{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,6,5]],"date-time":"2025-06-05T00:40:02Z","timestamp":1749084002260,"version":"3.41.0"},"reference-count":17,"publisher":"Elsevier BV","issue":"1","license":[{"start":{"date-parts":[[2024,1,1]],"date-time":"2024-01-01T00:00:00Z","timestamp":1704067200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2024,1,1]],"date-time":"2024-01-01T00:00:00Z","timestamp":1704067200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Orthopaedic Science"],"published-print":{"date-parts":[[2024,1]]},"DOI":"10.1016\/j.jos.2022.11.012","type":"journal-article","created":{"date-parts":[[2022,12,7]],"date-time":"2022-12-07T05:54:28Z","timestamp":1670392468000},"page":"138-140","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":1,"title":["Isolated A1 pulley release surgery for trigger finger leads to significant increase in tip-to-tip pinch strength"],"prefix":"10.1016","volume":"29","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-3695-9884","authenticated-orcid":false,"given":"Kadir","family":"Uzel","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Velat","family":"\u00c7elik","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Atilla","family":"Ar\u0131k","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Can Emre","family":"Ba\u015f","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Metin Manouchehr","family":"Eskandari","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"issue":"4","key":"10.1016\/j.jos.2022.11.012_bib1","doi-asserted-by":"crossref","first-page":"338.e1","DOI":"10.1016\/j.jhsa.2018.06.023","article-title":"Factors causing prolonged postoperative symptoms despite absence of complications after A1 pulley release for trigger finger","author":"Baek","year":"2019","journal-title":"J\u00a0Hand Surg Am"},{"issue":"4","key":"10.1016\/j.jos.2022.11.012_bib2","doi-asserted-by":"crossref","first-page":"227","DOI":"10.1007\/s11552-007-9065-z","article-title":"Treating trigger finger in diabetics using excision of the ulnar slip of the flexor digitorum superficialis with or without A1 pulley release","author":"Marcus","year":"2007","journal-title":"Hand (N Y)."},{"issue":"5","key":"10.1016\/j.jos.2022.11.012_bib3","doi-asserted-by":"crossref","first-page":"537","DOI":"10.1097\/SAP.0000000000001561","article-title":"Does bowstringing affect hand function in patients treated with A1 pulley release for trigger fingers?: comparison between percutaneous versus open technique","volume":"81","author":"Park","year":"2018","journal-title":"Ann Plast Surg"},{"issue":"2","key":"10.1016\/j.jos.2022.11.012_bib4","first-page":"1","article-title":"Comparative study of ultrasonography-guided percutaneous A1 pulley release versus blinded percutaneous A1 pulley release","author":"Lee","year":"2018","journal-title":"J\u00a0Orthop Surg (Hong Kong)"},{"issue":"1","key":"10.1016\/j.jos.2022.11.012_bib5","doi-asserted-by":"crossref","first-page":"93","DOI":"10.1093\/rheumatology\/ker315","article-title":"Treatment of trigger finger: randomized clinical trial comparing the methods of corticosteroid injection, percutaneous release and open surgery","author":"Sato","year":"2012","journal-title":"Rheumatology (Oxford)"},{"issue":"3","key":"10.1016\/j.jos.2022.11.012_bib6","doi-asserted-by":"crossref","first-page":"202","DOI":"10.1007\/s00132-018-03676-4","article-title":"Stenosing tenosynovitis : evaluation of percutaneous release with a specially designed needle vs. open surgery","author":"Xie","year":"2019","journal-title":"Orthop\u00e4"},{"issue":"1","key":"10.1016\/j.jos.2022.11.012_bib7","first-page":"52","article-title":"How many trigger fingers resolve spontaneously without any treatment?","author":"D, Lalonde","year":"2018","journal-title":"Plast Surg (Oakv)."