{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,14]],"date-time":"2026-08-14T16:42:57Z","timestamp":1786725777791,"version":"build-2736575974"},"reference-count":16,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","license":[{"start":{"date-parts":[[2020,1,1]],"date-time":"2020-01-01T00:00:00Z","timestamp":1577836800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2019,1,26]],"date-time":"2019-01-26T00:00:00Z","timestamp":1548460800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2020,1]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose:<\/jats:title>\n                    <jats:p>To review the published data about changes in the anterior chamber depth (ACD) in keratoconus patients.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>In this systematic review and meta-analysis of observational studies, we reviewed the available and relevant literature on anterior segment changes in keratoconic eyes, with a special focus on the ACD, an effective factor in many surgical methods. Articles published up to December 2017 were identified in the following data sources: PubMed, Scopus, Ovid, ISI, ScienceDirect, and Google Scholar. Databases were comprehensively searched using the key words \u201cAnterior Chamber Depth AND Anterior segment AND Keratoconus\u201d.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>A total of 496 studies including these key words were detected. Four hundred fifty-three studies were excluded, and overall 16 studies which precisely described the change in ACD were included in the literature review. The results show that with respect to the applied device, there was a statistically significant difference in ACD between keratoconic eyes and normal eyes except for Galilei analyzer.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>Summarizing the results of studies, this review revealed that ACD is significantly deeper in keratoconic eyes as compared with normal eyes, which could be explained by the steeper corneal curvature.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1016\/j.joco.2019.01.010","type":"journal-article","created":{"date-parts":[[2019,2,13]],"date-time":"2019-02-13T10:36:17Z","timestamp":1550054177000},"page":"94-98","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":11,"title":["Comparison of Anterior Chamber Depth between Normal and Keratoconic Eyes"],"prefix":"10.4103","volume":"32","author":[{"given":"Hassan","family":"Hashemi","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"AbbasAli","family":"Yekta","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Negareh","family":"Yazdani","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hadi","family":"Ostadimoghaddam","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mehdi","family":"Khabazkhoob","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-14-20240910","doi-asserted-by":"crossref","first-page":"803","DOI":"10.1097\/OPX.0000000000000295","article-title":"Assessment of anterior segment parameters of keratoconus eyes in an Australian population","volume":"91","author":"Sahebjada","year":"2014","journal-title":"Optom Vis Sci"},{"key":"R2-14-20240910","doi-asserted-by":"crossref","first-page":"120","DOI":"10.1097\/ICL.0b013e31819cf5a6","article-title":"Comparison of anterior chamber depth of normal and keratoconus eyes using scheimpflug photography","volume":"35","author":"Edmonds","year":"2009","journal-title":"Eye Contact Lens"},{"key":"R3-14-20240910","doi-asserted-by":"crossref","first-page":"191","DOI":"10.1016\/j.clae.2013.01.005","article-title":"Anterior segment characteristics of keratoconus eyes in a sample of Asian population","volume":"36","author":"Abolbashari","year":"2013","journal-title":"Cont Lens Anterior Eye"},{"key":"R4-14-20240910","doi-asserted-by":"crossref","first-page":"1101","DOI":"10.1016\/j.jcrs.2009.12.046","article-title":"Anterior chamber characteristics of keratoconus assessed by rotating scheimpflug imaging","volume":"36","author":"Kov\u00e1cs","year":"2010","journal-title":"J Cataract Refract Surg"},{"key":"R5-14-20240910","doi-asserted-by":"crossref","first-page":"582","DOI":"10.1016\/j.jcrs.2013.08.061","article-title":"Comparative evaluation of dual scheimpflug imaging parameters in keratoconus, early keratoconus, and normal eyes","volume":"40","author":"Reddy","year":"2014","journal-title":"J