{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,26]],"date-time":"2026-09-26T04:53:49Z","timestamp":1790398429366,"version":"4.1.0"},"reference-count":21,"publisher":"Elsevier BV","issue":"1","license":[{"start":{"date-parts":[[2024,1,1]],"date-time":"2024-01-01T00:00:00Z","timestamp":1704067200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2024,1,1]],"date-time":"2024-01-01T00:00:00Z","timestamp":1704067200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2023,12,15]],"date-time":"2023-12-15T00:00:00Z","timestamp":1702598400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Cardiovascular Magnetic Resonance"],"published-print":{"date-parts":[[2024]]},"DOI":"10.1016\/j.jocmr.2023.100004","type":"journal-article","created":{"date-parts":[[2024,3,15]],"date-time":"2024-03-15T05:02:02Z","timestamp":1710478922000},"page":"100004","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":8,"title":["Inter-scanner comparability of Z-scores for native myocardial T1 and T2 mapping"],"prefix":"10.1016","volume":"26","author":[{"given":"Saad","family":"Razzaq","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Leila","family":"Haririsanati","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Katerina","family":"Eyre","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ria","family":"Garg","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael","family":"Chetrit","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Matthias G.","family":"Friedrich","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"issue":"5","key":"10.1016\/j.jocmr.2023.100004_bib1","doi-asserted-by":"crossref","first-page":"701","DOI":"10.1002\/jmri.1880040513","article-title":"A novel fast T1-mapping method","volume":"4","author":"Tong","year":"1994","journal-title":"J Magn Reson Imaging"},{"issue":"1","key":"10.1016\/j.jocmr.2023.100004_bib2","doi-asserted-by":"crossref","first-page":"206","DOI":"10.1002\/(SICI)1522-2594(199907)42:1<206::AID-MRM28>3.0.CO;2-Q","article-title":"Fast T1 mapping on a whole-body scanner","volume":"42","author":"Deichmann","year":"1999","journal-title":"Magn Reson Med"},{"issue":"8","key":"10.1016\/j.jocmr.2023.100004_bib3","doi-asserted-by":"crossref","DOI":"10.1016\/S0730-725X(99)00025-9","article-title":"A fast 3D look-locker method for volumetric T1 mapping","volume":"17","author":"Henderson","year":"1999","journal-title":"Magn Reson Imaging"},{"issue":"1","key":"10.1016\/j.jocmr.2023.100004_bib4","doi-asserted-by":"crossref","first-page":"113","DOI":"10.3348\/kjr.2017.18.1.113","article-title":"Myocardial T1 and T2 mapping: techniques and clinical applications","volume":"18","author":"Kim","year":"2017","journal-title":"Korean J Radiol"},{"issue":"8","key":"10.1016\/j.jocmr.2023.100004_bib5","doi-asserted-by":"crossref","first-page":"891","DOI":"10.1016\/j.jacc.2010.11.013","article-title":"Assessment of myocardial fibrosis with cardiovascular magnetic resonance","volume":"57","author":"Mewton","year":"2011","journal-title":"J Am Coll Cardiol"},{"issue":"1","key":"10.1016\/j.jocmr.2023.100004_bib6","volume":"19","author":"Messroghli","year":"2017","journal-title":"J Cardiovasc Magn Reson"},{"issue":"2","key":"10.1016\/j.jocmr.2023.100004_bib7","doi-asserted-by":"crossref","first-page":"353","DOI":"10.1081\/JCMR-120019418","article-title":"T1 mapping in patients with acute myocardial infarction","volume":"5","author":"Messroghli","year":"2003","journal-title":"J Cardiovasc Magn Reson"},{"key":"10.1016\/j.jocmr.2023.100004_bib8","doi-asserted-by":"crossref","first-page":"34","DOI":"10.1002\/mrm.21272","article-title":"Myocardial T1 mapping: application to patients with acute and chronic myocardial infarction","volume":"58","author":"Messroghli","year":"2007","journal-title":"Magn Reson Med"},{"issue":"1","key":"10.1016\/j.jocmr.2023.100004_bib9","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/1532-429X-15-92","article-title":"Myocardial T1 mapping and extracellular volume quantification: a Society for Cardiovascular Magnetic Resonance (SCMR) and CMR Working Group of the European Society of Cardiology consensus statement","volume":"15","author":"Moon","year":"2013","journal-title":"J Cardiovasc Magn Reson"},{"issue":"4","key":"10.1016\/j.jocmr.2023.100004_bib10","doi-asserted-by":"crossref","first-page":"1081","DOI":"10.1002\/jmri.21119","article-title":"Optimization and validation of a fully-integrated pulse sequence for modified look-locker inversion-recovery (MOLLI) T1 mapping of the heart","volume":"26","author":"Messroghli","year":"2007","journal-title":"J Magn Reson