{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,15]],"date-time":"2025-10-15T20:11:26Z","timestamp":1760559086369,"version":"build-2065373602"},"reference-count":21,"publisher":"Elsevier BV","issue":"3","license":[{"start":{"date-parts":[[2022,5,1]],"date-time":"2022-05-01T00:00:00Z","timestamp":1651363200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2022,5,1]],"date-time":"2022-05-01T00:00:00Z","timestamp":1651363200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2023,5,16]],"date-time":"2023-05-16T00:00:00Z","timestamp":1684195200000},"content-version":"am","delay-in-days":380,"URL":"http:\/\/www.elsevier.com\/open-access\/userlicense\/1.0\/"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Orthopaedic Science"],"published-print":{"date-parts":[[2022,5]]},"DOI":"10.1016\/j.jos.2021.03.004","type":"journal-article","created":{"date-parts":[[2021,5,4]],"date-time":"2021-05-04T01:11:02Z","timestamp":1620090662000},"page":"574-581","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":2,"title":["Evaluation of vertebral bone strength with a finite element method using low dose computed tomography imaging"],"prefix":"10.1016","volume":"27","author":[{"given":"Koki","family":"Nakanowatari","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1889-4199","authenticated-orcid":false,"given":"Kunihiro","family":"Watanabe","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Koichi","family":"Mori","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Syuichi","family":"Nakajima","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Norio","family":"Sekine","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hirotaka","family":"Mutsuzaki","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"issue":"6","key":"10.1016\/j.jos.2021.03.004_bib1","doi-asserted-by":"crossref","first-page":"785","DOI":"10.1001\/jama.285.6.785","article-title":"Diagnosis, and Therapy. Osteoporosis prevention, diagnosis, and therapy","volume":"285","author":"Nih Consensus Development Panel on Osteoporosis Prevention","year":"2001","journal-title":"J\u00a0Am Med Assoc"},{"issue":"12","key":"10.1016\/j.jos.2021.03.004_bib2","doi-asserted-by":"crossref","first-page":"299","DOI":"10.1177\/1759720X17732562","article-title":"Critical issues and current challenges in osteoporosis and fracture prevention. An overview of unmet needs","volume":"9","author":"Lems","year":"2017","journal-title":"Ther Adv Musculoskelet Dis"},{"issue":"10","key":"10.1016\/j.jos.2021.03.004_bib3","doi-asserted-by":"crossref","first-page":"1828","DOI":"10.1359\/JBMR.050610","article-title":"Multi-detector row CT imaging of vertebral microstructure for evaluation of fracture risk","volume":"20","author":"Ito","year":"2005","journal-title":"J\u00a0Bone Miner Res"},{"key":"10.1016\/j.jos.2021.03.004_bib4","doi-asserted-by":"crossref","DOI":"10.1007\/s00330-020-07655-2","article-title":"Automatic opportunistic osteoporosis screening in routine CT: improved prediction of patients with prevalent vertebral fractures compared to DXA","author":"L\u00f6ffler","year":"2021","journal-title":"Eur Radiol"},{"issue":"2","key":"10.1016\/j.jos.2021.03.004_bib5","doi-asserted-by":"crossref","first-page":"56","DOI":"10.3390\/medicina56020056","article-title":"Development of a knee joint CT-FEM model in load response of the stance phase during walking using muscle exertion, motion analysis, and ground reaction force data","volume":"56","author":"Watanabe","year":"2020","journal-title":"Medicina"},{"issue":"1031","key":"10.1016\/j.jos.2021.03.004_bib6","doi-asserted-by":"crossref","first-page":"20130388","DOI":"10.1259\/bjr.20130388","article-title":"Six iterative reconstruction algorithms in brain CT: a phantom study on image quality at different radiation dose levels","volume":"86","author":"L\u00f6ve","year":"2013","journal-title":"Br J Radiol"},{"key":"10.1016\/j.jos.2021.03.004_bib7","doi-asserted-by":"crossref","first-page":"442","DOI":"10.3389\/fendo.2020.00442","article-title":"Finite element analysis-based vertebral bone strength prediction using MDCT data: how low can we go?","volume":"11","author":"Rayudu","year":"2020","journal-title":"Front Endocrinol"},{"issue":"1","key":"10.1016\/j.jos.2021.03.004_bib8","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1097\/BRS.0b013e31815e3993","article-title":"In\u00a0vivo assessment of lumbar vertebral strength in elderly women using computed tomography-based nonlinear finite element model","volume":"33","author":"Imai","year":"2008","journal-title":"Spine"},{"issue":"2","key":"10.1016\/j.jos.2021.03.004_bib9","doi-asserted-by":"crossref","first-page":"140","DOI":"10.1097\/00007632-199701150-00004","article-title":"Load sharing between the shell and centrum in the lumbar vertebral body","volume":"22","author":"Silva","year":"1997","journal-title":"Spine"},{"issue":"4","key":"10.1016\/j.jos.2021.03.004_bib10","first-page":"953","article-title":"Biomechanical