{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,8]],"date-time":"2025-11-08T22:06:55Z","timestamp":1762639615681,"version":"build-2065373602"},"reference-count":41,"publisher":"Elsevier BV","issue":"3","license":[{"start":{"date-parts":[[2025,5,1]],"date-time":"2025-05-01T00:00:00Z","timestamp":1746057600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2025,5,1]],"date-time":"2025-05-01T00:00:00Z","timestamp":1746057600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2025,1,7]],"date-time":"2025-01-07T00:00:00Z","timestamp":1736208000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["jsesarthroplasty.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["JSES International"],"published-print":{"date-parts":[[2025,5]]},"DOI":"10.1016\/j.jseint.2024.12.008","type":"journal-article","created":{"date-parts":[[2025,1,15]],"date-time":"2025-01-15T19:33:00Z","timestamp":1736969580000},"page":"779-787","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"title":["Errors in implant orientation estimation in novice vs. experienced surgeons during reverse shoulder arthroplasty for a superior glenoid wear pattern"],"prefix":"10.1016","volume":"9","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-3915-888X","authenticated-orcid":false,"given":"Ryan","family":"Lohre","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Aaron J.","family":"Bois","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Akshay","family":"Lobo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"J Whitcomb","family":"Pollock","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5393-2774","authenticated-orcid":false,"given":"Peter","family":"Lapner","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5174-219X","authenticated-orcid":false,"given":"George S.","family":"Athwal","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5894-685X","authenticated-orcid":false,"given":"Danny","family":"Goel","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.jseint.2024.12.008_bib2","doi-asserted-by":"crossref","first-page":"S33","DOI":"10.1016\/j.otsr.2015.06.031","article-title":"Complications and revision of reverse total shoulder arthroplasty","volume":"102","author":"Boileau","year":"2016","journal-title":"Orthop Traumatol Surg Res"},{"key":"10.1016\/j.jseint.2024.12.008_bib3","doi-asserted-by":"crossref","first-page":"1281","DOI":"10.1016\/j.jse.2018.11.074","article-title":"The reverse shoulder arthroplasty angle: a new measurement of glenoid inclination for reverse shoulder arthroplasty","volume":"28","author":"Boileau","year":"2019","journal-title":"J Shoulder Elbow Surg"},{"key":"10.1016\/j.jseint.2024.12.008_bib4","doi-asserted-by":"crossref","first-page":"1104","DOI":"10.1016\/j.jse.2019.10.026","article-title":"Lower operating volume in shoulder arthroplasty is associated with increased revision rates in the early postoperative period: long-term analysis from the Australian Orthopaedic Association National Joint Replacement Registry","volume":"29","author":"Brown","year":"2020","journal-title":"J Shoulder Elbow Surg"},{"key":"10.1016\/j.jseint.2024.12.008_bib5","doi-asserted-by":"crossref","first-page":"692","DOI":"10.2106\/JBJS.I.00177","article-title":"Two-dimensional glenoid version measurements vary with coronal and sagittal scapular rotation","volume":"92","author":"Bryce","year":"2010","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.jseint.2024.12.008_bib6","article-title":"Influence of radiographic viewing perspective on glenoid inclination measurement","volume":"3","author":"Chalmers","year":"2019","journal-title":"J Shoulder Elb Arthroplast"},{"key":"10.1016\/j.jseint.2024.12.008_bib7","doi-asserted-by":"crossref","first-page":"1946","DOI":"10.1016\/j.jse.2018.04.015","article-title":"Instability after reverse total shoulder arthroplasty","volume":"27","author":"Cheung","year":"2018","journal-title":"J Shoulder Elbow Surg"},{"key":"10.1016\/j.jseint.2024.12.008_bib8","doi-asserted-by":"crossref","first-page":"213","DOI":"10.4055\/cios.2017.9.2.213","article-title":"Clinical outcomes and complications during the learning curve for reverse total shoulder arthroplasty: an analysis of the first 40 