{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,7]],"date-time":"2026-04-07T05:22:40Z","timestamp":1775539360621,"version":"3.50.1"},"reference-count":36,"publisher":"Elsevier BV","issue":"1","license":[{"start":{"date-parts":[[2026,1,1]],"date-time":"2026-01-01T00:00:00Z","timestamp":1767225600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,1,1]],"date-time":"2026-01-01T00:00:00Z","timestamp":1767225600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2025,9,26]],"date-time":"2025-09-26T00:00:00Z","timestamp":1758844800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.jp","jendodon.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Endodontics"],"published-print":{"date-parts":[[2026,1]]},"DOI":"10.1016\/j.joen.2025.09.012","type":"journal-article","created":{"date-parts":[[2025,10,1]],"date-time":"2025-10-01T16:32:12Z","timestamp":1759336332000},"page":"134-140","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":2,"title":["Influence of Anatomical Parameters on the Accuracy of Electronic Apex Locators in C-shaped Canals: A Novel Micro-CT Analysis Incorporating Feret Diameter"],"prefix":"10.1016","volume":"52","author":[{"ORCID":"https:\/\/orcid.org\/0009-0007-2512-2361","authenticated-orcid":false,"given":"Kuan-Wei","family":"Tung","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hajime","family":"Sasaki","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bruno","family":"Cavalcanti","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Richard","family":"Gardner","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Neville","family":"McDonald","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.joen.2025.09.012_bib1","doi-asserted-by":"crossref","first-page":"384","DOI":"10.1046\/j.1365-2591.1998.00184.x","article-title":"Apical limit of root canal instrumentation and obturation, part 1. Literature review","volume":"31","author":"Ricucci","year":"1998","journal-title":"Int Endod J"},{"key":"10.1016\/j.joen.2025.09.012_bib2","doi-asserted-by":"crossref","first-page":"651","DOI":"10.14219\/jada.archive.1963.0349","article-title":"Factors affecting successful repair after root canal therapy","volume":"67","author":"Seltzer","year":"1963","journal-title":"The J Am Dental Assoc"},{"key":"10.1016\/j.joen.2025.09.012_bib3","doi-asserted-by":"crossref","first-page":"694","DOI":"10.1016\/0030-4220(68)90442-8","article-title":"Biologic aspects of endodontics: Part III. Periapical tissue reactions to root canal instrumentation","volume":"26","author":"Seltzer","year":"1968","journal-title":"Oral Surg Oral Med Oral Pathol"},{"key":"10.1016\/j.joen.2025.09.012_bib4","doi-asserted-by":"crossref","first-page":"498","DOI":"10.1016\/S0099-2399(07)80180-4","article-title":"Factors affecting the long-term results of endodontic treatment","volume":"16","author":"Sj\u00f6gren","year":"1990","journal-title":"J Endod"},{"key":"10.1016\/j.joen.2025.09.012_bib5","doi-asserted-by":"crossref","first-page":"394","DOI":"10.1046\/j.1365-2591.1998.00183.x","article-title":"Apical limit of root canal instrumentation and obturation, part 2. A histological study","volume":"31","author":"Ricucci","year":"1998","journal-title":"Int Endod J"},{"key":"10.1016\/j.joen.2025.09.012_bib6","doi-asserted-by":"crossref","first-page":"825","DOI":"10.1016\/j.tripleo.2011.08.003","article-title":"A prospective cohort study of endodontic treatments of 1,369 root canals: results after 5 years","volume":"112","author":"Ricucci","year":"2011","journal-title":"Oral Surg Oral Med Oral Pathol Oral Radiol Endod"},{"key":"10.1016\/j.joen.2025.09.012_bib7","doi-asserted-by":"crossref","first-page":"113","DOI":"10.5395\/rde.2015.40.2.113","article-title":"Evaluation of electrical impedance ratio measurements in accuracy of electronic apex locators","volume":"40","author":"Kim","year":"2015","journal-title":"Restor Dent Endod"},{"key":"10.1016\/j.joen.2025.09.012_bib8","doi-asserted-by":"crossref","first-page":"173","DOI":"10.1016\/S0099-2399(96)80095-1","article-title":"Comparison of radiographic and electronic working lengths","volume":"22","author":"Pratten","year":"1996","journal-title":"J Endod"},{"key":"10.1016\/j.joen.2025.09.012_bib9","doi-asserted-by":"crossref","first-page":"2003","DOI":"10.1016\/j.joen.2010.08.036","article-title":"Accuracy of three electronic apex locators compared with digital radiography: an ex vivo study","volume":"36","author":"Cianconi","year":"2010","journal-title":"J Endod"},{"key":"10.1016\/j.joen.2025.09.012_bib10","doi-asserted-by":"crossref","first-page":"510","DOI":"10.1111\/j.1365-2591.2011.01855.x","article-title":"Comparison of working length determination with radiographs and four electronic apex