Imaging"},{"issue":"1","key":"10.1016\/j.jocmr.2023.100004_bib11","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1186\/1532-429X-15-27","article-title":"Variability and homogeneity of cardiovascular magnetic resonance myocardial T2-mapping in volunteers compared to patients with edema","volume":"15","author":"Wassmuth","year":"2013","journal-title":"J Cardiovasc Magn Reson"},{"key":"10.1016\/j.jocmr.2023.100004_bib12","series-title":"Obesity [Internet]","article-title":"What childhood obesity prevention programmes work? A systematic review and meta\u2010analysis","author":"Wang","year":"2015"},{"issue":"12","key":"10.1016\/j.jocmr.2023.100004_bib13","doi-asserted-by":"crossref","DOI":"10.1371\/journal.pone.0208362","article-title":"Optimisation of children z-score calculation based on new statistical techniques","volume":"13","author":"Martinez-Millana","year":"2018","journal-title":"PLoS One"},{"issue":"2","key":"10.1016\/j.jocmr.2023.100004_bib14","doi-asserted-by":"crossref","first-page":"438","DOI":"10.1002\/mrm.27935","article-title":"Fast myocardial T1 mapping using cardiac motion correction","volume":"83","author":"Becker","year":"2020","journal-title":"Magn Reson Med"},{"key":"10.1016\/j.jocmr.2023.100004_bib15","doi-asserted-by":"crossref","DOI":"10.3389\/fcvm.2021.768245","article-title":"MOCOnet: robust motion correction of cardiovascular magnetic resonance t1 mapping using convolutional neural networks","volume":"8","author":"Gonzales","year":"2021","journal-title":"Front Cardiovasc Med"},{"issue":"1","key":"10.1016\/j.jocmr.2023.100004_bib16","doi-asserted-by":"crossref","DOI":"10.1186\/s12968-019-0595-7","article-title":"Z-score mapping for standardized analysis and reporting of cardiovascular magnetic resonance modified Look-Locker inversion recovery (MOLLI) T1 data: normal behavior and validation in patients with amyloidosis","volume":"22","author":"Kranzusch","year":"2020","journal-title":"J Cardiovasc Magn Reson"},{"issue":"4","key":"10.1016\/j.jocmr.2023.100004_bib17","doi-asserted-by":"crossref","first-page":"1060","DOI":"10.1002\/jmri.25659","article-title":"Robust universal nonrigid motion correction framework for first-pass cardiac MR perfusion imaging","volume":"46","author":"Benovoy","year":"2017","journal-title":"J Magn Reson Imaging"},{"key":"10.1016\/j.jocmr.2023.100004_bib18","unstructured":"Cerqueira M.D. \u2026 Cardiac Imaging: Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart: a statement for healthcare professionals \u2026. Circulation [Internet]. 2002; Available from: https:\/\/ci.nii.ac.jp\/naid\/20000766392\/."},{"issue":"2","key":"10.1016\/j.jocmr.2023.100004_bib19","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1016\/j.jcm.2016.02.012","article-title":"A guideline of selecting and reporting intraclass correlation coefficients for reliability research","volume":"15","author":"Koo","year":"2016","journal-title":"J Chiropr Med"},{"issue":"2","key":"10.1016\/j.jocmr.2023.100004_bib20","doi-asserted-by":"crossref","first-page":"377","DOI":"10.1148\/rg.342125121","article-title":"Myocardial T1 mapping: techniques and potential applications","volume":"34","author":"Burt","year":"2014","journal-title":"Radiographics"},{"issue":"6","key":"10.1016\/j.jocmr.2023.100004_bib21","doi-asserted-by":"crossref","first-page":"1594","DOI":"10.1148\/rg.346140030","article-title":"Mapping the future of cardiac MR imaging: case-based review of T1 and T2 mapping techniques","volume":"34","author":"Hamlin","year":"2014","journal-title":"Radiographics"}],"container-title":["Journal of Cardiovascular Magnetic Resonance"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1097664723001692?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1097664723001692?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2024,9,18]],"date-time":"2024-09-18T14:33:53Z","timestamp":1726670033000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1097664723001692"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024]]},"references-count":21,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2024]]}},"alternative-id":["S1097664723001692"],"URL":"https:\/\/doi.org\/10.1016\/j.jocmr.2023.100004","relation":{},"ISSN":["1097-6647"],"issn-type":[{"value":"1097-6647","type":"print"}],"subject":[],"published":{"date-parts":[[2024]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Inter-scanner comparability of Z-scores for native myocardial T1 and T2 mapping","name":"articletitle","label":"Article Title"},{"value":"Journal of Cardiovascular Magnetic Resonance","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jocmr.2023.100004","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"name":"copyright","label":"Copyright"}],"article-number":"100004"}}