},{"issue":"1","key":"10.1016\/j.jos.2022.11.012_bib8","doi-asserted-by":"crossref","first-page":"158","DOI":"10.1142\/S2424835518710017","article-title":"Endoscopic trigger finger release: surgical technique","author":"Duncan","year":"2018","journal-title":"J\u00a0Hand Surg Asian Pac"},{"issue":"3","key":"10.1016\/j.jos.2022.11.012_bib9","doi-asserted-by":"crossref","first-page":"260","DOI":"10.1177\/1753193408087070","article-title":"A\u00a0prospective clinical study of the A1 pulley in trigger thumbs","author":"Boretto","year":"2008","journal-title":"J\u00a0Hand Surg Eur"},{"issue":"1","key":"10.1016\/j.jos.2022.11.012_bib10","doi-asserted-by":"crossref","first-page":"67","DOI":"10.1097\/01.bpo.0000187996.02140.1c","article-title":"Percutaneous trigger thumb release in children","author":"Ruiz-Iban","year":"2006","journal-title":"J\u00a0Pediatr Orthop"},{"issue":"1","key":"10.1016\/j.jos.2022.11.012_bib11","doi-asserted-by":"crossref","first-page":"46","DOI":"10.1016\/S0266-7681(98)80217-9","article-title":"The effect of the extent of A1 pulley release on the force required to flex the digits. A cadaver study on the thumb, middle and ring fingers","author":"Low","year":"1998","journal-title":"J\u00a0Hand Surg Br"},{"key":"10.1016\/j.jos.2022.11.012_bib12","doi-asserted-by":"crossref","DOI":"10.1155\/2017\/9539206","article-title":"Evaluating hand function in clients with trigger finger","volume":"2017","author":"Langer","year":"2017","journal-title":"Occup Ther Int"},{"issue":"2","key":"10.1016\/j.jos.2022.11.012_bib13","doi-asserted-by":"crossref","first-page":"222","DOI":"10.1016\/S0363-5023(84)80146-X","article-title":"Reliability and validity of grip and pinch strength evaluations","author":"Mathiowetz","year":"1984","journal-title":"J\u00a0Hand Surg Am"},{"issue":"7","key":"10.1016\/j.jos.2022.11.012_bib14","doi-asserted-by":"crossref","first-page":"444","DOI":"10.5014\/ajot.43.7.444","article-title":"Grip strength and hand dominance: challenging the 10% rule","author":"Petersen","year":"1989","journal-title":"Am J Occup Ther"},{"issue":"4","key":"10.1016\/j.jos.2022.11.012_bib15","doi-asserted-by":"crossref","first-page":"567","DOI":"10.1016\/S0363-5023(88)80097-2","article-title":"Bowstringing as a complication of trigger finger release","author":"Heithoff","year":"1988","journal-title":"J\u00a0Hand Surg Am"},{"issue":"6","key":"10.1016\/j.jos.2022.11.012_bib16","doi-asserted-by":"crossref","first-page":"822","DOI":"10.1016\/j.bjps.2014.01.041","article-title":"The role of proximal pulleys in preventing tendon bowstringing: pulley rupture and tendon bowstringing","author":"Leeflang","year":"2014","journal-title":"J\u00a0Plast Reconstr Aesthetic Surg"},{"issue":"2","key":"10.1016\/j.jos.2022.11.012_bib17","doi-asserted-by":"crossref","first-page":"347","DOI":"10.2214\/ajr.167.2.8686601","article-title":"Bowstring injury of the flexor tendon pulley system: MR imaging","author":"Parellada","year":"1996","journal-title":"AJR Am J Roentgenol"}],"container-title":["Journal of Orthopaedic Science"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0949265822003256?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0949265822003256?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,6,5]],"date-time":"2025-06-05T00:20:39Z","timestamp":1749082839000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0949265822003256"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,1]]},"references-count":17,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2024,1]]}},"alternative-id":["S0949265822003256"],"URL":"https:\/\/doi.org\/10.1016\/j.jos.2022.11.012","relation":{},"ISSN":["0949-2658"],"issn-type":[{"type":"print","value":"0949-2658"}],"subject":[],"published":{"date-parts":[[2024,1]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Isolated A1 pulley release surgery for trigger finger leads to significant increase in tip-to-tip pinch strength","name":"articletitle","label":"Article Title"},{"value":"Journal of Orthopaedic Science","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jos.2022.11.012","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2022 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.","name":"copyright","label":"Copyright"}]}}