{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,17]],"date-time":"2026-06-17T12:51:49Z","timestamp":1781700709600,"version":"3.54.5"},"reference-count":51,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2020,3,1]],"date-time":"2020-03-01T00:00:00Z","timestamp":1583020800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2020,3,1]],"date-time":"2020-03-01T00:00:00Z","timestamp":1583020800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"funder":[{"DOI":"10.13039\/501100000923","name":"Australian Research Council","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100000923","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Building Engineering"],"published-print":{"date-parts":[[2020,3]]},"DOI":"10.1016\/j.jobe.2019.100999","type":"journal-article","created":{"date-parts":[[2019,10,17]],"date-time":"2019-10-17T11:49:28Z","timestamp":1571312968000},"page":"100999","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":40,"special_numbering":"C","title":["Critical assessment on operating water droplet sizes for fire sprinkler and water mist systems"],"prefix":"10.1016","volume":"28","author":[{"given":"Hengrui","family":"Liu","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cheng","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ivan Miguel","family":"De Cachinho Cordeiro","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anthony Chun Yin","family":"Yuen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Qian","family":"Chen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Qing Nian","family":"Chan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sanghoon","family":"Kook","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Guan Heng","family":"Yeoh","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.jobe.2019.100999_bib1","doi-asserted-by":"crossref","first-page":"682","DOI":"10.1016\/j.jclepro.2018.02.046","article-title":"Assessment of a clean and efficient fire-extinguishing technique: continuous and cycling discharge water mist system","volume":"182","author":"Zhou","year":"2018","journal-title":"J. Clean. Prod."},{"key":"10.1016\/j.jobe.2019.100999_bib2","doi-asserted-by":"crossref","first-page":"706","DOI":"10.1016\/j.applthermaleng.2015.10.110","article-title":"Experimental study on the interaction between fire and water mist in long and narrow spaces","volume":"94","author":"Zhang","year":"2016","journal-title":"Appl. Therm. Eng."},{"key":"10.1016\/j.jobe.2019.100999_bib3","series-title":"The Role of Fire Dynamics in Design of Water Mist Fire Suppression Systems","author":"Mawhinney","year":"1996"},{"issue":"2","key":"10.1016\/j.jobe.2019.100999_bib4","doi-asserted-by":"crossref","first-page":"327","DOI":"10.1007\/s40430-015-0307-7","article-title":"CFD analysis of smoke transport inside an aircraft cargo compartment","volume":"38","author":"Papa","year":"2015","journal-title":"J. Braz. Soc. Mech. Sci. Eng."},{"issue":"3","key":"10.1016\/j.jobe.2019.100999_bib5","doi-asserted-by":"crossref","first-page":"163","DOI":"10.1002\/prs.680220305","article-title":"Mitigation of backdraft with water mist: a reduced\u2010scale experimental study","volume":"22","author":"Weng","year":"2003","journal-title":"Process Saf. Prog."},{"key":"10.1016\/j.jobe.2019.100999_bib6","doi-asserted-by":"crossref","first-page":"1181","DOI":"10.3801\/IAFSS.FSS.8-1181","article-title":"Experimental study of backdraft in a compartment with different opening geometries and its mitigation with water mist","volume":"8","author":"Weng","year":"2005","journal-title":"Fire Saf. Sci."