locators","volume":"44","author":"Vieyra","year":"2011","journal-title":"Int Endod J"},{"key":"10.1016\/j.joen.2025.09.012_bib11","doi-asserted-by":"crossref","first-page":"1399","DOI":"10.1016\/j.joen.2010.04.006","article-title":"Investigation of apex locators and related morphological factors","volume":"36","author":"Ding","year":"2010","journal-title":"J Endod"},{"key":"10.1016\/j.joen.2025.09.012_bib12","doi-asserted-by":"crossref","first-page":"1263","DOI":"10.1016\/j.joen.2016.04.024","article-title":"The use of micro-computed tomography to determine the accuracy of 2 electronic apex locators and anatomic variations affecting their precision","volume":"42","author":"Piasecki","year":"2016","journal-title":"J Endod"},{"key":"10.1016\/j.joen.2025.09.012_bib13","doi-asserted-by":"crossref","first-page":"1872","DOI":"10.1016\/j.joen.2018.09.001","article-title":"A micro-computed tomographic evaluation of the accuracy of 3 electronic apex locators in curved canals of mandibular molars","volume":"44","author":"Piasecki","year":"2018","journal-title":"J Endod"},{"key":"10.1016\/j.joen.2025.09.012_bib14","doi-asserted-by":"crossref","first-page":"836","DOI":"10.14219\/jada.archive.1979.0402","article-title":"C-shaped canal configurations in mandibular molars","volume":"99","author":"Cooke","year":"1979","journal-title":"J Am Dent Assoc"},{"key":"10.1016\/j.joen.2025.09.012_bib15","doi-asserted-by":"crossref","first-page":"899","DOI":"10.1097\/01.don.0000136207.12204.e4","article-title":"C-shaped Canal System in Mandibular Second Molars: Part I\u2014Anatomical Features","volume":"30","author":"Fan","year":"2004","journal-title":"J Endod"},{"key":"10.1016\/j.joen.2025.09.012_bib16","doi-asserted-by":"crossref","first-page":"1012","DOI":"10.1111\/iej.12256","article-title":"Aetiology, incidence and morphology of the C-shaped root canal system and its impact on clinical endodontics","volume":"47","author":"Kato","year":"2014","journal-title":"Int Endod J"},{"key":"10.1016\/j.joen.2025.09.012_bib17","doi-asserted-by":"crossref","first-page":"223","DOI":"10.1111\/iej.12814","article-title":"Evaluation of the accuracy of nine electronic apex locators by using micro-CT","volume":"51","author":"Connert","year":"2018","journal-title":"Int Endod J"},{"key":"10.1016\/j.joen.2025.09.012_bib18","doi-asserted-by":"crossref","first-page":"671","DOI":"10.4067\/S0717-95022014000200048","article-title":"Morphology of the physiological apical foramen in maxillary and mandibular first molars","volume":"32","author":"Abarca","year":"2014","journal-title":"Int J Morphol"},{"key":"10.1016\/j.joen.2025.09.012_bib19","doi-asserted-by":"crossref","first-page":"513","DOI":"10.61872\/sdj-2017-06-281","article-title":"Micro-CT assessment of internal morphology and root canal configuration of non C-shaped mandibular second molars","volume":"127","author":"Wolf","year":"2017","journal-title":"Swiss dental J"},{"key":"10.1016\/j.joen.2025.09.012_bib20","doi-asserted-by":"crossref","first-page":"625","DOI":"10.1016\/S0099-2399(99)80323-9","article-title":"Effect of preflaring on root ZX apex locators","volume":"25","author":"Ibarrola","year":"1999","journal-title":"J Endod"},{"key":"10.1016\/j.joen.2025.09.012_bib21","doi-asserted-by":"crossref","first-page":"1300","DOI":"10.1016\/j.joen.2009.05.030","article-title":"Influence of preflaring on the accuracy of length determination with four electronic apex locators","volume":"35","author":"de Camargo","year":"2009","journal-title":"J Endod"},{"key":"10.1016\/j.joen.2025.09.012_bib22","doi-asserted-by":"crossref","first-page":"49","DOI":"10.1016\/j.joen.2010.08.048","article-title":"Comparison of the reliability of \u201c0.5\u201d and \u201cAPEX\u201d mark measurements in two frequency-based electronic apex locators","volume":"37","author":"Jung","year":"2011","journal-title":"J Endod"},{"key":"10.1016\/j.joen.2025.09.012_bib23","doi-asserted-by":"crossref","first-page":"940","DOI":"10.1046\/j.1365-2591.2002.00576.x","article-title":"A simple model to demonstrate the electronic apex locator","volume":"35","author":"Tinaz","year":"2002","journal-title":"Int Endod J"},{"key":"10.1016\/j.joen.2025.09.012_bib24","doi-asserted-by":"crossref","first-page":"706","DOI":"10.1111\/iej.12670","article-title":"Validity of longitudinal sections for determining the apical constriction","volume":"50","author":"Schell","year":"2017","journal-title":"Int Endod J"},{"key":"10.1016\/j.joen.2025.09.012_bib25","doi-asserted-by":"crossref","first-page":"544","DOI":"10.14219\/jada.archive.1955.0099","article-title":"Microscopic investigation of root apexes","volume":"50","author":"Kuttler","year":"1955","journal-title":"J Am Dent