{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,21]],"date-time":"2026-02-21T21:03:03Z","timestamp":1771707783589,"version":"3.50.1"},"reference-count":35,"publisher":"Elsevier BV","issue":"1","license":[{"start":{"date-parts":[[2015,1,1]],"date-time":"2015-01-01T00:00:00Z","timestamp":1420070400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2015,1,1]],"date-time":"2015-01-01T00:00:00Z","timestamp":1420070400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Clinical Densitometry"],"published-print":{"date-parts":[[2015,1]]},"DOI":"10.1016\/j.jocd.2014.06.002","type":"journal-article","created":{"date-parts":[[2014,7,31]],"date-time":"2014-07-31T05:45:22Z","timestamp":1406785522000},"page":"109-116","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":18,"title":["Intraoperative Mechanical Measurement of Bone Quality With the DensiProbe"],"prefix":"10.1016","volume":"18","author":[{"given":"Sven","family":"Hoppe","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Michael","family":"Uhlmann","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Robert","family":"Schwyn","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Norbert","family":"Suhm","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lorin M.","family":"Benneker","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"issue":"1","key":"10.1016\/j.jocd.2014.06.002_bib1","doi-asserted-by":"crossref","first-page":"77","DOI":"10.1007\/s00198-006-0206-y","article-title":"Epidemiology, treatment and costs of osteoporosis in Germany\u2014the BoneEVA Study","volume":"18","author":"Haussler","year":"2007","journal-title":"Osteoporos Int"},{"issue":"6","key":"10.1016\/j.jocd.2014.06.002_bib2","doi-asserted-by":"crossref","first-page":"607","DOI":"10.1097\/BRS.0b013e3181bc9470","article-title":"DensiProbe Spine: a novel instrument for intraoperative measurement of bone density in transpedicular screw fixation","volume":"35","author":"Deckelmann","year":"2010","journal-title":"Spine (Phila Pa 1976)"},{"issue":"1","key":"10.1016\/j.jocd.2014.06.002_bib3","doi-asserted-by":"crossref","first-page":"26","DOI":"10.1302\/0301-620X.72B1.2298790","article-title":"Intertrochanteric femoral fractures. Mechanical failure after internal fixation","volume":"72","author":"Davis","year":"1990","journal-title":"J Bone Joint Surg Br"},{"issue":"3 Suppl","key":"10.1016\/j.jocd.2014.06.002_bib4","doi-asserted-by":"crossref","first-page":"S13","DOI":"10.1007\/s00198-002-1345-4","article-title":"Bone strength and its determinants","volume":"14","author":"Ammann","year":"2003","journal-title":"Osteoporos Int"},{"issue":"2","key":"10.1016\/j.jocd.2014.06.002_bib5","doi-asserted-by":"crossref","first-page":"383","DOI":"10.1359\/jbmr.2003.18.2.383","article-title":"Determinants of bone strength","volume":"18","author":"Kiebzak","year":"2003","journal-title":"J Bone Miner Res"},{"issue":"15","key":"10.1016\/j.jocd.2014.06.002_bib6","doi-asserted-by":"crossref","first-page":"1889","DOI":"10.1001\/jama.288.15.1889","article-title":"Clinical use of bone densitometry: scientific review","volume":"288","author":"Cummings","year":"2002","journal-title":"JAMA"},{"issue":"3","key":"10.1016\/j.jocd.2014.06.002_bib7","doi-asserted-by":"crossref","first-page":"415","DOI":"10.1016\/j.ejrad.2009.04.074","article-title":"Quantitative computed tomography","volume":"71","author":"Adams","year":"2009","journal-title":"Eur J Radiol"},{"issue":"1","key":"10.1016\/j.jocd.2014.06.002_bib8","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.clinthera.2004.12.020","article-title":"The bone quality framework: determinants of bone strength and their interrelationships, and implications for osteoporosis management","volume":"27","author":"Felsenberg","year":"2005","journal-title":"Clin Ther"},{"issue":"1","key":"10.1016\/j.jocd.2014.06.002_bib9","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1007\/s002239900178","article-title":"Discrimination of spinal fracture with various bone mineral measurements","volume":"60","author":"Ito","year":"1997","journal-title":"Calcif Tissue Int"},{"issue":"8","key":"10.1016\/j.jocd.2014.06.002_bib10","doi-asserted-by":"crossref","first-page":"1326","DOI":"10.1359\/jbmr.080316","article-title":"Proximal femoral structure and the prediction of hip fracture in men: a large prospective study using QCT","volume":"23","author":"Black","year":"2008","journal-title":"J Bone Miner Res"},{"issue":"1","key":"10.1016\/j.jocd.2014.06.002_bib11","doi-asserted-by":"crossref","first-page":"49","DOI":"10.1016\/S8756-3282(99)00093-9","article-title":"Prediction of the strength of the elderly proximal femur by bone mineral density