{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,27]],"date-time":"2026-10-27T21:47:44Z","timestamp":1793137664408,"version":"4.5.0"},"reference-count":38,"publisher":"Elsevier BV","issue":"4","license":[{"start":{"date-parts":[[2018,4,1]],"date-time":"2018-04-01T00:00:00Z","timestamp":1522540800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":["clinicalkey.jp","clinicalkey.com","jendodon.com","clinicalkey.es","clinicalkey.com.au","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Endodontics"],"published-print":{"date-parts":[[2018,4]]},"DOI":"10.1016\/j.joen.2017.12.011","type":"journal-article","created":{"date-parts":[[2018,2,2]],"date-time":"2018-02-02T01:26:25Z","timestamp":1517534785000},"page":"648-653","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":55,"title":["Cyclic Fatigue Resistance of Heat-treated Nickel-titanium Instruments after Immersion in Sodium Hypochlorite and\/or Sterilization"],"prefix":"10.1016","volume":"44","author":[{"given":"Eugenio","family":"Pedull\u00e0","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Angela","family":"Benites","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Giusy M.","family":"La Rosa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gianluca","family":"Plotino","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nicola M.","family":"Grande","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ernesto","family":"Rapisarda","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Luigi","family":"Generali","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.joen.2017.12.011_bib1","doi-asserted-by":"crossref","first-page":"346","DOI":"10.1016\/S0099-2399(88)80196-1","article-title":"An initial investigation of the bending and torsional properties of Nitinol root canal files","volume":"14","author":"Walia","year":"1988","journal-title":"J Endod"},{"key":"10.1016\/j.joen.2017.12.011_bib2","doi-asserted-by":"crossref","first-page":"432","DOI":"10.1097\/00004770-200406000-00014","article-title":"Comparison of hand stainless steel and nickel titanium rotary instrumentation: a clinical study","volume":"30","author":"Sch\u00e4fer","year":"2004","journal-title":"J Endod"},{"key":"10.1016\/j.joen.2017.12.011_bib3","doi-asserted-by":"crossref","first-page":"147","DOI":"10.1016\/j.joen.2009.09.037","article-title":"Cyclic fatigue and fracture characteristics of ground and twisted nickel-titanium rotary files","volume":"36","author":"Kim","year":"2010","journal-title":"J Endod"},{"key":"10.1016\/j.joen.2017.12.011_bib4","doi-asserted-by":"crossref","first-page":"52","DOI":"10.1016\/j.joen.2006.09.004","article-title":"The effect of operational speed on the fracture of nickel-titanium rotary instruments","volume":"33","author":"Kitchens","year":"2007","journal-title":"J Endod"},{"key":"10.1016\/j.joen.2017.12.011_bib5","doi-asserted-by":"crossref","first-page":"527","DOI":"10.1016\/j.joen.2011.12.018","article-title":"Effect from cyclic fatigue of nickel-titanium rotary files on torsional resistance","volume":"38","author":"Kim","year":"2012","journal-title":"J Endod"},{"key":"10.1016\/j.joen.2017.12.011_bib6","doi-asserted-by":"crossref","first-page":"1205","DOI":"10.1016\/j.joen.2010.02.015","article-title":"Effects of raw material and rotational speed on the cyclic fatigue of ProFile Vortex rotary instruments","volume":"36","author":"Gao","year":"2010","journal-title":"J Endod"},{"key":"10.1016\/j.joen.2017.12.011_bib7","doi-asserted-by":"crossref","first-page":"258","DOI":"10.1016\/j.joen.2012.10.025","article-title":"Influence of continuous or reciprocating motion on cyclic fatigue resistance of 4 different nickel-titanium rotary