cases","volume":"9","author":"Cho","year":"2017","journal-title":"Clin Orthop Surg"},{"key":"10.1016\/j.jseint.2024.12.008_bib9","doi-asserted-by":"crossref","first-page":"284","DOI":"10.1037\/1040-3590.6.4.284","article-title":"Guidelines, criteria, and rules of thumb for evaluating normed and standardized assessment instruments in psychology","volume":"4","author":"Cicchetti","year":"1994","journal-title":"Psychol Assess"},{"key":"10.1016\/j.jseint.2024.12.008_bib10","doi-asserted-by":"crossref","first-page":"59","DOI":"10.4103\/0973-6042.180717","article-title":"Accuracy of patient-specific instrumentation in anatomic and reverse total shoulder arthroplasty","volume":"10","author":"Dallalana","year":"2016","journal-title":"Int J Shoulder Surg"},{"key":"10.1016\/j.jseint.2024.12.008_bib11","doi-asserted-by":"crossref","first-page":"S27","DOI":"10.1007\/s12306-012-0193-4","article-title":"Reverse total shoulder arthroplasty: radiological and clinical result using an eccentric glenosphere","volume":"96 Suppl 1","author":"De Biase","year":"2012","journal-title":"Musculoskelet Surg"},{"key":"10.1016\/j.jseint.2024.12.008_bib12","doi-asserted-by":"crossref","first-page":"144","DOI":"10.1016\/j.jses.2019.11.004","article-title":"The influence of glenoid component position on scapular notching: a detailed radiographic analysis at midterm follow-up","volume":"4","author":"Duethman","year":"2020","journal-title":"JSES Int"},{"key":"10.1016\/j.jseint.2024.12.008_bib13","doi-asserted-by":"crossref","first-page":"429","DOI":"10.1038\/415429a","article-title":"Humans integrate visual and haptic information in a statistically optimal fashion","volume":"415","author":"Ernst","year":"2002","journal-title":"Nature"},{"issue":"6 Suppl","key":"10.1016\/j.jseint.2024.12.008_bib14","doi-asserted-by":"crossref","first-page":"S131","DOI":"10.1016\/j.otsr.2011.06.007","article-title":"Scapular notching in reverse shoulder arthroplasties: the influence of glenometaphyseal angle","volume":"97","author":"Falaise","year":"2011","journal-title":"Orthop Traumatol Surg Res"},{"key":"10.1016\/j.jseint.2024.12.008_bib15","doi-asserted-by":"crossref","first-page":"1032","DOI":"10.2106\/00004623-199274070-00009","article-title":"The use of computerized tomography in the measurement of glenoid version","volume":"74","author":"Friedman","year":"1992","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.jseint.2024.12.008_bib16","doi-asserted-by":"crossref","first-page":"141","DOI":"10.11613\/BM.2015.015","article-title":"Understanding bland altman analysis","volume":"25","author":"Giavarina","year":"2015","journal-title":"Biochem Med"},{"key":"10.1016\/j.jseint.2024.12.008_bib17","doi-asserted-by":"crossref","first-page":"258","DOI":"10.1080\/17453674.2020.1871559","article-title":"The rate of 2nd revision for shoulder arthroplasty as analyzed by the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR)","volume":"92","author":"Gill","year":"2021","journal-title":"Acta Orthop"},{"key":"10.1016\/j.jseint.2024.12.008_bib18","doi-asserted-by":"crossref","DOI":"10.1371\/journal.pone.0075791","article-title":"Accuracy of glenoid component placement in total shoulder arthroplasty and its effect on clinical and radiological outcome in a retrospective, longitudinal, monocentric open study","volume":"8","author":"Gregory","year":"2013","journal-title":"PLoS One"},{"key":"10.1016\/j.jseint.2024.12.008_bib19","doi-asserted-by":"crossref","first-page":"388","DOI":"10.1016\/j.jse.2013.06.002","article-title":"Complications rates, reoperation rates, and the learning curve in reverse shoulder arthroplasty","volume":"23","author":"Groh","year":"2014","journal-title":"J Shoulder Elbow Surg"},{"key":"10.1016\/j.jseint.2024.12.008_bib20","doi-asserted-by":"crossref","first-page":"788","DOI":"10.1016\/j.ejrad.2014.02.005","article-title":"Correlations between the alpha angle and femoral head asphericity: implications and recommendations for the diagnosis of cam femoroacetabular impingement","volume":"83","author":"Harris","year":"2014","journal-title":"Eur J Radiol"},{"key":"10.1016\/j.jseint.2024.12.008_bib21","doi-asserted-by":"crossref","first-page":"86","DOI":"10.1097\/00003086-200302000-00016","article-title":"Glenoid