{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,14]],"date-time":"2026-10-14T13:23:50Z","timestamp":1791984230613,"version":"4.4.0"},"reference-count":25,"publisher":"Elsevier BV","issue":"1","license":[{"start":{"date-parts":[[2023,2,1]],"date-time":"2023-02-01T00:00:00Z","timestamp":1675209600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2023,2,1]],"date-time":"2023-02-01T00:00:00Z","timestamp":1675209600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2022,9,20]],"date-time":"2022-09-20T00:00:00Z","timestamp":1663632000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["clinicalkey.fr","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Stomatology, Oral and Maxillofacial Surgery"],"published-print":{"date-parts":[[2023,2]]},"DOI":"10.1016\/j.jormas.2022.09.011","type":"journal-article","created":{"date-parts":[[2022,9,21]],"date-time":"2022-09-21T14:30:26Z","timestamp":1663770626000},"page":"101290","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":37,"special_numbering":"S","title":["Finite element analysis of the biomechanical effects of titanium and Cfr-peek additively manufactured subperiosteal jaw implant (AMSJI) on maxilla"],"prefix":"10.1016","volume":"124","author":[{"given":"Nur","family":"Alt\u0131parmak","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Serhat","family":"Polat","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7901-4178","authenticated-orcid":false,"given":"Selen","family":"Onat","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"issue":"1","key":"10.1016\/j.jormas.2022.09.011_bib0001","doi-asserted-by":"crossref","first-page":"5","DOI":"10.1563\/1548-1336-35.1.5","article-title":"The use of laser technology (Er;Cr:YSGG) and stereolithography to aid in the placement of a subperiosteal implant: case study","volume":"35","author":"Kusek","year":"2009","journal-title":"J Oral Implantol"},{"issue":"3","key":"10.1016\/j.jormas.2022.09.011_bib0002","doi-asserted-by":"crossref","first-page":"111","DOI":"10.1563\/1548-1336(2003)029<0111:AOHCSI>2.3.CO;2","article-title":"Analysis of HA-coated subperiosteal implants","volume":"29","author":"Minichetti","year":"2003","journal-title":"J Oral Implantol"},{"issue":"7","key":"10.1016\/j.jormas.2022.09.011_bib0003","doi-asserted-by":"crossref","first-page":"938","DOI":"10.1016\/j.ijom.2017.02.002","article-title":"Additively manufactured sub-periosteal jaw implants","volume":"46","author":"Mommaerts","year":"2017","journal-title":"Int J Oral Maxillofac Surg"},{"issue":"3","key":"10.1016\/j.jormas.2022.09.011_bib0004","doi-asserted-by":"crossref","first-page":"410","DOI":"10.1016\/0022-3913(85)90562-1","article-title":"Titanium: the mystery metal of implant dentistry. Dental materials aspects","volume":"54","author":"Parr","year":"1985","journal-title":"J Prosthet Dent"},{"issue":"2","key":"10.1016\/j.jormas.2022.09.011_bib0005","first-page":"106","article-title":"Dental implants: materials and design considerations","volume":"6","author":"Smith","year":"1993","journal-title":"J Prosthodont"},{"issue":"3","key":"10.1016\/j.jormas.2022.09.011_bib0006","doi-asserted-by":"crossref","first-page":"932","DOI":"10.3390\/ma8030932","article-title":"A critical review of dental implant materials with an emphasis on titanium versus zirconia","volume":"8","author":"Osman","year":"2015","journal-title":"Materials (Basel)"},{"issue":"3","key":"10.1016\/j.jormas.2022.09.011_bib0007","doi-asserted-by":"crossref","first-page":"46","DOI":"10.1007\/s11837-008-0031-1","article-title":"Biomedical applications of titanium and its alloys","volume":"60","author":"Elias","year":"2008","journal-title":"Jom"},{"issue":"4Suppl","key":"10.1016\/j.jormas.2022.09.011_bib0008","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1016\/S0020-1383(00)80019-4","article-title":"Nonresorbable