{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,11]],"date-time":"2026-03-11T03:42:08Z","timestamp":1773200528017,"version":"3.50.1"},"reference-count":17,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2025,9,1]],"date-time":"2025-09-01T00:00:00Z","timestamp":1756684800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2025,9,1]],"date-time":"2025-09-01T00:00:00Z","timestamp":1756684800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2025,6,25]],"date-time":"2025-06-25T00:00:00Z","timestamp":1750809600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["jprasopen.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["JPRAS Open"],"published-print":{"date-parts":[[2025,9]]},"DOI":"10.1016\/j.jpra.2025.06.016","type":"journal-article","created":{"date-parts":[[2025,7,2]],"date-time":"2025-07-02T03:54:51Z","timestamp":1751428491000},"page":"317-325","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":1,"special_numbering":"C","title":["Long-term outcomes of flap reconstruction for hardware exposure in low-energy distal tibia fractures"],"prefix":"10.1016","volume":"45","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-7628-3164","authenticated-orcid":false,"given":"Eleni","family":"Karagergou","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6063-8650","authenticated-orcid":false,"given":"Dimitrios","family":"Kitridis","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ektoras","family":"Kessidis","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9760-004X","authenticated-orcid":false,"given":"Nikolaos Platon","family":"Sachinis","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Alexandros","family":"Givissis","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8649-1159","authenticated-orcid":false,"given":"Panagiotis","family":"Givissis","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"issue":"4","key":"10.1016\/j.jpra.2025.06.016_bib0001","doi-asserted-by":"crossref","first-page":"253","DOI":"10.5435\/00124635-200007000-00006","article-title":"Complications after treatment of tibial pilon fractures: prevention and management strategies","volume":"8","author":"Thordarson","year":"2000","journal-title":"J Am Acad Orthop Surg"},{"key":"10.1016\/j.jpra.2025.06.016_bib0002","doi-asserted-by":"crossref","first-page":"107","DOI":"10.1097\/00003086-199307000-00013","article-title":"Open reduction and internal fixation of tibial plafond fractures. Variables contributing to poor results and complications","volume":"292","author":"Teeny","year":"1993","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.jpra.2025.06.016_bib0003","doi-asserted-by":"crossref","first-page":"543","DOI":"10.2106\/00004623-198668040-00010","article-title":"Fractures of the tibial plafond","volume":"68","author":"Ovadia","year":"1986","journal-title":"J Bone Joint Surg [Am]"},{"key":"10.1016\/j.jpra.2025.06.016_bib0004","doi-asserted-by":"crossref","first-page":"505","DOI":"10.1016\/j.injury.2017.08.040","article-title":"Fracture-related infection: a consensus on definition from an international expert group","volume":"49","author":"Metsemakers","year":"2018","journal-title":"Injury"},{"key":"10.1016\/j.jpra.2025.06.016_bib0005","doi-asserted-by":"crossref","first-page":"468","DOI":"10.1302\/2058-5241.4.180093","article-title":"Infection after fracture fixation","volume":"4","author":"Steinmetz","year":"2019","journal-title":"EFFORT Open Rev"},{"issue":"1S","key":"10.1016\/j.jpra.2025.06.016_bib0006","doi-asserted-by":"crossref","first-page":"S67","DOI":"10.1016\/j.otsr.2016.06.019","article-title":"Operative treatment of early infection after internal fixation of limb fractures (exclusive of severe open fractures)","volume":"103","author":"Bonnevialle","year":"2017","journal-title":"Orthop Traumatol Surg Res"},{"key":"10.1016\/j.jpra.2025.06.016_bib0007","doi-asserted-by":"crossref","first-page":"415","DOI":"10.1146\/annurev.med.59.110106.132000","article-title":"Bacterial and fungal biofilm infections","volume":"59","author":"Lynch","year":"2008","journal-title":"Annu Rev Med"},{"issue":"10","key":"10.1016\/j.jpra.2025.06.016_bib0008","doi-asserted-by":"crossref","DOI":"10.2196\/14397","article-title":"Development of a patient-reported outcome instrument for patients