{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,29]],"date-time":"2026-01-29T21:29:43Z","timestamp":1769722183232,"version":"3.49.0"},"reference-count":19,"publisher":"Elsevier BV","issue":"4","license":[{"start":{"date-parts":[[2023,7,1]],"date-time":"2023-07-01T00:00:00Z","timestamp":1688169600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2023,7,1]],"date-time":"2023-07-01T00:00:00Z","timestamp":1688169600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2023,3,30]],"date-time":"2023-03-30T00:00:00Z","timestamp":1680134400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"funder":[{"DOI":"10.13039\/100007307","name":"Arthrex","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100007307","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["jsesarthroplasty.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["JSES International"],"published-print":{"date-parts":[[2023,7]]},"DOI":"10.1016\/j.jseint.2023.03.002","type":"journal-article","created":{"date-parts":[[2023,4,5]],"date-time":"2023-04-05T21:03:43Z","timestamp":1680728623000},"page":"685-691","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":2,"title":["Biomechanical characteristics of a new looping stitch versus the classic Krackow stitch for distal biceps fixation"],"prefix":"10.1016","volume":"7","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-7627-126X","authenticated-orcid":false,"given":"Charles","family":"Long","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6481-6779","authenticated-orcid":false,"given":"Andrew","family":"Nakla","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0978-9346","authenticated-orcid":false,"given":"Min-Shik","family":"Chung","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Daniel","family":"Kwak","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2266-2622","authenticated-orcid":false,"given":"Michelle H.","family":"McGarry","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Oliver","family":"Hauck","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Orr","family":"Limpisvasti","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8483-5085","authenticated-orcid":false,"given":"Gregory J.","family":"Adamson","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1639-0280","authenticated-orcid":false,"given":"Thay Q.","family":"Lee","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.jseint.2023.03.002_bib1","doi-asserted-by":"crossref","first-page":"2045","DOI":"10.1177\/0363546507305679","article-title":"Is it safe to perform aggressive rehabilitation after distal biceps tendon repair using the modified 2-incision approach? A biomechanical study","volume":"35","author":"Bisson","year":"2007","journal-title":"Am J Sports Med"},{"key":"10.1016\/j.jseint.2023.03.002_bib2","doi-asserted-by":"crossref","first-page":"599","DOI":"10.1016\/j.arthro.2007.11.020","article-title":"Krackow locking stitch versus nonlocking premanufactured loop stitch for soft-tissue fixation: a biomechanical study","volume":"24","author":"Deramo","year":"2008","journal-title":"Arthroscopy"},{"key":"10.1016\/j.jseint.2023.03.002_bib3","doi-asserted-by":"crossref","first-page":"175","DOI":"10.1016\/0021-9290(69)90029-3","article-title":"Cross-sectional area measurements for tendon specimens: a comparison of several methods","volume":"2","author":"Ellis","year":"1969","journal-title":"J\u00a0Biomech"},{"key":"10.1016\/j.jseint.2023.03.002_bib4","doi-asserted-by":"crossref","first-page":"3003","DOI":"10.1177\/0363546514550989","article-title":"Biomechanical comparison of Krackow locking stitch versus nonlocking loop stitch with varying number of throws","volume":"42","author":"Hahn","year":"2014","journal-title":"Am J Sports Med"},{"key":"10.1016\/j.jseint.2023.03.002_bib5","doi-asserted-by":"crossref","first-page":"552","DOI":"10.1007\/s11999-016-5153-0","article-title":"Do needleless knots have similar strength as the Krackow suture? An in\u00a0vitro porcine tendon study","volume":"475","author":"Hong","year":"2017","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.jseint.2023.03.002_bib6","doi-asserted-by":"crossref","first-page":"1609","DOI":"10.1016\/j.arthro.2014.06.029","article-title":"Effect of the number of suture throws on the biomechanical characteristics of the suture-tendon construct","volume":"30","author":"Hong","year":"2014","journal-title":"Arthroscopy"},{"key":"10.1016\/j.jseint.2023.03.002_bib7","article-title":"Longer stitch interval in the Krackow stitch for tendon graft fixation leads to poorer biomechanical property","volume":"26","author":"Hong","year":"2018","journal-title":"J\u00a0Orthop Surg (Hong Kong)"},{"key":"10.1016\/j.jseint.2023.03.002_bib8","doi-asserted-by":"crossref","first-page":"237","DOI":"10.1007\/s00402-017-2830-8","article-title":"Superior biomechanical properties and tying time with the modified Prusik knot and Wittstein suture loop to the Krackow stitch","volume":"138","author":"Hong","year":"2018","journal-title":"Arch