{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,27]],"date-time":"2026-05-27T16:13:04Z","timestamp":1779898384025,"version":"3.53.1"},"reference-count":76,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2022,5,1]],"date-time":"2022-05-01T00:00:00Z","timestamp":1651363200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2022,5,1]],"date-time":"2022-05-01T00:00:00Z","timestamp":1651363200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2022,5,1]],"date-time":"2022-05-01T00:00:00Z","timestamp":1651363200000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-017"},{"start":{"date-parts":[[2022,5,1]],"date-time":"2022-05-01T00:00:00Z","timestamp":1651363200000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-037"},{"start":{"date-parts":[[2022,5,1]],"date-time":"2022-05-01T00:00:00Z","timestamp":1651363200000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-012"},{"start":{"date-parts":[[2022,5,1]],"date-time":"2022-05-01T00:00:00Z","timestamp":1651363200000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-029"},{"start":{"date-parts":[[2022,5,1]],"date-time":"2022-05-01T00:00:00Z","timestamp":1651363200000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-004"}],"funder":[{"DOI":"10.13039\/501100019211","name":"Institute of Engineering Research, Seoul National University","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100019211","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100003725","name":"National Research Foundation of Korea","doi-asserted-by":"publisher","award":["2021R1A5A1032433"],"award-info":[{"award-number":["2021R1A5A1032433"]}],"id":[{"id":"10.13039\/501100003725","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Building Engineering"],"published-print":{"date-parts":[[2022,5]]},"DOI":"10.1016\/j.jobe.2022.103993","type":"journal-article","created":{"date-parts":[[2022,1,10]],"date-time":"2022-01-10T08:26:19Z","timestamp":1641803179000},"page":"103993","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":50,"special_numbering":"C","title":["Retrofitting of unreinforced masonry structures and considerations for heritage-sensitive constructions"],"prefix":"10.1016","volume":"49","author":[{"given":"Fahimeh","family":"Yavartanoo","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thomas H.-K.","family":"Kang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.jobe.2022.103993_bib1","series-title":"Structural In-Plane Behavior of Masonry Walls Externally Retrofitted with Fiber Reinforced Materials","author":"Zamani Ahari","year":"2013"},{"issue":"1","key":"10.1016\/j.jobe.2022.103993_bib2","article-title":"Strengthening\/retrofitting techniques on unreinforced masonry structure\/element subjected to seismic loads: a literature review","volume":"12","author":"Wang","year":"2018","journal-title":"Open Construct. Build Technol. J."},{"key":"10.1016\/j.jobe.2022.103993_bib3","doi-asserted-by":"crossref","first-page":"454","DOI":"10.1016\/j.engfailanal.2019.01.031","article-title":"The retrofitting of historical masonry buildings with insufficient seismic resistance using conventional and non-conventional techniques","volume":"97","author":"Sayin","year":"2019","journal-title":"Eng. Fail. Anal."},{"key":"10.1016\/j.jobe.2022.103993_bib4","doi-asserted-by":"crossref","first-page":"80","DOI":"10.1016\/j.engstruct.2015.09.020","article-title":"Experimental testing and finite element modelling of earth block masonry","volume":"104","author":"Miccoli","year":"2015","journal-title":"Eng. Struct."},{"issue":"2","key":"10.1016\/j.jobe.2022.103993_bib5","doi-asserted-by":"crossref","first-page":"253","DOI":"10.1080\/13632460109350394","article-title":"Out-of-Plane seismic resistance of masonry walls","volume":"5","author":"Felice","year":"2001","journal-title":"J. Earthq. Eng."