instruments","volume":"39","author":"Pedull\u00e0","year":"2013","journal-title":"J Endod"},{"key":"10.1016\/j.joen.2017.12.011_bib8","doi-asserted-by":"crossref","first-page":"24","DOI":"10.1111\/aej.12067","article-title":"Comparison of cyclic fatigue resistance of novel nickel-titanium rotary instruments","volume":"41","author":"Capar","year":"2015","journal-title":"Aust Endod J"},{"key":"10.1016\/j.joen.2017.12.011_bib9","doi-asserted-by":"crossref","first-page":"505","DOI":"10.1590\/1679-775720130083","article-title":"Experimental evaluation of cyclic fatigue resistance of four different nickel-titanium instruments after immersion in sodium hypochlorite and\/or sterilization","volume":"21","author":"Bulem","year":"2013","journal-title":"J Appl Oral Sci"},{"key":"10.1016\/j.joen.2017.12.011_bib10","doi-asserted-by":"crossref","first-page":"1003","DOI":"10.1016\/j.joen.2008.05.007","article-title":"Fatigue resistance of engine-driven rotary nickel-titanium instruments produced by new manufacturing methods","volume":"34","author":"Gambarini","year":"2008","journal-title":"J Endod"},{"key":"10.1016\/j.joen.2017.12.011_bib11","doi-asserted-by":"crossref","first-page":"163","DOI":"10.1016\/j.joen.2012.11.005","article-title":"Current challenges and concepts of the thermomechanical treatment of nickel-titanium instruments","volume":"39","author":"Shen","year":"2013","journal-title":"J Endod"},{"key":"10.1016\/j.joen.2017.12.011_bib12","doi-asserted-by":"crossref","first-page":"101","DOI":"10.1016\/j.joen.2012.08.010","article-title":"Torsion and bending properties of shape memory and superelastic nickel-titanium rotary instruments","volume":"39","author":"Ninan","year":"2013","journal-title":"J Endod"},{"key":"10.1016\/j.joen.2017.12.011_bib13","doi-asserted-by":"crossref","first-page":"301","DOI":"10.5395\/rde.2017.42.4.301","article-title":"The effects of autoclave sterilization on the cyclic fatigue resistance of ProTaper Universal, ProTaper Next, and ProTaper Gold nickel-titanium instruments","volume":"42","author":"\u00d6zy\u00fcrek","year":"2017","journal-title":"Restor Dent Endod"},{"key":"10.1016\/j.joen.2017.12.011_bib14","doi-asserted-by":"crossref","first-page":"709","DOI":"10.1111\/j.1365-2591.2006.01138.x","article-title":"Influence of sterilization on mechanical properties and fatigue resistance of nickel-titanium rotary endodontic instruments","volume":"39","author":"Viana","year":"2006","journal-title":"Int Endod J"},{"key":"10.1016\/j.joen.2017.12.011_bib15","doi-asserted-by":"crossref","first-page":"843","DOI":"10.1016\/S0099-2399(98)80015-0","article-title":"Effect of sterilization on cyclic fatigue of rotary NiTi endodontic instruments","volume":"24","author":"Mize","year":"1998","journal-title":"J Endod"},{"key":"10.1016\/j.joen.2017.12.011_bib16","doi-asserted-by":"crossref","first-page":"222","DOI":"10.1016\/j.joen.2011.10.017","article-title":"Experimental evaluation on the influence of autoclave sterilization on the cyclic fatigue of new nickel-titanium rotary instruments","volume":"38","author":"Plotino","year":"2012","journal-title":"J Endod"},{"key":"10.1016\/j.joen.2017.12.011_bib17","doi-asserted-by":"crossref","first-page":"72","DOI":"10.1016\/j.joen.2010.09.011","article-title":"Multiple autoclave cycle effects on cyclic fatigue of nickel-titanium rotary files produced by new manufacturing methods","volume":"37","author":"Hilfer","year":"2011","journal-title":"J Endod"},{"key":"10.1016\/j.joen.2017.12.011_bib18","doi-asserted-by":"crossref","first-page":"724","DOI":"10.1046\/j.1365-2591.2003.00709.x","article-title":"The effect of cleaning procedures on fracture properties and corrosion of NiTi files","volume":"36","author":"O\u2019Hoy","year":"2003","journal-title":"Int