polymers in bone surgery","volume":"31","author":"Eschbach","year":"2000","journal-title":"Injury"},{"issue":"1","key":"10.1016\/j.jormas.2022.09.011_bib0009","doi-asserted-by":"crossref","first-page":"12","DOI":"10.1016\/j.jpor.2015.10.001","article-title":"Applications of polyetheretherketone (PEEK) in oral implantology and prosthodontics","volume":"60","author":"Najeeb","year":"2016","journal-title":"J Prosthodont Res"},{"issue":"9","key":"10.1016\/j.jormas.2022.09.011_bib0010","doi-asserted-by":"crossref","first-page":"1976","DOI":"10.1016\/0032-3861(92)90503-O","article-title":"Synthesis, characterization and study of the thermal properties of new polyarylene ethers","volume":"33","author":"Staniland","year":"1992","journal-title":"Polymer (Guildf)"},{"issue":"3","key":"10.1016\/j.jormas.2022.09.011_bib0011","doi-asserted-by":"crossref","first-page":"251","DOI":"10.1002\/jbm.820070317","article-title":"Stress distribution in bone arising from loading on endosteal dental implants","volume":"7","author":"Tesk","year":"1973","journal-title":"J Biomed Mater Res"},{"issue":"1","key":"10.1016\/j.jormas.2022.09.011_bib0012","doi-asserted-by":"crossref","first-page":"38","DOI":"10.1016\/j.prosdent.2004.10.001","article-title":"Three-dimensional finite-element analysis of functional stresses in different bone locations produced by implants placed in the maxillary posterior region of the sinus floor","volume":"93","author":"Koca","year":"2005","journal-title":"J Prosthet Dent"},{"issue":"6Suppl","key":"10.1016\/j.jormas.2022.09.011_bib0013","doi-asserted-by":"crossref","first-page":"S35","DOI":"10.1016\/S0022-3913(07)60006-7","article-title":"Tilting of splinted implants for improved prosthodontic support: a two-dimensional finite element analysis","volume":"97","author":"Zampelis","year":"2007","journal-title":"J Prosthet Dent"},{"issue":"Suppl1","key":"10.1016\/j.jormas.2022.09.011_bib0014","doi-asserted-by":"crossref","first-page":"49","DOI":"10.1007\/s12306-018-0562-8","article-title":"Comparison of CFR-PEEK and conventional titanium locking plates for proximal humeral fractures: a retrospective controlled study of patient outcomes","volume":"102","author":"Padolino","year":"2018","journal-title":"Musculoskelet Surg"},{"issue":"4","key":"10.1016\/j.jormas.2022.09.011_bib0015","doi-asserted-by":"crossref","first-page":"e468","DOI":"10.3928\/01477447-20130327-24","article-title":"Relative osteopenia after femoral implant removal in children and adolescents","volume":"36","author":"Patman","year":"2013","journal-title":"Orthopedics"},{"issue":"6","key":"10.1016\/j.jormas.2022.09.011_bib0016","doi-asserted-by":"crossref","first-page":"772","DOI":"10.1007\/s00776-003-0718-7","article-title":"Bone mineral density after removal of rigid plates from forearm fractures: preliminary report","volume":"8","author":"Kettunen","year":"2003","journal-title":"J Orthop Sci"},{"issue":"6","key":"10.1016\/j.jormas.2022.09.011_bib0017","doi-asserted-by":"crossref","first-page":"914","DOI":"10.1302\/0301-620X.75B6.8245081","article-title":"Bone density after rigid plate fixation of tibial fractures. A dual-energy X-ray absorptiometry study","volume":"75","author":"Janes","year":"1993","journal-title":"J Bone Joint Surg Br"},{"issue":"1","key":"10.1016\/j.jormas.2022.09.011_bib0018","doi-asserted-by":"crossref","first-page":"107","DOI":"10.1302\/0301-620X.58B1.1270486","article-title":"Protection from stress in bone and its effects. Experiments with stainless steel and plastic plates in dogs","volume":"58","author":"Tonino","year":"1976","journal-title":"J