{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,15]],"date-time":"2026-03-15T18:06:38Z","timestamp":1773597998562,"version":"3.50.1"},"reference-count":26,"publisher":"Elsevier BV","issue":"2","license":[{"start":{"date-parts":[[2021,3,1]],"date-time":"2021-03-01T00:00:00Z","timestamp":1614556800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2021,3,1]],"date-time":"2021-03-01T00:00:00Z","timestamp":1614556800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"funder":[{"DOI":"10.13039\/100009026","name":"Smith and Nephew","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100009026","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Orthopaedic Science"],"published-print":{"date-parts":[[2021,3]]},"DOI":"10.1016\/j.jos.2020.02.017","type":"journal-article","created":{"date-parts":[[2020,3,27]],"date-time":"2020-03-27T16:40:14Z","timestamp":1585327214000},"page":"207-212","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":4,"title":["Comparison between single and double suture passing techniques in the suture bridge rotator cuff repair with a 2-mm tape: A simulation study using a three-dimensional finite element method"],"prefix":"10.1016","volume":"26","author":[{"given":"Hirotaka","family":"Sano","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tatsuro","family":"Komatsuda","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takashi","family":"Inawashiro","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Daizo","family":"Sasaki","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Moriyuki","family":"Noguchi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Taichi","family":"Irie","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hiroo","family":"Abe","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hiroshi","family":"Ozawa","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"suffix":"Jr.","given":"A. Toshimitsu","family":"Yokobori","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"issue":"1","key":"10.1016\/j.jos.2020.02.017_bib1","doi-asserted-by":"crossref","first-page":"10","DOI":"10.1016\/j.arthro.2012.06.020","article-title":"Arthroscopic suture-bridge repair for small to medium size supraspinatus tear: healing rate and retear pattern","volume":"29","author":"Neyton","year":"2013","journal-title":"Arthroscopy"},{"issue":"12","key":"10.1016\/j.jos.2020.02.017_bib2","doi-asserted-by":"crossref","first-page":"1360 e1","DOI":"10.1016\/j.arthro.2006.07.017","article-title":"\u201cTransosseous-equivalent\u201d rotator cuff repair technique","volume":"22","author":"Park","year":"2006","journal-title":"Arthroscopy"},{"issue":"4","key":"10.1016\/j.jos.2020.02.017_bib3","doi-asserted-by":"crossref","first-page":"461","DOI":"10.1016\/j.jse.2006.09.010","article-title":"Part I: footprint contact characteristics for a transosseous-equivalent rotator cuff repair technique compared with a double-row repair technique","volume":"16","author":"Park","year":"2007","journal-title":"J\u00a0Shoulder Elb Surg"},{"issue":"4","key":"10.1016\/j.jos.2020.02.017_bib4","doi-asserted-by":"crossref","first-page":"469","DOI":"10.1016\/j.jse.2006.09.011","article-title":"Part II: biomechanical assessment for a footprint-restoring transosseous-equivalent rotator cuff repair technique compared with a double-row repair technique","volume":"16","author":"Park","year":"2007","journal-title":"J\u00a0Shoulder Elb Surg"},{"issue":"8","key":"10.1016\/j.jos.2020.02.017_bib5","doi-asserted-by":"crossref","first-page":"1254","DOI":"10.1002\/jor.22363","article-title":"Biomechanical comparison of single-row, double-row, and transosseous-equivalent repair techniques after healing in an animal rotator cuff tear model","volume":"31","author":"Quigley","year":"2013","journal-title":"J\u00a0Orthop Res"},{"issue":"6","key":"10.1016\/j.jos.2020.02.017_bib6","doi-asserted-by":"crossref","first-page":"1578","DOI":"10.1007\/s11999-009-0990-8","article-title":"Does an arthroscopic suture bridge technique maintain repair integrity?: a serial evaluation by ultrasonography","volume":"468","author":"Park","year":"2010","journal-title":"Clin Orthop Relat