},{"key":"10.1016\/j.jobe.2019.100999_bib7","doi-asserted-by":"crossref","first-page":"98","DOI":"10.1016\/j.firesaf.2014.08.012","article-title":"Suppression effectiveness of water-mist sprays on accelerated wood-crib fires","volume":"70","author":"Santangelo","year":"2014","journal-title":"Fire Saf. J."},{"issue":"2","key":"10.1016\/j.jobe.2019.100999_bib8","doi-asserted-by":"crossref","first-page":"79","DOI":"10.1016\/S0360-1285(99)00012-X","article-title":"Fire suppression by water sprays","volume":"26","author":"Grant","year":"2000","journal-title":"Prog. Energy Combust. Sci."},{"issue":"6","key":"10.1016\/j.jobe.2019.100999_bib9","doi-asserted-by":"crossref","first-page":"563","DOI":"10.1007\/s11630-011-0511-4","article-title":"Fire extinct experiments with water mist by adding additives","volume":"20","author":"Yang","year":"2011","journal-title":"J. Therm. Sci."},{"issue":"5","key":"10.1016\/j.jobe.2019.100999_bib10","doi-asserted-by":"crossref","first-page":"1369","DOI":"10.1007\/s10694-016-0569-3","article-title":"Full-scale experiments of fire control and suppression in enclosed car parks: a comparison between sprinkler and water-mist systems","volume":"52","author":"Santangelo","year":"2016","journal-title":"Fire Technol."},{"issue":"2\u20133","key":"10.1016\/j.jobe.2019.100999_bib11","doi-asserted-by":"crossref","first-page":"99","DOI":"10.1016\/0379-7112(88)90006-9","article-title":"Thermal response of sprinklers part II. Characteristics and test methods","volume":"13","author":"Theobald","year":"1988","journal-title":"Fire Saf. J."},{"issue":"2\u20133","key":"10.1016\/j.jobe.2019.100999_bib12","doi-asserted-by":"crossref","first-page":"169","DOI":"10.1016\/0379-7112(88)90012-4","article-title":"Thermal response of sprinklers\u2014a theoretical approach","volume":"13","author":"Melinek","year":"1988","journal-title":"Fire Saf. J."},{"issue":"1\u20132","key":"10.1016\/j.jobe.2019.100999_bib13","doi-asserted-by":"crossref","first-page":"89","DOI":"10.1016\/0379-7112(88)90047-1","article-title":"The thermal performance of sprinkler heads","volume":"14","author":"Thorne","year":"1988","journal-title":"Fire Saf. J."},{"key":"10.1016\/j.jobe.2019.100999_bib14","article-title":"Effect of heat collector plate on thermal sensitivity of sprinkler heads in large terminal Halls","volume":"25","author":"Lin","year":"2019","journal-title":"J. Build. Eng.."},{"issue":"6","key":"10.1016\/j.jobe.2019.100999_bib15","doi-asserted-by":"crossref","first-page":"545","DOI":"10.1016\/S0379-7112(01)00009-1","article-title":"Phase Doppler interferometry measurements in water sprays produced by residential fire sprinklers","volume":"36","author":"Widmann","year":"2001","journal-title":"Fire Saf. J."},{"issue":"4","key":"10.1016\/j.jobe.2019.100999_bib16","doi-asserted-by":"crossref","first-page":"297","DOI":"10.1023\/A:1012727614590","article-title":"Non-intrusive measurements in fire sprinkler sprays","volume":"37","author":"Widmann","year":"2001","journal-title":"Fire Technol."},{"issue":"3","key":"10.1016\/j.jobe.2019.100999_bib17","doi-asserted-by":"crossref","first-page":"140","DOI":"10.1016\/j.firesaf.2011.01.003","article-title":"Experimental investigation of spray formation as affected by sprinkler geometry","volume":"46","author":"Zhou","year":"2011","journal-title":"Fire Saf. J."},{"issue":"4","key":"10.1016\/j.jobe.2019.100999_bib18","doi-asserted-by":"crossref","first-page":"295","DOI":"10.1016\/S0379-7112(97)00011-8","article-title":"Extinction limit of a pool fire with a water mist","volume":"28","author":"Kim","year":"1997","journal-title":"Fire Saf. J."},{"key":"10.1016\/j.jobe.2019.100999_bib19","doi-asserted-by":"crossref","first-page":"174","DOI":"10.1016\/j.expthermflusci.2013.09.008","article-title":"Experimental research on the water mist fire suppression performance in an enclosed space by changing the characteristics of nozzles","volume":"52","author":"Yinshui","year":"2014","journal-title":"Exp. Therm. Fluid Sci."