with severe lower extremity trauma (LIMB-Q): protocol for a multiphase mixed methods study","volume":"8","author":"Mundy","year":"2019","journal-title":"JMIR Res Protoc"},{"key":"10.1016\/j.jpra.2025.06.016_bib0009","doi-asserted-by":"crossref","first-page":"92","DOI":"10.1016\/S0020-1383(69)80066-5","article-title":"Fractures of the lower end of the tibia into the ankle joint","volume":"1","author":"Ruedi","year":"1969","journal-title":"Injury"},{"key":"10.1016\/j.jpra.2025.06.016_bib0010","doi-asserted-by":"crossref","first-page":"1183","DOI":"10.1016\/j.injury.2010.08.041","article-title":"Tibial pilon fractures: which method of treatment?","volume":"41","author":"Calori","year":"2010","journal-title":"Injury"},{"issue":"2","key":"10.1016\/j.jpra.2025.06.016_bib0011","doi-asserted-by":"crossref","first-page":"195","DOI":"10.1097\/00005131-199206000-00011","article-title":"Complications encountered in the treatment of pilon fractures","volume":"6","author":"McFerran","year":"1992","journal-title":"J Orthop Trauma"},{"issue":"8","key":"10.1016\/j.jpra.2025.06.016_bib0012","doi-asserted-by":"crossref","first-page":"S32","DOI":"10.1097\/00005131-200409001-00005","article-title":"A staged protocol for soft tissue management in the treatment of complex pilon fractures","volume":"18","author":"Sirkin","year":"2004","journal-title":"J Orthop Trauma"},{"key":"10.1016\/j.jpra.2025.06.016_bib0013","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1097\/00005131-199902000-00003","article-title":"Two-staged delayed open reduction and internal fixation of severe pilon fractures","volume":"13","author":"Patterson","year":"1999","journal-title":"J Orthop Trauma"},{"issue":"1","key":"10.1016\/j.jpra.2025.06.016_bib0014","doi-asserted-by":"crossref","first-page":"109","DOI":"10.1002\/micr.30047","article-title":"Free versus perforator-pedicled propeller flaps in lower extremity reconstruction: what is the safest coverage? A meta-analysis","volume":"38","author":"Bekara","year":"2018","journal-title":"Microsurgery"},{"key":"10.1016\/j.jpra.2025.06.016_bib0015","doi-asserted-by":"crossref","first-page":"578","DOI":"10.1002\/micr.22134","article-title":"A review of propeller flaps for distal lower extremity soft tissue reconstruction: is flap loss too high?","volume":"33","author":"Nelson","year":"2013","journal-title":"Microsurgery"},{"key":"10.1016\/j.jpra.2025.06.016_bib0016","doi-asserted-by":"crossref","first-page":"625","DOI":"10.1002\/micr.22162","article-title":"Distally based saphenous neurocutaneous perforator flap combined with VAC therapy for soft tissue reconstruction and hardware salvage in the lower extremities","volume":"33","author":"Wen","year":"2013","journal-title":"Microsurgery"},{"issue":"4","key":"10.1016\/j.jpra.2025.06.016_bib0017","doi-asserted-by":"crossref","first-page":"823","DOI":"10.2106\/JBJS.I.00470","article-title":"Maintenance of hardware after early postoperative infection following fracture internal fixation","volume":"92","author":"Berkes","year":"2010","journal-title":"J Bone Joint Surg Am"}],"container-title":["JPRAS Open"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2352587825001159?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2352587825001159?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,8,28]],"date-time":"2025-08-28T14:07:06Z","timestamp":1756390026000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2352587825001159"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,9]]},"references-count":17,"alternative-id":["S2352587825001159"],"URL":"https:\/\/doi.org\/10.1016\/j.jpra.2025.06.016","relation":{},"ISSN":["2352-5878"],"issn-type":[{"value":"2352-5878","type":"print"}],"subject":[],"published":{"date-parts":[[2025,9]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Long-term outcomes of flap reconstruction for hardware exposure in low-energy distal tibia fractures","name":"articletitle","label":"Article Title"},{"value":"JPRAS Open","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jpra.2025.06.016","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2025 The Author(s). Published by Elsevier Ltd on behalf of British Association of Plastic, Reconstructive and Aesthetic Surgeons.","name":"copyright","label":"Copyright"}]}}