{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,9]],"date-time":"2026-10-09T21:52:14Z","timestamp":1791582734366,"version":"4.3.4"},"reference-count":26,"publisher":"Scientific Scholar","license":[{"start":{"date-parts":[[2024,5,1]],"date-time":"2024-05-01T00:00:00Z","timestamp":1714521600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2024,5,1]],"date-time":"2024-05-01T00:00:00Z","timestamp":1714521600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.fr","clinicalkey.jp","clinicalkey.es","clinicalkey.com.au","clinicalkey.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Orthopaedics"],"published-print":{"date-parts":[[2024,5]]},"DOI":"10.1016\/j.jor.2024.01.011","type":"journal-article","created":{"date-parts":[[2024,2,6]],"date-time":"2024-02-06T02:38:36Z","timestamp":1707187116000},"page":"122-129","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":12,"special_numbering":"C","title":["A systematic review of the biomechanical properties of suture materials used in orthopaedics"],"prefix":"10.25259","volume":"51","author":[{"given":"Andres R.","family":"Perez","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6879-4877","authenticated-orcid":false,"given":"Carlo","family":"Coladonato","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0009-8137-0495","authenticated-orcid":false,"given":"Rahul","family":"Muchintala","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nicholas","family":"Christopher","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"John","family":"Matthews","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fotios P.","family":"Tjoumakaris","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kevin B.","family":"Freedman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"10894","reference":[{"issue":"3","key":"10.1016\/j.jor.2024.01.011_bib1","doi-asserted-by":"crossref","first-page":"387","DOI":"10.1007\/s00402-008-0639-1","article-title":"Double transosseous pull out suture technique for transection of posterior horn of medial meniscus","volume":"129","author":"Ahn","year":"2009","journal-title":"Arch Orthop Trauma Surg"},{"issue":"12","key":"10.1016\/j.jor.2024.01.011_bib2","article-title":"A pull out suture for transection of the posterior horn of the medial meniscus: using a posterior trans-septal portal","volume":"15","author":"Jh","year":"2007","journal-title":"Knee Surg Sports Traumatol Arthrosc Off J ESSKA"},{"issue":"3","key":"10.1016\/j.jor.2024.01.011_bib3","doi-asserted-by":"crossref","first-page":"387","DOI":"10.1007\/s00402-011-1429-8","article-title":"Posterior root tear fixation of the lateral meniscus combined with arthroscopic ACL double-bundle reconstruction: technical note of a transosseous fixation using the tibial PL tunnel","volume":"132","author":"Forkel","year":"2012","journal-title":"Arch Orthop Trauma Surg"},{"issue":"5","key":"10.1016\/j.jor.2024.01.011_bib4","doi-asserted-by":"crossref","first-page":"621","DOI":"10.1007\/s00402-013-1716-7","article-title":"Biomechanical consequences of a posterior root tear of the lateral meniscus: stabilizing effect of the meniscofemoral ligament","volume":"133","author":"Forkel","year":"2013","journal-title":"Arch Orthop Trauma Surg"},{"issue":"Suppl 2","key":"10.1016\/j.jor.2024.01.011_bib5","doi-asserted-by":"crossref","first-page":"257","DOI":"10.2106\/JBJS.I.00500","article-title":"Biomechanical consequences of a tear of the posterior root of the medial meniscus. Surgical technique","volume":"91","author":"Harner","year":"2009","journal-title":"J Bone Joint Surg Am"},{"issue":"5","key":"10.1016\/j.jor.2024.01.011_bib6","doi-asserted-by":"crossref","first-page":"1148","DOI":"10.1177\/0363546511435622","article-title":"Prognostic factors of arthroscopic pull-out repair for a posterior root tear of the medial meniscus","volume":"40","author":"Moon","year":"2012","journal-title":"Am J Sports Med"},{"issue":"3","key":"10.1016\/j.jor.2024.01.011_bib7","doi-asserted-by":"crossref","first-page":"358","DOI":"10.1016\/j.arthro.2009.08.013","article-title":"The effect of a nonanatomic repair of the meniscal horn attachment