{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,3]],"date-time":"2026-10-03T21:42:43Z","timestamp":1791063763664,"version":"4.1.0"},"reference-count":30,"publisher":"Elsevier BV","issue":"1","license":[{"start":{"date-parts":[[2009,1,1]],"date-time":"2009-01-01T00:00:00Z","timestamp":1230768000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2009,1,1]],"date-time":"2009-01-01T00:00:00Z","timestamp":1230768000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Clinical Densitometry"],"published-print":{"date-parts":[[2009,1]]},"DOI":"10.1016\/j.jocd.2008.10.005","type":"journal-article","created":{"date-parts":[[2008,12,14]],"date-time":"2008-12-14T04:41:09Z","timestamp":1229229669000},"page":"17-21","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":24,"title":["Short-Time In Vitro and In Vivo Precision of Direct Digital X-ray Radiogrammetry"],"prefix":"10.1016","volume":"12","author":[{"given":"Mari","family":"Hoff","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alvilde","family":"Dhainaut","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tore K.","family":"Kvien","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kristina","family":"Forslind","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Johan","family":"K\u00e4lvesten","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Glenn","family":"Haugeberg","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.jocd.2008.10.005_bib1","doi-asserted-by":"crossref","first-page":"646","DOI":"10.1016\/0002-9343(93)90218-E","article-title":"Consensus development conference: diagnosis, prophylaxis, and treatment of osteoporosis","volume":"94","author":"Peck","year":"1993","journal-title":"Am J Med"},{"key":"10.1016\/j.jocd.2008.10.005_bib2","doi-asserted-by":"crossref","first-page":"399","DOI":"10.1007\/s00198-008-0560-z","article-title":"European guidance for the diagnosis and management of osteoporosis in postmenopausal women","volume":"19","author":"Kanis","year":"2008","journal-title":"Osteoporos Int"},{"key":"10.1016\/j.jocd.2008.10.005_bib3","doi-asserted-by":"crossref","first-page":"1254","DOI":"10.1136\/bmj.312.7041.1254","article-title":"Meta-analysis of how well measures of bone mineral density predict occurrence of osteoporotic fractures","volume":"312","author":"Marshall","year":"1996","journal-title":"BMJ"},{"key":"10.1016\/j.jocd.2008.10.005_bib4","first-page":"62","article-title":"Peripheral bone densitometry: an old friend revisited","volume":"109","author":"Kleerekoper","year":"1998","journal-title":"Trans Am Clin Climatol Assoc"},{"key":"10.1016\/j.jocd.2008.10.005_bib5","doi-asserted-by":"crossref","first-page":"961","DOI":"10.1007\/s001980170026","article-title":"Estimation of bone mineral density by digital X-ray radiogrammetry: theoretical background and clinical testing","volume":"12","author":"Rosholm","year":"2001","journal-title":"Osteoporos Int"},{"key":"10.1016\/j.jocd.2008.10.005_bib6","doi-asserted-by":"crossref","first-page":"166","DOI":"10.1016\/S0009-9260(60)80012-8","article-title":"The radiological diagnosis of osteoporosis: a new approach","volume":"11","author":"Barnett","year":"1960","journal-title":"Clin Radiol"},{"key":"10.1016\/j.jocd.2008.10.005_bib7","doi-asserted-by":"crossref","first-page":"358","DOI":"10.1007\/s001980200040","article-title":"Digital X-ray radiogrammetry predicts hip, wrist and vertebral fracture risk in elderly women: a prospective analysis from the study of osteoporotic fractures","volume":"13","author":"Bouxsein","year":"2002","journal-title":"Osteoporos Int"},{"key":"10.1016\/j.jocd.2008.10.005_bib8","article-title":"Cortical hand bone loss after one year in early rheumatoid arthritis predicts radiographic hand joint damage at 5 and 10 year follow-up","author":"Hoff","year":"2008","journal-title":"Ann Rheum Dis"},{"key":"10.1016\/j.jocd.2008.10.005_bib9","doi-asserted-by":"crossref","first-page":"1561","DOI":"10.1093\/rheumatology\/keh385","article-title":"Predicting erosive disease in rheumatoid arthritis. A