{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,11]],"date-time":"2026-09-11T15:07:04Z","timestamp":1789139224177,"version":"build-2803163510"},"reference-count":21,"publisher":"Scientific Scholar","license":[{"start":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T00:00:00Z","timestamp":1777593600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T00:00:00Z","timestamp":1777593600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Orthopaedics"],"published-print":{"date-parts":[[2026,5]]},"DOI":"10.1016\/j.jor.2026.02.010","type":"journal-article","created":{"date-parts":[[2026,2,3]],"date-time":"2026-02-03T07:47:06Z","timestamp":1770104826000},"page":"262-267","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"special_numbering":"C","title":["Accuracy and safety of acetabular cup placement in total hip arthroplasty using mixed-reality navigation: A prospective trial"],"prefix":"10.25259","volume":"75","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-7132-4067","authenticated-orcid":false,"suffix":"2nd","given":"Joseph P.","family":"Costello","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Samantha G.","family":"Mosle","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0008-3731-7235","authenticated-orcid":false,"given":"Hannah","family":"Mosher","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3850-6384","authenticated-orcid":false,"given":"Aneesh V.","family":"Samineni","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8786-6082","authenticated-orcid":false,"given":"Gilberto O.","family":"Lobaton","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8905-1853","authenticated-orcid":false,"given":"Michele R.","family":"D'Apuzzo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Victor H.","family":"Hernandez","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"10894","reference":[{"issue":"20","key":"10.1016\/j.jor.2026.02.010_bib1","doi-asserted-by":"crossref","first-page":"1900","DOI":"10.2106\/JBJS.20.00950","article-title":"The use of computer navigation in total hip arthroplasty is associated with a reduced rate of revision for dislocation: a study of 6,912 navigated THA procedures from the Australian orthopaedic association national joint replacement registry","volume":"103","author":"Agarwal","year":"2021","journal-title":"J Bone Joint Surg Am"},{"issue":"3","key":"10.1016\/j.jor.2026.02.010_bib2","doi-asserted-by":"crossref","first-page":"250","DOI":"10.2106\/JBJS.18.00108","article-title":"Computer-assisted navigation is associated with reductions in the rates of dislocation and acetabular component revision following primary total hip arthroplasty","volume":"101","author":"Bohl","year":"2019","journal-title":"J Bone Joint Surg Am"},{"issue":"3","key":"10.1016\/j.jor.2026.02.010_bib3","article-title":"Reduced risk of revision with computer-guided versus non-computer-guided THA: an analysis of manufacturer-specific data from the national joint registry of England, Wales, Northern Ireland and the Isle of Man","volume":"6","author":"Davis","year":"2021","journal-title":"JB JS Open Access"},{"issue":"3","key":"10.1016\/j.jor.2026.02.010_bib4","doi-asserted-by":"crossref","first-page":"843","DOI":"10.1016\/j.arth.2016.08.024","article-title":"Effect of acetabular component positioning on functional outcomes in primary total hip arthroplasty","volume":"32","author":"Goyal","year":"2017","journal-title":"J Arthroplast"},{"issue":"11","key":"10.1016\/j.jor.2026.02.010_bib5","doi-asserted-by":"crossref","first-page":"1959","DOI":"10.1016\/j.arth.2015.05.022","article-title":"Comparison of cup alignment, jump distance, and complications in consecutive series of anterior approach and posterior approach total hip arthroplasty","volume":"30","author":"Hamilton","year":"2015","journal-title":"J Arthroplast"},{"issue":"3","key":"10.1016\/j.jor.2026.02.010_bib6","doi-asserted-by":"crossref","first-page":"453","DOI":"10.1007\/s00264-019-04461-4","article-title":"Direct anterior approach in lateral position achieves superior cup orientation in total hip arthroplasty: a radiological comparative study of two consecutive series","volume":"44","author":"Hu","year":"2020","journal-title":"Int Orthop"},{"issue":"1","key":"10.1016\/j.jor.2026.02.010_bib7","doi-asserted-by":"crossref","DOI":"10.1371\/journal.pone.0191401","article-title":"Radiographic cup position following posterior and lateral approach to total hip arthroplasty. An explorative randomized controlled trial","volume":"13","author":"Kruse","year":"2018","journal-title":"PLoS One"},{"issue":"5","key":"10.1016\/j.jor.2026.02.010_bib8","doi-asserted-by":"crossref","first-page":"380","DOI":"10.1097\/HP.0000000000001679","article-title":"Intraoperative fluoroscopy radiation using OEC 9900 elite C-arm: risk and method for decreasing exposure","volume":"124","author":"Keenen","year":"2023","journal-title":"Health Phys"},{"issue":"6","key":"10.1016\/j.jor.2026.02.010_bib9","doi-asserted-by":"crossref","first-page":"1636","DOI":"10.1016\/j.arth.2020.01.025","article-title":"Augmented reality for acetabular component placement in direct anterior total hip arthroplasty","volume":"35","author":"Alexander","year":"2020","journal-title":"J Arthroplast"},{"issue":"9","key":"10.1016\/j.jor.2026.02.010_bib10","doi-asserted-by":"crossref","first-page":"721","DOI":"10.2106\/JBJS.N.00839","article-title":"Fluoroscopic