{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,5]],"date-time":"2026-11-05T06:56:27Z","timestamp":1793861787321,"version":"4.6.1"},"reference-count":32,"publisher":"Elsevier BV","issue":"4","license":[{"start":{"date-parts":[[2019,10,1]],"date-time":"2019-10-01T00:00:00Z","timestamp":1569888000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2019,10,1]],"date-time":"2019-10-01T00:00:00Z","timestamp":1569888000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Clinical Densitometry"],"published-print":{"date-parts":[[2019,10]]},"DOI":"10.1016\/j.jocd.2019.09.001","type":"journal-article","created":{"date-parts":[[2019,9,7]],"date-time":"2019-09-07T10:59:45Z","timestamp":1567853985000},"page":"472-483","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":73,"title":["Cross-calibration, Least Significant Change and Quality Assurance in Multiple Dual-Energy X-ray Absorptiometry Scanner Environments: 2019 ISCD Official Position"],"prefix":"10.1016","volume":"22","author":[{"given":"Lawrence G.","family":"Jankowski","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sarah","family":"Warner","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ken","family":"Gaither","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Leon","family":"Lenchik","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bo","family":"Fan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ying","family":"Lu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"John","family":"Shepherd","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"issue":"6","key":"10.1016\/j.jocd.2019.09.001_bib0001","doi-asserted-by":"crossref","first-page":"1125","DOI":"10.1359\/jbmr.2003.18.6.1125","article-title":"The Food and Drug Administration's Osteoporosis Guidance Document: past, present, and future","volume":"18","author":"Colman","year":"2003","journal-title":"J Bone Miner Res"},{"issue":"5","key":"10.1016\/j.jocd.2019.09.001_bib0002","doi-asserted-by":"crossref","first-page":"461","DOI":"10.1007\/PL00004171","article-title":"Multinational, placebo-controlled, randomized trial of the effects of alendronate on bone density and fracture risk in postmenopausal women with low bone mass: results of the FOSIT study. Fosamax International Trial Study Group","volume":"9","author":"Pols","year":"1999","journal-title":"Osteoporos Int"},{"issue":"14","key":"10.1016\/j.jocd.2019.09.001_bib0003","doi-asserted-by":"crossref","first-page":"1344","DOI":"10.1001\/jama.282.14.1344","article-title":"Effects of risedronate treatment on vertebral and nonvertebral fractures in women with postmenopausal osteoporosis: a randomized controlled trial. Vertebral Efficacy With Risedronate Therapy (VERT) Study Group","volume":"282","author":"Harris","year":"1999","journal-title":"JAMA"},{"issue":"2","key":"10.1016\/j.jocd.2019.09.001_bib0004","doi-asserted-by":"crossref","first-page":"103","DOI":"10.1007\/s00223-002-2011-8","article-title":"The efficacy and tolerability of risedronate once a week for the treatment of postmenopausal osteoporosis","volume":"71","author":"Brown","year":"2002","journal-title":"Calcif Tissue Int"},{"issue":"8","key":"10.1016\/j.jocd.2019.09.001_bib0005","doi-asserted-by":"crossref","first-page":"1137","DOI":"10.1002\/jbmr.5650090802","article-title":"The diagnosis of osteoporosis","volume":"9","author":"Kanis","year":"1994","journal-title":"J Bone Miner Res"},{"issue":"10","key":"10.1016\/j.jocd.2019.09.001_bib0006","doi-asserted-by":"crossref","first-page":"1503","DOI":"10.1002\/jbmr.5650091002","article-title":"Universal standardization for dual x-ray absorptiometry: patient and phantom cross-calibration results","volume":"9","author":"Genant","year":"1994","journal-title":"J Bone Miner Res"},{"issue":"9","key":"10.1016\/j.jocd.2019.09.001_bib0007","doi-asserted-by":"crossref","first-page":"1463","DOI":"10.1359\/jbmr.1997.12.9.1463","article-title":"Universal standardization of bone density measurements: a method with optimal properties for calibration among several instruments","volume":"12","author":"Hui","year":"1997","journal-title":"J Bone Miner Res"},{"issue":"3","key":"10.1016\/j.jocd.2019.09.001_bib0008","doi-asserted-by":"crossref","first-page":"423","DOI":"10.1016\/j.ejrad.2006.11.034","article-title":"Standardization of spine and hip BMD measurements in different DXA devices","volume":"62","author":"Ozdemir","year":"2007","journal-title":"Eur J Radiol"},{"issue":"3","key":"10.1016\/j.jocd.2019.09.001_bib0009","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1891\/1061-3749.16.3.155","article-title":"Importance of cross-calibration when replacing DXA scanners: QDR4500W and Discovery Wi","volume":"16","author":"Covey","year":"2008","journal-title":"J