{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,11]],"date-time":"2026-09-11T15:07:47Z","timestamp":1789139267888,"version":"build-2803163510"},"reference-count":29,"publisher":"Scientific Scholar","license":[{"start":{"date-parts":[[2026,1,1]],"date-time":"2026-01-01T00:00:00Z","timestamp":1767225600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,1,1]],"date-time":"2026-01-01T00:00:00Z","timestamp":1767225600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Orthopaedics"],"published-print":{"date-parts":[[2026,1]]},"DOI":"10.1016\/j.jor.2025.08.051","type":"journal-article","created":{"date-parts":[[2025,8,25]],"date-time":"2025-08-25T23:24:09Z","timestamp":1756164249000},"page":"237-240","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"special_numbering":"C","title":["Common adjustments made in robotic total knee arthroplasty to achieve functional alignment and minimize soft tissue releases"],"prefix":"10.25259","volume":"71","author":[{"given":"Dalton L.","family":"Braathen","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ian M.","family":"Clapp","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0006-2819-3539","authenticated-orcid":false,"given":"Anish","family":"Singh","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Brenna E.","family":"Blackburn","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christopher L.","family":"Peters","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9238-2274","authenticated-orcid":false,"given":"Michael J.","family":"Archibeck","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"10894","reference":[{"issue":"12","key":"10.1016\/j.jor.2025.08.051_bib1","doi-asserted-by":"crossref","first-page":"3474","DOI":"10.1016\/j.arth.2020.06.072","article-title":"Robotic surgery in total Joint Arthroplasty: a survey of the AAHKS membership to understand the utilization, motivations, and perceptions of total joint surgeons","volume":"35","author":"Sherman","year":"2020","journal-title":"J Arthroplast"},{"key":"10.1016\/j.jor.2025.08.051_bib2","doi-asserted-by":"crossref","first-page":"13","DOI":"10.1016\/j.artd.2022.02.015","article-title":"Patient interest in robotic total joint arthroplasty is exponential: a 10-Year google trends analysis","volume":"15","author":"Brinkman","year":"2022","journal-title":"Arthroplast Today"},{"issue":"1","key":"10.1016\/j.jor.2025.08.051_bib3","doi-asserted-by":"crossref","first-page":"137","DOI":"10.1007\/s11701-024-01888-9","article-title":"Is 80% satisfaction still the expectation in modern TKA mechanically aligned with robot assist? We think not","volume":"18","author":"Selvanathan","year":"2024","journal-title":"J Robotic Surge"},{"issue":"12","key":"10.1016\/j.jor.2025.08.051_bib4","doi-asserted-by":"crossref","first-page":"3854","DOI":"10.1016\/j.arth.2017.07.021","article-title":"Patient dissatisfaction following total knee arthroplasty: a systematic review of the literature","volume":"32","author":"Gunaratne","year":"2017","journal-title":"J Arthroplast"},{"issue":"3","key":"10.1016\/j.jor.2025.08.051_bib5","doi-asserted-by":"crossref","first-page":"1072","DOI":"10.1007\/s00167-022-07227-5","article-title":"Functional alignment with robotic-arm assisted total knee arthroplasty demonstrated better patient-reported outcomes than mechanical alignment with manual total knee arthroplasty","volume":"31","author":"Choi","year":"2023","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"issue":"2","key":"10.1016\/j.jor.2025.08.051_bib6","doi-asserted-by":"crossref","first-page":"488","DOI":"10.1007\/s00167-020-06165-4","article-title":"Higher satisfaction after total knee arthroplasty using restricted inverse kinematic alignment compared to adjusted mechanical alignment","volume":"30","author":"Winnock de Grave","year":"2022","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"issue":"7","key":"10.1016\/j.jor.2025.08.051_bib7","doi-asserted-by":"crossref","first-page":"2133","DOI":"10.1016\/j.arth.2017.02.028","article-title":"The impact of mechanical and restricted kinematic alignment on knee anatomy in total knee arthroplasty","volume":"32","author":"Almaawi","year":"2017","journal-title":"J Arthroplast"},{"key":"10.1016\/j.jor.2025.08.051_bib8","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1051\/sicotj\/2022010","article-title":"Functional alignment philosophy in total knee arthroplasty - rationale and technique for the varus morphotype using a CT based robotic platform and individualized planning","volume":"8","author":"Shatrov","year":"2022","journal-title":"Sicot