{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,22]],"date-time":"2025-10-22T21:02:04Z","timestamp":1761166924538,"version":"build-2065373602"},"reference-count":20,"publisher":"Elsevier BV","issue":"4","license":[{"start":{"date-parts":[[2021,10,1]],"date-time":"2021-10-01T00:00:00Z","timestamp":1633046400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2021,10,1]],"date-time":"2021-10-01T00:00:00Z","timestamp":1633046400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"funder":[{"DOI":"10.13039\/501100008164","name":"Muscular Dystrophy UK","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100008164","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100001266","name":"Action Duchenne","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100001266","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100014589","name":"Chief Scientist Office, Scottish Government Health and Social Care Directorate","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100014589","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Clinical Densitometry"],"published-print":{"date-parts":[[2021,10]]},"DOI":"10.1016\/j.jocd.2021.01.009","type":"journal-article","created":{"date-parts":[[2021,1,22]],"date-time":"2021-01-22T06:36:25Z","timestamp":1611297385000},"page":"622-629","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"title":["Observer Agreement of Vertebral Fracture Grading Using Dual Energy Absorptiometry Vertebral Fracture Assessment in Duchenne Muscular Dystrophy"],"prefix":"10.1016","volume":"24","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-3499-6366","authenticated-orcid":false,"given":"Hannah","family":"Martin","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shuko","family":"Joseph","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"S.","family":"Shepherd","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2936-0168","authenticated-orcid":false,"given":"Marina","family":"Di Marco","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jennifer","family":"Dunne","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Iain","family":"Horrocks","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"S. Faisal","family":"Ahmed","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sze Choong","family":"Wong","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"issue":"1","key":"10.1016\/j.jocd.2021.01.009_bib0001","doi-asserted-by":"crossref","first-page":"59","DOI":"10.1016\/j.nmd.2018.09.005","article-title":"Fractures and bone health monitoring in boys with Duchenne muscular dystrophy managed within the Scottish Muscle Network","volume":"29","author":"Joseph","year":"2019","journal-title":"Neuromuscul Disord"},{"issue":"1","key":"10.1016\/j.jocd.2021.01.009_bib0002","doi-asserted-by":"crossref","first-page":"71","DOI":"10.1097\/01241398-200001000-00016","article-title":"Bone mineral density and fractures in boys with Duchenne muscular dystrophy","volume":"20","author":"Larson","year":"2000","journal-title":"J Pediatr Orthop"},{"issue":"4","key":"10.1016\/j.jocd.2021.01.009_bib0003","doi-asserted-by":"crossref","first-page":"353","DOI":"10.1177\/000992280304200408","article-title":"Vertebral fractures in boys with Duchenne muscular dystrophy","volume":"42","author":"Bothwell","year":"2003","journal-title":"Clin Pediatr (Phila)"},{"issue":"9","key":"10.1016\/j.jocd.2021.01.009_bib0004","doi-asserted-by":"crossref","first-page":"3408","DOI":"10.1210\/JC.2015-2176","article-title":"Incident vertebral fractures in children with leukemia during the four years following diagnosis","volume":"100","author":"Cummings","year":"2015","journal-title":"J Clin Endocrinol Metab"},{"issue":"4","key":"10.1016\/j.jocd.2021.01.009_bib0005","doi-asserted-by":"crossref","first-page":"347","DOI":"10.1016\/S1474-4422(18)30025-5","article-title":"Diagnosis and management of Duchenne muscular dystrophy, part 2: respiratory, cardiac, bone health, and orthopaedic management","volume":"17","author":"Birnkrant","year":"2018","journal-title":"Lancet Neurol"},{"key":"10.1016\/j.jocd.2021.01.009_bib0006","doi-asserted-by":"crossref","first-page":"255","DOI":"10.1016\/j.bone.2015.07.032","article-title":"A critical appraisal of vertebral fracture assessment in paediatrics","volume":"81","author":"Kyriakou","year":"2015","journal-title":"Bone"},{"key":"10.1016\/j.jocd.2021.01.009_bib0007","doi-asserted-by":"crossref","first-page":"168","DOI":"10.1016\/j.bone.2017.01.006","article-title":"Vertebral fractures assessment in children: evaluation of DXA imaging versus conventional spine radiography","volume":"97","author":"Crabtree","year":"2017","journal-title":"Bone"},{"issue":"5","key":"10.1016\/j.jocd.2021.01.009_bib0008","doi-asserted-by":"crossref","first-page":"2188","DOI":"10.1007\/s00330-016-4556-3","article-title":"Diagnostic accuracy of DXA compared to conventional spine radiographs for the detection of vertebral fractures in children","volume":"27","author":"Adiotomre","year":"2017","journal-title":"Eur Radiol"},{"key":"10.1016\/j.jocd.2021.01.009_bib0009","doi-asserted-by":"crossref","DOI":"10.1016\/j.jocd.2019.07.002","article-title":"The utility of DXA assessment at the forearm, proximal femur, and lateral distal