longitudinal study of changes in bone density using digital X-ray radiogrammetry: a pilot study","volume":"43","author":"Stewart","year":"2004","journal-title":"Rheumatology"},{"key":"10.1016\/j.jocd.2008.10.005_bib10","doi-asserted-by":"crossref","first-page":"1293","DOI":"10.1001\/archinte.165.11.1293","article-title":"Reduced loss of hand bone density with prednisolone in early rheumatoid arthritis: results from a randomized placebo-controlled trial","volume":"165","author":"Haugeberg","year":"2005","journal-title":"Arch Intern Med"},{"key":"10.1016\/j.jocd.2008.10.005_bib11","article-title":"Adalimumab therapy reduces hand bone loss in early rheumatoid arthritis: explorative analyses from the PREMIER study","author":"Hoff","year":"2008","journal-title":"Ann Rheum Dis"},{"key":"10.1016\/j.jocd.2008.10.005_bib12","doi-asserted-by":"crossref","first-page":"457","DOI":"10.1007\/s00296-004-0560-z","article-title":"Digital radiogrammetry as a new diagnostic tool for estimation of disease-related osteoporosis in rheumatoid arthritis compared with pQCT","volume":"25","author":"Bottcher","year":"2005","journal-title":"Rheumatol Int"},{"key":"10.1016\/j.jocd.2008.10.005_bib13","doi-asserted-by":"crossref","first-page":"187","DOI":"10.1385\/JCD:8:2:187","article-title":"The precision of digital X-ray radiogrammetry compared with DXA in subjects with normal bone density or osteoporosis","volume":"8","author":"Elliot","year":"2005","journal-title":"J Clin Densitom"},{"key":"10.1016\/j.jocd.2008.10.005_bib14","doi-asserted-by":"crossref","first-page":"330","DOI":"10.1046\/j.1365-2281.2000.00268.x","article-title":"Digital X-ray radiogrammetry: a new appendicular bone densitometric method with high precision","volume":"20","author":"Jorgensen","year":"2000","journal-title":"Clin Physiol"},{"key":"10.1016\/j.jocd.2008.10.005_bib15","doi-asserted-by":"crossref","first-page":"262","DOI":"10.1007\/BF01774016","article-title":"Accurate assessment of precision errors: how to measure the reproducibility of bone densitometry techniques","volume":"5","author":"Gluer","year":"1995","journal-title":"Osteoporos Int"},{"key":"10.1016\/j.jocd.2008.10.005_bib16","doi-asserted-by":"crossref","first-page":"307","DOI":"10.1016\/S0140-6736(86)90837-8","article-title":"Statistical methods for assessing agreement between two methods of clinical measurement","volume":"1","author":"Bland","year":"1986","journal-title":"Lancet"},{"key":"10.1016\/j.jocd.2008.10.005_bib17","doi-asserted-by":"crossref","first-page":"285","DOI":"10.1136\/ard.2002.005678","article-title":"Reproducibility of bone mineral density measurement in daily practice","volume":"63","author":"Lodder","year":"2004","journal-title":"Ann Rheum Dis"},{"key":"10.1016\/j.jocd.2008.10.005_bib18","doi-asserted-by":"crossref","first-page":"105","DOI":"10.1385\/JCD:4:2:105","article-title":"Importance of precision in bone density measurements","volume":"4","author":"Bonnick","year":"2001","journal-title":"J Clin Densitom"},{"key":"10.1016\/j.jocd.2008.10.005_bib19","doi-asserted-by":"crossref","first-page":"3850","DOI":"10.1002\/art.21606","article-title":"Digital X-ray radiogrammetry combined with semiautomated analysis of joint space widths as a new diagnostic approach in rheumatoid arthritis: a cross-sectional and longitudinal study","volume":"52","author":"Bottcher","year":"2005","journal-title":"Arthritis Rheum"},{"key":"10.1016\/j.jocd.2008.10.005_bib20","doi-asserted-by":"crossref","first-page":"R81","DOI":"10.1186\/ar2280","article-title":"Hand bone loss as an outcome measure in established rheumatoid arthritis: 2-year observational study comparing cortical and total bone loss","volume":"9","author":"Hoff","year":"2007","journal-title":"Arthritis Res Ther"},{"issue":"Suppl 2","key":"10.1016\/j.jocd.2008.10.005_bib21","first-page":"563","article-title":"Short time precision assessed with digital X-ray radiogrammetry in healthy individuals and rheumatoid arthritis patients","volume":"67","author":"Hoff","year":"2008","journal-title":"Ann