},{"key":"10.1016\/j.jobe.2022.103993_bib6","doi-asserted-by":"crossref","first-page":"327","DOI":"10.1016\/j.engstruct.2012.02.039","article-title":"A new discrete element model for the evaluation of the seismic behaviour of unreinforced masonry buildings","volume":"40","author":"Cali\u00f2","year":"2012","journal-title":"Eng. Struct."},{"issue":"2","key":"10.1016\/j.jobe.2022.103993_bib7","doi-asserted-by":"crossref","first-page":"179","DOI":"10.1002\/stc.55","article-title":"Seismic evaluation and innovative retrofit of a historical building in Tunisia","volume":"12","author":"El\u2010Borgi","year":"2005","journal-title":"Struct. Control Health Monit.: Off. J. Int. Assoc. Struct. Control Montor. Euro. Assoc. Control Struct."},{"issue":"5","key":"10.1016\/j.jobe.2022.103993_bib8","doi-asserted-by":"crossref","first-page":"1466","DOI":"10.1016\/j.engstruct.2010.01.027","article-title":"Numerical models for the seismic assessment of an old masonry tower","volume":"32","author":"Pe\u00f1a","year":"2010","journal-title":"Eng. Struct."},{"key":"10.1016\/j.jobe.2022.103993_bib9","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1016\/j.ijdrr.2013.12.004","article-title":"A critical review of retrofitting methods for unreinforced masonry structures","volume":"7","author":"Bhattacharya","year":"2014","journal-title":"Int. J. Disaster Risk Reduc."},{"key":"10.1016\/j.jobe.2022.103993_bib10","series-title":"Rehabilitation and Strengthening of Old Masonry Buildings","author":"Meireles","year":"2013"},{"issue":"7","key":"10.1016\/j.jobe.2022.103993_bib11","doi-asserted-by":"crossref","first-page":"1151","DOI":"10.3390\/ma12071151","article-title":"Some of the latest active strengthening techniques for masonry buildings: a critical analysis","volume":"12","author":"Ferretti","year":"2019","journal-title":"Materials"},{"issue":"4","key":"10.1016\/j.jobe.2022.103993_bib12","first-page":"165","article-title":"Strengthening and rehabilitation conventional methods for masonry structures","volume":"57","author":"Plesu","year":"2011","journal-title":"Buletinul Institutului Politehnic din lasi. Sectia Constructii, Arhitectura"},{"issue":"12","key":"10.1016\/j.jobe.2022.103993_bib13","doi-asserted-by":"crossref","first-page":"1971","DOI":"10.1617\/s11527-014-0359-7","article-title":"Current practice and open issues in strengthening historical buildings with composites","volume":"47","author":"Valluzzi","year":"2014","journal-title":"Mater. Struct."},{"key":"10.1016\/j.jobe.2022.103993_bib14","series-title":"Historic Construction and Conservation: Materials, Systems and Damage","author":"Roca","year":"2019"},{"issue":"8","key":"10.1016\/j.jobe.2022.103993_bib15","doi-asserted-by":"crossref","first-page":"2194","DOI":"10.1016\/j.engstruct.2007.07.008","article-title":"Stone masonry in historical buildings-ways to increase their resistance and durability","volume":"30","author":"Juh\u00e1sov\u00e1","year":"2008","journal-title":"Eng. Struct."},{"issue":"6","key":"10.1016\/j.jobe.2022.103993_bib16","doi-asserted-by":"crossref","first-page":"829","DOI":"10.1617\/s11527-011-9801-2","article-title":"Structural behavior of low-and normal-strength interface mortar of masonry","volume":"45","author":"Zimmermann","year":"2012","journal-title":"Mater. Struct."},{"issue":"1","key":"10.1016\/j.jobe.2022.103993_bib17","doi-asserted-by":"crossref","DOI":"10.2174\/1874149501408010288","article-title":"Modeling approaches for masonry structures","volume":"8","author":"Addessi","year":"2014","journal-title":"Open Civ. Eng. J."