Endod J"},{"key":"10.1016\/j.joen.2017.12.011_bib19","doi-asserted-by":"crossref","first-page":"121","DOI":"10.1111\/j.1365-2842.1983.tb00106.x","article-title":"The chloride corrosion behaviour of four orthodontic wires","volume":"10","author":"Sarkar","year":"1983","journal-title":"J Oral Rehabil"},{"key":"10.1016\/j.joen.2017.12.011_bib20","doi-asserted-by":"crossref","first-page":"589","DOI":"10.1016\/j.joen.2007.01.007","article-title":"Effect of immersion in sodium hypochlorite on torque and fatigue resistance of nickel-titanium instruments","volume":"33","author":"Peters","year":"2007","journal-title":"J Endod"},{"key":"10.1016\/j.joen.2017.12.011_bib21","doi-asserted-by":"crossref","first-page":"1139","DOI":"10.1016\/j.joen.2011.04.008","article-title":"Cyclic fatigue resistance of three different nickel-titanium instruments after immersion in sodium hypochlorite","volume":"37","author":"Pedull\u00e0","year":"2011","journal-title":"J Endod"},{"key":"10.1016\/j.joen.2017.12.011_bib22","doi-asserted-by":"crossref","first-page":"331","DOI":"10.4317\/medoral.17413","article-title":"Electrochemical corrosion assessment of RaCe and Mtwo rotary nickle-titanium instruments after clinical use and sterilization","volume":"17","author":"Shahi","year":"2012","journal-title":"Med Oral Patol Oral Cir Bucal"},{"key":"10.1016\/j.joen.2017.12.011_bib23","doi-asserted-by":"crossref","first-page":"34","DOI":"10.4103\/0970-7212.351839","article-title":"Effect of cleaning and sterilization procedures on Niti rotary files \u2013 an SEM and EDS study","volume":"18","author":"Sood","year":"2006","journal-title":"Endodontology"},{"key":"10.1016\/j.joen.2017.12.011_bib24","doi-asserted-by":"crossref","first-page":"271","DOI":"10.1016\/0030-4220(71)90230-1","article-title":"A comparison of canal preparations in straight and curved root canals","volume":"32","author":"Schneider","year":"1971","journal-title":"Oral Surg"},{"key":"10.1016\/j.joen.2017.12.011_bib25","doi-asserted-by":"crossref","first-page":"55","DOI":"10.2174\/1874210600903010055","article-title":"Cyclic fatigue of different nickel-titanium rotary instruments: a comparative study","volume":"3","author":"Testarelli","year":"2009","journal-title":"Open Dent J"},{"key":"10.1016\/j.joen.2017.12.011_bib26","doi-asserted-by":"crossref","first-page":"60","DOI":"10.1016\/j.tripleo.2009.08.009","article-title":"Influence of size and taper of artificial canals on the trajectory of NiTi rotary instruments in cyclic fatigue studies","volume":"109","author":"Plotino","year":"2010","journal-title":"Oral Surg Oral Med Oral Pathol Oral Radiol Endod"},{"key":"10.1016\/j.joen.2017.12.011_bib27","doi-asserted-by":"crossref","first-page":"802","DOI":"10.1111\/j.1365-2591.2005.01020.x","article-title":"Defects in ProTaper S1 instruments after clinical use: fractographic examination","volume":"38","author":"Cheung","year":"2005","journal-title":"Int Endod J"},{"key":"10.1016\/j.joen.2017.12.011_bib28","doi-asserted-by":"crossref","first-page":"133","DOI":"10.1016\/j.joen.2008.10.013","article-title":"Defects in nickel-titanium instruments after clinical use: part 2\u2014fractographic analysis of fractured surface in a cohort study","volume":"35","author":"Shen","year":"2009","journal-title":"J Endod"},{"key":"10.1016\/j.joen.2017.12.011_bib29","doi-asserted-by":"crossref","first-page":"197","DOI":"10.1111\/j.1834-7819.1995.tb05637.x","article-title":"The use of autoclaves in the dental surgery","volume":"40","author":"Savage","year":"1995","journal-title":"Aust Dent J"},{"key":"10.1016\/j.joen.2017.12.011_bib30","doi-asserted-by":"crossref","first-page":"990","DOI":"10.1111\/iej.12550","article-title":"Effect