{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T16:00:24Z","timestamp":1740153624046,"version":"3.37.3"},"reference-count":7,"publisher":"Wiley","issue":"4","license":[{"start":{"date-parts":[[2015,1,13]],"date-time":"2015-01-13T00:00:00Z","timestamp":1421107200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"},{"start":{"date-parts":[[2015,1,13]],"date-time":"2015-01-13T00:00:00Z","timestamp":1421107200000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2015,11,3]],"date-time":"2015-11-03T00:00:00Z","timestamp":1446508800000},"content-version":"vor","delay-in-days":294,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"funder":[{"name":"Boryung Soo & Soo Ltd., Seoul, Korea"}],"content-domain":{"domain":["clinicalkey.jp","clinicalkey.com","journalofarrhythmia.com","clinicalkey.es","clinicalkey.com.au","clinicalkey.fr","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Arrhythmia"],"published-print":{"date-parts":[[2015,8]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec><jats:title>Background<\/jats:title><jats:p>We performed this study to evaluate the feasibility and accuracy of a new mobile electrocardiography (ECG) device, ER\u20102000<jats:sup>\u00ae<\/jats:sup>, in detecting cardiac arrhythmia, by comparing it to a 12\u2010lead ECG used as the gold standard.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>Mode 1 of ER\u20102000<jats:sup>\u00ae<\/jats:sup> was recorded using three electrodes with cables attached to the anterior chest wall, and mode 2 was recorded using the side chest channel and finger channel. Standard 12\u2010lead ECG was used to record with a speed of 25 mm\/s, simultaneously.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>Seventeen patients with complaints of palpitation were enrolled. Twelve\u2010lead ECG revealed normal sinus rhythm in three patients, sinus tachycardia in one, atrial fibrillation (AF) in two, atrial tachycardia (AT) in one, first degree atrioventricular block in one, pacing rhythm in two patients who underwent permanent pacemaker implantation, AF with intermittent ventricular pacing in one, complete right bundle branch block in one, J\u2010wave elevation in one, narrow QRS tachycardia in one, atrial premature beat (APB) in one, ventricular premature beat (VPB) in one, and narrow QRS tachycardia with intermittent aberrant conduction in one. Rhythm diagnosis obtained by the two different modes of ER\u20102000<jats:sup>\u00ae<\/jats:sup> was correlated with that obtained by the 12\u2010lead ECG in all patients except in one in whom ER\u20102000<jats:sup>\u00ae<\/jats:sup> showed one APB while 12\u2010lead ECG showed sinus rhythm. R\u2010R interval was accurately recorded despite the detailed morphology of QRS, and T\u2010wave was somewhat modified with the use of ER\u20102000<jats:sup>\u00ae<\/jats:sup>. A pacing blip detected by 12\u2010lead ECG was not detected by ER\u20102000<jats:sup>\u00ae<\/jats:sup> despite a similar wide QRS duration in the paced QRS.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusions<\/jats:title><jats:p>A rhythm strip obtained using ER\u20102000<jats:sup>\u00ae<\/jats:sup> is accurate in diagnosing arrhythmia, despite some differences in the detailed morphology of the QRS and T\u2010wave, and the pacing spike compared to those obtained by the 12\u2010lead ECG.<\/jats:p><\/jats:sec>","DOI":"10.1016\/j.joa.2014.12.003","type":"journal-article","created":{"date-parts":[[2015,1,14]],"date-time":"2015-01-14T08:20:18Z","timestamp":1421223618000},"page":"201-209","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":2,"title":["Feasibility and accuracy of a new mobile electrocardiography device, ER\u20102000<sup>\u00ae<\/sup>, in the diagnosis of arrhythmia"],"prefix":"10.1002","volume":"31","author":[{"given":"Yae Min","family":"Park","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dae In","family":"Lee","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hwan Cheol","family":"Park","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jaemin","family":"Shim","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jong\u2010Il","family":"Choi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hong Euy","family":"Lim","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sang Weon","family":"Park","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Young\u2010Hoon","family":"Kim","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2015,1,13]]},"reference":[{"key":"e_1_2_8_2_2","doi-asserted-by":"publisher","DOI":"10.1161\/STROKEAHA.109.570382"},{"key":"e_1_2_8_3_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.2009.02407.x"},{"key":"e_1_2_8_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9149(96)00766-7"},{"key":"e_1_2_8_5_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.STR.17.2.192"},{"key":"e_1_2_8_6_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.STR.16.6.950"},{"key":"e_1_2_8_7_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jns.2012.10.001"},{"key":"e_1_2_8_8_2","first-page":"1113","article-title":"Wireless remote monitoring of atrial fibrillation using reconstructed 12\u2010lead ECGs","volume":"2010","author":"Vukajlovic D.","year":"2010","journal-title":"Conf Proc IEEE Eng Med Biol Soc"}],"container-title":["Journal of Arrhythmia"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/api.elsevier.com\/content\/article\/PII:S1880427614001896?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/api.elsevier.com\/content\/article\/PII:S1880427614001896?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1016\/j.joa.2014.12.003","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,29]],"date-time":"2023-09-29T04:52:00Z","timestamp":1695963120000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1016\/j.joa.2014.12.003"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,1,13]]},"references-count":7,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2015,8]]}},"alternative-id":["10.1016\/j.joa.2014.12.003"],"URL":"https:\/\/doi.org\/10.1016\/j.joa.2014.12.003","archive":["Portico"],"relation":{},"ISSN":["1880-4276","1883-2148"],"issn-type":[{"type":"print","value":"1880-4276"},{"type":"electronic","value":"1883-2148"}],"subject":[],"published":{"date-parts":[[2015,1,13]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Feasibility and accuracy of a new mobile electrocardiography device, ER-2000\u00ae, in the diagnosis of arrhythmia","name":"articletitle","label":"Article Title"},{"value":"Journal of Arrhythmia","name":"journaltitle","label":"Journal Title"},{"value":"http:\/\/dx.doi.org\/10.1016\/j.joa.2014.12.003","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2015 Japanese Heart Rhythm Society. Published by Elsevier B.V.","name":"copyright","label":"Copyright"}]}}