},{"issue":"3","key":"10.1016\/j.jobe.2022.103993_bib18","doi-asserted-by":"crossref","first-page":"300","DOI":"10.1080\/15583058.2013.780109","article-title":"Mineralogical and mechanical properties of masonry and mortars of the lucknow monuments circa the 18th century","volume":"9","author":"Rai","year":"2015","journal-title":"Int. J. Architect. Herit."},{"issue":"11","key":"10.1016\/j.jobe.2022.103993_bib19","doi-asserted-by":"crossref","first-page":"1665","DOI":"10.1061\/(ASCE)0733-9445(2005)131:11(1665)","article-title":"Dry joint stone masonry walls subjected to in-plane combined loading","volume":"131","author":"Louren\u00e7o","year":"2005","journal-title":"J. Struct. Eng."},{"issue":"4","key":"10.1016\/j.jobe.2022.103993_bib20","doi-asserted-by":"crossref","first-page":"563","DOI":"10.12989\/eas.2016.11.4.563","article-title":"Discrete element modeling of masonry structures: validation and application","volume":"11","author":"Pulatsu","year":"2016","journal-title":"Earthq. Struct."},{"key":"10.1016\/j.jobe.2022.103993_bib21","article-title":"Earthquake-resistance design of masonry buildings","volume":"vol. 1","author":"Toma\u017eevi\u010d","year":"1999"},{"key":"10.1016\/j.jobe.2022.103993_bib22","series-title":"Seismic Vulnerability Assessment of Ancient Buildings","author":"Candeias","year":"2008"},{"issue":"1","key":"10.1016\/j.jobe.2022.103993_bib23","doi-asserted-by":"crossref","first-page":"145","DOI":"10.1193\/1.1585872","article-title":"Testing of masonry structures for seismic assessment","volume":"12","author":"Calvi","year":"1996","journal-title":"Earthq. Spectra"},{"key":"10.1016\/j.jobe.2022.103993_bib24","series-title":"8th US National Conference on Earthquake Engineering, San Francisco, California, USA","article-title":"Confining masonry using pre-cast RC element for enhanced earthquake resistance","author":"Paikara","year":"2006"},{"key":"10.1016\/j.jobe.2022.103993_bib25","series-title":"13th International Brick and Block Masonry Conference, 1-10","article-title":"A review of conventional seismic retrofitting techniques for URM","author":"ElGawady","year":"2004"},{"issue":"10","key":"10.1016\/j.jobe.2022.103993_bib26","doi-asserted-by":"crossref","first-page":"1059","DOI":"10.1002\/(SICI)1096-9845(199710)26:10<1059::AID-EQE694>3.0.CO;2-M","article-title":"Seismic behaviour of confined masonry walls","volume":"26","author":"Toma\u017eevi\u010d","year":"1997","journal-title":"Earthq. Eng. Struct. Dynam."},{"issue":"5","key":"10.1016\/j.jobe.2022.103993_bib27","doi-asserted-by":"crossref","first-page":"1892","DOI":"10.1016\/j.conbuildmat.2008.09.012","article-title":"Retrofitting of masonry building with reinforced masonry ring-beam","volume":"23","author":"Borri","year":"2009","journal-title":"Construct. Build. Mater."},{"key":"10.1016\/j.jobe.2022.103993_bib28","doi-asserted-by":"crossref","first-page":"122","DOI":"10.1016\/j.conbuildmat.2013.11.020","article-title":"Investigation of in-plane seismic retrofit of unreinforced masonry walls by means of vertical steel ties","volume":"52","author":"Darbhanzi","year":"2014","journal-title":"Construct. Build. Mater."},{"issue":"4","key":"10.1016\/j.jobe.2022.103993_bib29","doi-asserted-by":"crossref","first-page":"281","DOI":"10.1061\/(ASCE)NH.1527-6996.0000096","article-title":"Augmenting strength of collapsed unreinforced masonry junctions: principal damage feature of walls damaged by moderate Indian earthquakes","volume":"14","author":"Dutta","year":"2013","journal-title":"Nat. Hazards Rev."