on meniscal tension: a biomechanical study","volume":"26","author":"St\u00e4rke","year":"2010","journal-title":"Arthrosc J Arthrosc Relat Surg Off Publ Arthrosc Assoc N Am Int Arthrosc Assoc"},{"issue":"6","key":"10.1016\/j.jor.2024.01.011_bib8","doi-asserted-by":"crossref","first-page":"832","DOI":"10.1002\/jor.22806","article-title":"Mechanisms of tendon injury and repair","volume":"33","author":"Thomopoulos","year":"2015","journal-title":"J Orthop Res Off Publ Orthop Res Soc"},{"issue":"7","key":"10.1016\/j.jor.2024.01.011_bib9","doi-asserted-by":"crossref","first-page":"975","DOI":"10.2106\/00004623-199907000-00010","article-title":"The effect of gap formation at the repair site on the strength and excursion of intrasynovial flexor tendons. An experimental study on the early stages of tendon-healing in dogs","volume":"81","author":"Gelberman","year":"1999","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.jor.2024.01.011_bib10","doi-asserted-by":"crossref","first-page":"n71","DOI":"10.1136\/bmj.n71","article-title":"The PRISMA 2020 statement: an updated guideline for reporting systematic reviews","volume":"372","author":"Page","year":"2021","journal-title":"BMJ"},{"issue":"5","key":"10.1016\/j.jor.2024.01.011_bib11","doi-asserted-by":"crossref","first-page":"907","DOI":"10.1177\/0363546508314793","article-title":"Influence of suture material on the biomechanical behavior of suture-tendon specimens: a controlled study in bovine rotator cuff","volume":"36","author":"Bisson","year":"2008","journal-title":"Am J Sports Med"},{"issue":"11","key":"10.1016\/j.jor.2024.01.011_bib12","doi-asserted-by":"crossref","first-page":"1463","DOI":"10.1016\/j.arthro.2010.04.075","article-title":"A biomechanical comparison of the pullout strength of No. 2 FiberWire suture and 2-mm FiberWire tape in bovine rotator cuff tendons","volume":"26","author":"Bisson","year":"2010","journal-title":"Arthrosc J Arthrosc Relat Surg Off Publ Arthrosc Assoc N Am Int Arthrosc Assoc"},{"key":"10.1016\/j.jor.2024.01.011_bib13","doi-asserted-by":"crossref","first-page":"42","DOI":"10.1186\/s43019-020-00053-4","article-title":"The influence of suture materials on the biomechanical behavior of suture-meniscal specimens: a comparative study in a porcine model","volume":"32","author":"Matthews","year":"2020","journal-title":"Knee Surg Relat Res"},{"issue":"2","key":"10.1016\/j.jor.2024.01.011_bib14","doi-asserted-by":"crossref","first-page":"266","DOI":"10.1111\/j.1532-950X.2011.00887.x","article-title":"Mechanical testing of orthopedic suture material used for extra-articular stabilization of canine cruciate ligament-deficient stifles","volume":"41","author":"Rose","year":"2012","journal-title":"Vet Surg VS"},{"issue":"1","key":"10.1016\/j.jor.2024.01.011_bib15","doi-asserted-by":"crossref","first-page":"132","DOI":"10.1007\/s00167-013-2656-z","article-title":"Biomechanical evaluation of different suture materials for arthroscopic transtibial pull-out repair of posterior meniscus root tears","volume":"23","author":"Feucht","year":"2015","journal-title":"Knee Surg Sports Traumatol Arthrosc Off J ESSKA"},{"issue":"3","key":"10.1016\/j.jor.2024.01.011_bib16","doi-asserted-by":"crossref","first-page":"708","DOI":"10.1016\/j.arthro.2019.08.048","article-title":"A biomechanical comparison of different suture materials used for arthroscopic shoulder procedures - PubMed","volume":"36","author":"Taha","year":"2020","journal-title":"Arthrosc J Arthrosc Relat Surg Off Publ Arthrosc Assoc N Am Int Arthrosc Assoc"},{"issue":"9","key":"10.1016\/j.jor.2024.01.011_bib17","doi-asserted-by":"crossref","DOI":"10.1177\/2325967119873274","article-title":"Different suture materials for arthroscopic transtibial pull-out repair of medial meniscal posterior root tears: a human biomechanical study","volume":"7","author":"Nakama","year":"2019","journal-title":"Orthop J Sports Med"},{"issue":"11","key":"10.1016\/j.jor.2024.01.011_bib18","doi-asserted-by":"crossref","first-page":"1406","DOI":"10.1016\/j.arthro.2014.05.030","article-title":"Viscoelastic properties of common suture material used for rotator