radiation exposure: are we protecting ourselves adequately?","volume":"97","author":"Hoffler","year":"2015","journal-title":"J Bone Joint Surg Am"},{"issue":"5","key":"10.1016\/j.jor.2026.02.010_bib11","article-title":"Increased prevalence of breast and all-cause cancer in female orthopaedic surgeons","volume":"6","author":"Chou","year":"2022","journal-title":"J Am Acad Orthop Surg Glob Res Rev"},{"issue":"5","key":"10.1016\/j.jor.2026.02.010_bib12","doi-asserted-by":"crossref","first-page":"914","DOI":"10.1111\/os.12537","article-title":"Mixed reality combined with three-dimensional printing technology in total hip arthroplasty: an updated review with a preliminary case presentation","volume":"11","author":"Lei","year":"2019","journal-title":"Orthop Surg"},{"key":"10.1016\/j.jor.2026.02.010_bib13","doi-asserted-by":"crossref","DOI":"10.3389\/fsurg.2022.804029","article-title":"Mixed reality technology in total knee arthroplasty: an updated review with a preliminary case report","volume":"9","author":"Su","year":"2022","journal-title":"Front Surg"},{"issue":"3","key":"10.1016\/j.jor.2026.02.010_bib14","doi-asserted-by":"crossref","first-page":"304","DOI":"10.1177\/1553350618771413","article-title":"Mixed reality technology-assisted orthopedics surgery navigation","volume":"25","author":"Wu","year":"2018","journal-title":"Surg Innov"},{"issue":"1","key":"10.1016\/j.jor.2026.02.010_bib15","doi-asserted-by":"crossref","first-page":"121","DOI":"10.1186\/s13018-023-03604-z","article-title":"The effectiveness of virtual reality, augmented reality, and mixed reality training in total hip arthroplasty: a systematic review and meta-analysis","volume":"18","author":"Su","year":"2023","journal-title":"J Orthop Surg Res"},{"issue":"4","key":"10.1016\/j.jor.2026.02.010_bib16","doi-asserted-by":"crossref","first-page":"706","DOI":"10.1177\/0018720820904229","article-title":"The effects of virtual reality, augmented reality, and mixed reality as training enhancement methods: a meta-analysis","volume":"63","author":"Kaplan","year":"2021","journal-title":"Hum Factors"},{"issue":"2","key":"10.1016\/j.jor.2026.02.010_bib17","doi-asserted-by":"crossref","first-page":"217","DOI":"10.2106\/00004623-197860020-00014","article-title":"Dislocations after total hip-replacement arthroplasties","volume":"60","author":"Lewinnek","year":"1978","journal-title":"J Bone Joint Surg Am"},{"issue":"11","key":"10.1016\/j.jor.2026.02.010_bib18","doi-asserted-by":"crossref","first-page":"815","DOI":"10.3928\/01477447-20090922-08","article-title":"Reproducibility and accuracy of templating uncemented THA with digital radiographic and digital TraumaCad templating software","volume":"32","author":"Kumar","year":"2009","journal-title":"Orthopedics"},{"issue":"12","key":"10.1016\/j.jor.2026.02.010_bib19","doi-asserted-by":"crossref","first-page":"1429","DOI":"10.1007\/s00402-010-1046-y","article-title":"Preoperative planning of total hip replacement using the TraumaCad\u2122 system","volume":"130","author":"Steinberg","year":"2010","journal-title":"Arch Orthop Trauma Surg"},{"issue":"5","key":"10.1016\/j.jor.2026.02.010_bib20","doi-asserted-by":"crossref","first-page":"2739","DOI":"10.1007\/s00402-022-04520-3","article-title":"Use of a novel imageless navigation system reduced fluoroscopy exposure and improved acetabular positioning in anterior approach total hip arthroplasty: a case-control study","volume":"143","author":"Ong","year":"2023","journal-title":"Arch Orthop Trauma Surg"},{"issue":"3","key":"10.1016\/j.jor.2026.02.010_bib21","doi-asserted-by":"crossref","first-page":"488","DOI":"10.1016\/j.arth.2021.11.004","article-title":"Augmented Reality- vs accelerometer-based portable navigation system to improve the accuracy of acetabular cup placement during total hip arthroplasty in the lateral decubitus position","volume":"37","author":"Tsukada","year":"2022","journal-title":"J Arthroplast"}],"container-title":["Journal of Orthopaedics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0972978X26000401?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0972978X26000401?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,9,11]],"date-time":"2026-09-11T14:08:20Z","timestamp":1789135700000},"score":1,"resource":{"primary":{"URL":"https:\/\/jortho.org\/accuracy-and-safety-of-acetabular-cup-placement-in-total-hip-arthroplasty-using-mixed-reality-navigation-a-prospective-trial\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,5]]},"references-count":21,"alternative-id":["S0972978X26000401"],"URL":"https:\/\/doi.org\/10.1016\/j.jor.2026.02.010","relation":{},"ISSN":["0972-978X"],"issn-type":[{"value":"0972-978X","type":"print"}],"subject":[],"published":{"date-parts":[[2026,5]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Accuracy and safety of acetabular cup placement in total hip arthroplasty using mixed-reality navigation: A prospective trial","name":"articletitle","label":"Article Title"},{"value":"Journal of Orthopaedics","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jor.2026.02.010","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2026 Published by Elsevier B.V. on behalf of Professor P K Surendran Memorial Education Foundation.","name":"copyright","label":"Copyright"}]}}