-01T00:00:00Z","timestamp":1149120000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2006,6,1]],"date-time":"2006-06-01T00:00:00Z","timestamp":1149120000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Neuroscience Methods"],"published-print":{"date-parts":[[2006,6]]},"DOI":"10.1016\/j.jneumeth.2005.12.008","type":"journal-article","created":{"date-parts":[[2006,2,10]],"date-time":"2006-02-10T07:29:52Z","timestamp":1139556592000},"page":"96-101","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":51,"title":["A feasibility study of optical coherence tomography for guiding deep brain probes"],"prefix":"10.1016","volume":"154","author":[{"given":"Sung W.","family":"Jeon","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mark A.","family":"Shure","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ken B.","family":"Baker","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"David","family":"Huang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Andrew M.","family":"Rollins","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ali","family":"Chahlavi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ali R.","family":"Rezai","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.jneumeth.2005.12.008_bib1","doi-asserted-by":"crossref","first-page":"403","DOI":"10.1016\/0140-6736(91)91175-T","article-title":"Long-term suppression of tremor by chronic stimulation of the ventral intermediate thalamic nucleus","volume":"337","author":"Benabid","year":"1991","journal-title":"Lancet"},{"key":"10.1016\/j.jneumeth.2005.12.008_bib2","doi-asserted-by":"crossref","first-page":"65","DOI":"10.1016\/S0165-0270(96)00104-5","article-title":"Imaging developing neural morphology using optical coherence tomography","volume":"70","author":"Boppart","year":"1996","journal-title":"J Neurosci Methods"},{"key":"10.1016\/j.jneumeth.2005.12.008_bib3","doi-asserted-by":"crossref","first-page":"834","DOI":"10.1097\/00006123-199810000-00068","article-title":"Optical coherence tomography for neurosurgical imaging of human intracortical melanoma","volume":"43","author":"Boppart","year":"1998","journal-title":"Neurosurgery"},{"key":"10.1016\/j.jneumeth.2005.12.008_bib4","doi-asserted-by":"crossref","first-page":"275","DOI":"10.1006\/jsre.1998.5555","article-title":"High-resolution optical coherence tomography-guided laser ablation of surgical tissue","volume":"82","author":"Boppart","year":"1999","journal-title":"J Surg Res"},{"key":"10.1016\/j.jneumeth.2005.12.008_bib5","doi-asserted-by":"crossref","first-page":"56","DOI":"10.1111\/j.1751-1097.1998.tb05165.x","article-title":"Optical doppler tomography: imaging in vivo blood flow dynamics following pharmacological intervention and photodynamic therapy","volume":"67","author":"Chen","year":"1998","journal-title":"Photochem Photobiol"},{"key":"10.1016\/j.jneumeth.2005.12.008_bib6","doi-asserted-by":"crossref","first-page":"2945","DOI":"10.1364\/JOSAA.18.002945","article-title":"Primate retina imaging with polarization-sensitive optical coherence tomography","volume":"18","author":"Ducros","year":"2001","journal-title":"J Opt Soc Am A Opt Image Sci Vis"},{"key":"10.1016\/j.jneumeth.2005.12.008_bib7","doi-asserted-by":"crossref","first-page":"239","DOI":"10.1088\/0034-4885\/66\/2\/204","article-title":"Optical coherence tomography-principles and applications","volume":"66","author":"Fercher","year":"2003","journal-title":"Rep Prog Phys"},{"key":"10.1016\/j.jneumeth.2005.12.008_bib8","doi-asserted-by":"crossref","first-page":"498","DOI":"10.3171\/jns.2000.93.3.0498","article-title":"Use of an intracranial near-infrared probe for localization during stereotatic surgery for movement disorders","volume":"93","author":"Giller","year":"2000","journal-title":"J Neurosurg"},{"key":"10.1016\/j.jneumeth.2005.12.008_bib9","doi-asserted-by":"crossref","first-page":"287","DOI":"10.1016\/S0165-3806(98)00063-7","article-title":"A quantitative study of the progress of myelination in the rat central nervous system, using immunohistochemical method for