Res"},{"issue":"2","key":"10.1016\/j.jos.2020.02.017_bib7","doi-asserted-by":"crossref","first-page":"280","DOI":"10.1016\/j.arthro.2012.09.008","article-title":"Clinical and ultrasonographic outcomes of arthroscopic suture bridge repair for massive rotator cuff tear","volume":"29","author":"Park","year":"2013","journal-title":"Arthroscopy"},{"issue":"10","key":"10.1016\/j.jos.2020.02.017_bib8","doi-asserted-by":"crossref","first-page":"2108","DOI":"10.1177\/0363546510397171","article-title":"Arthroscopic rotator cuff repair using a suture bridge technique: is the repair integrity actually maintained?","volume":"39","author":"Cho","year":"2011","journal-title":"Am J Sports Med"},{"issue":"4","key":"10.1016\/j.jos.2020.02.017_bib9","doi-asserted-by":"crossref","first-page":"786","DOI":"10.1177\/0363546511434546","article-title":"Clinical and radiographic outcomes after arthroscopic repair of massive rotator cuff tears using a suture bridge technique: assessment of repair integrity on magnetic resonance imaging","volume":"40","author":"Kim","year":"2012","journal-title":"Am J Sports Med"},{"issue":"5","key":"10.1016\/j.jos.2020.02.017_bib10","doi-asserted-by":"crossref","first-page":"983","DOI":"10.1177\/0363546509359063","article-title":"Arthroscopic supraspinatus tendon repair with suture-bridging technique: functional outcome and magnetic resonance imaging","volume":"38","author":"Voigt","year":"2010","journal-title":"Am J Sports Med"},{"issue":"11","key":"10.1016\/j.jos.2020.02.017_bib11","doi-asserted-by":"crossref","first-page":"2274","DOI":"10.1016\/j.arthro.2015.06.004","article-title":"Retear rates after arthroscopic single-row, double-row, and suture bridge rotator cuff repair at a minimum of 1 year of imaging follow-up: a systematic review","volume":"31","author":"Hein","year":"2015","journal-title":"Arthroscopy"},{"issue":"4","key":"10.1016\/j.jos.2020.02.017_bib12","doi-asserted-by":"crossref","first-page":"664","DOI":"10.1177\/0363546509350081","article-title":"Retear patterns after arthroscopic rotator cuff repair: single-row versus suture bridge technique","volume":"38","author":"Cho","year":"2010","journal-title":"Am J Sports Med"},{"issue":"8","key":"10.1016\/j.jos.2020.02.017_bib13","doi-asserted-by":"crossref","first-page":"1473","DOI":"10.1016\/j.arthro.2017.03.021","article-title":"Knotless transosseous-equivalent rotator cuff repair improves biomechanical self-reinforcement without diminishing footprint contact compared with medial knotted repair","volume":"33","author":"Park","year":"2017","journal-title":"Arthroscopy"},{"issue":"9","key":"10.1016\/j.jos.2020.02.017_bib14","doi-asserted-by":"crossref","first-page":"1582","DOI":"10.1007\/s00167-011-1436-x","article-title":"Biomechanical evaluation of four different transosseous-equivalent\/suture bridge rotator cuff repairs","volume":"19","author":"Maguire","year":"2011","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"issue":"3","key":"10.1016\/j.jos.2020.02.017_bib15","first-page":"267","article-title":"Tight medial knot tying may increase retearing risk after transosseous equivalent repair of rotator cuff tendon","volume":"28","author":"Sano","year":"2017","journal-title":"Bio Med Mater Eng"},{"issue":"4","key":"10.1016\/j.jos.2020.02.017_bib16","doi-asserted-by":"crossref","first-page":"542","DOI":"10.1177\/0363546506296310","article-title":"Stress distribution in the supraspinatus tendon after tendon repair: suture anchors versus transosseous suture fixation","volume":"35","author":"Sano","year":"2007","journal-title":"Am J Sports Med"},{"issue":"4","key":"10.1016\/j.jos.2020.02.017_bib17","doi-asserted-by":"crossref","first-page":"557","DOI":"10.1016\/j.jse.2015.09.002","article-title":"A\u00a03D finite element model for geometrical and mechanical comparison of different supraspinatus repair techniques","volume":"25","author":"Mantovani","year":"2016","journal-title":"J\u00a0Shoulder Elb Surg"},{"key":"10.1016\/j.jos.2020.02.017_bib18","first-page":"84","article-title":"Material properties of common suture materials in orthopaedic surgery","volume":"30","author":"Najibi","year":"2010","journal-title":"Iowa Orthop