and quantitative ultrasound measurements of the heel and tibia","volume":"25","author":"Bouxsein","year":"1999","journal-title":"Bone"},{"issue":"7","key":"10.1016\/j.jocd.2014.06.002_bib12","doi-asserted-by":"crossref","first-page":"1529","DOI":"10.1109\/TUFFC.2008.829","article-title":"The clinical use of quantitative ultrasound (QUS) in the detection and management of osteoporosis","volume":"55","author":"Hans","year":"2008","journal-title":"IEEE Trans Ultrason Ferroelectr Freq Control"},{"issue":"11","key":"10.1016\/j.jocd.2014.06.002_bib13","doi-asserted-by":"crossref","first-page":"398","DOI":"10.4329\/wjr.v5.i11.398","article-title":"Screening and early diagnosis of osteoporosis through X-ray and ultrasound based techniques","volume":"5","author":"Pisani","year":"2013","journal-title":"World J Radiol"},{"issue":"5","key":"10.1016\/j.jocd.2014.06.002_bib14","doi-asserted-by":"crossref","first-page":"404","DOI":"10.1016\/j.spinee.2008.07.001","article-title":"Pullout strength of pedicle screws augmented with particulate calcium phosphate: an experimental study","volume":"9","author":"Hashemi","year":"2009","journal-title":"Spine J"},{"issue":"12","key":"10.1016\/j.jocd.2014.06.002_bib15","doi-asserted-by":"crossref","first-page":"1673","DOI":"10.1097\/00007632-199309000-00016","article-title":"Pedicle screw pullout strength. Correlation with insertional torque","volume":"18","author":"Zdeblick","year":"1993","journal-title":"Spine (Phila Pa 1976)"},{"issue":"17","key":"10.1016\/j.jocd.2014.06.002_bib16","doi-asserted-by":"crossref","first-page":"1962","DOI":"10.1097\/00007632-199609010-00004","article-title":"The role of imaging and in situ biomechanical testing in assessing pedicle screw pull-out strength","volume":"21","author":"Myers","year":"1996","journal-title":"Spine (Phila Pa 1976)"},{"issue":"2","key":"10.1016\/j.jocd.2014.06.002_bib17","doi-asserted-by":"crossref","first-page":"133","DOI":"10.1007\/s00776-004-0883-3","article-title":"Insertional torque of the lumbar pedicle screw during surgery","volume":"10","author":"Ozawa","year":"2005","journal-title":"J Orthop Sci"},{"issue":"5","key":"10.1016\/j.jocd.2014.06.002_bib18","doi-asserted-by":"crossref","first-page":"513","DOI":"10.1016\/j.spinee.2004.02.006","article-title":"Pedicle screw fixation strength: pullout versus insertional torque","volume":"4","author":"Inceoglu","year":"2004","journal-title":"Spine J"},{"issue":"15","key":"10.1016\/j.jocd.2014.06.002_bib19","doi-asserted-by":"crossref","first-page":"2240","DOI":"10.1097\/00007632-199311000-00016","article-title":"Stability of transpedicle screwing for the osteoporotic spine. An in\u00a0vitro study of the mechanical stability","volume":"18","author":"Okuyama","year":"1993","journal-title":"Spine (Phila Pa 1976)"},{"issue":"6","key":"10.1016\/j.jocd.2014.06.002_bib20","doi-asserted-by":"crossref","first-page":"469","DOI":"10.1007\/s00402-006-0265-8","article-title":"Mechanical torque measurement predicts load to implant cut-out: a biomechanical study investigating DHS anchorage in femoral heads","volume":"127","author":"Suhm","year":"2007","journal-title":"Arch Orthop Trauma Surg"},{"issue":"6","key":"10.1016\/j.jocd.2014.06.002_bib21","doi-asserted-by":"crossref","first-page":"613","DOI":"10.1007\/s00402-008-0566-1","article-title":"Quantification of bone strength by intraoperative torque measurement: a technical note","volume":"128","author":"Suhm","year":"2008","journal-title":"Arch Orthop Trauma Surg"},{"issue":"12","key":"10.1016\/j.jocd.2014.06.002_bib22","doi-asserted-by":"crossref","first-page":"1183","DOI":"10.3113\/FAI.2009.1183","article-title":"Intraoperative mechanical bone strength determination in tibiotalocalcaneal fusion: a biomechanical investigation","volume":"30","author":"Klos","year":"2009","journal-title":"Foot Ankle Int"},{"issue":"2","key":"10.1016\/j.jocd.2014.06.002_bib23","doi-asserted-by":"crossref","first-page":"206","DOI":"10.1055\/s-0030-1250106","volume":"149","author":"Klos","year":"2011","journal-title":"Z Orthop Unfall"},{"issue":"10","key":"10.1016\/j.jocd.2014.06.002_bib24","doi-asserted-by":"crossref","first-page":"1712","DOI":"10.1016\/j.injury.2012.06.014","article-title":"Mechanical torque measurement for in\u00a0vivo quantification of bone strength in the proximal femur","volume":"43","author":"Mueller","year":"2012","journal-title":"Injury"},{"key":"10.1016\/j.jocd.2014.06.002_bib25","doi-asserted-by":"crossref","first-page":"172","DOI":"10.2174\/1874325001307010172","article-title":"Mechanical quantification of local bone quality in the humeral head: a feasibility study","volume":"7","author":"Scola","year":"2013","journal-title":"Open