inclination is associated with full-thickness rotator cuff tears","author":"Hughes","year":"2003","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.jseint.2024.12.008_bib22","doi-asserted-by":"crossref","first-page":"151","DOI":"10.1016\/j.jse.2017.08.025","article-title":"The critical acromial point: the anatomic location of the lateral acromion in the critical shoulder angle","volume":"27","author":"Karns","year":"2018","journal-title":"J Shoulder Elbow Surg"},{"key":"10.1016\/j.jseint.2024.12.008_bib23","doi-asserted-by":"crossref","first-page":"2496","DOI":"10.1007\/s11999-011-1811-4","article-title":"A complication-based learning curve from 200 reverse shoulder arthroplasties","volume":"469","author":"Kempton","year":"2011","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.jseint.2024.12.008_bib24","doi-asserted-by":"crossref","first-page":"189","DOI":"10.1302\/2058-5241.6.200085","article-title":"An update on reverse total shoulder arthroplasty: current indications, new designs, same old problems","volume":"6","author":"Kozak","year":"2021","journal-title":"EFORT Open Rev"},{"key":"10.1016\/j.jseint.2024.12.008_bib25","doi-asserted-by":"crossref","first-page":"1582","DOI":"10.1016\/j.jse.2014.06.029","article-title":"Avoiding superior tilt in reverse shoulder arthroplasty: a review of the literature and technical recommendations","volume":"23","author":"Laver","year":"2014","journal-title":"J Shoulder Elbow Surg"},{"key":"10.1016\/j.jseint.2024.12.008_bib26","doi-asserted-by":"crossref","first-page":"69","DOI":"10.25259\/JCIS_105_2020","article-title":"DRRGenerator: a three-dimensional slicer extension for the rapid and easy development of digitally reconstructed radiographs","volume":"10","author":"Levine","year":"2020","journal-title":"J Clin Imaging Sci"},{"key":"10.1016\/j.jseint.2024.12.008_bib27","doi-asserted-by":"crossref","DOI":"10.1001\/jamanetworkopen.2020.31217","article-title":"Effectiveness of immersive virtual reality for orthopaedic surgical skills and knowledge acquisition: a randomized controlled trial","volume":"3","author":"Lohre","year":"2020","journal-title":"JAMA Netw Open"},{"key":"10.1016\/j.jseint.2024.12.008_bib28","doi-asserted-by":"crossref","DOI":"10.5435\/JAAOSGlobal-D-21-00193","article-title":"Mitigating surgical skill decay in orthopaedics using virtual simulation learning","volume":"5","author":"Lohre","year":"2021","journal-title":"JAAOS Glob Res Rev"},{"key":"10.1016\/j.jseint.2024.12.008_bib29","doi-asserted-by":"crossref","first-page":"1096","DOI":"10.1016\/j.jse.2011.07.010","article-title":"Assessment of glenoid inclination on routine clinical radiographs and computed tomography examinations of the shoulder","volume":"21","author":"Maurer","year":"2012","journal-title":"J Shoulder Elbow Surg"},{"key":"10.1016\/j.jseint.2024.12.008_bib30","doi-asserted-by":"crossref","first-page":"1253","DOI":"10.1016\/j.jse.2016.11.043","article-title":"Impact of scapular notching on clinical outcomes after reverse total shoulder arthroplasty: an analysis of 476 shoulders","volume":"26","author":"Mollon","year":"2017","journal-title":"J Shoulder Elbow Surg"},{"key":"10.1016\/j.jseint.2024.12.008_bib31","doi-asserted-by":"crossref","first-page":"721","DOI":"10.1016\/j.amjsurg.2016.10.018","article-title":"Skill learning from kinesthetic feedback","volume":"214","author":"Pinzon","year":"2017","journal-title":"Am J Surg"},{"key":"10.1016\/j.jseint.2024.12.008_bib32","doi-asserted-by":"crossref","first-page":"519","DOI":"10.1016\/j.ocl.2018.05.012","article-title":"The volume-value relationship in shoulder arthroplasty","volume":"49","author":"Ramkumar","year":"2018","journal-title":"Orthop Clin N Am"},{"key":"10.1016\/j.jseint.2024.12.008_bib33","doi-asserted-by":"crossref","first-page":"243","DOI":"10.2466\/pms.1986.62.1.243","article-title":"Visual dominance in the cross-modal kinesthetic to kinesthetic plus visual feedback condition","volume":"62","author":"Reeve","year":"1986","journal-title":"Percept Mot Skills"},{"key":"10.1016\/j.jseint.2024.12.008_bib34","doi-asserted-by":"crossref","first-page":"542","DOI":"10.1007\/s12178-019-09586-y","article-title":"Reverse total shoulder arthroplasty: biomechanics