{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,10]],"date-time":"2026-02-10T16:57:28Z","timestamp":1770742648710,"version":"3.49.0"},"reference-count":25,"publisher":"Elsevier BV","issue":"4","license":[{"start":{"date-parts":[[2024,7,1]],"date-time":"2024-07-01T00:00:00Z","timestamp":1719792000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2024,7,1]],"date-time":"2024-07-01T00:00:00Z","timestamp":1719792000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2024,4,23]],"date-time":"2024-04-23T00:00:00Z","timestamp":1713830400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/100009026","name":"Smith and Nephew plc","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100009026","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["jsesarthroplasty.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["JSES International"],"published-print":{"date-parts":[[2024,7]]},"DOI":"10.1016\/j.jseint.2024.04.008","type":"journal-article","created":{"date-parts":[[2024,4,27]],"date-time":"2024-04-27T01:30:25Z","timestamp":1714181425000},"page":"763-768","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":3,"title":["Safety and efficacy of second-generation all-suture anchors in labral tear arthroscopic repairs: prospective, multicenter, 1-year follow-up study"],"prefix":"10.1016","volume":"8","author":[{"given":"Andrew L.","family":"Wallace","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Emilio","family":"Calvo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jordi","family":"Ard\u00e8vol Cuesta","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Riccardo","family":"Lanzetti","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gonzalo","family":"Luengo-Alonso","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2614-8639","authenticated-orcid":false,"given":"Andrew S.","family":"Rokito","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5590-0696","authenticated-orcid":false,"suffix":"Jr","given":"Edwin E.","family":"Spencer","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Marco","family":"Spoliti","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.jseint.2024.04.008_bib1","doi-asserted-by":"crossref","first-page":"1026","DOI":"10.1016\/j.arthro.2018.10.144","article-title":"Predictive factors and the duration to pre-injury work status following biceps tenodesis","volume":"35","author":"Agarwalla","year":"2019","journal-title":"Arthrosc J Arthrosc Relat Surg"},{"key":"10.1016\/j.jseint.2024.04.008_bib2","doi-asserted-by":"crossref","first-page":"81","DOI":"10.4103\/0973-6042.161440","article-title":"Triple labrum tears repaired with the JuggerKnotTM soft anchor: technique and results","volume":"9","author":"Agrawal","year":"2015","journal-title":"Int J Shoulder Surg"},{"key":"10.1016\/j.jseint.2024.04.008_bib3","doi-asserted-by":"crossref","first-page":"1960","DOI":"10.1016\/j.arthro.2019.02.008","article-title":"Editorial commentary: all-suture shoulder glenoid anchors: can we adequately tension them or knot?","volume":"35","author":"Barber","year":"2019","journal-title":"Arthrosc J Arthrosc Relat Surg"},{"key":"10.1016\/j.jseint.2024.04.008_bib4","doi-asserted-by":"crossref","first-page":"78","DOI":"10.1016\/j.jse.2015.06.001","article-title":"A\u00a0guided surgical approach and novel fixation method for arthroscopic Latarjet","volume":"25","author":"Boileau","year":"2016","journal-title":"J\u00a0Shoulder Elbow Surg"},{"key":"10.1016\/j.jseint.2024.04.008_bib5","doi-asserted-by":"crossref","first-page":"287","DOI":"10.4055\/cios20317","article-title":"Biomaterials used for suture anchors in orthopedic surgery","volume":"13","author":"Cho","year":"2021","journal-title":"Clin Orthop Surg"},{"key":"10.1016\/j.jseint.2024.04.008_bib6","doi-asserted-by":"crossref","first-page":"e263","DOI":"10.1016\/j.asmr.2020.02.007","article-title":"The clinical and biomechanical performance of all-suture anchors: a systematic review","volume":"2","author":"Erg\u00fcn","year":"2020","journal-title":"Arthrosc Sports Med Rehabil"},{"key":"10.1016\/j.jseint.2024.04.008_bib7","doi-asserted-by":"crossref","DOI":"10.1177\/2325967117717010","article-title":"Biomechanical comparison of a first- and a second-generation all-soft suture glenoid anchor","volume":"5","author":"Erickson","year":"2017","journal-title":"Orthop J Sports Med"},{"key":"10.1016\/j.jseint.2024.04.008_bib8","doi-asserted-by":"crossref","first-page":"371","DOI":"10.4055\/cios19168","article-title":"Long head of the Biceps Tendon Tenotomy versus Subpectoral Tenodesis in rotator cuff repair","volume":"12","author":"Kim","year":"2020","journal-title":"Clin Orthop Surg"},{"key":"10.1016\/j.jseint.2024.04.008_bib9","doi-asserted-by":"crossref","first-page":"1351","DOI":"10.1016\/j.arthro.2018.12.011","article-title":"Comparison of clinical outcomes and computed tomography analysis for tunnel diameter after arthroscopic bankart repair with the all-suture anchor and the biodegradable suture anchor","volume":"35","author":"Lee","year":"2019","journal-title":"Arthrosc J Arthrosc Relat Surg"},{"key":"10.1016\/j.jseint.2024.04.008_bib10","doi-asserted-by":"crossref","first-page":"642","DOI":"10.1016\/j.arthro.2011.10.024","article-title":"Biomechanical evaluation of classic solid and novel all-soft suture anchors for glenoid labral repair","volume":"28","author":"Mazzocca","year":"2012","journal-title":"Arthrosc J Arthrosc Relat Surg"},{"key":"10.1016\/j.jseint.2024.04.008_bib11","first-page":"527","article-title":"Clinical and radiological outcomes of rotator cuff repairs using all-suture anchors as medial Row anchors","volume":"9","author":"Memon","year":"2021","journal-title":"Arch Bone Jt Surg"},{"key":"10.1016\/j.jseint.2024.04.008_bib12","doi-asserted-by":"crossref","first-page":"1124","DOI":"10.1016\/j.arthro.2007.05.011","article-title":"The Use of anchors in shoulder surgery: a shift from metallic to bioabsorbable anchors","volume":"23","author":"Ozbaydar","year":"2007","journal-title":"Arthrosc J Arthrosc Relat Surg"},{"key":"10.1016\/j.jseint.2024.04.008_bib13","doi-asserted-by":"crossref","first-page":"1561","DOI":"10.1016\/j.jse.2021.01.036","article-title":"Prospective, randomized evaluation of latissimus dorsi transfer and superior capsular reconstruction in massive, irreparable rotator cuff tears","volume":"30","author":"Ozturk","year":"2021","journal-title":"J\u00a0Shoulder Elbow Surg"},{"key":"10.1016\/j.jseint.2024.04.008_bib14","doi-asserted-by":"crossref","first-page":"1156","DOI":"10.1016\/j.jse.2013.12.036","article-title":"The histologic and biomechanical response of two commercially available small glenoid anchors for use in labral repairs","volume":"23","author":"Pfeiffer","year":"2014","journal-title":"J\u00a0Shoulder Elbow Surg"},{"key":"10.1016\/j.jseint.2024.04.008_bib15","doi-asserted-by":"crossref","first-page":"2284","DOI":"10.1016\/j.arthro.2019.03.032","article-title":"Perianchor cyst formation after arthroscopic rotator cuff repair using all-suture\u2013type, bioabsorbable-type, and PEEK-type anchors","volume":"35","author":"Ro","year":"2019","journal-title":"Arthrosc J Arthrosc Relat Surg"},{"key":"10.1016\/j.jseint.2024.04.008_bib16","doi-asserted-by":"crossref","first-page":"2152","DOI":"10.1007\/s00167-020-06192-1","article-title":"Arthroscopic bankart repair with all-suture anchors does not cause important glenoid bone osteolysis: a volumetric CT study of 143 anchors","volume":"29","author":"Ruiz Ib\u00e1n","year":"2021","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"10.1016\/j.jseint.2024.04.008_bib17","doi-asserted-by":"crossref","first-page":"2342","DOI":"10.1007\/s00167-020-06314-9","article-title":"Arthroscopic remplissage with all-suture anchors causes cystic lesions in the humerus: a volumetric CT study of 55 anchors","volume":"29","author":"Ruiz