Cataract Refract Surg"},{"key":"R6-14-20240910","doi-asserted-by":"crossref","first-page":"e24","DOI":"10.1016\/j.clae.2014.11.030","article-title":"Corneal and anterior chamber parameters in keratoconus: Which are the best indicators of disease progression?","volume":"38","author":"Gispets","year":"2015","journal-title":"Contact Lens Anterior Eye"},{"key":"R7-14-20240910","doi-asserted-by":"crossref","first-page":"673","DOI":"10.1016\/j.ophtha.2009.09.023","article-title":"Corneal biomechanical metrics and anterior segment parameters in mild keratoconus","volume":"117","author":"Fontes","year":"2010","journal-title":"Ophthalmology"},{"key":"R8-14-20240910","doi-asserted-by":"crossref","first-page":"1708","DOI":"10.1016\/j.jcrs.2007.06.020","article-title":"Evaluation of anterior segment parameters in keratoconic eyes measured with the pentacam system","volume":"33","author":"Emre","year":"2007","journal-title":"J Cataract Refract Surg"},{"key":"R9-14-20240910","doi-asserted-by":"crossref","first-page":"219","DOI":"10.1016\/j.clae.2013.04.001","article-title":"Comparison of normal and keratoconic corneas by galilei dual-Scheimpflug Analyzer","volume":"36","author":"Demir","year":"2013","journal-title":"Cont Lens Anterior Eye"},{"key":"R10-14-20240910","doi-asserted-by":"crossref","first-page":"390","DOI":"10.1016\/j.ajo.2006.11.030","article-title":"Evaluation of keratoconus in Asians: Role of orbscan II and tomey TMS-2 corneal topography","volume":"143","author":"Lim","year":"2007","journal-title":"Am J Ophthalmol"},{"key":"R11-14-20240910","doi-asserted-by":"crossref","first-page":"56","DOI":"10.1097\/ICO.0b013e3181e2ba61","article-title":"Biometric evaluation of keratoconic eyes with slit lamp-adapted optical coherence tomography","volume":"30","author":"Aurich","year":"2011","journal-title":"Cornea"},{"key":"R12-14-20240910","doi-asserted-by":"crossref","first-page":"466","DOI":"10.1016\/j.clae.2016.05.003","article-title":"The variability of corneal and anterior segment parameters in keratoconus","volume":"39","author":"Mas-Aixala","year":"2016","journal-title":"Cont Lens Anterior Eye"},{"key":"R13-14-20240910","doi-asserted-by":"crossref","first-page":"1547","DOI":"10.1007\/s00417-013-2261-3","article-title":"Comparative analysis of the relationship between anterior and posterior corneal shape analyzed by scheimpflug photography in normal and keratoconus eyes","volume":"251","author":"Montalb\u00e1n","year":"2013","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"R14-14-20240910","doi-asserted-by":"crossref","first-page":"603","DOI":"10.2147\/OPTH.S102683","article-title":"Comparison of scheimpflug imaging parameters between steep and keratoconic corneas of Caucasian eyes","volume":"10","author":"Huseynova","year":"2016","journal-title":"Clin Ophthalmol"},{"key":"R15-14-20240910","doi-asserted-by":"crossref","first-page":"1116","DOI":"10.1016\/j.jcrs.2010.12.049","article-title":"Evaluation of scheimpflug imaging parameters in subclinical keratoconus, keratoconus, and normal eyes","volume":"37","author":"U\u00e7akhan","year":"2011","journal-title":"J Cataract Refract Surg"},{"key":"R16-14-20240910","doi-asserted-by":"crossref","first-page":"106","DOI":"10.1016\/j.joco.2016.06.003","article-title":"Anterior segment characteristics in normal and keratoconus eyes evaluated with a combined scheimpflug\/placido corneal imaging device","volume":"28","author":"Safarzadeh","year":"2016","journal-title":"J Curr Ophthalmol"}],"container-title":["Journal of Current Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2452232518301628?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2452232518301628?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.ovid.com\/10.1016\/j.joco.2019.01.010","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,14]],"date-time":"2026-08-14T16:25:28Z","timestamp":1786724728000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.1016\/j.joco.2019.01.010"}},"subtitle":["A Systematic Review and Meta-Analysis"],"short-title":[],"issued":{"date-parts":[[2020,1]]},"references-count":16,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2020]]}},"URL":"https:\/\/doi.org\/10.1016\/j.joco.2019.01.010","relation":{},"ISSN":["2452-2325"],"issn-type":[{"value":"2452-2325","type":"print"}],"subject":[],"published":{"date-parts":[[2020,1]]}}}