{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,13]],"date-time":"2025-11-13T07:04:22Z","timestamp":1763017462867},"reference-count":18,"publisher":"Elsevier BV","issue":"2","license":[{"start":{"date-parts":[[2015,2,1]],"date-time":"2015-02-01T00:00:00Z","timestamp":1422748800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":["jshoulderelbow.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Shoulder and Elbow Surgery"],"published-print":{"date-parts":[[2015,2]]},"DOI":"10.1016\/j.jse.2014.09.019","type":"journal-article","created":{"date-parts":[[2014,11,6]],"date-time":"2014-11-06T17:26:36Z","timestamp":1415294796000},"page":"258-264","update-policy":"http:\/\/dx.doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":14,"title":["The effect of radial head implant shape on radiocapitellar kinematics during in\u00a0vitro forearm rotation"],"prefix":"10.1016","volume":"24","author":[{"given":"Hannah L.","family":"Shannon","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Simon R.","family":"Deluce","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Joshua W.","family":"Giles","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"James A.","family":"Johnson","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Graham J.W.","family":"King","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.jse.2014.09.019_bib1","doi-asserted-by":"crossref","first-page":"1730","DOI":"10.2106\/00004623-200408000-00018","article-title":"The effect of radial head excision and arthroplasty on elbow kinematics and stability","volume":"86","author":"Beingessner","year":"2004","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.jse.2014.09.019_bib2","doi-asserted-by":"crossref","first-page":"314","DOI":"10.1016\/j.jhsa.2005.12.005","article-title":"Radial head arthroplasty","volume":"31","author":"Calfee","year":"2006","journal-title":"J Hand Surg Am"},{"key":"10.1016\/j.jse.2014.09.019_bib3","doi-asserted-by":"crossref","first-page":"885","DOI":"10.1016\/j.jse.2011.03.009","article-title":"Influence of prosthetic design on radiocapitellar concavity-compression stability","volume":"20","author":"Chanlalit","year":"2011","journal-title":"J Shoulder Elbow Surg"},{"key":"10.1016\/j.jse.2014.09.019_bib4","unstructured":"Deluce SR, Shannon H, Lalone E, Ferreira LM, King GJ, Johnson JA. Comparison of population-based and patient-specific radial head implants using surface matching. Presented at the Orthopaedic Research Society 2013 Annual Meeting, San Antonio, TX; Jan 26-29,\u00a02013."},{"key":"10.1016\/j.jse.2014.09.019_bib5","unstructured":"Deluce SR, Shannon H, Lalone E, Ferreira LM, King GJ, Johnson JA. Development of a computer- and image-assisted guidance system for radial head arthroplasty. Presented at the Orthopaedic Research Society 2013 Annual Meeting, San Antonio, TX; Jan 26-29,\u00a02013."},{"key":"10.1016\/j.jse.2014.09.019_bib6","doi-asserted-by":"crossref","first-page":"2114","DOI":"10.1016\/j.jbiomech.2010.04.007","article-title":"Development of an active elbow flexion simulator to evaluate joint kinematics with the humerus in the horizontal position","volume":"43","author":"Ferreira","year":"2010","journal-title":"J Biomech"},{"key":"10.1016\/j.jse.2014.09.019_bib7","doi-asserted-by":"crossref","first-page":"596","DOI":"10.1002\/jor.21278","article-title":"Motion-derived coordinate systems reduce inter-subject variability of elbow flexion kinematics","volume":"29","author":"Ferreira","year":"2011","journal-title":"J\u00a0Orthop Res"},{"key":"10.1016\/j.jse.2014.09.019_bib8","doi-asserted-by":"crossref","first-page":"615","DOI":"10.1097\/BOT.0b013e3181886f37","article-title":"Lateral collateral ligament repair restores the initial varus stability of the elbow: an in\u00a0vitro biomechanical study","volume":"22","author":"Fraser","year":"2008","journal-title":"J Orthop Trauma"},{"key":"10.1016\/j.jse.2014.09.019_bib9","doi-asserted-by":"crossref","first-page":"1218","DOI":"10.1016\/j.jhsa.2007.06.008","article-title":"The