study of vertebral compression fracture using finite element analysis","volume":"5","author":"Takano","year":"2017","journal-title":"J\u00a0Appl Math Phys"},{"issue":"22","key":"10.1016\/j.jos.2021.03.004_bib11","doi-asserted-by":"crossref","first-page":"E1291","DOI":"10.1097\/BRS.0000000000000540","article-title":"Specimen-specific nonlinear finite element modeling to predict vertebrae fracture loads after vertebroplasty","volume":"39","author":"Matsuura","year":"2014","journal-title":"Spine"},{"issue":"5","key":"10.1016\/j.jos.2021.03.004_bib12","doi-asserted-by":"crossref","first-page":"931","DOI":"10.1016\/j.jos.2017.05.015","article-title":"The risk assessment of pathological fracture in the proximal femur using a CT-based finite element method","volume":"22","author":"Kawabata","year":"2017","journal-title":"J\u00a0Orthop Sci"},{"issue":"2","key":"10.1016\/j.jos.2021.03.004_bib13","doi-asserted-by":"crossref","first-page":"12533","DOI":"10.1016\/S0021-9290(97)00123-1","article-title":"Prediction of femoral fracture load using automated finite element modelling","volume":"31","author":"Keyak","year":"1997","journal-title":"J\u00a0Biomech"},{"issue":"6","key":"10.1016\/j.jos.2021.03.004_bib14","doi-asserted-by":"crossref","first-page":"1239","DOI":"10.1016\/j.bone.2011.03.682","article-title":"Male-female differences in the association between incident hip fracture and proximal femoral strength: a finite element analysis study","volume":"48","author":"Keyak","year":"2011","journal-title":"Bone"},{"issue":"1","key":"10.1016\/j.jos.2021.03.004_bib15","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1002\/jez.1888","article-title":"Mechanical properties of the hyomandibula in four shark species","volume":"323","author":"Balaban","year":"2015","journal-title":"J\u00a0Exp Zool A Ecol Genet Physiol"},{"issue":"5","key":"10.1016\/j.jos.2021.03.004_bib16","doi-asserted-by":"crossref","first-page":"842","DOI":"10.1007\/s00167-010-1383-y","article-title":"Optimal double screw configuration for subtalar arthrodesis: a finite element analysis","volume":"19","author":"Lee","year":"2011","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"issue":"4","key":"10.1016\/j.jos.2021.03.004_bib17","doi-asserted-by":"crossref","first-page":"285","DOI":"10.1080\/10255849908907993","article-title":"A\u00a0three-dimensional finite element scheme to investigate the apparent mechanical properties of trabecular bone","volume":"2","author":"Saxena","year":"1999","journal-title":"Comput Methods Biomech Biomed Eng"},{"key":"10.1016\/j.jos.2021.03.004_bib18","first-page":"103","article-title":"Material properties and scalar display of knee joint in finite element analysis using quantitative CT images","volume":"25","author":"Watanabe","year":"2020","journal-title":"Acta Scientiarvm Valetvdinis Universitatis Praefectvralis Ibarakiensis"},{"issue":"7","key":"10.1016\/j.jos.2021.03.004_bib19","doi-asserted-by":"crossref","first-page":"537","DOI":"10.6009\/jjrt.2017_JSRT_73.7.537","article-title":"Proposal of a new index based on signal-to-noise ratio for low-contrast detectability in computed tomographic imaging","volume":"73","author":"Hashimoto","year":"2017","journal-title":"Nippon Hoshasen Gijutsu Gakkai Zasshi"},{"issue":"2","key":"10.1016\/j.jos.2021.03.004_bib20","first-page":"90","article-title":"Prediction of compression fracture risk of lumbar vertebra using a X\u2212ray CT\u2212based finite element method","volume":"16","author":"Okubo","year":"2013","journal-title":"Japan Academy of Health Science"},{"key":"10.1016\/j.jos.2021.03.004_bib21","first-page":"16","article-title":"The physiology of the joints","volume":"vol. 3","author":"Kapandji","year":"2008"}],"container-title":["Journal of Orthopaedic Science"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0949265821001214?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0949265821001214?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,15]],"date-time":"2025-10-15T19:34:07Z","timestamp":1760556847000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0949265821001214"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,5]]},"references-count":21,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2022,5]]}},"alternative-id":["S0949265821001214"],"URL":"https:\/\/doi.org\/10.1016\/j.jos.2021.03.004","relation":{},"ISSN":["0949-2658"],"issn-type":[{"type":"print","value":"0949-2658"}],"subject":[],"published":{"date-parts":[[2022,5]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Evaluation of vertebral bone strength with a finite element method using low dose computed tomography imaging","name":"articletitle","label":"Article Title"},{"value":"Journal of Orthopaedic Science","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jos.2021.03.004","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2021 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.","name":"copyright","label":"Copyright"}]}}