{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,9]],"date-time":"2026-11-09T21:00:27Z","timestamp":1794258027524,"version":"4.9.0"},"reference-count":34,"publisher":"Elsevier BV","issue":"3","license":[{"start":{"date-parts":[[2024,5,1]],"date-time":"2024-05-01T00:00:00Z","timestamp":1714521600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2024,5,1]],"date-time":"2024-05-01T00:00:00Z","timestamp":1714521600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.fr","clinicalkey.jp","clinicalkey.es","clinicalkey.com.au","clinicalkey.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Orthopaedic Science"],"published-print":{"date-parts":[[2024,5]]},"DOI":"10.1016\/j.jos.2023.04.009","type":"journal-article","created":{"date-parts":[[2023,5,15]],"date-time":"2023-05-15T13:04:15Z","timestamp":1684155855000},"page":"867-873","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":2,"title":["Anterior cortical line of femur and tibia is more accurate than mid-shaft line to determine knee extension angle relative to sagittal mechanical axis during total knee arthroplasty"],"prefix":"10.1016","volume":"29","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-3305-7591","authenticated-orcid":false,"given":"Anuwat","family":"Pongkunakorn","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tharanas","family":"Jantharagsarangsee","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Parinthorn","family":"Triamsasithorn","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"issue":"1","key":"10.1016\/j.jos.2023.04.009_bib1","first-page":"42","article-title":"Computer-assisted navigation for the assessment of fixed flexion in knee arthroplasty","volume":"53","author":"Gallie","year":"2010","journal-title":"Can J Surg"},{"issue":"9","key":"10.1016\/j.jos.2023.04.009_bib2","doi-asserted-by":"crossref","first-page":"2924","DOI":"10.1007\/s00167-019-05675-0","article-title":"Effect of additional distal femoral resection on flexion deformity in posterior-stabilized total knee arthroplasty","volume":"28","author":"Matziolis","year":"2020","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"issue":"2","key":"10.1016\/j.jos.2023.04.009_bib3","doi-asserted-by":"crossref","first-page":"146","DOI":"10.1097\/MRR.0b013e32835b8269","article-title":"Reliability of a smartphone-based goniometer for knee joint goniometry","volume":"36","author":"Ferriero","year":"2013","journal-title":"Int J Rehabil Res"},{"issue":"2","key":"10.1016\/j.jos.2023.04.009_bib4","doi-asserted-by":"crossref","first-page":"47","DOI":"10.2340\/165019771986184749","article-title":"Radiographic verification of knee goniometry","volume":"18","author":"Enwemeka","year":"1986","journal-title":"Scand J Rehabil Med"},{"key":"10.1016\/j.jos.2023.04.009_bib5","doi-asserted-by":"crossref","first-page":"83","DOI":"10.1186\/1471-2474-8-83","article-title":"Reproducibility of goniometric measurement of the knee in the in-hospital phase following total knee arthroplasty","volume":"8","author":"Lenssen","year":"2007","journal-title":"BMC Muscoskel Disord"},{"issue":"2","key":"10.1016\/j.jos.2023.04.009_bib6","doi-asserted-by":"crossref","first-page":"192","DOI":"10.1093\/ptj\/67.2.192","article-title":"Reliability and validity of goniometric measurements at the knee","volume":"67","author":"Gogia","year":"1987","journal-title":"Phys Ther"},{"issue":"3","key":"10.1016\/j.jos.2023.04.009_bib7","doi-asserted-by":"crossref","first-page":"396","DOI":"10.1053\/apmr.2001.19250","article-title":"Intra- and intertester reliability and criterion validity of the parallelogram and universal goniometers for measuring maximum active knee flexion and extension of patients with knee restrictions","volume":"82","author":"Brosseau","year":"2001","journal-title":"Arch Phys Med Rehabil"},{"issue":"3","key":"10.1016\/j.jos.2023.04.009_bib8","doi-asserted-by":"crossref","first-page":"369","DOI":"10.1016\/j.arth.2003.12.001","article-title":"Measuring flexion in knee arthroplasty patients","volume":"19","author":"Edwards","year":"2004","journal-title":"J\u00a0Arthroplasty"},{"issue":"Suppl 6","key":"10.1016\/j.jos.2023.04.009_bib9","first-page":"S69","article-title":"The landmarks of centers of the distal femur and the proximal tibia in sagittal plane for application in computer assisted total knee arthroplasty","volume":"92","author":"Hangsaphuk","year":"2009","journal-title":"J\u00a0Med Assoc