{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,8]],"date-time":"2026-10-08T11:59:21Z","timestamp":1791460761178,"version":"4.3.4"},"reference-count":15,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2026,9,1]],"date-time":"2026-09-01T00:00:00Z","timestamp":1788220800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,9,1]],"date-time":"2026-09-01T00:00:00Z","timestamp":1788220800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","jshoulderelbow.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Shoulder and Elbow Surgery"],"published-print":{"date-parts":[[2026,9]]},"DOI":"10.1016\/j.jse.2026.08.024","type":"journal-article","created":{"date-parts":[[2026,9,4]],"date-time":"2026-09-04T23:46:58Z","timestamp":1788565618000},"update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"title":["Allograft strut fixation to humeral bone: a biomechanical comparison of suture tape cerclage, wire cerclage, and screws"],"prefix":"10.1016","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-9399-1370","authenticated-orcid":false,"given":"Mustafa","family":"Saffi","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8206-1680","authenticated-orcid":false,"given":"Cole T.","family":"Fleet","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6087-3434","authenticated-orcid":false,"given":"Ryosuke","family":"Iio","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Charles A.","family":"Gallagher","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"James A.","family":"Johnson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5174-219X","authenticated-orcid":false,"given":"George S.","family":"Athwal","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.jse.2026.08.024_bib1","doi-asserted-by":"crossref","first-page":"9","DOI":"10.2106\/JBJS.K.00863","article-title":"Surgically treated humeral shaft fractures following shoulder arthroplasty","volume":"95","author":"Andersen","year":"2013","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.jse.2026.08.024_bib2","doi-asserted-by":"crossref","first-page":"e382","DOI":"10.3928\/01477447-20161202-05","article-title":"The doubled-suture nice knot","volume":"40","author":"Boileau","year":"2017","journal-title":"Orthopedics"},{"key":"10.1016\/j.jse.2026.08.024_bib3","doi-asserted-by":"crossref","first-page":"e609","DOI":"10.5435\/JAAOS-D-20-00047","article-title":"A tensionable suture-based cerclage is an alternative to stainless steel cerclage fixation for stabilization of a humeral osteotomy during shoulder arthroplasty","volume":"29","author":"Denard","year":"2021","journal-title":"J Am Acad Orthop Surg"},{"issue":"285","key":"10.1016\/j.jse.2026.08.024_bib4","first-page":"35","article-title":"Cortical strut allografts in the reconstruction of the femur in revision total hip arthroplasty. A basic science and clinical study","author":"Emerson","year":"1992","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.jse.2026.08.024_bib5","doi-asserted-by":"crossref","first-page":"971","DOI":"10.2106\/00004623-200107000-00001","article-title":"Retrieved human allografts: a clinicopathological study","volume":"83","author":"Enneking","year":"2001","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.jse.2026.08.024_bib6","doi-asserted-by":"crossref","first-page":"688","DOI":"10.1016\/j.jseint.2020.03.002","article-title":"Suture cerclage for stabilizing the humeral shaft during shoulder arthroplasty","volume":"4","author":"Eyberg","year":"2020","journal-title":"JSES Int"},{"key":"10.1016\/j.jse.2026.08.024_bib7","doi-asserted-by":"crossref","first-page":"e324","DOI":"10.1016\/j.jse.2025.05.028","article-title":"A biomechanical evaluation of rotator cuff footprint contact mechanics after rotator cuff repair with and without the augmentation of a subacromial balloon","volume":"35","author":"Fleet","year":"2026","journal-title":"J Shoulder Elbow Surg"},{"key":"10.1016\/j.jse.2026.08.024_bib8","doi-asserted-by":"crossref","first-page":"6","DOI":"10.1016\/j.jseint.2024.08.187","article-title":"Identification of an anatomical safe zone for humeral cerclage passage","volume":"9","author":"Gulbrandsen","year":"2025","journal-title":"JSES Int"},{"key":"10.1016\/j.jse.2026.08.024_bib9","first-page":"20","article-title":"Is nice knot suture comparable to wire for cerclage fixation? A biomechanical performance study","volume":"2","author":"Gupta","year":"2022","journal-title":"JSES Rev Rep Tech"},{"key":"10.1016\/j.jse.2026.08.024_bib10","doi-asserted-by":"crossref","first-page":"945","DOI":"10.2106\/00004623-200206000-00008","article-title":"Periprosthetic femoral fractures around well-fixed implants: use of cortical onlay allografts with or without a plate","volume":"84","author":"Haddad","year":"2002","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.jse.2026.08.024_bib11","doi-asserted-by":"crossref","first-page":"3899","DOI":"10.1007\/s00402-022-04641-9","article-title":"Iatrogenic nerve injury in primary and revision reverse total shoulder arthroplasty","volume":"143","author":"Hruby","year":"2023","journal-title":"Arch Orthop Trauma Surg"},{"key":"10.1016\/j.jse.2026.08.024_bib12","doi-asserted-by":"crossref","first-page":"1568","DOI":"10.1016\/j.jse.2014.02.012","article-title":"Stainless steel wire versus FiberWire suture cerclage fixation to stabilize the humerus in total shoulder arthroplasty","volume":"23","author":"Renner","year":"2014","journal-title":"J Shoulder Elbow Surg"},{"key":"10.1016\/j.jse.2026.08.024_bib13","first-page":"490","article-title":"Strut graft vs. traditional plating in the management of periprosthetic humeral fractures: a multicentric cohort study","volume":"17","author":"Rollo","year":"2020","journal-title":"Med Glas"},{"key":"10.1016\/j.jse.2026.08.024_bib14","doi-asserted-by":"crossref","first-page":"e1227","DOI":"10.5435\/JAAOS-D-21-01001","article-title":"Periprosthetic postoperative humeral fractures after shoulder arthroplasty","volume":"30","author":"Sanchez-Sotelo","year":"2022","journal-title":"J Am Acad Orthop Surg"},{"key":"10.1016\/j.jse.2026.08.024_bib15","doi-asserted-by":"crossref","first-page":"43","DOI":"10.1007\/s11751-013-0155-x","article-title":"The management of complex periprosthetic humeral fractures: a case series of strut allograft augmentation, and a review of the literature","volume":"8","author":"Trompeter","year":"2013","journal-title":"Strateg Trauma Limb Reconstr"}],"container-title":["Journal of Shoulder and Elbow Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1058274626005355?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1058274626005355?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,10,8]],"date-time":"2026-10-08T11:34:53Z","timestamp":1791459293000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1058274626005355"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9]]},"references-count":15,"alternative-id":["S1058274626005355"],"URL":"https:\/\/doi.org\/10.1016\/j.jse.2026.08.024","relation":{},"ISSN":["1058-2746"],"issn-type":[{"value":"1058-2746","type":"print"}],"subject":[],"published":{"date-parts":[[2026,9]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Allograft strut fixation to humeral bone: a biomechanical comparison of suture tape cerclage, wire cerclage, and screws","name":"articletitle","label":"Article Title"},{"value":"Journal of Shoulder and Elbow Surgery","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jse.2026.08.024","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2026 American Shoulder and Elbow Surgeons. Published by Elsevier Inc. All rights are reserved, including those for text and data mining, AI training, and similar technologies.","name":"copyright","label":"Copyright"}]}}