},{"key":"10.1016\/j.jobe.2022.103993_bib30","series-title":"12th Canadian Masonry Symposium, 2-5","article-title":"Combined in-Plane\/Out-of-Plane experimental behaviour of reinforced and strengthened infill masonry walls","author":"Da Porto","year":"2013"},{"key":"10.1016\/j.jobe.2022.103993_bib31","doi-asserted-by":"crossref","first-page":"328","DOI":"10.1016\/j.compositesb.2015.06.012","article-title":"Experimental assessment of an innovative strengthening material for brick masonry infills","volume":"80","author":"Martins","year":"2015","journal-title":"Compos. B Eng."},{"key":"10.1016\/j.jobe.2022.103993_bib32","series-title":"10th International Brick and Block Masonry Conference","article-title":"Injection grouting for repair and retrofit of unreinforced masonry","author":"Schuller","year":"1994"},{"key":"10.1016\/j.jobe.2022.103993_bib33","first-page":"585","article-title":"FRP-structural repointing of masonry assemblages","volume":"vol. 3","author":"Tinazzi","year":"2000"},{"issue":"5","key":"10.1016\/j.jobe.2022.103993_bib34","doi-asserted-by":"crossref","first-page":"1626","DOI":"10.1016\/j.engstruct.2011.01.033","article-title":"Seismic rehabilitation of historical masonry buildings","volume":"33","author":"Branco","year":"2011","journal-title":"Eng. Struct."},{"issue":"7","key":"10.1016\/j.jobe.2022.103993_bib35","doi-asserted-by":"crossref","first-page":"1884","DOI":"10.1061\/(ASCE)0733-9445(1992)118:7(1884)","article-title":"Effectiveness of seismic strengthening techniques for masonry buildings","volume":"118","author":"Karantoni","year":"1992","journal-title":"J. Struct. Eng."},{"key":"10.1016\/j.jobe.2022.103993_bib36","series-title":"2006 NZSEE Conference, 45,10-12, Napier, New Zealand, March","article-title":"Retrofitting of masonry walls using shotcrete","author":"ElGawady","year":"2006"},{"key":"10.1016\/j.jobe.2022.103993_bib37","series-title":"KEERC-MAE Joint Seminar on Risk Mitigation for Regions of Moderate Seismicity","first-page":"234","article-title":"Flexural behavior of retrofitted masonry piers","author":"Abrams","year":"2001"},{"issue":"10","key":"10.1016\/j.jobe.2022.103993_bib38","doi-asserted-by":"crossref","first-page":"3187","DOI":"10.1617\/s11527-014-0390-8","article-title":"Out-of-Plane behaviour of unreinforced masonry strengthened using ferrocement overlay","volume":"48","author":"Kadam","year":"2015","journal-title":"Mater. Struct."},{"key":"10.1016\/j.jobe.2022.103993_bib39","first-page":"485","article-title":"Strengthening and repair of unreinforced masonry structures: state-of-the-art","volume":"vol. 2","author":"Hamid","year":"1994"},{"issue":"9","key":"10.1016\/j.jobe.2022.103993_bib40","doi-asserted-by":"crossref","first-page":"1017","DOI":"10.1061\/(ASCE)0733-9445(2000)126:9(1017)","article-title":"Seismic retrofitting of low-rise masonry and concrete walls using steel strips","volume":"126","author":"Taghdi","year":"2000","journal-title":"J. Struct. Eng."},{"key":"10.1016\/j.jobe.2022.103993_bib41","series-title":"An Improved Means of Reinforcing Adobe Walls-External Vertical Reinforcement","author":"Dowling","year":"2005"},{"key":"10.1016\/j.jobe.2022.103993_bib42","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1007\/s40069-012-0004-1","article-title":"Shear-strengthening of reinforced & prestressed concrete beams using FRP: Part I \u2013 review of previous research","volume":"6","author":"Ibrahim Ary","year":"2012","journal-title":"Int. J. Concrete Struct. Mater."},{"key":"10.1016\/j.jobe.2022.103993_bib43","doi-asserted-by":"crossref","first-page":"49","DOI":"10.1007\/s40069-012-0005-0","article-title":"Shear-strengthening of reinforced & prestressed concrete beams using FRP: Part II \u2013 experimental investigation","volume":"6","author":"Kang","year":"2012","journal-title":"Int. J. Concrete Struct. Mater."