{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,26]],"date-time":"2026-02-26T06:55:34Z","timestamp":1772088934178,"version":"3.50.1"},"reference-count":24,"publisher":"Elsevier BV","issue":"4","license":[{"start":{"date-parts":[[2025,7,1]],"date-time":"2025-07-01T00:00:00Z","timestamp":1751328000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2025,7,1]],"date-time":"2025-07-01T00:00:00Z","timestamp":1751328000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2025,4,30]],"date-time":"2025-04-30T00:00:00Z","timestamp":1745971200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["jsesarthroplasty.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["JSES International"],"published-print":{"date-parts":[[2025,7]]},"DOI":"10.1016\/j.jseint.2025.04.008","type":"journal-article","created":{"date-parts":[[2025,5,8]],"date-time":"2025-05-08T15:18:06Z","timestamp":1746717486000},"page":"1205-1209","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":1,"title":["Multifragmented InSpace balloon with foreign body\u2013induced inflammation: a case report"],"prefix":"10.1016","volume":"9","author":[{"given":"Abdelkader","family":"Shekhbihi","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0009-0004-2245-019X","authenticated-orcid":false,"given":"Alba","family":"Portes","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Philipp","family":"Moroder","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.jseint.2025.04.008_bib1","doi-asserted-by":"crossref","first-page":"1894","DOI":"10.2106\/JBJS.I.01531","article-title":"Massive tears of the rotator cuff","volume":"92","author":"Bedi","year":"2010","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.jseint.2025.04.008_bib2","doi-asserted-by":"crossref","first-page":"747","DOI":"10.2106\/00004623-200704000-00008","article-title":"Isolated arthroscopic biceps tenotomy or tenodesis improves symptoms in patients with massive irreparable rotator cuff tears","volume":"89","author":"Boileau","year":"2007","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.jseint.2025.04.008_bib3","doi-asserted-by":"crossref","first-page":"e313","DOI":"10.1016\/j.jse.2020.02.029","article-title":"Symptomatic foreign body reaction secondary to subacromial balloon spacer placement: a case report","volume":"29","author":"Calvo","year":"2020","journal-title":"J Shoulder Elbow Surg"},{"key":"10.1016\/j.jseint.2025.04.008_bib4","doi-asserted-by":"crossref","first-page":"1639","DOI":"10.1016\/j.arthro.2017.03.029","article-title":"Arthroscopic subacromial spacer implantation in patients with massive irreparable rotator cuff tears: clinical and radiographic results of 39 retrospectives cases","volume":"33","author":"Deranlot","year":"2017","journal-title":"Arthroscopy"},{"key":"10.1016\/j.jseint.2025.04.008_bib5","doi-asserted-by":"crossref","DOI":"10.2106\/JBJS.CC.23.00009","article-title":"Rice-body synovitis, foreign body reaction, and rotator cuff failure after subacromial balloon spacer augmentation of a rotator cuff repair","volume":"13","author":"Fury","year":"2023","journal-title":"JBJS Case Connect"},{"key":"10.1016\/j.jseint.2025.04.008_bib6","doi-asserted-by":"crossref","first-page":"1920","DOI":"10.2106\/JBJS.M.00122","article-title":"Latissimus dorsi tendon transfer for treatment of irreparable posterosuperior rotator cuff tears","volume":"95","author":"Gerber","year":"2013","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.jseint.2025.04.008_bib7","doi-asserted-by":"crossref","first-page":"85","DOI":"10.21037\/aoj.2018.10.02","article-title":"Balloon arthroplasty: indications, technique, and European outcomes","volume":"3","author":"Horneff","year":"2018","journal-title":"Ann Joint"},{"key":"10.1016\/j.jseint.2025.04.008_bib8","doi-asserted-by":"crossref","first-page":"162","DOI":"10.1016\/j.arthro.2023.05.028","article-title":"Subacromial balloon spacer implantation is a promising alternative for patients with massive irreparable rotator cuff tears: a systematic review","volume":"40","author":"Levy","year":"2024","journal-title":"Arthroscopy"},{"key":"10.1016\/j.jseint.2025.04.008_bib9","article-title":"Symptomatic early rupture of the InSpace subacromial balloon spacer: a case report","author":"Mangan","year":"2024","journal-title":"HSS J"},{"key":"10.1016\/j.jseint.2025.04.008_bib10","doi-asserted-by":"crossref","first-page":"1954","DOI":"10.1016\/S0140-6736(22)00652-3","article-title":"Subacromial balloon spacer for irreparable rotator cuff tears of the shoulder (START:REACTS): a group-sequential, double-blind, multicentre randomised controlled trial","volume":"399","author":"Metcalfe","year":"2022","journal-title":"Lancet"},{"key":"10.1016\/j.jseint.2025.04.008_bib11","doi-asserted-by":"crossref","first-page":"242","DOI":"10.1016\/j.arthro.2023.06.032","article-title":"Subacromial balloon spacer does not reduce the retear rate for massive rotator cuff tears: a comparative study","volume":"40","author":"Minarro","year":"2024","journal-title":"Arthroscopy"},{"key":"10.1016\/j.jseint.2025.04.008_bib12","doi-asserted-by":"crossref","first-page":"e459","DOI":"10.1016\/j.eats.2019.11.018","article-title":"\u201cStrings\u201d (multiple tendon interposition autografts) for reconstruction of presumably irreparable rotator cuff tears","volume":"9","author":"Moroder","year":"2020","journal-title":"Arthrosc