Nurs Meas"},{"issue":"4","key":"10.1016\/j.jocd.2019.09.001_bib0010","doi-asserted-by":"crossref","first-page":"496","DOI":"10.1016\/j.jocd.2013.09.009","article-title":"Cross-calibration of a GE iDXA and Prodigy for total and regional body bone parameters: the importance of using cross-calibration equations for longitudinal monitoring after a system upgrade","volume":"17","author":"Rhodes","year":"2014","journal-title":"J Clin Densitom"},{"issue":"2","key":"10.1016\/j.jocd.2019.09.001_bib0011","doi-asserted-by":"crossref","first-page":"237","DOI":"10.1016\/j.jocd.2008.02.001","article-title":"Comparing BMD results between two similar DXA systems using the generalized least significant change","volume":"11","author":"Shepherd","year":"2008","journal-title":"J Clin Densitom"},{"issue":"11","key":"10.1016\/j.jocd.2019.09.001_bib0012","doi-asserted-by":"crossref","first-page":"1597","DOI":"10.1007\/s00198-008-0594-2","article-title":"Improved precision with Hologic Apex software","volume":"19","author":"Fan","year":"2008","journal-title":"Osteoporos Int"},{"issue":"5","key":"10.1016\/j.jocd.2019.09.001_bib0013","doi-asserted-by":"crossref","first-page":"1504","DOI":"10.1007\/s00330-014-3509-y","article-title":"Prevalence and type of errors in dual-energy x-ray absorptiometry","volume":"25","author":"Messina","year":"2015","journal-title":"Eur Radiol"},{"issue":"4","key":"10.1016\/j.jocd.2019.09.001_bib0014","first-page":"117","article-title":"Common mistakes in the dual-energy x-ray absorptiometry (DXA) in Turkey. A retrospective descriptive multicenter study","volume":"59","author":"Karahan","year":"2016","journal-title":"Acta Medica (Hradec Kral)"},{"issue":"4","key":"10.1016\/j.jocd.2019.09.001_bib0015","doi-asserted-by":"crossref","first-page":"858","DOI":"10.1002\/jbmr.1534","article-title":"Central DXA utilization shifts from office-based to hospital-based settings among Medicare beneficiaries in the wake of reimbursement changes","volume":"27","author":"Zhang","year":"2012","journal-title":"J Bone Miner Res"},{"issue":"1","key":"10.1016\/j.jocd.2019.09.001_bib0016","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1016\/j.jocd.2006.05.005","article-title":"Cross-calibration and minimum precision standards for dual-energy x-ray absorptiometry: the 2005 ISCD Official Positions","volume":"9","author":"Shepherd","year":"2006","journal-title":"J Clin Densitom"},{"issue":"3","key":"10.1016\/j.jocd.2019.09.001_bib0017","doi-asserted-by":"crossref","first-page":"249","DOI":"10.1016\/j.jocd.2007.05.002","article-title":"A generalized least significant change for individuals measured on different DXA systems","volume":"10","author":"Shepherd","year":"2007","journal-title":"J Clin Densitom"},{"issue":"4","key":"10.1016\/j.jocd.2019.09.001_bib0018","doi-asserted-by":"crossref","first-page":"399","DOI":"10.1016\/j.jocd.2006.06.003","article-title":"Standards and measurements for assessing bone health-workshop report co-sponsored by the International Society for Clinical Densitometry (ISCD) and the National Institute of Standards and Technology (NIST)","volume":"9","author":"Bennett","year":"2006","journal-title":"J Clin Densitom"},{"issue":"3","key":"10.1016\/j.jocd.2019.09.001_bib0019","doi-asserted-by":"crossref","first-page":"404","DOI":"10.1016\/j.jocd.2008.12.006","article-title":"Comparing BMD results between 2 similar DXA systems using the generalized least significant change","volume":"12","author":"Blake","year":"2009","journal-title":"J Clin Densitom"},{"issue":"1","key":"10.1016\/j.jocd.2019.09.001_bib0020","doi-asserted-by":"crossref","first-page":"86","DOI":"10.1016\/j.jocd.2013.09.011","article-title":"A cross-calibration study of the GE-Lunar iDXA and prodigy for the assessment of lumbar spine and total hip bone parameters via three statistical methods","volume":"18","author":"Hind","year":"2015","journal-title":"J Clin Densitom"},{"issue":"2","key":"10.1016\/j.jocd.2019.09.001_bib0021","doi-asserted-by":"crossref","first-page":"281","DOI":"10.1016\/j.jocd.2017.01.007","article-title":"Cross-calibrated dual-energy x-ray absorptiometry scanners demonstrate systematic bias in pediatric and young adult females","volume":"21","author":"Dowthwaite","year":"2018","journal-title":"J Clin Densitom"},{"issue":"4","key":"10.1016\/j.jocd.2019.09.001_bib0022","doi-asserted-by":"crossref","first-page":"513","DOI":"10.1007\/s00198-006-0280-1","article-title":"A study of the long-term precision of dual-energy x-ray absorptiometry bone densitometers and implications for the validity of the least-significant-change calculation","volume":"18","author":"Hangartner","year":"2007","journal-title":"Osteoporos