},{"issue":"3","key":"10.1016\/j.jobe.2022.103993_bib44","doi-asserted-by":"crossref","first-page":"134","DOI":"10.1061\/(ASCE)1090-0268(1999)3:3(134)","article-title":"Behavior of retrofitted URM walls under simulated earthquake loading","volume":"3","author":"Ehsani","year":"1999","journal-title":"J. Compos. Construct."},{"issue":"5","key":"10.1016\/j.jobe.2022.103993_bib45","doi-asserted-by":"crossref","first-page":"810","DOI":"10.1061\/(ASCE)CC.1943-5614.0000209","article-title":"Diagonal compression testing of FRP-retrofitted unreinforced clay brick masonry wallettes","volume":"15","author":"Mahmood","year":"2011","journal-title":"J. Compos. Construct."},{"key":"10.1016\/j.jobe.2022.103993_bib46","series-title":"4th International Conference on Advanced Composite Materials in Bridges and Structures. CSCE Calgary, Alberta, Canada, July 20-23","article-title":"A review of retrofitting of unreinforced masonry walls using composites","author":"ElGawady","year":"2004"},{"key":"10.1016\/j.jobe.2022.103993_bib47","series-title":"Structures Congress, Metropolis and beyond","first-page":"1","article-title":"Guide for the design and construction of externally bonded FRP systems for strengthening concrete structures (ACI 440.2 R-02)","author":"Soudki","year":"2005"},{"issue":"8","key":"10.1016\/j.jobe.2022.103993_bib48","doi-asserted-by":"crossref","first-page":"2114","DOI":"10.1016\/j.engstruct.2007.03.023","article-title":"Using traditional and innovative approaches in the seismic evaluation and strengthening of a historic unreinforced masonry synagogue","volume":"30","author":"Paret","year":"2008","journal-title":"Eng. Struct."},{"key":"10.1016\/j.jobe.2022.103993_bib49","series-title":"15th World Conference on Earthquake Engineering, International Association for Earthquake Engineering, 2-10, Tokyo, Japan","article-title":"A comparative study on seismic retrofitting methods for unreinforced masonry brick walls","author":"Amiraslanzadeh","year":"2012"},{"key":"10.1016\/j.jobe.2022.103993_bib50","first-page":"142","article-title":"Quasi-static test of unreinforced brick walls retrofitted with post-tensioning tendons","volume":"36","author":"Liu","year":"2015","journal-title":"J. Build. Struct."},{"issue":"3","key":"10.1016\/j.jobe.2022.103993_bib51","doi-asserted-by":"crossref","first-page":"1487","DOI":"10.1007\/s10518-017-0241-4","article-title":"Seismic retrofit of masonry wall infilled RC frames through external post-tensioning","volume":"16","author":"Soltanzadeh","year":"2018","journal-title":"Bull. Earthq. Eng."},{"issue":"5","key":"10.1016\/j.jobe.2022.103993_bib52","doi-asserted-by":"crossref","first-page":"683","DOI":"10.1002\/eqe.649","article-title":"Performance improvement studies of masonry houses using elastic post\u2010tensioning straps","volume":"36","author":"Turer","year":"2007","journal-title":"Earthq. Eng. Struct. Dynam."},{"key":"10.1016\/j.jobe.2022.103993_bib53","series-title":"First European Conference on Earthquake Engineering and Seismology. Geneva, Switzerland","article-title":"Seismic reinforcement of adobe houses using external polymer mesh","author":"Blondet","year":"2006"},{"key":"10.1016\/j.jobe.2022.103993_bib54","doi-asserted-by":"crossref","first-page":"578","DOI":"10.1016\/j.conbuildmat.2018.02.197","article-title":"Effect of different retrofitting techniques on in-plane behavior of masonry wallettes","volume":"169","author":"Oskouei","year":"2018","journal-title":"Construct. Build. Mater."