{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,17]],"date-time":"2026-10-17T14:40:57Z","timestamp":1792248057198,"version":"4.4.0"},"reference-count":17,"publisher":"Elsevier BV","issue":"4","license":[{"start":{"date-parts":[[2018,4,1]],"date-time":"2018-04-01T00:00:00Z","timestamp":1522540800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":["clinicalkey.jp","clinicalkey.com","jendodon.com","clinicalkey.es","clinicalkey.com.au","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Endodontics"],"published-print":{"date-parts":[[2018,4]]},"DOI":"10.1016\/j.joen.2017.12.012","type":"journal-article","created":{"date-parts":[[2018,2,2]],"date-time":"2018-02-02T01:26:12Z","timestamp":1517534772000},"page":"571-575","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":15,"title":["Accuracy of Cone-beam Computed Tomographic Image Interpretation by Endodontists and Endodontic Residents"],"prefix":"10.1016","volume":"44","author":[{"given":"Jeffrey T.","family":"Beacham","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"James R.","family":"Geist","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Qingzhao","family":"Yu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2317-425X","authenticated-orcid":false,"given":"Van T.","family":"Himel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kent A.","family":"Sabey","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.joen.2017.12.012_bib1","doi-asserted-by":"crossref","first-page":"557","DOI":"10.1016\/j.joen.2008.02.022","article-title":"Comparison of periapical radiography and limited cone-beam tomography in posterior maxillary teeth referred for apical surgery","volume":"34","author":"Low","year":"2008","journal-title":"J Endod"},{"key":"10.1016\/j.joen.2017.12.012_bib2","doi-asserted-by":"crossref","first-page":"818","DOI":"10.1111\/j.1365-2591.2007.01299.x","article-title":"The potential applications of cone beam computed tomography in the management of endodontic problems","volume":"40","author":"Patel","year":"2007","journal-title":"Int Endod J"},{"key":"10.1016\/j.joen.2017.12.012_bib3","doi-asserted-by":"crossref","first-page":"508","DOI":"10.1016\/j.oooo.2015.07.033","article-title":"AAE and AAOMR joint position statement: use of cone beam computed tomography in endodontics 2015 update","volume":"120","author":"Fayad","year":"2015","journal-title":"Oral Surg Oral Med Oral Pathol Oral Radiol Endod"},{"key":"10.1016\/j.joen.2017.12.012_bib4","doi-asserted-by":"crossref","first-page":"1895","DOI":"10.1016\/j.joen.2014.05.009","article-title":"The importance of cone-beam computed tomography in the management of endodontic problems: a review of the literature","volume":"40","author":"Venskutonis","year":"2014","journal-title":"J Endod"},{"key":"10.1016\/j.joen.2017.12.012_bib5","doi-asserted-by":"crossref","first-page":"87","DOI":"10.1016\/j.joen.2007.10.016","article-title":"Use of cone-beam computed tomography to identify root canal systems in\u00a0vitro","volume":"34","author":"Matherne","year":"2008","journal-title":"J Endod"},{"key":"10.1016\/j.joen.2017.12.012_bib6","doi-asserted-by":"crossref","first-page":"114","DOI":"10.1016\/j.tripleo.2006.01.001","article-title":"Limited cone-beam CT and intraoral radiography for the diagnosis of periapical pathology","volume":"103","author":"Lofthag","year":"2007","journal-title":"Oral Surg Oral Med Oral Pathol Oral Radiol Endod"},{"key":"10.1016\/j.joen.2017.12.012_bib7","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1111\/iej.12270","article-title":"Cone beam computed tomography in endodontics\u2013a review","volume":"48","author":"Patel","year":"2015","journal-title":"Int Endod J"},{"key":"10.1016\/j.joen.2017.12.012_bib8","doi-asserted-by":"crossref","first-page":"1443","DOI":"10.1002\/j.0022-0337.2012.76.11.tb05405.x","article-title":"Cone beam computed tomography in dental education: a survey of US, UK, and Australian dental schools","volume":"76","author":"Parashar","year":"2012","journal-title":"J Dent