proteolipid protein","volume":"108","author":"Hamano","year":"1998","journal-title":"Brain Res Dev Brain Res"},{"key":"10.1016\/j.jneumeth.2005.12.008_bib10","doi-asserted-by":"crossref","first-page":"1178","DOI":"10.1126\/science.1957169","article-title":"Optical coherence tomography","volume":"254","author":"Huang","year":"1991","journal-title":"Science"},{"key":"10.1016\/j.jneumeth.2005.12.008_bib11","doi-asserted-by":"crossref","first-page":"437","DOI":"10.1117\/1.429894","article-title":"Computational and in vivo investigation of optical reflectance from human brain to assist neurosurgery","volume":"3","author":"Johns","year":"1998","journal-title":"J Biomed Opt"},{"key":"10.1016\/j.jneumeth.2005.12.008_bib12","doi-asserted-by":"crossref","first-page":"1105","DOI":"10.1056\/NEJM199810153391603","article-title":"Electrical stimulation of the subthalamic nucleus in advanced Parkinson's disease","volume":"339","author":"Limousin","year":"1998","journal-title":"N Engl J Med"},{"year":"1998","series-title":"The rat brain in stereotaxic coordinates","author":"Paxinos","key":"10.1016\/j.jneumeth.2005.12.008_bib13"},{"key":"10.1016\/j.jneumeth.2005.12.008_bib14","doi-asserted-by":"crossref","first-page":"1844","DOI":"10.1364\/OE.11.001844","article-title":"Look-ahead distance of a fiber probe used to assist neurosurgery: Phantom and Monte Carlo study","volume":"11","author":"Qian","year":"2003","journal-title":"Opt Expr"},{"key":"10.1016\/j.jneumeth.2005.12.008_bib15","doi-asserted-by":"crossref","first-page":"219","DOI":"10.1364\/OE.3.000219","article-title":"In vivo video rate optical coherence tomography","volume":"3","author":"Rollins","year":"1998","journal-title":"Opt Expr"},{"key":"10.1016\/j.jneumeth.2005.12.008_bib16","doi-asserted-by":"crossref","first-page":"123","DOI":"10.1117\/1.1428291","article-title":"Real-time in vivo color Doppler optical coherence tomography","volume":"7","author":"Rollins","year":"2002","journal-title":"J Biomed Opt"},{"key":"10.1016\/j.jneumeth.2005.12.008_bib17","doi-asserted-by":"crossref","first-page":"1705","DOI":"10.1088\/0031-9155\/39\/10\/013","article-title":"Optical-coherence tomography of a dense tissue: statistics of attenuation and backscattering","volume":"39","author":"Schmitt","year":"1994","journal-title":"Phys Med Biol"},{"key":"10.1016\/j.jneumeth.2005.12.008_bib18","unstructured":"Sorin WV, Heffner BL. Polarization independent optical coherence domain reflectometry. US Patent 5202745, Hewlett-Packard Company, 1993."},{"key":"10.1016\/j.jneumeth.2005.12.008_bib19","doi-asserted-by":"crossref","first-page":"2258","DOI":"10.1364\/OL.20.002258","article-title":"Determination of the refractive index of highly scattering human tissue by optical coherence tomography","volume":"20","author":"Tearney","year":"1995","journal-title":"Opt Lett"}],"container-title":["Journal of Neuroscience Methods"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0165027005004528?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0165027005004528?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,9,28]],"date-time":"2025-09-28T00:09:19Z","timestamp":1759018159000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0165027005004528"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2006,6]]},"references-count":19,"journal-issue":{"issue":"1-2","published-print":{"date-parts":[[2006,6]]}},"alternative-id":["S0165027005004528"],"URL":"https:\/\/doi.org\/10.1016\/j.jneumeth.2005.12.008","relation":{},"ISSN":["0165-0270"],"issn-type":[{"type":"print","value":"0165-0270"}],"subject":[],"published":{"date-parts":[[2006,6]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"A feasibility study of optical coherence tomography for guiding deep brain probes","name":"articletitle","label":"Article Title"},{"value":"Journal of Neuroscience Methods","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jneumeth.2005.12.008","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2005 Elsevier B.V. All rights reserved.","name":"copyright","label":"Copyright"}]}}