{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,3]],"date-time":"2026-08-03T23:41:25Z","timestamp":1785800485108,"version":"3.56.0"},"reference-count":23,"publisher":"Elsevier BV","issue":"3","license":[{"start":{"date-parts":[[2014,3,1]],"date-time":"2014-03-01T00:00:00Z","timestamp":1393632000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2014,3,1]],"date-time":"2014-03-01T00:00:00Z","timestamp":1393632000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","joms.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Oral and Maxillofacial Surgery"],"published-print":{"date-parts":[[2014,3]]},"DOI":"10.1016\/j.joms.2013.08.030","type":"journal-article","created":{"date-parts":[[2013,11,21]],"date-time":"2013-11-21T12:06:47Z","timestamp":1385035607000},"page":"611-618","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":33,"title":["Magnetic Resonance Imaging: An Accurate, Radiation-Free, Alternative to Computed Tomography for the Primary Imaging and Three-Dimensional Reconstruction of the Bony Orbit"],"prefix":"10.1016","volume":"72","author":[{"given":"Beat","family":"Schmutz","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Benjamin","family":"Rahmel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zeb","family":"McNamara","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alan","family":"Coulthard","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael","family":"Schuetz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anthony","family":"Lynham","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.joms.2013.08.030_bib1","doi-asserted-by":"crossref","first-page":"604","DOI":"10.1097\/00006534-199803000-00006","article-title":"Orbital reconstruction with individually copy milled ceramic implants","volume":"101","author":"Hoffmann","year":"1998","journal-title":"Plast Reconstr Surg"},{"key":"10.1016\/j.joms.2013.08.030_bib2","doi-asserted-by":"crossref","first-page":"168","DOI":"10.1007\/s10140-003-0282-7","article-title":"CT of orbital trauma","volume":"10","author":"Lee","year":"2004","journal-title":"Emerg Radiol"},{"key":"10.1016\/j.joms.2013.08.030_bib3","doi-asserted-by":"crossref","first-page":"1729","DOI":"10.1148\/rg.286085523","article-title":"Imaging of orbital trauma","volume":"28","author":"Kubal","year":"2008","journal-title":"Radiographics"},{"key":"10.1016\/j.joms.2013.08.030_bib4","doi-asserted-by":"crossref","first-page":"442","DOI":"10.1016\/j.tripleo.2006.02.031","article-title":"Individual preformed titanium meshes for orbital fractures","volume":"102","author":"Metzger","year":"2006","journal-title":"Oral Surg Oral Med Oral Pathol Oral Radiol Endod"},{"key":"10.1016\/j.joms.2013.08.030_bib5","first-page":"2006","article-title":"Anatomical 3-dimensional pre-bent titanium implant for orbital floor fractures","volume":"113","author":"Metzger","year":"1863","journal-title":"Ophthalmology"},{"key":"10.1016\/j.joms.2013.08.030_bib6","first-page":"667","article-title":"CAD\/CAM-prefabricated titanium implants for large skull defects\u2014Clinical experience with 166 patients from 1994 to 2000","volume":"1268","author":"Wehm\u00f6ller","year":"2004","journal-title":"Comput Assist Radiol Surg"},{"key":"10.1016\/j.joms.2013.08.030_bib7","doi-asserted-by":"crossref","first-page":"384","DOI":"10.1016\/S0901-5027(00)80059-4","article-title":"Synthesis of CAD\/CAM, robotics and biomaterial implant fabrication: Single-step reconstruction in computer aided frontotemporal bone resection","volume":"29","author":"Weihe","year":"2000","journal-title":"Int J Oral Maxillofac Surg"},{"key":"10.1016\/j.joms.2013.08.030_bib8","first-page":"1417","article-title":"Computer-assisted secondary reconstruction of unilateral posttraumatic orbital deformity","volume":"110","author":"Gellrich","year":"2002","journal-title":"Plast Reconstr Surg"},{"key":"10.1016\/j.joms.2013.08.030_bib9","doi-asserted-by":"crossref","first-page":"955","DOI":"10.1016\/j.injury.2004.06.005","article-title":"Navigation-aided reconstruction of medial orbital wall and floor contour in cranio-maxillofacial reconstruction","volume":"35","author":"Schmelzeisen","year":"2004","journal-title":"Injury"},{"key":"10.1016\/j.joms.2013.08.030_bib10","doi-asserted-by":"crossref","first-page":"990","DOI":"10.1016\/j.ijom.2006.06.018","article-title":"Individually preformed titanium mesh implants for a true-to-original repair of orbital fractures","volume":"35","author":"Sch\u00f6n","year":"2006","journal-title":"Int J Oral Maxillofac Surg"},{"key":"10.1016\/j.joms.2013.08.030_bib11","series-title":"Recent Results in Cancer Research","doi-asserted-by":"crossref","first-page":"231","DOI":"10.1007\/978-3-642-84892-6_20","article-title":"Eye sequelae following external irradiation","author":"Hempel","year":"1993"},{"key":"10.1016\/j.joms.2013.08.030_bib12","doi-asserted-by":"crossref","first-page":"815","DOI":"10.1016\/0360-3016(93)90310-R","article-title":"Radiation