cuff repair and arthroscopic procedures","volume":"30","author":"Hurwit","year":"2014","journal-title":"Arthrosc J Arthrosc Relat Surg Off Publ Arthrosc Assoc N Am Int Arthrosc Assoc"},{"key":"10.1016\/j.jor.2024.01.011_bib19","doi-asserted-by":"crossref","first-page":"72","DOI":"10.1186\/s13018-014-0072-9","article-title":"Suture material for flexor tendon repair: 3-0 V-Loc versus 3-0 Stratafix in a biomechanical comparison ex vivo","volume":"9","author":"Jordan","year":"2014","journal-title":"J Orthop Surg"},{"issue":"3","key":"10.1016\/j.jor.2024.01.011_bib20","first-page":"247","article-title":"Mechanical study of the properties of sutures used in orthopedics surgeries","volume":"54","author":"Gomide","year":"2019","journal-title":"Rev Bras Ortop"},{"issue":"4","key":"10.1016\/j.jor.2024.01.011_bib21","doi-asserted-by":"crossref","DOI":"10.1177\/2325967117701212","article-title":"Tape versus suture in arthroscopic rotator cuff repair: biomechanical analysis and assessment of failure rates at 6 months","volume":"5","author":"Liu","year":"2017","journal-title":"Orthop J Sports Med"},{"key":"10.1016\/j.jor.2024.01.011_bib22","first-page":"84","article-title":"Material properties of common suture materials in orthopaedic surgery","volume":"30","author":"Najibi","year":"2010","journal-title":"Iowa Orthop J"},{"issue":"2","key":"10.1016\/j.jor.2024.01.011_bib23","doi-asserted-by":"crossref","first-page":"192","DOI":"10.1016\/j.arthro.2008.09.010","article-title":"Cyclic load and failure behavior of arthroscopic knots and high strength sutures","volume":"25","author":"Barber","year":"2009","journal-title":"Arthrosc J Arthrosc Relat Surg Off Publ Arthrosc Assoc N Am Int Arthrosc Assoc"},{"issue":"5","key":"10.1016\/j.jor.2024.01.011_bib24","doi-asserted-by":"crossref","first-page":"649","DOI":"10.1007\/s00402-011-1452-9","article-title":"Comparison of three suture techniques and three suture materials on gap formation and failure load in ruptured tendons: a human cadaveric study","volume":"132","author":"Petri","year":"2012","journal-title":"Arch Orthop Trauma Surg"},{"issue":"11","key":"10.1016\/j.jor.2024.01.011_bib25","doi-asserted-by":"crossref","first-page":"1146","DOI":"10.1016\/j.arthro.2006.06.013","article-title":"Mechanical and handling properties of braided polyblend polyethylene sutures in comparison to braided polyester and monofilament polydioxanone sutures","volume":"22","author":"W\u00fcst","year":"2006","journal-title":"Arthrosc J Arthrosc Relat Surg Off Publ Arthrosc Assoc N Am Int Arthrosc Assoc"},{"issue":"6","key":"10.1016\/j.jor.2024.01.011_bib26","first-page":"614","article-title":"Biomechanical differences resulting from the combination of suture materials and repair techniques","volume":"11","author":"Yamagami","year":"2006","journal-title":"J Orthop Sci Off J Jpn Orthop Assoc"}],"container-title":["Journal of Orthopaedics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0972978X24000205?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0972978X24000205?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,9,11]],"date-time":"2026-09-11T14:06:29Z","timestamp":1789135589000},"score":1,"resource":{"primary":{"URL":"https:\/\/jortho.org\/a-systematic-review-of-the-biomechanical-properties-of-suture-materials-used-in-orthopaedics\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,5]]},"references-count":26,"alternative-id":["S0972978X24000205"],"URL":"https:\/\/doi.org\/10.1016\/j.jor.2024.01.011","relation":{},"ISSN":["0972-978X"],"issn-type":[{"value":"0972-978X","type":"print"}],"subject":[],"published":{"date-parts":[[2024,5]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"A systematic review of the biomechanical properties of suture materials used in orthopaedics","name":"articletitle","label":"Article Title"},{"value":"Journal of Orthopaedics","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jor.2024.01.011","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Published by Elsevier B.V. on behalf of Professor P K Surendran Memorial Education Foundation.","name":"copyright","label":"Copyright"}]}}