and indications","volume":"12","author":"Rugg","year":"2019","journal-title":"Curr Rev Musculoskelet Med"},{"key":"10.1016\/j.jseint.2024.12.008_bib35","first-page":"E148","article-title":"Assessment of scapular morphology and surgical technique as predictors of notching in reverse shoulder arthroplasty","volume":"44","author":"Sabesan","year":"2015","journal-title":"Am J Orthop (Belle Mead NJ)"},{"key":"10.1016\/j.jseint.2024.12.008_bib36","doi-asserted-by":"crossref","first-page":"929","DOI":"10.1016\/j.jseint.2020.07.017","article-title":"The modern reverse shoulder arthroplasty and an updated systematic review for each complication: part I","volume":"4","author":"Shah","year":"2020","journal-title":"JSES Int"},{"key":"10.1016\/j.jseint.2024.12.008_bib37","doi-asserted-by":"crossref","first-page":"121","DOI":"10.1016\/j.jseint.2020.07.018","article-title":"The modern reverse shoulder arthroplasty and an updated systematic review for each complication: part II","volume":"5","author":"Shah","year":"2021","journal-title":"JSES Int"},{"key":"10.1016\/j.jseint.2024.12.008_bib38","doi-asserted-by":"crossref","first-page":"388","DOI":"10.1302\/0301-620X.86B3.14024","article-title":"Grammont inverted total shoulder arthroplasty in the treatment of glenohumeral osteoarthritis with massive rupture of the cuff: results of a multicentre study of 80 shoulders","volume":"86","author":"Sirveaux","year":"2004","journal-title":"J Bone Joint Surg Br"},{"key":"10.1016\/j.jseint.2024.12.008_bib39","doi-asserted-by":"crossref","first-page":"e149","DOI":"10.1016\/j.jse.2014.10.021","article-title":"The influence of radiographic viewing perspective and demographics on the critical shoulder angle","volume":"24","author":"Suter","year":"2015","journal-title":"J Shoulder Elbow Surg"},{"key":"10.1016\/j.jseint.2024.12.008_bib40","doi-asserted-by":"crossref","first-page":"1510","DOI":"10.1302\/0301-620X.98B11.37800","article-title":"Comparison of measurements of the glenopolar angle in 3D CT reconstructions of the scapula and 2D plain radiographic views","volume":"98-B","author":"Suter","year":"2016","journal-title":"Bone Joint J"},{"key":"10.1016\/j.jseint.2024.12.008_bib41","doi-asserted-by":"crossref","first-page":"632","DOI":"10.1016\/j.jse.2015.09.003","article-title":"Reliability analysis of glenoid component inclination measurements on postoperative radiographs and computed tomography-based 3D models in total and reversed shoulder arthroplasty patients","volume":"25","author":"Van Haver","year":"2016","journal-title":"J Shoulder Elbow Surg"},{"key":"10.1016\/j.jseint.2024.12.008_bib42","doi-asserted-by":"crossref","first-page":"146","DOI":"10.1016\/j.jse.2010.08.001","article-title":"Problems, complications, reoperations, and revisions in reverse total shoulder arthroplasty: a systematic review","volume":"20","author":"Zumstein","year":"2011","journal-title":"J Shoulder Elbow Surg"}],"container-title":["JSES International"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2666638325000064?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2666638325000064?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,11,8]],"date-time":"2025-11-08T22:02:31Z","timestamp":1762639351000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2666638325000064"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,5]]},"references-count":41,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2025,5]]}},"alternative-id":["S2666638325000064"],"URL":"https:\/\/doi.org\/10.1016\/j.jseint.2024.12.008","relation":{},"ISSN":["2666-6383"],"issn-type":[{"type":"print","value":"2666-6383"}],"subject":[],"published":{"date-parts":[[2025,5]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Errors in implant orientation estimation in novice vs. experienced surgeons during reverse shoulder arthroplasty for a superior glenoid wear pattern","name":"articletitle","label":"Article Title"},{"value":"JSES International","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jseint.2024.12.008","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2025 The Author(s). Published by Elsevier Inc. on behalf of American Shoulder and Elbow Surgeons.","name":"copyright","label":"Copyright"}]}}