Int"},{"issue":"2","key":"10.1016\/j.jocd.2019.09.001_bib0023","doi-asserted-by":"crossref","first-page":"108","DOI":"10.1016\/j.jocd.2011.03.001","article-title":"Long-term versus short-term precision of dual-energy x-ray absorptiometry scans and the impact on interpreting change in bone mineral density at follow-up","volume":"14","author":"Kiebzak","year":"2011","journal-title":"J Clin Densitom"},{"issue":"11","key":"10.1016\/j.jocd.2019.09.001_bib0024","doi-asserted-by":"crossref","first-page":"1515","DOI":"10.1007\/s00198-007-0382-4","article-title":"Precision and accuracy of measuring changes in bone mineral density by dual-energy x-ray absorptiometry","volume":"18","author":"Tothill","year":"2007","journal-title":"Osteoporos Int"},{"issue":"11","key":"10.1016\/j.jocd.2019.09.001_bib0025","doi-asserted-by":"crossref","first-page":"1673","DOI":"10.1007\/s00198-006-0170-6","article-title":"Minimum sample size requirements for bone density precision assessment produce inconsistency in clinical monitoring","volume":"17","author":"Leslie","year":"2006","journal-title":"Osteoporos Int"},{"issue":"2","key":"10.1016\/j.jocd.2019.09.001_bib0026","doi-asserted-by":"crossref","first-page":"199","DOI":"10.1359\/jbmr.071019","article-title":"Factors affecting short-term bone density precision assessment and the effect on patient monitoring","volume":"23","author":"Leslie","year":"2008","journal-title":"J Bone Miner Res"},{"issue":"11","key":"10.1016\/j.jocd.2019.09.001_bib0027","doi-asserted-by":"crossref","first-page":"1589","DOI":"10.1007\/s00198-008-0615-1","article-title":"Optimal decision criterion for detecting change in bone mineral density during serial monitoring: a Bayesian approach","volume":"19","author":"Sadatsafavi","year":"2008","journal-title":"Osteoporos Int"},{"issue":"16","key":"10.1016\/j.jocd.2019.09.001_bib0028","doi-asserted-by":"crossref","first-page":"1889","DOI":"10.1002\/(SICI)1097-0258(19970830)16:16<1889::AID-SIM607>3.0.CO;2-V","article-title":"Comparative calibration without a gold standard","volume":"16","author":"Lu","year":"1997","journal-title":"Stat Med"},{"issue":"2","key":"10.1016\/j.jocd.2019.09.001_bib0029","doi-asserted-by":"crossref","first-page":"276","DOI":"10.1016\/j.jocd.2007.10.001","article-title":"In vivo and in vitro comparison of densitometers in the NOREPOS study","volume":"11","author":"Omsland","year":"2008","journal-title":"J Clin Densitom"},{"issue":"3","key":"10.1016\/j.jocd.2019.09.001_bib0030","doi-asserted-by":"crossref","first-page":"287","DOI":"10.1016\/j.jocd.2006.02.006","article-title":"Cross calibration of DXA as part of an equipment replacement program","volume":"9","author":"Pearson","year":"2006","journal-title":"J Clin Densitom"},{"issue":"4","key":"10.1016\/j.jocd.2019.09.001_bib0031","doi-asserted-by":"crossref","first-page":"413","DOI":"10.1385\/JCD:7:4:413","article-title":"Reproducibility of fan-beam DXA measurements in adults and phantoms","volume":"7","author":"Ellis","year":"2004","journal-title":"J Clin Densitom"},{"issue":"5","key":"10.1016\/j.jocd.2019.09.001_bib0032","doi-asserted-by":"crossref","first-page":"348","DOI":"10.1007\/s00223-004-0050-z","article-title":"Towards standardization of dual X-ray absorptiometry (DXA) at the forearm: a common region of interest (ROI) improves the comparability among DXA devices","volume":"76","author":"Prevrhal","year":"2005","journal-title":"Calcif Tissue Int"}],"container-title":["Journal of Clinical Densitometry"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S109469501930188X?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S109469501930188X?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,21]],"date-time":"2025-10-21T21:42:50Z","timestamp":1761082970000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S109469501930188X"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,10]]},"references-count":32,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2019,10]]}},"alternative-id":["S109469501930188X"],"URL":"https:\/\/doi.org\/10.1016\/j.jocd.2019.09.001","relation":{},"ISSN":["1094-6950"],"issn-type":[{"value":"1094-6950","type":"print"}],"subject":[],"published":{"date-parts":[[2019,10]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Cross-calibration, Least Significant Change and Quality Assurance in Multiple Dual-Energy X-ray Absorptiometry Scanner Environments: 2019 ISCD Official Position","name":"articletitle","label":"Article Title"},{"value":"Journal of Clinical Densitometry","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jocd.2019.09.001","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2019 The International Society for Clinical Densitometry. Published by Elsevier Inc.","name":"copyright","label":"Copyright"}]}}