of autoclave sterilization on the cyclic fatigue resistance of thermally treated nickel-titanium instruments","volume":"49","author":"Zhao","year":"2016","journal-title":"Int Endod J"},{"key":"10.1016\/j.joen.2017.12.011_bib31","series-title":"Integrated Biomaterial Science","first-page":"308","article-title":"Degradation processes on metallic surfaces","author":"Angelini","year":"2002"},{"key":"10.1016\/j.joen.2017.12.011_bib32","doi-asserted-by":"crossref","first-page":"241","DOI":"10.1038\/bdj.2008.152","article-title":"Factors contributing to the separation of endodontic files","volume":"204","author":"Madarati","year":"2008","journal-title":"Br Dent J"},{"key":"10.1016\/j.joen.2017.12.011_bib33","unstructured":"Sterilization dental. Available at: https:\/\/www.isopharm.co.uk\/dental\/sterilisation, Accessed November 16,\u00a02017."},{"key":"10.1016\/j.joen.2017.12.011_bib34","doi-asserted-by":"crossref","first-page":"859","DOI":"10.1016\/j.joen.2008.02.028","article-title":"Multiple autoclave cycles affect the surface of rotary nickel-titanium files: an atomic force microscopy study","volume":"34","author":"Valois","year":"2008","journal-title":"J Endod"},{"key":"10.1016\/j.joen.2017.12.011_bib35","doi-asserted-by":"crossref","first-page":"343","DOI":"10.1016\/S1079-2104(99)70040-5","article-title":"Effect of sterilization on the cutting efficiency of rotary nickel-titanium endodontic files","volume":"88","author":"Rapisarda","year":"1999","journal-title":"Oral Surg Oral Med Oral Pathol Oral Radiol Endod"},{"key":"10.1016\/j.joen.2017.12.011_bib36","doi-asserted-by":"crossref","first-page":"469","DOI":"10.1111\/j.1365-2591.2011.01998.x","article-title":"Physical and mechanical properties of a thermo mechanically treated NiTi wire used in the manufacture of rotary endodontic instruments","volume":"45","author":"Pereira","year":"2012","journal-title":"Int Endod J"},{"key":"10.1016\/j.joen.2017.12.011_bib37","article-title":"Influence of clinical use on physical-structural surface properties and electrochemical potential of NiTi endodontic instruments","author":"Pereira","year":"2017","journal-title":"Int Endod J"},{"key":"10.1016\/j.joen.2017.12.011_bib38","doi-asserted-by":"crossref","first-page":"718","DOI":"10.1111\/iej.12676","article-title":"Effect of irrigation on surface roughness and fatigue resistance of controlled memory wire nickel-titanium instruments","volume":"50","author":"Cai","year":"2017","journal-title":"Int Endod J"}],"container-title":["Journal of Endodontics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S009923991731302X?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S009923991731302X?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2022,8,13]],"date-time":"2022-08-13T20:01:44Z","timestamp":1660420904000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S009923991731302X"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,4]]},"references-count":38,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2018,4]]}},"alternative-id":["S009923991731302X"],"URL":"https:\/\/doi.org\/10.1016\/j.joen.2017.12.011","relation":{},"ISSN":["0099-2399"],"issn-type":[{"value":"0099-2399","type":"print"}],"subject":[],"published":{"date-parts":[[2018,4]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Cyclic Fatigue Resistance of Heat-treated Nickel-titanium Instruments after Immersion in Sodium Hypochlorite and\/or Sterilization","name":"articletitle","label":"Article Title"},{"value":"Journal of Endodontics","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.joen.2017.12.011","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2018 American Association of Endodontists.","name":"copyright","label":"Copyright"}]}}