Thai"},{"issue":"11","key":"10.1016\/j.jos.2023.04.009_bib10","doi-asserted-by":"crossref","first-page":"1603","DOI":"10.2106\/00004623-200011000-00014","article-title":"Axial alignment of the lower extremity in Chinese adults","volume":"82","author":"Tang","year":"2000","journal-title":"J\u00a0Bone Joint Surg Am"},{"issue":"1","key":"10.1016\/j.jos.2023.04.009_bib11","doi-asserted-by":"crossref","first-page":"127","DOI":"10.1186\/s13018-017-0626-8","article-title":"The assessment of femoral shaft morphology in the sagittal plane in Chinese patients with osteoarthritis-a radiographic analysis","volume":"12","author":"Bao","year":"2017","journal-title":"J\u00a0Orthop Surg Res"},{"issue":"9","key":"10.1016\/j.jos.2023.04.009_bib12","doi-asserted-by":"crossref","first-page":"2403","DOI":"10.1007\/s11999-009-0762-5","article-title":"Differences between sagittal femoral mechanical and distal reference axes should be considered in navigated TKA","volume":"467","author":"Chung","year":"2009","journal-title":"Clin Orthop Relat Res"},{"issue":"3","key":"10.1016\/j.jos.2023.04.009_bib13","doi-asserted-by":"crossref","first-page":"128","DOI":"10.4055\/cios.2009.1.3.128","article-title":"Bony landmarks for determining the mechanical axis of the femur in the sagittal plane during total knee arthroplasty","volume":"1","author":"Seo","year":"2009","journal-title":"Clin Orthop Surg"},{"issue":"4","key":"10.1016\/j.jos.2023.04.009_bib14","doi-asserted-by":"crossref","first-page":"373","DOI":"10.1007\/s00167-008-0486-1","article-title":"Evaluation of anatomic references for tibial sagittal alignment in total knee arthroplasty","volume":"16","author":"Han","year":"2008","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"issue":"4","key":"10.1016\/j.jos.2023.04.009_bib15","doi-asserted-by":"crossref","first-page":"586","DOI":"10.1016\/j.arth.2007.05.006","article-title":"Anatomical references to assess the posterior tibial slope in total knee arthroplasty: a comparison of 5 anatomical axes","volume":"23","author":"Yoo","year":"2008","journal-title":"J\u00a0Arthroplasty"},{"key":"10.1016\/j.jos.2023.04.009_bib16","series-title":"Principles of deformity correction","first-page":"155","article-title":"Sagittal plane deformities","author":"Paley","year":"2002"},{"issue":"12","key":"10.1016\/j.jos.2023.04.009_bib17","first-page":"E249","article-title":"Knee range of motion: reliability and agreement of 3 measurement methods","volume":"40","author":"Peters","year":"2011","journal-title":"Am J Orthop (Belle Mead NJ)"},{"issue":"5","key":"10.1016\/j.jos.2023.04.009_bib18","doi-asserted-by":"crossref","first-page":"601","DOI":"10.1302\/0301-620X.88B5.17431","article-title":"Accuracy of a computer-assisted navigation system for total knee replacement","volume":"88","author":"Pitto","year":"2006","journal-title":"J\u00a0Bone Joint Surg Br"},{"key":"10.1016\/j.jos.2023.04.009_bib19","series-title":"Sample size calculations in clinical research","author":"Chow","year":"2008"},{"issue":"4","key":"10.1016\/j.jos.2023.04.009_bib20","first-page":"250","article-title":"The effect of sagittal femoral bowing on the femoral component position in total knee arthroplasty","volume":"5","author":"Kazemi","year":"2017","journal-title":"Arch Bone Jt Surg"},{"issue":"7","key":"10.1016\/j.jos.2023.04.009_bib21","doi-asserted-by":"crossref","first-page":"1476","DOI":"10.1016\/j.arth.2019.02.051","article-title":"Sagittal alignment of the femoral component and patient height are associated with persisting flexion contracture after primary total knee arthroplasty","volume":"34","author":"Okamoto","year":"2019","journal-title":"J\u00a0Arthroplasty"},{"issue":"2","key":"10.1016\/j.jos.2023.04.009_bib22","doi-asserted-by":"crossref","first-page":"379","DOI":"10.1007\/s00264-013-2097-9","article-title":"The relationship between the survival of total knee arthroplasty and postoperative coronal, sagittal and rotational alignment of knee prosthesis","volume":"38","author":"Kim","year":"2014","journal-title":"Int Orthop"},{"issue":"5","key":"10.1016\/j.jos.2023.04.009_bib23","doi-asserted-by":"crossref","first-page":"784","DOI":"10.1016\/j.arth.2012.11.013","article-title":"Measurement of the knee flexion angle with a smartphone-application is precise and accurate","volume":"28","author":"Jenny","year":"2013","journal-title":"J\u00a0Arthroplasty"},{"issue":"5","key":"10.1016\/j.jos.2023.04.009_bib24","doi-asserted-by":"crossref","first-page":"385","DOI":"10.1016\/j.knee.2007.07.004","article-title":"Digital