},{"issue":"6","key":"10.1016\/j.jobe.2022.103993_bib55","first-page":"530","article-title":"Experimental study on in-plane and out-of-Plane behavior of masonry wallettes retrofitted by PP-band meshes","volume":"57","author":"Sathiparan","year":"2005","journal-title":"Seisan Kenkyu"},{"key":"10.1016\/j.jobe.2022.103993_bib56","series-title":"An Introduction to Modelling and Retrofitting of Non-engineered Masonry Buildings under Seismic Loading","author":"Macabuag","year":"2007"},{"issue":"6","key":"10.1016\/j.jobe.2022.103993_bib57","doi-asserted-by":"crossref","first-page":"273","DOI":"10.1680\/stbu.10.00015","article-title":"Seismic retrofitting of non-engineered masonry in rural Nepal","volume":"165","author":"Macabuag","year":"2012","journal-title":"Proc. Inst. Civil Eng. Struct. Build."},{"key":"10.1016\/j.jobe.2022.103993_bib58","series-title":"PP-band Retrofitting Technique: Affordable, Acceptable and Feasible Method for Developing Countries","author":"Meguro","year":"2005"},{"issue":"12","key":"10.1016\/j.jobe.2022.103993_bib59","doi-asserted-by":"crossref","first-page":"3547","DOI":"10.1007\/s10518-016-0006-5","article-title":"The Reticulatus method for shear strengthening of fair-faced masonry","volume":"14","author":"Corradi","year":"2016","journal-title":"Bull. Earthq. Eng."},{"issue":"12","key":"10.1016\/j.jobe.2022.103993_bib60","doi-asserted-by":"crossref","first-page":"4403","DOI":"10.1016\/j.conbuildmat.2011.01.009","article-title":"Shear behavior of unreinforced and reinforced masonry panels subjected to in situ diagonal compression tests","volume":"25","author":"Borri","year":"2011","journal-title":"Construct. Build. Mater."},{"key":"10.1016\/j.jobe.2022.103993_bib61","series-title":"SAHC2014\u20139th International Conference on Structural Analysis of Historical Constructions","article-title":"Flexural out-of-plane retroftting technique for masonry walls in historical constructions","author":"Csikai","year":"2014"},{"issue":"1","key":"10.1016\/j.jobe.2022.103993_bib62","first-page":"30","article-title":"Rubble masonry response under cyclic actions: experimental tests and theoretical models","volume":"2","author":"Fonti","year":"2017","journal-title":"Int. J. Magn. Reson. Imag."},{"issue":"1","key":"10.1016\/j.jobe.2022.103993_bib63","doi-asserted-by":"crossref","first-page":"26","DOI":"10.1080\/13287982.2019.1565288","article-title":"Effect of retrofitting on the structural factors for seismic assessment of unreinforced masonry structures: a review","volume":"20","author":"Dadras Eslamlou","year":"2019","journal-title":"Aust. J. Struct. Eng."},{"issue":"12","key":"10.1016\/j.jobe.2022.103993_bib64","doi-asserted-by":"crossref","first-page":"4338","DOI":"10.1016\/j.conbuildmat.2011.01.008","article-title":"Characterization of repair mortars for the assessment of their compatibility in restoration projects: research and practice","volume":"25","author":"Schueremans","year":"2011","journal-title":"Construct. Build. Mater."},{"key":"10.1016\/j.jobe.2022.103993_bib65","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.conbuildmat.2017.07.210","article-title":"A methodological approach for the selection of compatible and performable restoration mortars in seismic hazard areas","volume":"155","author":"Apostolopoulou","year":"2017","journal-title":"Construct. Build. Mater."},{"key":"10.1016\/j.jobe.2022.103993_bib66","doi-asserted-by":"crossref","first-page":"415","DOI":"10.1016\/j.conbuildmat.2019.07.124","article-title":"Reversible techniques for FRP-confinement of masonry columns","volume":"225","author":"Cascardi","year":"2019","journal-title":"Construct. Build. Mater."},{"issue":"5","key":"10.1016\/j.jobe.2022.103993_bib67","doi-asserted-by":"crossref","first-page":"489","DOI":"10.1061\/(ASCE)1090-0268(2008)12:5(489)","article-title":"Experimental response of externally retrofitted masonry walls subjected to shear loading","volume":"12","author":"Alcaino","year":"2008","journal-title":"J. Compos. Construct."