Bone Joint Surg Br"},{"issue":"5","key":"10.1016\/j.jormas.2022.09.011_bib0019","doi-asserted-by":"crossref","first-page":"1124","DOI":"10.1016\/j.jbiomech.2007.12.013","article-title":"Selections of the cylinder implant neck taper and implant end fillet for optimal biomechanical properties: a three-dimensional finite element analysis","volume":"41","author":"Kong","year":"2008","journal-title":"J Biomech"},{"issue":"10","key":"10.1016\/j.jormas.2022.09.011_bib0020","doi-asserted-by":"crossref","first-page":"2102","DOI":"10.1016\/j.jbiomech.2015.03.006","article-title":"The effect of implant number and position on the stress behavior of mandibular implant retained overdentures: a three-dimensional finite element analysis","volume":"48","author":"Topkaya","year":"2015","journal-title":"J Biomech"},{"issue":"6","key":"10.1016\/j.jormas.2022.09.011_bib0021","doi-asserted-by":"crossref","first-page":"491","DOI":"10.1016\/0003-9969(93)90185-O","article-title":"A three-dimensional, finite-element analysis of bone around dental implants in an edentulous human mandible","volume":"38","author":"Meijer","year":"1993","journal-title":"Arch Oral Biol"},{"issue":"1","key":"10.1016\/j.jormas.2022.09.011_bib0022","doi-asserted-by":"crossref","first-page":"53","DOI":"10.1016\/1350-4533(94)90011-6","article-title":"Mechanical simulation of the human mandible with and without an endosseous implant","volume":"16","author":"Chen","year":"1994","journal-title":"Med Eng Phys"},{"issue":"4","key":"10.1016\/j.jormas.2022.09.011_bib0023","first-page":"315","article-title":"Comparative three-dimensional analysis of two finite-element endosseous implant designs","volume":"20","author":"Lozada","year":"1994","journal-title":"J Oral Implantol"},{"issue":"Suppl6","key":"10.1016\/j.jormas.2022.09.011_bib0024","doi-asserted-by":"crossref","first-page":"95","DOI":"10.1111\/j.1600-0501.2012.02550.x","article-title":"Occlusal overload and bone\/implant loss","volume":"23","author":"Naert","year":"2012","journal-title":"Clin Oral Implants Res"},{"issue":"2","key":"10.1016\/j.jormas.2022.09.011_bib0025","first-page":"165","article-title":"Evaluation of threshold stress for bone resorption around screws based on in vivo strain measurement of miniplate","volume":"1","author":"Sugiura","year":"2000","journal-title":"J Musculoskelet Neuronal Interact"}],"container-title":["Journal of Stomatology, Oral and Maxillofacial Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2468785522002798?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2468785522002798?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,11,11]],"date-time":"2025-11-11T10:13:19Z","timestamp":1762855999000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2468785522002798"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,2]]},"references-count":25,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2023,2]]}},"alternative-id":["S2468785522002798"],"URL":"https:\/\/doi.org\/10.1016\/j.jormas.2022.09.011","relation":{},"ISSN":["2468-7855"],"issn-type":[{"value":"2468-7855","type":"print"}],"subject":[],"published":{"date-parts":[[2023,2]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Finite element analysis of the biomechanical effects of titanium and Cfr-peek additively manufactured subperiosteal jaw implant (AMSJI) on maxilla","name":"articletitle","label":"Article Title"},{"value":"Journal of Stomatology, Oral and Maxillofacial Surgery","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jormas.2022.09.011","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2022 The Author(s). Published by Elsevier Masson SAS.","name":"copyright","label":"Copyright"}],"article-number":"101290"}}