},{"issue":"8","key":"10.1016\/j.jobe.2019.100999_bib20","doi-asserted-by":"crossref","first-page":"3142","DOI":"10.1016\/j.nucengdes.2011.06.002","article-title":"Numerically investigating fire suppression mechanisms for the water mist with various droplet sizes through FDS code","volume":"241","author":"Ferng","year":"2011","journal-title":"Nucl. Eng. Des."},{"issue":"3","key":"10.1016\/j.jobe.2019.100999_bib21","doi-asserted-by":"crossref","first-page":"253","DOI":"10.1016\/S0379-7112(98)00007-1","article-title":"On water mist fire suppression mechanisms in a gaseous diffusion flame","volume":"31","author":"Ndubizu","year":"1998","journal-title":"Fire Saf. J."},{"key":"10.1016\/j.jobe.2019.100999_bib22","article-title":"Characterisation of soot particle size distribution through population balance approach and soot diagnostic techniques for a buoyant non-premixed flame","author":"Wang","year":"2019","journal-title":"J. Energy Inst."},{"issue":"1","key":"10.1016\/j.jobe.2019.100999_bib23","doi-asserted-by":"crossref","DOI":"10.3390\/fire2010007","article-title":"Natural ventilated smoke control simulation case study using different settings of smoke vents and curtains in a large atrium","volume":"2","author":"Yuen","year":"2019","journal-title":"Fire"},{"issue":"5","key":"10.1016\/j.jobe.2019.100999_bib24","doi-asserted-by":"crossref","first-page":"477","DOI":"10.1007\/s12273-014-0164-9","article-title":"Fire scene investigation of an arson fire incident using computational fluid dynamics based fire simulation","volume":"7","author":"Yuen","year":"2014","journal-title":"Build. Simul."},{"key":"10.1016\/j.jobe.2019.100999_bib25","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1016\/j.csfs.2014.01.001","article-title":"Fire scene reconstruction of a furnished compartment room in a house fire","volume":"1","author":"Yuen","year":"2014","journal-title":"Case Stud. Fire Saf."},{"issue":"4","key":"10.1016\/j.jobe.2019.100999_bib26","doi-asserted-by":"crossref","first-page":"327","DOI":"10.1016\/S0379-7112(00)00038-2","article-title":"A quasi-steady-state model for predicting fire suppression in spaces protected by water mist systems","volume":"35","author":"Back","year":"2000","journal-title":"Fire Saf. J."},{"issue":"7","key":"10.1016\/j.jobe.2019.100999_bib27","doi-asserted-by":"crossref","first-page":"1486","DOI":"10.3390\/app9071486","article-title":"Computational study of wet steam flow to optimize steam ejector efficiency for potential fire suppression application","volume":"9","author":"Li","year":"2019","journal-title":"Appl. Sci."},{"key":"10.1016\/j.jobe.2019.100999_bib28","doi-asserted-by":"crossref","first-page":"586","DOI":"10.1016\/j.firesaf.2017.03.040","article-title":"Influence of the particle injection rate, droplet size distribution and volume flux angular distribution on the results and computational time of water spray CFD simulations","volume":"91","author":"Beji","year":"2017","journal-title":"Fire Saf. J."},{"issue":"4","key":"10.1016\/j.jobe.2019.100999_bib29","doi-asserted-by":"crossref","first-page":"307","DOI":"10.1016\/S0379-7112(99)00004-1","article-title":"Numerical simulation of the penetration capability of sprinkler sprays","volume":"32","author":"Nam","year":"1999","journal-title":"Fire Saf. J."},{"issue":"2","key":"10.1016\/j.jobe.2019.100999_bib30","doi-asserted-by":"crossref","first-page":"3287","DOI":"10.1016\/j.proci.2016.06.058","article-title":"Large eddy simulation of suppression of turbulent line fires by base-injected water mist","volume":"36","author":"Vilfayeau","year":"2017","journal-title":"Proc. Combust. Inst."