J"},{"issue":"1","key":"10.1016\/j.jos.2020.02.017_bib19","doi-asserted-by":"crossref","first-page":"S53","DOI":"10.1016\/j.clinbiomech.2007.12.011","article-title":"Comparative evaluation on three-dimensional finite element models of the temporomandibular joint","volume":"23","author":"Liu","year":"2008","journal-title":"Clin Biomech"},{"issue":"10","key":"10.1016\/j.jos.2020.02.017_bib20","doi-asserted-by":"crossref","first-page":"2262","DOI":"10.1177\/0363546513497565","article-title":"Stress distribution within rotator cuff tendons with a crescent-shaped and an L-shaped tear","volume":"41","author":"Sano","year":"2013","journal-title":"Am J Sports Med"},{"issue":"2","key":"10.1016\/j.jos.2020.02.017_bib21","doi-asserted-by":"crossref","first-page":"83","DOI":"10.1016\/j.jse.2009.12.012","article-title":"Arthroscopic rotator cuff repair: scientific rationale, surgical technique, and early clinical and functional results of a knotless self-reinforcing double-row rotator cuff repair system","volume":"19","author":"Vaishnav","year":"2010","journal-title":"J\u00a0Shoulder Elb Surg"},{"issue":"3","key":"10.1016\/j.jos.2020.02.017_bib22","doi-asserted-by":"crossref","first-page":"371","DOI":"10.1302\/0301-620X.76B3.8175836","article-title":"Mechanical strength of repairs of the rotator cuff","volume":"76","author":"Gerber","year":"1994","journal-title":"J\u00a0Bone Jt Surg Br"},{"issue":"11","key":"10.1016\/j.jos.2020.02.017_bib23","doi-asserted-by":"crossref","first-page":"1463","DOI":"10.1016\/j.arthro.2010.04.075","article-title":"A\u00a0biomechanical comparison of the pullout strength of No. 2 FiberWire suture and 2-mm FiberWire tape in bovine rotator cuff tendons","volume":"26","author":"Bisson","year":"2010","journal-title":"Arthroscopy"},{"issue":"6","key":"10.1016\/j.jos.2020.02.017_bib24","doi-asserted-by":"crossref","first-page":"789","DOI":"10.1007\/s00776-012-0275-z","article-title":"The failure mode of two reabsorbable fixation systems: Swivelock with Fibertape versus Bio-Corkscrew with Fiberwire in bovine rotator cuff","volume":"17","author":"De Carli","year":"2012","journal-title":"J\u00a0Orthop Sci"},{"issue":"6","key":"10.1016\/j.jos.2020.02.017_bib25","doi-asserted-by":"crossref","first-page":"732","DOI":"10.1016\/j.jos.2016.07.001","article-title":"Biomechanical study comparing 3 fixation methods for rotator cuff massive tear: transosseous no. 2 suture, transosseous braided tape, and double-row","volume":"21","author":"Hinse","year":"2016","journal-title":"J\u00a0Orthop Sci"},{"issue":"4","key":"10.1016\/j.jos.2020.02.017_bib26","doi-asserted-by":"crossref","DOI":"10.1177\/2325967117701212","article-title":"Tape versus suture in arthroscopic rotator cuff repair: biomechanical analysis and assessment of failure rates at 6 Months","volume":"5","author":"Liu","year":"2017","journal-title":"Orthop J Sports Med"}],"container-title":["Journal of Orthopaedic Science"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0949265820300695?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0949265820300695?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,15]],"date-time":"2025-10-15T19:31:19Z","timestamp":1760556679000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0949265820300695"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,3]]},"references-count":26,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2021,3]]}},"alternative-id":["S0949265820300695"],"URL":"https:\/\/doi.org\/10.1016\/j.jos.2020.02.017","relation":{},"ISSN":["0949-2658"],"issn-type":[{"value":"0949-2658","type":"print"}],"subject":[],"published":{"date-parts":[[2021,3]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Comparison between single and double suture passing techniques in the suture bridge rotator cuff repair with a 2-mm tape: A simulation study using a three-dimensional finite element method","name":"articletitle","label":"Article Title"},{"value":"Journal of Orthopaedic Science","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jos.2020.02.017","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2020 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.","name":"copyright","label":"Copyright"}]}}