J"},{"issue":"3","key":"10.1016\/j.jor.2025.08.051_bib9","doi-asserted-by":"crossref","first-page":"185","DOI":"10.1097\/BTO.0000000000000567","article-title":"Individualized functional knee alignment in total knee arthroplasty: a robotic-assisted technique","volume":"37","author":"Clark","year":"2022","journal-title":"Tech Orthop"},{"issue":"4","key":"10.1016\/j.jor.2025.08.051_bib10","doi-asserted-by":"crossref","first-page":"1420","DOI":"10.1007\/s00167-022-07156-3","article-title":"Functional alignment achieves a more balanced total knee arthroplasty than either mechanical alignment or kinematic alignment prior to soft tissue releases","volume":"31","author":"Clark","year":"2023","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"issue":"9","key":"10.1016\/j.jor.2025.08.051_bib11","doi-asserted-by":"crossref","first-page":"2991","DOI":"10.1007\/s00167-022-07073-5","article-title":"Kinematic alignment fails to achieve balancing in 50% of varus knees and resects more bone compared to functional alignment","volume":"30","author":"Shatrov","year":"2022","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"issue":"11","key":"10.1016\/j.jor.2025.08.051_bib12","doi-asserted-by":"crossref","first-page":"3426","DOI":"10.1007\/s11999-014-3865-6","article-title":"Collateral ligament laxity in knees: what is normal?","volume":"472","author":"Deep","year":"2014","journal-title":"Clin Orthop Relat Res"},{"issue":"8","key":"10.1016\/j.jor.2025.08.051_bib13","doi-asserted-by":"crossref","first-page":"2696","DOI":"10.1007\/s00167-021-06522-x","article-title":"Correction to: Robotic-arm assisted total knee arthroplasty is associated with improved accuracy and patient reported outcomes: a systematic review and meta-analysis","volume":"30","author":"Zhang","year":"2022","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"issue":"10","key":"10.1016\/j.jor.2025.08.051_bib14","doi-asserted-by":"crossref","first-page":"1064","DOI":"10.1055\/s-0040-1701440","article-title":"Robot-assisted versus conventional total and unicompartmental knee arthroplasty: a meta-analysis of radiological and functional outcomes","volume":"34","author":"Chin","year":"2021","journal-title":"J Knee Surg"},{"issue":"10","key":"10.1016\/j.jor.2025.08.051_bib15","doi-asserted-by":"crossref","first-page":"611","DOI":"10.1302\/2058-5241.4.190022","article-title":"Robotic technology in total knee arthroplasty: a systematic review","volume":"4","author":"Kayani","year":"2019","journal-title":"EFORT Open Rev"},{"issue":"4","key":"10.1016\/j.jor.2025.08.051_bib16","doi-asserted-by":"crossref","first-page":"1741","DOI":"10.1007\/s00402-023-05195-0","article-title":"Functional alignment in robotic-assisted total knee arthroplasty: a systematic review","volume":"144","author":"Migliorini","year":"2024","journal-title":"Arch Orthop Trauma Surg"},{"issue":"2","key":"10.1016\/j.jor.2025.08.051_bib17","doi-asserted-by":"crossref","first-page":"365","DOI":"10.1007\/s00167-021-06844-w","article-title":"A safe transition to a more personalized alignment in total knee arthroplasty: the importance of a \"safe zone\" concept","volume":"30","author":"von Eisenhart-Rothe","year":"2022","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"issue":"5","key":"10.1016\/j.jor.2025.08.051_bib18","doi-asserted-by":"crossref","first-page":"1221","DOI":"10.1007\/s00264-022-05681-x","article-title":"How does the use of quantified gap-balancing affect component positioning and limb alignment in robotic total knee arthroplasty using functional alignment philosophy? A comparison of two robotic platforms","volume":"47","author":"Murphy","year":"2023","journal-title":"Int Orthop"},{"key":"10.1016\/j.jor.2025.08.051_bib19","doi-asserted-by":"crossref","first-page":"1141","DOI":"10.1007\/s00402-019-03221-8","article-title":"Posterior condylar resections in total knee arthroplasty: current standard instruments do not restore femoral condylar anatomy","volume":"139","author":"Wuertele","year":"2019","journal-title":"Arch Orthop Trauma Surg"},{"issue":"6","key":"10.1016\/j.jor.2025.08.051_bib20","doi-asserted-by":"crossref","first-page":"316","DOI":"10.3928\/01477447-20190906-05","article-title":"The effect of femoral cutting jig design on restoration of femoral offset in posterior-referenced total knee arthroplasty","volume":"42","author":"Coyle","year":"2019","journal-title":"Orthopedics"},{"issue":"4","key":"10.1016\/j.jor.2025.08.051_bib21","doi-asserted-by":"crossref","first-page":"725","DOI":"10.1016\/j.knee.2015.11.018","article-title":"Anatomical