Rheum Dis"},{"key":"10.1016\/j.jocd.2008.10.005_bib22","doi-asserted-by":"crossref","first-page":"1513","DOI":"10.1136\/ard.2006.067652","article-title":"Hand bone densitometry: a more sensitive standard for the assessment of early bone damage in rheumatoid arthritis","volume":"66","author":"Haugeberg","year":"2007","journal-title":"Ann Rheum Dis"},{"key":"10.1016\/j.jocd.2008.10.005_bib23","doi-asserted-by":"crossref","first-page":"715","DOI":"10.1016\/j.rdc.2005.07.013","article-title":"Value of dual-energy x-ray absorptiometry as a diagnostic and assessment tool in early rheumatoid arthritis","volume":"31","author":"Haugeberg","year":"2005","journal-title":"Rheum Dis Clin North Am"},{"key":"10.1016\/j.jocd.2008.10.005_bib24","doi-asserted-by":"crossref","first-page":"400","DOI":"10.1007\/s001980070106","article-title":"Detailed analyses of periarticular osteoporosis in rheumatoid arthritis","volume":"11","author":"Alenfeld","year":"2000","journal-title":"Osteoporos Int"},{"key":"10.1016\/j.jocd.2008.10.005_bib25","doi-asserted-by":"crossref","first-page":"1449","DOI":"10.1359\/jbmr.1999.14.8.1449","article-title":"Individual smallest detectable difference in bone mineral density measurements","volume":"14","author":"Ravaud","year":"1999","journal-title":"J. Bone Miner Res"},{"key":"10.1016\/j.jocd.2008.10.005_bib26","doi-asserted-by":"crossref","first-page":"605","DOI":"10.1093\/qjmed\/hcn022","article-title":"DXA scanning in clinical practice","volume":"101","author":"El Maghraoui","year":"2008","journal-title":"QJM"},{"key":"10.1016\/j.jocd.2008.10.005_bib27","doi-asserted-by":"crossref","first-page":"698","DOI":"10.1007\/s00256-004-0861-z","article-title":"The impact of technical conditions of X-ray imaging on reproducibility and precision of digital computer-assisted X-ray radiogrammetry (DXR)","volume":"33","author":"Malich","year":"2004","journal-title":"Skeletal Radiol"},{"key":"10.1016\/j.jocd.2008.10.005_bib28","doi-asserted-by":"crossref","first-page":"87","DOI":"10.1385\/JCD:8:1:087","article-title":"Influence of image-capturing parameters on digital X-ray radiogrammetry","volume":"8","author":"Bottcher","year":"2005","journal-title":"J Clin Densitom"},{"key":"10.1016\/j.jocd.2008.10.005_bib29","doi-asserted-by":"crossref","first-page":"135","DOI":"10.1007\/s002230001204","article-title":"Response of cortical bone to antiresorptive treatment","volume":"68","author":"Hyldstrup","year":"2001","journal-title":"Calcif Tissue Int"},{"key":"10.1016\/j.jocd.2008.10.005_bib30","doi-asserted-by":"crossref","first-page":"1952","DOI":"10.1359\/jbmr.1999.14.11.1952","article-title":"Monitoring skeletal changes by radiological techniques","volume":"14","author":"Gluer","year":"1999","journal-title":"J Bone Miner Res"}],"container-title":["Journal of Clinical Densitometry"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1094695008004800?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1094695008004800?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,21]],"date-time":"2025-10-21T21:35:42Z","timestamp":1761082542000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1094695008004800"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2009,1]]},"references-count":30,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2009,1]]}},"alternative-id":["S1094695008004800"],"URL":"https:\/\/doi.org\/10.1016\/j.jocd.2008.10.005","relation":{},"ISSN":["1094-6950"],"issn-type":[{"value":"1094-6950","type":"print"}],"subject":[],"published":{"date-parts":[[2009,1]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Short-Time In Vitro and In Vivo Precision of Direct Digital X-ray Radiogrammetry","name":"articletitle","label":"Article Title"},{"value":"Journal of Clinical Densitometry","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jocd.2008.10.005","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2009 The International Society for Clinical Densitometry. Published by Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}