Tech"},{"key":"10.1016\/j.jseint.2025.04.008_bib13","doi-asserted-by":"crossref","first-page":"119","DOI":"10.4055\/cios.2018.10.2.119","article-title":"Treatment strategy for irreparable rotator cuff tears","volume":"10","author":"Oh","year":"2018","journal-title":"Clin Orthop Surg"},{"key":"10.1016\/j.jseint.2025.04.008_bib14","doi-asserted-by":"crossref","first-page":"207","DOI":"10.1007\/s12306-019-00614-1","article-title":"The subacromial balloon spacer for massive irreparable rotator cuff tears: approximately 3 years of prospective follow-up","volume":"104","author":"Piekaar","year":"2020","journal-title":"Musculoskelet Surg"},{"key":"10.1016\/j.jseint.2025.04.008_bib15","doi-asserted-by":"crossref","first-page":"3848","DOI":"10.1007\/s00167-018-5083-3","article-title":"The absorbable subacromial spacer for irreparable posterosuperior cuff tears has inconsistent results","volume":"26","author":"Ruiz Ib\u00e1n","year":"2018","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"10.1016\/j.jseint.2025.04.008_bib16","doi-asserted-by":"crossref","first-page":"e69","DOI":"10.1016\/j.eats.2012.02.002","article-title":"New solution for massive, irreparable rotator cuff tears: the subacromial \u201cbiodegradable spacer\u201d","volume":"1","author":"Savarese","year":"2012","journal-title":"Arthrosc Tech"},{"key":"10.1016\/j.jseint.2025.04.008_bib17","doi-asserted-by":"crossref","first-page":"311","DOI":"10.1007\/s00590-012-0981-4","article-title":"Prospective clinical study of a novel biodegradable sub-acromial spacer in treatment of massive irreparable rotator cuff tears","volume":"23","author":"Senekovic","year":"2013","journal-title":"Eur J Orthop Surg Traumatol"},{"key":"10.1016\/j.jseint.2025.04.008_bib18","doi-asserted-by":"crossref","first-page":"95","DOI":"10.1007\/s00402-016-2603-9","article-title":"The biodegradable spacer as a novel treatment modality for massive rotator cuff tears: a prospective study with 5-year follow-up","volume":"137","author":"Senekovic","year":"2017","journal-title":"Arch Orthop Trauma Surg"},{"key":"10.1016\/j.jseint.2025.04.008_bib19","doi-asserted-by":"crossref","first-page":"382","DOI":"10.1016\/j.arthro.2018.09.016","article-title":"The subacromial balloon spacer versus superior capsular reconstruction in the treatment of irreparable rotator cuff tears: a biomechanical assessment","volume":"35","author":"Singh","year":"2019","journal-title":"Arthroscopy"},{"key":"10.1016\/j.jseint.2025.04.008_bib20","doi-asserted-by":"crossref","first-page":"1841","DOI":"10.1016\/j.jse.2019.03.036","article-title":"The effect of the subacromial balloon spacer on humeral head translation in the treatment of massive, irreparable rotator cuff tears: a biomechanical assessment","volume":"28","author":"Singh","year":"2019","journal-title":"J Shoulder Elbow Surg"},{"key":"10.1016\/j.jseint.2025.04.008_bib21","doi-asserted-by":"crossref","first-page":"1250","DOI":"10.2106\/JBJS.21.00667","article-title":"InSpace implant compared with partial repair for the treatment of full-thickness massive rotator cuff tears","volume":"104","author":"Verma","year":"2022","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.jseint.2025.04.008_bib22","doi-asserted-by":"crossref","first-page":"223","DOI":"10.1016\/j.jcot.2021.03.017","article-title":"Subacromial balloon spacer \u2013 where are we now?","volume":"17","author":"Viswanath","year":"2021","journal-title":"J Clin Orthop Trauma"},{"key":"10.1016\/j.jseint.2025.04.008_bib23","doi-asserted-by":"crossref","DOI":"10.1016\/j.otsr.2021.103072","article-title":"Superior capsular reconstruction \u2013 a systematic review and meta-analysis","volume":"107","author":"Werthel","year":"2021","journal-title":"Orthop Traumatol Surg Res"},{"key":"10.1016\/j.jseint.2025.04.008_bib24","doi-asserted-by":"crossref","first-page":"116","DOI":"10.1016\/j.jse.2009.04.006","article-title":"Prevalence and risk factors of a rotator cuff tear in the general population","volume":"19","author":"Yamamoto","year":"2010","journal-title":"J Shoulder Elbow Surg"}],"container-title":["JSES International"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S266663832500129X?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S266663832500129X?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,7,15]],"date-time":"2025-07-15T22:42:22Z","timestamp":1752619342000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S266663832500129X"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,7]]},"references-count":24,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2025,7]]}},"alternative-id":["S266663832500129X"],"URL":"https:\/\/doi.org\/10.1016\/j.jseint.2025.04.008","relation":{},"ISSN":["2666-6383"],"issn-type":[{"value":"2666-6383","type":"print"}],"subject":[],"published":{"date-parts":[[2025,7]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Multifragmented InSpace balloon with foreign body\u2013induced inflammation: a case report","name":"articletitle","label":"Article Title"},{"value":"JSES International","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jseint.2025.04.008","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2025 The Author(s). Published by Elsevier Inc. on behalf of American Shoulder and Elbow Surgeons.","name":"copyright","label":"Copyright"}]}}