},{"issue":"6","key":"10.1016\/j.jobe.2022.103993_bib68","doi-asserted-by":"crossref","first-page":"665","DOI":"10.1080\/15583058.2011.599916","article-title":"Seismic behavior of unreinforced and confined brick masonry walls before and after ferrocement overlay retrofitting","volume":"6","author":"Ashraf","year":"2012","journal-title":"Int. J. Architect. Herit."},{"key":"10.1016\/j.jobe.2022.103993_bib69","series-title":"Seismic Retrofitting of Unreinforced Masonry Walls by Cable System","author":"Chuang","year":"2004"},{"key":"10.1016\/j.jobe.2022.103993_bib70","series-title":"7th Pacific Conference on Earthquake Engineering, University of Canterbury, Christchurch, New Zealand, 13-15 February","article-title":"Seismic retrofitting of unreinforced masonry walls by FRP strip","author":"Chuang","year":"2003"},{"key":"10.1016\/j.jobe.2022.103993_bib71","series-title":"3rd ICCII, San Francisco, USA","article-title":"Dynamic in-plane behavior of urm wall upgraded with composites","author":"Elgwady","year":"2002"},{"issue":"2","key":"10.1016\/j.jobe.2022.103993_bib72","first-page":"148","article-title":"Aseismic retrofitting of unreinforced masonry walls using FRP","volume":"37","author":"Elgawady","year":"2006","journal-title":"Compos. B Eng."},{"issue":"1","key":"10.1016\/j.jobe.2022.103993_bib73","doi-asserted-by":"crossref","first-page":"226","DOI":"10.1007\/s12205-014-0120-3","article-title":"Seismic in-plane performance of retrofitted masonry walls","volume":"18","author":"Farooq","year":"2014","journal-title":"KSCE J. Civil Eng."},{"issue":"3","key":"10.1016\/j.jobe.2022.103993_bib74","doi-asserted-by":"crossref","first-page":"545","DOI":"10.1007\/s13369-012-0190-9","article-title":"Response of masonry walls strengthened with cfrp and steel strips","volume":"37","author":"Farooq","year":"2012","journal-title":"Arabian J. Sci. Eng."},{"key":"10.1016\/j.jobe.2022.103993_bib75","series-title":"Proceedings of the 27th JSCE Symposium of Earthquake Engineering, Japan","article-title":"Proposal of a new economic retrofitting method for masonry structures","author":"Mayorca","year":"2003"},{"key":"10.1016\/j.jobe.2022.103993_bib76","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1016\/j.compstruct.2013.01.031","article-title":"In-plane behavior of seismically damaged masonry walls repaired with external BFRP","volume":"102","author":"Zhou","year":"2013","journal-title":"Compos. Struct."}],"container-title":["Journal of Building Engineering"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2352710222000067?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2352710222000067?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,5,27]],"date-time":"2026-05-27T16:00:35Z","timestamp":1779897635000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2352710222000067"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,5]]},"references-count":76,"alternative-id":["S2352710222000067"],"URL":"https:\/\/doi.org\/10.1016\/j.jobe.2022.103993","relation":{},"ISSN":["2352-7102"],"issn-type":[{"value":"2352-7102","type":"print"}],"subject":[],"published":{"date-parts":[[2022,5]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Retrofitting of unreinforced masonry structures and considerations for heritage-sensitive constructions","name":"articletitle","label":"Article Title"},{"value":"Journal of Building Engineering","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jobe.2022.103993","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2022 Elsevier Ltd. All rights reserved.","name":"copyright","label":"Copyright"}],"article-number":"103993"}}