Educ"},{"key":"10.1016\/j.joen.2017.12.012_bib9","doi-asserted-by":"crossref","first-page":"522","DOI":"10.1016\/j.joms.2014.10.007","article-title":"Cone-beam computed tomography education and exposure in oral and maxillofacial surgery training programs in the United States","volume":"73","author":"Whitesides","year":"2015","journal-title":"J Oral Maxillofac Surg"},{"key":"10.1016\/j.joen.2017.12.012_bib10","doi-asserted-by":"crossref","first-page":"98","DOI":"10.1002\/j.0022-0337.2011.75.1.tb05028.x","article-title":"An evaluation of cone-beam computed tomography use in postgraduate orthodontic programs in the United States and Canada","volume":"75","author":"Smith","year":"2011","journal-title":"J Dent Educ"},{"key":"10.1016\/j.joen.2017.12.012_bib11","doi-asserted-by":"crossref","first-page":"127","DOI":"10.1016\/j.ajodo.2014.09.019","article-title":"Incidental findings of skull-base abnormalities in cone-beam computed tomography scans with consultation by maxillofacial radiologists","volume":"147","author":"Newaz","year":"2015","journal-title":"Am J Orthod Dentofacial Orthop"},{"key":"10.1016\/j.joen.2017.12.012_bib12","doi-asserted-by":"crossref","first-page":"451","DOI":"10.1016\/j.ajodo.2011.10.025","article-title":"Efficacy of identifying maxillofacial lesions in cone-beam computed tomographs by orthodontists and orthodontic residents with third-party software","volume":"141","author":"Ahmed","year":"2012","journal-title":"Am J Orthod Dentofacial Orthop"},{"key":"10.1016\/j.joen.2017.12.012_bib13","doi-asserted-by":"crossref","first-page":"184","DOI":"10.1016\/j.joen.2016.10.007","article-title":"Cone-beam computed tomography uses in clinical endodontics: observer variability in detecting periapical lesions","volume":"43","author":"Parker","year":"2017","journal-title":"J Endod"},{"key":"10.1016\/j.joen.2017.12.012_bib14","doi-asserted-by":"crossref","first-page":"901","DOI":"10.1016\/j.joen.2017.01.033","article-title":"Incidental findings in small field of view cone-beam computed tomography scans","volume":"43","author":"Oser","year":"2017","journal-title":"J Endod"},{"key":"10.1016\/j.joen.2017.12.012_bib15","doi-asserted-by":"crossref","first-page":"871532","DOI":"10.1155\/2012\/871532","article-title":"Incidental findings on cone beam computed tomography images","volume":"2012","author":"Allareddy","year":"2012","journal-title":"Int J Dent"},{"key":"10.1016\/j.joen.2017.12.012_bib16","doi-asserted-by":"crossref","first-page":"699","DOI":"10.1016\/j.joen.2016.12.021","article-title":"A survey of cone beam tomographic use among endodontic practitioners in the United States","volume":"43","author":"Setzer","year":"2017","journal-title":"J Endod"},{"key":"10.1016\/j.joen.2017.12.012_bib17","series-title":"Clinical Radiology: The Essentials","first-page":"41","article-title":"Overview and principles of diagnostic imaging","author":"Daffner","year":"2014"}],"container-title":["Journal of Endodontics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0099239917313031?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0099239917313031?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2020,10,27]],"date-time":"2020-10-27T00:40:18Z","timestamp":1603759218000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0099239917313031"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,4]]},"references-count":17,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2018,4]]}},"alternative-id":["S0099239917313031"],"URL":"https:\/\/doi.org\/10.1016\/j.joen.2017.12.012","relation":{},"ISSN":["0099-2399"],"issn-type":[{"value":"0099-2399","type":"print"}],"subject":[],"published":{"date-parts":[[2018,4]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Accuracy of Cone-beam Computed Tomographic Image Interpretation by Endodontists and Endodontic Residents","name":"articletitle","label":"Article Title"},{"value":"Journal of Endodontics","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.joen.2017.12.012","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2017 American Association of Endodontists.","name":"copyright","label":"Copyright"}]}}