femur, and vertebral fracture assessment in the Pediatric population: the 2019 Official Pediatric Positions of the ISCD","author":"Weber","year":"2019","journal-title":"J Clin Densitom"},{"issue":"1","key":"10.1016\/j.jocd.2021.01.009_bib0010","doi-asserted-by":"crossref","first-page":"172","DOI":"10.1002\/jbmr.2935","article-title":"Amalgamated reference data for size-adjusted bone densitometry measurements in 3598 children and young adults\u2014the ALPHABET study","volume":"32","author":"Crabtree","year":"2017","journal-title":"J Bone Miner Res"},{"issue":"9","key":"10.1016\/j.jocd.2021.01.009_bib0011","doi-asserted-by":"crossref","first-page":"1137","DOI":"10.1002\/jbmr.5650080915","article-title":"Vertebral fracture assessment using a semiquantitative technique","volume":"8","author":"Genant","year":"1993","journal-title":"J Bone Miner Res"},{"key":"10.1016\/j.jocd.2021.01.009_bib0012","doi-asserted-by":"crossref","first-page":"284","DOI":"10.1037\/1040-3590.6.4.284","article-title":"Guidelines, criteria, and rules of thumb for evaluating normed and standardized assessment instruments in psychology","volume":"6","author":"Cicchetti","year":"1994","journal-title":"Psychol Assess"},{"key":"10.1016\/j.jocd.2021.01.009_bib0013","first-page":"159","article-title":"The measurement of observer agreement for categorical data","volume":"33","author":"Landis","year":"1977","journal-title":"Source: Biometrics"},{"issue":"3","key":"10.1016\/j.jocd.2021.01.009_bib0014","doi-asserted-by":"crossref","first-page":"353","DOI":"10.1016\/j.bone.2007.05.012","article-title":"Bone densitometry in the diagnosis of vertebral fractures in children: accuracy of vertebral fracture assessment","volume":"41","author":"M\u00e4yr\u00e4np\u00e4\u00e4","year":"2007","journal-title":"Bone"},{"issue":"4","key":"10.1016\/j.jocd.2021.01.009_bib0015","doi-asserted-by":"crossref","first-page":"307","DOI":"10.1007\/s00223-015-9960-1","article-title":"Reliability of vertebral fractures assessment (VFA) in children with osteogenesis imperfecta","volume":"96","author":"Diacinti","year":"2015","journal-title":"Calcif Tissue Int"},{"issue":"4","key":"10.1016\/j.jocd.2021.01.009_bib0016","doi-asserted-by":"crossref","first-page":"457","DOI":"10.1007\/s00247-013-2837-4","article-title":"Observer agreement in pediatric semiquantitative vertebral fracture diagnosis","volume":"44","author":"Siminoski","year":"2014","journal-title":"Pediatr Radiol"},{"issue":"10","key":"10.1016\/j.jocd.2021.01.009_bib0017","doi-asserted-by":"crossref","first-page":"904.e11","DOI":"10.1016\/j.crad.2017.04.010","article-title":"Evaluation of a semi-automated software program for the identification of vertebral fractures in children","volume":"72","author":"Alqahtani","year":"2017","journal-title":"Clin Radiol"},{"issue":"6","key":"10.1016\/j.jocd.2021.01.009_bib0018","doi-asserted-by":"crossref","first-page":"536","DOI":"10.1007\/s001980050182","article-title":"Morphometric X-ray absorptiometry and morphometric radiography of the spine: a comparison of analysis precision in normal and osteoporotic subjects","volume":"9","author":"Rea","year":"1999","journal-title":"Osteoporos Int"},{"issue":"10","key":"10.1016\/j.jocd.2021.01.009_bib0019","doi-asserted-by":"crossref","first-page":"2677","DOI":"10.1007\/s00198-011-1530-4","article-title":"Intra-and inter-reader reliability of semi-automated quantitative morphometry measurements and vertebral fracture assessment using lateral scout views from computed tomography","volume":"22","author":"Kim","year":"2011","journal-title":"Osteoporos Int"},{"issue":"3","key":"10.1016\/j.jocd.2021.01.009_bib0020","doi-asserted-by":"crossref","first-page":"283","DOI":"10.1007\/s00247-018-4279-5","article-title":"Diagnosis of osteoporotic vertebral fractures in children","volume":"49","author":"Alqahtani","year":"2019","journal-title":"Pediatr Radiol"}],"container-title":["Journal of Clinical Densitometry"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S109469502100010X?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S109469502100010X?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,21]],"date-time":"2025-10-21T21:43:34Z","timestamp":1761083014000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S109469502100010X"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,10]]},"references-count":20,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2021,10]]}},"alternative-id":["S109469502100010X"],"URL":"https:\/\/doi.org\/10.1016\/j.jocd.2021.01.009","relation":{},"ISSN":["1094-6950"],"issn-type":[{"type":"print","value":"1094-6950"}],"subject":[],"published":{"date-parts":[[2021,10]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Observer Agreement of Vertebral Fracture Grading Using Dual Energy Absorptiometry Vertebral Fracture Assessment in Duchenne Muscular Dystrophy","name":"articletitle","label":"Article Title"},{"value":"Journal of Clinical Densitometry","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jocd.2021.01.009","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Crown Copyright \u00a9 2021 Published by Elsevier Inc. on behalf of The International Society for Clinical Densitometry.","name":"copyright","label":"Copyright"}]}}