dose to the lens and cataract formation","volume":"25","author":"Henk","year":"1993","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.joms.2013.08.030_bib13","first-page":"181","article-title":"Lens exclusion in computed tomography scans of the brain\u2014The local practice","volume":"4","author":"Lai","year":"2001","journal-title":"J Hong Kong Coll Radiol"},{"key":"10.1016\/j.joms.2013.08.030_bib14","doi-asserted-by":"crossref","first-page":"1250","DOI":"10.1007\/s00330-005-2660-x","article-title":"Evaluation of reconstructed orbital wall fractures: High-resolution MRI using a microscopy surface coil versus 16-slice MSCT","volume":"15","author":"Wiener","year":"2005","journal-title":"Eur Radiol"},{"key":"10.1016\/j.joms.2013.08.030_bib15","doi-asserted-by":"crossref","first-page":"492","DOI":"10.1016\/j.joms.2004.12.004","article-title":"A novel high-resolution magnetic resonance imaging microscopy coil as an alternative to the multislice computed tomography in postoperative imaging of orbital fractures and computer-based volume measurement","volume":"63","author":"Kolk","year":"2005","journal-title":"J Oral Maxillofac Surg"},{"key":"10.1016\/j.joms.2013.08.030_bib16","doi-asserted-by":"crossref","first-page":"348","DOI":"10.1016\/j.joms.2008.04.003","article-title":"High resolution magnetic resonance imaging with an orbital coil as an alternative to computed tomography scan as the primary imaging modality of pediatric orbital fractures","volume":"67","author":"Kolk","year":"2009","journal-title":"J Oral Maxillofac Surg"},{"key":"10.1016\/j.joms.2013.08.030_bib17","doi-asserted-by":"crossref","first-page":"601","DOI":"10.1259\/bjr\/96872829","article-title":"The technology of MRI\u2014The next 10 years?","volume":"81","author":"Blamire","year":"2008","journal-title":"Br J Radiol"},{"key":"10.1016\/j.joms.2013.08.030_bib18","series-title":"Medical Solutions","first-page":"94","article-title":"MR imaging at 7T","author":"Grimm","year":"2006"},{"key":"10.1016\/j.joms.2013.08.030_bib19","doi-asserted-by":"crossref","first-page":"S188","DOI":"10.1016\/S0021-9290(08)70188-X","article-title":"Using MRI for the imaging of long bones: First experiences","volume":"41","author":"Schmutz","year":"2008","journal-title":"J Biomech"},{"key":"10.1016\/j.joms.2013.08.030_bib20","doi-asserted-by":"crossref","first-page":"357","DOI":"10.1016\/j.medengphy.2011.07.027","article-title":"Quantification of the accuracy of MRI generated 3D models of long bones compared to CT generated 3D models","volume":"34","author":"Rathnayaka","year":"2012","journal-title":"Med Eng Physics"},{"key":"10.1016\/j.joms.2013.08.030_bib21","series-title":"Proceedings of the 6th Australasian Biomechanics Conference","first-page":"93","article-title":"The effect of CT slice\u00a0spacing on the geometry of 3D models","author":"Schmutz","year":"2007"},{"key":"10.1016\/j.joms.2013.08.030_bib22","series-title":"Proceedings of the 12th International Congress and Exhibition CAR '98 Computer Assisted Radiology and Surgery","first-page":"137","article-title":"Interactive segmentation of 3D medical images with subvoxel accuracy","author":"Stalling","year":"1998"},{"key":"10.1016\/j.joms.2013.08.030_bib23","doi-asserted-by":"crossref","first-page":"383","DOI":"10.1097\/IOP.0b013e318185a72c","article-title":"Computer-aided volume measurement of posttraumatic orbits reconstructed with AO titanium mesh plates: Accuracy and reliability","volume":"24","author":"Scolozzi","year":"2008","journal-title":"Ophthal Plast Reconstr Surg"}],"container-title":["Journal of Oral and Maxillofacial Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0278239113011397?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0278239113011397?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,3]],"date-time":"2025-10-03T16:43:19Z","timestamp":1759509799000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0278239113011397"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,3]]},"references-count":23,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2014,3]]}},"alternative-id":["S0278239113011397"],"URL":"https:\/\/doi.org\/10.1016\/j.joms.2013.08.030","relation":{},"ISSN":["0278-2391"],"issn-type":[{"value":"0278-2391","type":"print"}],"subject":[],"published":{"date-parts":[[2014,3]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Magnetic Resonance Imaging: An Accurate, Radiation-Free, Alternative to Computed Tomography for the Primary Imaging and Three-Dimensional Reconstruction of the Bony Orbit","name":"articletitle","label":"Article Title"},{"value":"Journal of Oral and Maxillofacial Surgery","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.joms.2013.08.030","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2014 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}