},{"issue":"6\u20138","key":"10.1016\/j.jobe.2019.100999_bib31","doi-asserted-by":"crossref","first-page":"324","DOI":"10.1080\/10618562.2017.1357809","article-title":"On the influences of key modelling constants of large eddy simulations for large-scale compartment fires predictions","volume":"31","author":"Yuen","year":"2017","journal-title":"Int. J. Comput. Fluid Dyn."},{"key":"10.1016\/j.jobe.2019.100999_bib32","doi-asserted-by":"crossref","first-page":"8","DOI":"10.1016\/j.jocs.2017.10.022","article-title":"Numerical study of fire spread using the level-set method with large eddy simulation incorporating detailed chemical kinetics gas-phase combustion model","volume":"24","author":"Chen","year":"2018","journal-title":"J. Comput. Sci."},{"key":"10.1016\/j.jobe.2019.100999_bib33","doi-asserted-by":"crossref","first-page":"310","DOI":"10.1016\/j.ijheatmasstransfer.2018.04.093","article-title":"Predicting the fire spread rate of a sloped pine needle board utilizing pyrolysis modelling with detailed gas-phase combustion","volume":"125","author":"Chen","year":"2018","journal-title":"Int. J. Heat Mass Transf."},{"issue":"6","key":"10.1016\/j.jobe.2019.100999_bib34","doi-asserted-by":"crossref","first-page":"459","DOI":"10.1615\/ComputThermalScien.2013005954","article-title":"Numerical simulation of an enclosure fire in a large test Hall","volume":"5","author":"Yuen","year":"2013","journal-title":"Comput. Therm. Sci."},{"issue":"6","key":"10.1016\/j.jobe.2019.100999_bib35","doi-asserted-by":"crossref","first-page":"494","DOI":"10.1177\/0734904118800907","article-title":"Establishing pyrolysis kinetics for the modelling of the flammability and burning characteristics of solid combustible materials","volume":"36","author":"Yuen","year":"2018","journal-title":"J. Fire Sci."},{"issue":"3","key":"10.1016\/j.jobe.2019.100999_bib36","doi-asserted-by":"crossref","first-page":"483","DOI":"10.1007\/s10694-013-0335-8","article-title":"Modeling and simulation of high pressure water mist systems","volume":"50","author":"Sikanen","year":"2013","journal-title":"Fire Technol."},{"issue":"5","key":"10.1016\/j.jobe.2019.100999_bib37","first-page":"389","article-title":"Can we predict fire extinction by water mist with FDS?","volume":"14","author":"Jenft","year":"2013","journal-title":"Mec. Ind."},{"key":"10.1016\/j.jobe.2019.100999_bib38","doi-asserted-by":"crossref","first-page":"305","DOI":"10.1016\/j.jobe.2016.05.002","article-title":"Numerical investigation on window ejected facade flames","volume":"8","author":"Duny","year":"2016","journal-title":"J. Build. Eng."},{"key":"10.1016\/j.jobe.2019.100999_bib39","unstructured":"McGrattan, K., et al., Fire Dynamics Simulator Technical Reference Guide Volume 1: Mathematical Model."},{"key":"10.1016\/j.jobe.2019.100999_bib40","doi-asserted-by":"crossref","first-page":"205","DOI":"10.1016\/j.energy.2014.10.004","article-title":"Numerical study of primary steam superheating effects on steam ejector flow and its pumping performance","volume":"78","author":"Wang","year":"2014","journal-title":"Energy"},{"key":"10.1016\/j.jobe.2019.100999_bib41","series-title":"Encyclopedia of Fluid Mechanics Vol 3: Gas-liquid Flows","author":"Cheremisinoff","year":"1986"},{"key":"10.1016\/j.jobe.2019.100999_bib42","doi-asserted-by":"crossref","first-page":"901","DOI":"10.3801\/IAFSS.FSS.4-901","article-title":"Suppression of rack-storage fires by water","volume":"4","author":"Yu","year":"1994","journal-title":"Fire Saf. Sci."