goniometric measurement of knee joint motion. Evaluation of usefulness for research settings and clinical practice","volume":"14","author":"Cleffken","year":"2007","journal-title":"Knee"},{"issue":"4","key":"10.1016\/j.jos.2023.04.009_bib25","doi-asserted-by":"crossref","first-page":"378","DOI":"10.3138\/physio.62.4.378","article-title":"Modelling knee range of motion post arthroplasty: clinical applications","volume":"62","author":"Stratford","year":"2010","journal-title":"Physiother Can"},{"issue":"12","key":"10.1016\/j.jos.2023.04.009_bib26","doi-asserted-by":"crossref","first-page":"2579","DOI":"10.2106\/JBJS.G.00995","article-title":"Knee range of motion during the first two years after use of posterior cruciate-stabilizing or posterior cruciate-retaining total knee prostheses. A randomized clinical trial","volume":"90","author":"Chaudhary","year":"2008","journal-title":"J\u00a0Bone Joint Surg Am"},{"issue":"6","key":"10.1016\/j.jos.2023.04.009_bib27","doi-asserted-by":"crossref","first-page":"569","DOI":"10.1016\/j.math.2014.05.009","article-title":"Reliability and concurrent validity of knee angle measurement: smart phone app versus universal goniometer used by experienced and novice clinicians","volume":"19","author":"Milanese","year":"2014","journal-title":"Man Ther"},{"issue":"1","key":"10.1016\/j.jos.2023.04.009_bib28","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1186\/s43019-020-00038-3","article-title":"Minimal clinically important difference of commonly used patient-reported outcome measures in total knee arthroplasty: review of terminologies, methods and proposed values","volume":"32","author":"Maredupaka","year":"2020","journal-title":"Knee Surg Relat Res"},{"key":"10.1016\/j.jos.2023.04.009_bib29","year":"2016"},{"issue":"1","key":"10.1016\/j.jos.2023.04.009_bib30","doi-asserted-by":"crossref","first-page":"132","DOI":"10.1002\/jor.1100070118","article-title":"Tibial anatomy and functional axes","volume":"7","author":"Yoshioka","year":"1989","journal-title":"J\u00a0Orthop Res"},{"key":"10.1016\/j.jos.2023.04.009_bib31","doi-asserted-by":"crossref","first-page":"129","DOI":"10.1097\/01.blo.0000170873.88306.56","article-title":"Evaluation of methods that locate the center of the ankle for computer-assisted total knee arthroplasty","volume":"439","author":"Siston","year":"2005","journal-title":"Clin Orthop Relat Res"},{"issue":"5","key":"10.1016\/j.jos.2023.04.009_bib32","first-page":"2521","article-title":"Fluoroscopic intraoperative images produce higher image quality and decrease total radiation exposure compared to radiographic x-ray images in patients after primary total knee arthroplasty","volume":"34","author":"Graulich","year":"2020","journal-title":"In\u00a0Vivo"},{"key":"10.1016\/j.jos.2023.04.009_bib33","series-title":"Knee3 surgical technique","year":"2015"},{"key":"10.1016\/j.jos.2023.04.009_bib34","series-title":"OrthoMap express knee product guide","year":"2012"}],"container-title":["Journal of Orthopaedic Science"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0949265823001240?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0949265823001240?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2024,5,22]],"date-time":"2024-05-22T01:45:50Z","timestamp":1716342350000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0949265823001240"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,5]]},"references-count":34,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2024,5]]}},"alternative-id":["S0949265823001240"],"URL":"https:\/\/doi.org\/10.1016\/j.jos.2023.04.009","relation":{},"ISSN":["0949-2658"],"issn-type":[{"value":"0949-2658","type":"print"}],"subject":[],"published":{"date-parts":[[2024,5]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Anterior cortical line of femur and tibia is more accurate than mid-shaft line to determine knee extension angle relative to sagittal mechanical axis during total knee arthroplasty","name":"articletitle","label":"Article Title"},{"value":"Journal of Orthopaedic Science","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jos.2023.04.009","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2023 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights are reserved, including those for text and data mining, AI training, and similar technologies.","name":"copyright","label":"Copyright"}]}}