landmarks of the distal femoral condyles are not always parallel to the tibial bone cut surface in flexion during total knee arthroplasty","volume":"23","author":"Itokazu","year":"2016","journal-title":"Knee"},{"key":"10.1016\/j.jor.2025.08.051_bib22","doi-asserted-by":"crossref","first-page":"379","DOI":"10.1007\/s00264-013-2097-9","article-title":"The relationship between the survival of total knee arthroplasty and postoperative coronal, sagittal and rotational alignment of knee prosthesis","volume":"38","author":"Kim","year":"2014","journal-title":"Int Orthop"},{"issue":"7, Supplement","key":"10.1016\/j.jor.2025.08.051_bib23","doi-asserted-by":"crossref","first-page":"S380","DOI":"10.1016\/j.arth.2020.12.028","article-title":"Three degrees external to the posterior condylar axis has little relevance in femoral component rotation: a computed tomography-based total knee arthroplasty simulation study","volume":"36","author":"Chalmers","year":"2021","journal-title":"J Arthroplast"},{"issue":"1","key":"10.1016\/j.jor.2025.08.051_bib24","first-page":"4","article-title":"Rotational alignment of the femoral component in total knee arthroplasty","volume":"4","author":"Castelli","year":"2016","journal-title":"Ann Transl Med"},{"issue":"12","key":"10.1016\/j.jor.2025.08.051_bib25","doi-asserted-by":"crossref","first-page":"3810","DOI":"10.1007\/s00167-020-05864-2","article-title":"Malrotation of the fixed\u2010bearing posterior stabilized total knee prosthesis causes a postoperative rotational mismatch between the femur and tibia","volume":"28","author":"Ueyama","year":"2020","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"issue":"11","key":"10.1016\/j.jor.2025.08.051_bib26","doi-asserted-by":"crossref","first-page":"1121","DOI":"10.1055\/s-0039-1692486","article-title":"Femoral component malrotation produces quadriceps weakness and impaired ambulatory function following total knee arthroplasty: results of a forward-dynamic computer model","volume":"33","author":"Nettrour","year":"2020","journal-title":"J Knee Surg"},{"key":"10.1016\/j.jor.2025.08.051_bib27","doi-asserted-by":"crossref","first-page":"1767","DOI":"10.1007\/s00167-017-4778-1","article-title":"Internal femoral component malrotation in TKA significantly alters tibiofemoral kinematics","volume":"26","author":"Heyse","year":"2018","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"issue":"7","key":"10.1016\/j.jor.2025.08.051_bib28","doi-asserted-by":"crossref","first-page":"1382","DOI":"10.1016\/j.arth.2019.02.056","article-title":"Knee arthroplasty component malrotation does not affect function or quality of life in the short to medium term","volume":"34","author":"Babazadeh","year":"2019","journal-title":"J Arthroplast"},{"key":"10.1016\/j.jor.2025.08.051_bib29","doi-asserted-by":"crossref","first-page":"1456","DOI":"10.1007\/s00167-018-4981-8","article-title":"No correlation between rotation of femoral components in the transverse plane and clinical outcome after total knee arthroplasty","volume":"27","author":"Becker","year":"2019","journal-title":"Knee Surg Sports Traumatol Arthrosc"}],"container-title":["Journal of Orthopaedics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0972978X25003666?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0972978X25003666?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,9,11]],"date-time":"2026-09-11T14:09:21Z","timestamp":1789135761000},"score":1,"resource":{"primary":{"URL":"https:\/\/jortho.org\/common-adjustments-made-in-robotic-total-knee-arthroplasty-to-achieve-functional-alignment-and-minimize-soft-tissue-releases\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,1]]},"references-count":29,"alternative-id":["S0972978X25003666"],"URL":"https:\/\/doi.org\/10.1016\/j.jor.2025.08.051","relation":{},"ISSN":["0972-978X"],"issn-type":[{"value":"0972-978X","type":"print"}],"subject":[],"published":{"date-parts":[[2026,1]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Common adjustments made in robotic total knee arthroplasty to achieve functional alignment and minimize soft tissue releases","name":"articletitle","label":"Article Title"},{"value":"Journal of Orthopaedics","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jor.2025.08.051","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2025 Professor P K Surendran Memorial Education Foundation. Published by Elsevier B.V. All rights are reserved, including those for text and data mining, AI training, and similar technologies.","name":"copyright","label":"Copyright"}]}}