Assoc"},{"key":"10.1016\/j.joen.2025.09.012_bib26","doi-asserted-by":"crossref","first-page":"192","DOI":"10.1111\/j.1365-2591.1984.tb00404.x","article-title":"The position and topography of the apical canal constriction and apical foramen","volume":"17","author":"Dummer","year":"1984","journal-title":"Int Endod J"},{"key":"10.1016\/j.joen.2025.09.012_bib27","doi-asserted-by":"crossref","first-page":"1095","DOI":"10.1016\/j.joen.2013.12.002","article-title":"Apical constriction: location and dimensions in molars-a micro-computed tomography study","volume":"40","author":"ElAyouti","year":"2014","journal-title":"J Endod"},{"key":"10.1016\/j.joen.2025.09.012_bib28","first-page":"60","article-title":"Evaluation of conventional radiography and an electronic apex locator in determining the working length in C-shaped canals","volume":"12","author":"Jafarzadeh","year":"2017","journal-title":"Iranian Endod J"},{"key":"10.1016\/j.joen.2025.09.012_bib29","article-title":"Comparative evaluation of accuracy of different apex locators: Propex IQ, Raypex 6, Root ZX, and Apex ID with CBCT and periapical radiograph\u2014in vitro study","volume":"2021","author":"Mahmoud","year":"2021","journal-title":"Int Endod J"},{"key":"10.1016\/j.joen.2025.09.012_bib30","doi-asserted-by":"crossref","first-page":"281","DOI":"10.1111\/iej.13738","article-title":"A critical analysis of research methods and experimental models to study working length determination and the performance of apex locators\u2013A narrative review with recommendations for the future","volume":"55","author":"ElAyouti","year":"2022","journal-title":"Int Endod J"},{"key":"10.1016\/j.joen.2025.09.012_bib31","doi-asserted-by":"crossref","first-page":"239","DOI":"10.1111\/j.1365-2591.2007.01193.x","article-title":"Morphometric study of the apical anatomy of C-shaped root canal systems in mandibular second molars","volume":"40","author":"Cheung","year":"2007","journal-title":"Int Endod J"},{"key":"10.1016\/j.joen.2025.09.012_bib32","doi-asserted-by":"crossref","first-page":"5","DOI":"10.1016\/S0099-2399(07)80022-7","article-title":"An evaluation of the apex locator Endocater","volume":"16","author":"McDonald","year":"1990","journal-title":"J Endod"},{"key":"10.1016\/j.joen.2025.09.012_bib33","doi-asserted-by":"crossref","first-page":"595","DOI":"10.1111\/j.1365-2591.2006.01131.x","article-title":"The fundamental operating principles of electronic root canal length measurement devices","volume":"39","author":"Nekoofar","year":"2006","journal-title":"Int Endod J"},{"key":"10.1016\/j.joen.2025.09.012_bib34","doi-asserted-by":"crossref","DOI":"10.1149\/1.2844440","article-title":"Impedance characteristics of mimic human tooth root canal and its equivalent circuit model","volume":"155","author":"Huang","year":"2008","journal-title":"J The Electrochem Soc"},{"key":"10.1016\/j.joen.2025.09.012_bib35","doi-asserted-by":"crossref","first-page":"1663","DOI":"10.1016\/j.joen.2017.03.039","article-title":"Determination of the accuracy of 5 electronic apex locators in the function of different employment protocols","volume":"43","author":"Oliveira","year":"2017","journal-title":"J Endod"},{"key":"10.1016\/j.joen.2025.09.012_bib36","doi-asserted-by":"crossref","first-page":"904","DOI":"10.1111\/iej.12078","article-title":"Evaluation of the Joypex 5 and Root ZX II: an in vivo and ex vivo study","volume":"46","author":"Soares","year":"2013","journal-title":"Int Endod J"}],"container-title":["Journal of Endodontics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0099239925005886?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0099239925005886?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,1,28]],"date-time":"2026-01-28T01:29:41Z","timestamp":1769563781000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0099239925005886"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,1]]},"references-count":36,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2026,1]]}},"alternative-id":["S0099239925005886"],"URL":"https:\/\/doi.org\/10.1016\/j.joen.2025.09.012","relation":{},"ISSN":["0099-2399"],"issn-type":[{"value":"0099-2399","type":"print"}],"subject":[],"published":{"date-parts":[[2026,1]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Influence of Anatomical Parameters on the Accuracy of Electronic Apex Locators in C-shaped Canals: A Novel Micro-CT Analysis Incorporating Feret Diameter","name":"articletitle","label":"Article Title"},{"value":"Journal of Endodontics","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.joen.2025.09.012","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2025 The Authors. Published by Elsevier Inc. on behalf of American Association of Endodontists.","name":"copyright","label":"Copyright"}]}}