effect of the annular ligament on kinematics of the radial head","volume":"32","author":"Galik","year":"2007","journal-title":"J\u00a0Hand Surg Am"},{"key":"10.1016\/j.jse.2014.09.019_bib10","doi-asserted-by":"crossref","first-page":"e12","DOI":"10.1016\/j.jse.2007.04.009","article-title":"Radiocapitellar hemiarthroplasty for radiocapitellar arthritis: a report of three cases","volume":"17","author":"Heijink","year":"2008","journal-title":"J\u00a0Shoulder Elbow Surg"},{"key":"10.1016\/j.jse.2014.09.019_bib11","doi-asserted-by":"crossref","first-page":"112","DOI":"10.1054\/arth.2001.16499","article-title":"An anthropometric study of the radial head: implications in the design of a prosthesis","volume":"16","author":"King","year":"2001","journal-title":"J\u00a0Arthroplasty"},{"key":"10.1016\/j.jse.2014.09.019_bib12","doi-asserted-by":"crossref","first-page":"225","DOI":"10.1007\/s00276-007-0197-1","article-title":"Morphometric parameters of the radial head: an anatomical study","volume":"29","author":"Koslowsky","year":"2007","journal-title":"Surg Radiol Anat"},{"key":"10.1016\/j.jse.2014.09.019_bib13","doi-asserted-by":"crossref","first-page":"123","DOI":"10.1002\/bjs.18004217203","article-title":"Some observations on fractures of the head of the radius with a review of one hundred cases","volume":"42","author":"Mason","year":"1954","journal-title":"Br J Surg"},{"key":"10.1016\/j.jse.2014.09.019_bib14","doi-asserted-by":"crossref","first-page":"533","DOI":"10.1016\/j.jse.2009.10.010","article-title":"Image-based navigation improves the positioning of the humeral component in total elbow arthroplasty","volume":"19","author":"McDonald","year":"2010","journal-title":"J Shoulder Elbow Surg"},{"key":"10.1016\/j.jse.2014.09.019_bib15","series-title":"The elbow and its disorders","isbn-type":"print","first-page":"419","author":"Morrey","year":"2008","ISBN":"http:\/\/id.crossref.org\/isbn\/1416029028"},{"key":"10.1016\/j.jse.2014.09.019_bib16","doi-asserted-by":"crossref","first-page":"1024","DOI":"10.1016\/j.jhsa.2012.02.021","article-title":"Elbow kinematics after radiocapitellar arthroplasty","volume":"37","author":"Sabo","year":"2012","journal-title":"J Hand Surg Am"},{"key":"10.1016\/j.jse.2014.09.019_bib17","doi-asserted-by":"crossref","first-page":"564","DOI":"10.1002\/ca.10256","article-title":"Anatomical considerations of the radius","volume":"17","author":"van Riet","year":"2004","journal-title":"Clin Anat"},{"key":"10.1016\/j.jse.2014.09.019_bib18","doi-asserted-by":"crossref","first-page":"972","DOI":"10.1016\/S0363-5023(03)00426-X","article-title":"The noncircular shape of the radial head","volume":"28","author":"van Riet","year":"2003","journal-title":"J Hand Surg Am"}],"container-title":["Journal of Shoulder and Elbow Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1058274614005187?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1058274614005187?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2018,9,28]],"date-time":"2018-09-28T00:21:47Z","timestamp":1538094107000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1058274614005187"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,2]]},"references-count":18,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2015,2]]}},"alternative-id":["S1058274614005187"],"URL":"https:\/\/doi.org\/10.1016\/j.jse.2014.09.019","relation":{},"ISSN":["1058-2746"],"issn-type":[{"value":"1058-2746","type":"print"}],"subject":[],"published":{"date-parts":[[2015,2]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"The effect of radial head implant shape on radiocapitellar kinematics during in\u00a0vitro forearm rotation","name":"articletitle","label":"Article Title"},{"value":"Journal of Shoulder and Elbow Surgery","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jse.2014.09.019","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}