Ib\u00e1n","year":"2021","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"10.1016\/j.jseint.2024.04.008_bib18","first-page":"192","article-title":"Arthroscopic labral repair with all-suture anchors: a magnetic resonance imaging retrospective study with a 2.5-year follow-up","volume":"18","author":"Sacchetti","year":"2021","journal-title":"Med Glas"},{"key":"10.1016\/j.jseint.2024.04.008_bib19","doi-asserted-by":"crossref","first-page":"3053","DOI":"10.1016\/j.arthro.2021.04.045","article-title":"Triple-row technique confers a lower retear rate than standard suture bridge technique in arthroscopic rotator cuff repairs","volume":"37","author":"Tanaka","year":"2021","journal-title":"Arthrosc J Arthrosc Relat Surg"},{"key":"10.1016\/j.jseint.2024.04.008_bib20","doi-asserted-by":"crossref","first-page":"1223","DOI":"10.2106\/JBJS.17.01169","article-title":"Glenoid bone reaction to all-soft suture anchors used for shoulder labral repairs","volume":"100","author":"Tompane","year":"2018","journal-title":"J\u00a0Bone Joint Surg"},{"key":"10.1016\/j.jseint.2024.04.008_bib21","first-page":"101","article-title":"All-suture anchors versus metal suture anchors in the arthroscopic treatment of traumatic anterior shoulder instability: a comparison of mid-term outcomes","volume":"32","author":"Uluyard\u0131mc\u0131","year":"2021","journal-title":"Jt Dis Relat Surg"},{"key":"10.1016\/j.jseint.2024.04.008_bib22","doi-asserted-by":"crossref","first-page":"437","DOI":"10.52312\/jdrs.2021.79712","article-title":"Comparison of anterior single- and standard two-portal techniques in arthroscopic Bankart repair","volume":"32","author":"Uzun","year":"2021","journal-title":"Jt Dis\u00a0Relat Surg"},{"key":"10.1016\/j.jseint.2024.04.008_bib23","doi-asserted-by":"crossref","first-page":"2006","DOI":"10.1016\/j.jse.2018.03.006","article-title":"Rotator cuff repair with all-suture anchors: a midterm magnetic resonance imaging evaluation of repair integrity and cyst formation","volume":"27","author":"Van der Bracht","year":"2018","journal-title":"J\u00a0Shoulder Elbow Surg"},{"key":"10.1016\/j.jseint.2024.04.008_bib24","series-title":"Arthroscopy and Sport injuries: Applications in high-level Athletes","first-page":"175","article-title":"Return to Sport after shoulder arthroscopy","author":"Vianello","year":"2016"},{"key":"10.1016\/j.jseint.2024.04.008_bib25","doi-asserted-by":"crossref","first-page":"70","DOI":"10.1016\/j.clinbiomech.2018.11.008","article-title":"The history of suture anchors in orthopaedic surgery","volume":"61","author":"Visscher","year":"2019","journal-title":"Clin BioMech"}],"container-title":["JSES International"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2666638324001130?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2666638324001130?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2024,10,24]],"date-time":"2024-10-24T23:15:39Z","timestamp":1729811739000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2666638324001130"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,7]]},"references-count":25,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2024,7]]}},"alternative-id":["S2666638324001130"],"URL":"https:\/\/doi.org\/10.1016\/j.jseint.2024.04.008","relation":{},"ISSN":["2666-6383"],"issn-type":[{"value":"2666-6383","type":"print"}],"subject":[],"published":{"date-parts":[[2024,7]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Safety and efficacy of second-generation all-suture anchors in labral tear arthroscopic repairs: prospective, multicenter, 1-year follow-up study","name":"articletitle","label":"Article Title"},{"value":"JSES International","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jseint.2024.04.008","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2024 The Author(s). Published by Elsevier Inc. on behalf of American Shoulder and Elbow Surgeons.","name":"copyright","label":"Copyright"}]}}