Orthop Trauma Surg"},{"key":"10.1016\/j.jseint.2023.03.002_bib9","doi-asserted-by":"crossref","first-page":"1151","DOI":"10.1016\/j.arthro.2015.01.011","article-title":"Evaluation of 3 needleless grasping suture techniques for soft-tissue graft fixation: a porcine biomechanical study","volume":"31","author":"Hong","year":"2015","journal-title":"Arthroscopy"},{"key":"10.1016\/j.jseint.2023.03.002_bib10","doi-asserted-by":"crossref","first-page":"968","DOI":"10.1177\/0363546505284185","article-title":"Distal biceps tendon repair: a biomechanical comparison of intact tendon and 2 repair techniques","volume":"34","author":"Idler","year":"2006","journal-title":"Am J Sports Med"},{"key":"10.1016\/j.jseint.2023.03.002_bib11","doi-asserted-by":"crossref","first-page":"764","DOI":"10.2106\/00004623-198668050-00020","article-title":"A\u00a0new stitch for ligament-tendon fixation. Brief note","volume":"68","author":"Krackow","year":"1986","journal-title":"J\u00a0Bone Joint Surg Am"},{"key":"10.1016\/j.jseint.2023.03.002_bib12","doi-asserted-by":"crossref","first-page":"252","DOI":"10.1177\/0363546506294854","article-title":"Biomechanical evaluation of 4 techniques of distal biceps brachii tendon repair","volume":"35","author":"Mazzocca","year":"2007","journal-title":"Am J Sports Med"},{"key":"10.1016\/j.jseint.2023.03.002_bib13","doi-asserted-by":"crossref","first-page":"33","DOI":"10.1016\/j.arthro.2005.10.008","article-title":"The Krackow stitch: a biomechanical evaluation of changing the number of loops versus the number of sutures","volume":"22","author":"McKeon","year":"2006","journal-title":"Arthroscopy"},{"key":"10.1016\/j.jseint.2023.03.002_bib14","doi-asserted-by":"crossref","first-page":"418","DOI":"10.2106\/00004623-198567030-00011","article-title":"Rupture of the distal tendon of the biceps brachii. A biomechanical study","volume":"67","author":"Morrey","year":"1985","journal-title":"J\u00a0Bone Joint Surg Am"},{"key":"10.1016\/j.jseint.2023.03.002_bib15","doi-asserted-by":"crossref","first-page":"361","DOI":"10.1016\/j.jse.2013.06.019","article-title":"Biomechanical effects of a 2 suture-pass medial inter-implant mattress on transosseous-equivalent rotator cuff repair and considerations for a \u201ctechnical efficiency ratio\u201d","volume":"23","author":"Park","year":"2014","journal-title":"J\u00a0Shoulder Elbow Surg"},{"key":"10.1016\/j.jseint.2023.03.002_bib16","doi-asserted-by":"crossref","first-page":"53","DOI":"10.1016\/j.jse.2009.05.007","article-title":"Biomechanical evaluation of distal biceps reconstruction with cortical button and interference screw fixation","volume":"19","author":"Sethi","year":"2010","journal-title":"J\u00a0Shoulder Elbow Surg"},{"key":"10.1016\/j.jseint.2023.03.002_bib17","doi-asserted-by":"crossref","first-page":"130","DOI":"10.1097\/JSA.0b013e31818247cb","article-title":"Distal biceps repair using cortical button fixation","volume":"16","author":"Sethi","year":"2008","journal-title":"Sports Med Arthrosc Rev"},{"key":"10.1016\/j.jseint.2023.03.002_bib18","doi-asserted-by":"crossref","first-page":"235","DOI":"10.1007\/s00776-013-0504-0","article-title":"Biomechanical characteristics of the horizontal mattress stitch: implication for double-row and suture-bridge rotator cuff repair","volume":"19","author":"Tamboli","year":"2014","journal-title":"J\u00a0Orthop Sci"},{"key":"10.1016\/j.jseint.2023.03.002_bib19","doi-asserted-by":"crossref","first-page":"1662","DOI":"10.1016\/j.arthro.2010.05.013","article-title":"Krackow locking stitch versus locking premanufactured loop stitch for soft-tissue fixation: a biomechanical study","volume":"26","author":"White","year":"2010","journal-title":"Arthroscopy"}],"container-title":["JSES International"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2666638323000683?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2666638323000683?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,11,13]],"date-time":"2025-11-13T03:19:58Z","timestamp":1763003998000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2666638323000683"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,7]]},"references-count":19,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2023,7]]}},"alternative-id":["S2666638323000683"],"URL":"https:\/\/doi.org\/10.1016\/j.jseint.2023.03.002","relation":{},"ISSN":["2666-6383"],"issn-type":[{"value":"2666-6383","type":"print"}],"subject":[],"published":{"date-parts":[[2023,7]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Biomechanical characteristics of a new looping stitch versus the classic Krackow stitch for distal biceps fixation","name":"articletitle","label":"Article Title"},{"value":"JSES International","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jseint.2023.03.002","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2023 The Authors. Published by Elsevier Inc. on behalf of American Shoulder and Elbow Surgeons.","name":"copyright","label":"Copyright"}]}}