},{"key":"10.1016\/j.jobe.2019.100999_bib43","article-title":"Reduced-scale experiments to characterize the suppression of rack-storage commodity fires","volume":"6439","author":"Hamins","year":"1999","journal-title":"NIST Tech. Rep. NISTIR"},{"issue":"11","key":"10.1016\/j.jobe.2019.100999_bib44","doi-asserted-by":"crossref","first-page":"1309","DOI":"10.1016\/S0360-1323(03)00134-3","article-title":"An experimental and numerical study on fire suppression using a water mist in an enclosure","volume":"38","author":"Kim","year":"2003","journal-title":"Build. Environ."},{"issue":"4","key":"10.1016\/j.jobe.2019.100999_bib45","doi-asserted-by":"crossref","first-page":"377","DOI":"10.1007\/s11630-001-0047-0","article-title":"Experimental study on the interaction of fine water spray with liquid pool fires","volume":"10","author":"Liao","year":"2001","journal-title":"J. Therm. Sci."},{"issue":"3","key":"10.1016\/j.jobe.2019.100999_bib46","doi-asserted-by":"crossref","first-page":"2723","DOI":"10.1016\/j.proci.2014.05.078","article-title":"Characterization of interactions between hot air plumes and water sprays for sprinkler protection","volume":"35","author":"Zhou","year":"2015","journal-title":"Proc. Combust. Inst."},{"issue":"3","key":"10.1016\/j.jobe.2019.100999_bib47","doi-asserted-by":"crossref","first-page":"32","DOI":"10.1177\/104239159901000303","article-title":"A review of water mist fire suppression systems\u2014 fundamental studies","volume":"10","author":"Liu","year":"1999","journal-title":"J. Fire Prot. Eng."},{"key":"10.1016\/j.jobe.2019.100999_bib48","series-title":"NFPA 750 Standard for Water Mist Fire Suppression Systems","author":"Association","year":"2000"},{"key":"10.1016\/j.jobe.2019.100999_bib49","doi-asserted-by":"crossref","first-page":"626","DOI":"10.1016\/j.jlp.2016.04.010","article-title":"Optimization of water mist droplet size by using CFD modeling for fire suppressions","volume":"44","author":"Wang","year":"2016","journal-title":"J. Loss Prev. Process. Ind."},{"issue":"10","key":"10.1016\/j.jobe.2019.100999_bib50","doi-asserted-by":"crossref","first-page":"2309","DOI":"10.1016\/j.buildenv.2010.04.017","article-title":"Experimental and numerical study on water mist suppression system on room fire","volume":"45","author":"Yang","year":"2010","journal-title":"Build. Environ."},{"key":"10.1016\/j.jobe.2019.100999_bib51","doi-asserted-by":"crossref","first-page":"441","DOI":"10.1016\/j.expthermflusci.2018.01.015","article-title":"Characterization of a simplex water mist nozzle and its performance in extinguishing liquid pool fire","volume":"93","author":"Shrigondekar","year":"2018","journal-title":"Exp. Therm. Fluid Sci."}],"container-title":["Journal of Building Engineering"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2352710219314081?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2352710219314081?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,11,7]],"date-time":"2025-11-07T02:36:40Z","timestamp":1762483000000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2352710219314081"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,3]]},"references-count":51,"alternative-id":["S2352710219314081"],"URL":"https:\/\/doi.org\/10.1016\/j.jobe.2019.100999","relation":{},"ISSN":["2352-7102"],"issn-type":[{"value":"2352-7102","type":"print"}],"subject":[],"published":{"date-parts":[[2020,3]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Critical assessment on operating water droplet sizes for fire sprinkler and water mist systems","name":"articletitle","label":"Article Title"},{"value":"Journal of Building Engineering","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jobe.2019.100999","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2019 Published by Elsevier Ltd.","name":"copyright","label":"Copyright"}],"article-number":"100999"}}