Orthop J"},{"issue":"10","key":"10.1016\/j.jocd.2014.06.002_bib26","doi-asserted-by":"crossref","first-page":"1327","DOI":"10.1016\/j.injury.2013.05.008","article-title":"Biomechanical in\u00a0vitro assessment of screw augmentation in locked plating of proximal humerus fractures","volume":"44","author":"R\u00f6derer","year":"2013","journal-title":"Injury"},{"issue":"2","key":"10.1016\/j.jocd.2014.06.002_bib27","first-page":"77","article-title":"Mechanical torque measurement in the proximal femur correlates to failure load and bone mineral density ex\u00a0vivo","volume":"5","author":"Grote","year":"2013","journal-title":"Orthop Rev (Pavia)"},{"issue":"10","key":"10.1016\/j.jocd.2014.06.002_bib28","doi-asserted-by":"crossref","first-page":"1223","DOI":"10.1016\/j.spinee.2013.06.067","article-title":"DensiProbe Spine: an intraoperative measurement of bone quality in spinal instrumentation. A clinical feasibility study","volume":"13","author":"Popp","year":"2013","journal-title":"Spine J"},{"issue":"9","key":"10.1016\/j.jocd.2014.06.002_bib29","doi-asserted-by":"crossref","first-page":"e1134","DOI":"10.3928\/01477447-20130821-14","article-title":"Mechanical assessment of local bone quality to predict failure of locked plating in a proximal humerus fracture model","volume":"36","author":"R\u00f6derer","year":"2013","journal-title":"Orthopedics"},{"issue":"5","key":"10.1016\/j.jocd.2014.06.002_bib30","doi-asserted-by":"crossref","first-page":"438","DOI":"10.1097\/00005131-199310000-00006","article-title":"Healing complications after internal fixation of trochanteric hip fractures: the prognostic value of osteoporosis","volume":"7","author":"Barrios","year":"1993","journal-title":"J Orthop Trauma"},{"issue":"4","key":"10.1016\/j.jocd.2014.06.002_bib31","doi-asserted-by":"crossref","first-page":"375","DOI":"10.1016\/0021-9290(94)90014-0","article-title":"The relationship between the structural and orthogonal compressive properties of trabecular bone","volume":"27","author":"Goulet","year":"1994","journal-title":"J Biomech"},{"key":"10.1016\/j.jocd.2014.06.002_bib32","doi-asserted-by":"crossref","first-page":"748393","DOI":"10.1155\/2014\/748393","article-title":"Designs and techniques that improve the pullout strength of pedicle screws in osteoporotic vertebrae: current status","volume":"2014","author":"Shea","year":"2014","journal-title":"Biomed Res Int"},{"issue":"1","key":"10.1016\/j.jocd.2014.06.002_bib33","doi-asserted-by":"crossref","first-page":"54","DOI":"10.1016\/j.spinee.2010.09.024","article-title":"Instrumentation of the osteoporotic spine: biomechanical and clinical considerations","volume":"11","author":"Ponnusamy","year":"2011","journal-title":"Spine J"},{"issue":"3 Suppl","key":"10.1016\/j.jocd.2014.06.002_bib34","doi-asserted-by":"crossref","first-page":"S35","DOI":"10.1016\/j.injury.2007.08.009","article-title":"Locking plate technology and its role in osteoporotic fractures","volume":"38","author":"Miranda","year":"2007","journal-title":"Injury"},{"issue":"6","key":"10.1016\/j.jocd.2014.06.002_bib35","doi-asserted-by":"crossref","first-page":"E384","DOI":"10.1097\/BRS.0000000000000198","article-title":"Influence of screw augmentation in posterior dynamic and rigid stabilization systems in osteoporotic lumbar vertebrae: a biomechanical cadaveric study","volume":"39","author":"Hoppe","year":"2014","journal-title":"Spine (Phila Pa 1976)"}],"container-title":["Journal of Clinical Densitometry"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1094695014001759?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1094695014001759?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,21]],"date-time":"2025-10-21T21:38:49Z","timestamp":1761082729000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1094695014001759"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,1]]},"references-count":35,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2015,1]]}},"alternative-id":["S1094695014001759"],"URL":"https:\/\/doi.org\/10.1016\/j.jocd.2014.06.002","relation":{},"ISSN":["1094-6950"],"issn-type":[{"value":"1094-6950","type":"print"}],"subject":[],"published":{"date-parts":[[2015,1]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Intraoperative Mechanical Measurement of Bone Quality With the DensiProbe","name":"articletitle","label":"Article Title"},{"value":"Journal of Clinical Densitometry","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jocd.2014.06.002","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2015 The International Society for Clinical Densitometry. Published by Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}