{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,27]],"date-time":"2026-06-27T23:51:44Z","timestamp":1782604304222,"version":"3.54.5"},"reference-count":8,"publisher":"Elsevier BV","issue":"1","license":[{"start":{"date-parts":[[2011,2,1]],"date-time":"2011-02-01T00:00:00Z","timestamp":1296518400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2011,2,1]],"date-time":"2011-02-01T00:00:00Z","timestamp":1296518400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","jpurol.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Pediatric Urology"],"published-print":{"date-parts":[[2011,2]]},"DOI":"10.1016\/j.jpurol.2010.10.007","type":"journal-article","created":{"date-parts":[[2010,11,11]],"date-time":"2010-11-11T04:40:23Z","timestamp":1289450423000},"page":"95-97","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":13,"title":["The pitfalls of BladderScan\u2122 PVR in evaluating bladder volume in adolescent females"],"prefix":"10.1016","volume":"7","author":[{"given":"Sammy E.","family":"Elsamra","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zachary","family":"Gordon","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pamela I.","family":"Ellsworth","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.jpurol.2010.10.007_bib1","doi-asserted-by":"crossref","first-page":"341","DOI":"10.1016\/S0090-4295(97)00293-8","article-title":"Three-dimensional ultrasound device for rapid determination of bladder volume","volume":"50","author":"Marks","year":"1997","journal-title":"Urology"},{"key":"10.1016\/j.jpurol.2010.10.007_bib2","doi-asserted-by":"crossref","first-page":"654","DOI":"10.1016\/S0022-5347(17)63094-5","article-title":"Ultrasonic studies of the bladder","volume":"97","author":"Holmes","year":"1967","journal-title":"J Urol"},{"key":"10.1016\/j.jpurol.2010.10.007_bib3","doi-asserted-by":"crossref","first-page":"445","DOI":"10.1016\/0090-4295(88)90746-7","article-title":"Can transabdominal ultrasound estimation of postvoiding residual (PVR) replace catheterization?","volume":"31","author":"Roehrborn","year":"1988","journal-title":"Urology"},{"key":"10.1016\/j.jpurol.2010.10.007_bib4","doi-asserted-by":"crossref","first-page":"641","DOI":"10.1007\/s00192-006-0219-2","article-title":"Accuracy and precision of a new portable ultrasound scanner, the BME-150A, in residual urine volume measurement: a comparison with the BladderScan BVI 3000","volume":"18","author":"Choe","year":"2007","journal-title":"Int Urogynecol J Pelvic Floor Dysfunct"},{"key":"10.1016\/j.jpurol.2010.10.007_bib5","first-page":"163","article-title":"Ultrasound bladder scanner presents falsely elevated postvoid residual volumes","volume":"55","author":"Alagiakrishnan","year":"2009","journal-title":"Can Fam Physician"},{"key":"10.1016\/j.jpurol.2010.10.007_bib6","doi-asserted-by":"crossref","DOI":"10.1016\/S0090-4295(99)00565-8","article-title":"Cystic pelvic pathology presenting as falsely elevated post-void residual urine measured by portable ultrasound bladder scanning: report of 3 cases and review of the literature","volume":"55","author":"Cooperberg","year":"2000","journal-title":"Urology"},{"key":"10.1016\/j.jpurol.2010.10.007_bib7","doi-asserted-by":"crossref","first-page":"381","DOI":"10.1080\/003655900455477","article-title":"Erroneous diagnosis of chronic urinary retention in three women with pelvic cysts","volume":"34","author":"Dunn","year":"2000","journal-title":"Scand J Urol Nephrol"},{"key":"10.1016\/j.jpurol.2010.10.007_bib8","doi-asserted-by":"crossref","first-page":"356","DOI":"10.1093\/ageing\/32.3.356","article-title":"False positive findings in the ultrasound assessment of postvoid residual urine volume","volume":"32","author":"Tan","year":"2003","journal-title":"Age Ageing"}],"container-title":["Journal of Pediatric Urology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1477513110004857?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1477513110004857?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,26]],"date-time":"2025-10-26T13:36:10Z","timestamp":1761485770000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1477513110004857"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011,2]]},"references-count":8,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2011,2]]}},"alternative-id":["S1477513110004857"],"URL":"https:\/\/doi.org\/10.1016\/j.jpurol.2010.10.007","relation":{},"ISSN":["1477-5131"],"issn-type":[{"value":"1477-5131","type":"print"}],"subject":[],"published":{"date-parts":[[2011,2]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"The pitfalls of BladderScan\u2122 PVR in evaluating bladder volume in adolescent females","name":"articletitle","label":"Article Title"},{"value":"Journal of Pediatric Urology","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jpurol.2010.10.007","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2010 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.","name":"copyright","label":"Copyright"}]}}